I/A Series Software FoxGuard Manager for Triconex Safety Systems

Similar documents
Summary. Business Value

I/A Series HARDWARE Product Specifications

White Paper. The Tricon Turbine Control System

I/A Series Hardware 50 Series Application Workstation Processor AW51, Style C

Foxboro Evo Process Automation System

Model PC20 Intelligent Field Device Configurator for Use with Transmitters with FoxCom or HART Communication Protocol

Remote Bus Extender Slave Module

Trusted / SC300E Bridge Module

Advanced Diagnostics / Premium Diagnostics

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

I/A Series Software Data for Windows V2.3

2014 Software Global Client Conference

I/A Series SOFTWARE Product Specifications

16-Channel Digital Output Module 120Vac/dc

ICS Regent. Multiplexed I/O Modules PD-6035 (T3491)

ICS Regent. Communications Package for W INTERPRET. Guarded Peer-Link Communications (T3831) PD-6041

32-Channel Analogue Input Module Differential Input

Triconex Safety System Platforms

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

Training Courses AADvance & Trusted

Standard PACSystems 18-slot Wall (Rear) Mount. 15 Single Width, 8 Double Width (plus one for power supply) RX7i CPU and I/O, VME modules

MicroNet TMR Control System

I/A Series HARDWARE Product Specifications

Connecting SLC Systems as Remote I/O to PLC-5 Processors

TriSystems Engineering 2011 Training Brochure

Series Specialty PLCs

I/A Series Hardware. FBM223 PROFIBUS-DP Communication Interface Module PSS 21H-2Z23 B4 FEATURES OVERVIEW PRODUCT SPECIFICATIONS

Network Components. Network Components 8

ICS Regent. Guarded Analog Output Modules. 4 to 20 ma (T3480) PD-6026

3500/25 Enhanced Keyphasor*Module

PLC 5/250 Programmable Controller System Overview

I/A Series Control Suite Connoisseur Bridge

North America Process Automation Learning Services

GE Intelligent Platforms PAC8000 RTU

Installation Instructions

Triconex Ethernet Driver PTC Inc. All Rights Reserved.

Prepared By Turki AL-Mugaiteeb Control System Engineer EASTEREN PEROCHEMICAL COMPANY SHARQ 3 rd Expansion Project (OLEFIN)

Removal of Hardware ESD, Independent of Safety Logic Solver

I/A Series HARDWARE Product Specifications

InFusion SOFTWARE Product Specifications

DeltaV VerticalPlus I/O Subsystem Carriers

Process Automation Learning Services North America 2015 Course Schedule

First of all, thank you for purchasing R2W series redundant power supply.

Ovation Compact Controller

Trusted TM AN-T Application Note. Trusted TM / SC300E Migration process. Issue 01 Apr 08 AN-T80015 Page 1 of 16

Procontrol P14 Complete power plant control system

expertise beyond controls Vanguard Series 5

PRODUCT INFORMATION. AUMA Actuators, Inc. Pittsburgh PA USA. Triple Play Digital Communications Board DeviceNet / Modbus CDN455

CprE 458/558: Real-Time Systems. Lecture 17 Fault-tolerant design techniques

M-series Serial Interface Series 2

QuickSpecs. HPE Integrity Smart Array P411/256 2-port External PCIe 6Gb SAS Controller. Overview. What's New Boot from Tape

THE RAINBOW SCADA D-700

Chapter 1. Introduction. Additional Documentation

PROFIRE PF3100 Modbus Register Map PF

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

Ovation Controller Model OCR1100

Allen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon

PACSystems* RX3i IC695RMX228-ACAB Redundancy Memory Xchange Module

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

Cisco Prisma II Platform

Throughout this manual we use notes to make you aware of safety considerations:

smar First in Fieldbus Architecture Description Applications Engineering Department International Division 1

Avaya. Installation Guide M4-DS3 ATM SWITCHING MODULES FOR THE AVAYA M770

Copyright PLANET Technology Corp Contents subject to revision without prior notice.

Cajun P550/P880 Manger User Guide

Embedded systems extend automation

Modicon TSX Quantum Hot Standby Option Processor

IntegratedArchitecture

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

List of Components Versions for Safetec SFT-9000 systems

Enhanced Programmable Logic Controller Gateway Specification and Technical Data

DeltaV Connect Solution for Moore Systems

DGS-1510 Series Gigabit Ethernet SmartPro Switch Web UI Reference Guide. Figure 10-1 Cable Diagnostics window

PF MODBUS REGISTER MAP. v1.4 Revised Nov 29, 2016

All it takes to measure, collect and analyze energy consumption in heating and cooling applications

WaveReady. Optical Link Monitoring System: BrightJack 200ER

Serial Communication Converters & Adapters Instruction Manual

Technical Application Note

CPU 412H. Function. Parameterizable properties

Structure and Function

(Cat. No S4A, -S4B)

PLC-5 Programmable Controllers Comparison

(Catalog Number 1747-SN) Product Data

ALS c en Alspa CE80 20 N80 Bus Interface Unit User s Manual

QuickSpecs. Models. Overview

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

FOXBORO. I/A Series HARDWARE Product Specifications. Z-Module Control Processor 270 (ZCP270) PSS 21H-1B10 B3 FEATURES

M3-61B DeviceNet Slave Module. M3-61B DeviceNet Slave Module CONTROL TECHNOLOGY CORPORATION

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

ICS Regent. Thermocouple Input Assembly. Input Module, Mux, Termination Panel and Cable (T3431-IM, T3431-Mux, T3431-TP and T3431-CA) PD-6024

Distributed Control System Design Standards

Models Compaq NC3123 Fast Ethernet Adapter PCI, 10/100 WOL B21 Single B22 5-Pack

PACSystems* RX3i IC695PBM300

PRODUCT INFORMATION. DeviceNet Triple Play Digital Communications Board. SA Actuator with AUMA Matic Motor Controls

Fault Tolerant Protection System (Safety PLC with Integrated Overspeed Protection)

Product Overview. Switch Features Overview CHAPTER

DeltaV Remote Client. Introduction. Remote engineering and operator consoles. View Multiple DeltaV Systems from a single workstation

Zenith Series STS-3 Static Transfer Switches

Experion LX Safety Manager Integration Guide

Transcription:

Product Specifications I/A Series Software FoxGuard Manager for Triconex Safety Systems PSS 21S-3A5 B3 INTRODUCTION The Foxboro Company and Triconex Corporation offer a direct connect interface between the I/A Series open control system environment and Triconex Triple- Modular Redundant (TMR) programmable controllers. This direct connect interface enables the process operator to monitor safety system operation using familiar I/A Series displays. FoxGuard Manager also provides access to TRICON data for a variety of applications including sequence of events processing, data scanning, and process calculations and supports data input to the Triconex system from I/A Series systems. The FoxGuard Manager software interface is implemented on a Triconex Model 4609 Advanced Communications Module (ACM) installed in the TRICON chassis, which concurrently supports other proprietary Triconex interfaces such as the Tristation protocol for the TRISTATION MSW programming system. The ACM connects to the I/A Series Nodebus via the standard Dual Nodebus Interface (DNBI). FoxGuard Manager supports both a single ACM module configuration and a redundant pair in which the second module serves as a hot spare to take over operation should the first module fail.

Page 2 FoxGuard Manager provides an information interface alternative to the I/A Series Integrator 30 for Modbus devices, a Modbus interface which uses an RS-232-C connection between the TRICON and an I/A Series communication module. Like the Integrator 30, the FoxGuard Manager offers I/A Series users real-time access to safety system data. However, the FoxGuard Manager provides greater information integration between the I/A Series system and the controller, superior information data throughout performance, and improved diagnostic functions. The FoxGuard Manager supports a set of standard I/A Series software blocks (as listed in the Features section) plus a set of blocks specific to the FoxGuard Manager. It also supports peer-to-peer connections to other I/A Series blocks supporting calculation and display functions. These peer-to-peer connections can also be used to support loosely coupled control functions, but since the Integrator 30 for Modbus devices supports a fault-tolerant configuration option, it is the preferred interface for integrating I/A Series control applications with Triconex safety systems. FEATURES The FoxGuard Manager features include: Reliable, high-performance communication between the TRICON controller and the I/A Series Nodebus. Onboard firewall protection of TRICON setpoints, controller operation and I/O. The interface does not change the operation of the safety shutdown system, and in no way affects TUV certification. Support for the following standard I/A Series block types: ACCUM AIN AOUT BOOL CIN COUT LONG MAIN MCIN MCOUT MEALM MSG PACK REALM STA STALM STRING Support for standard I/A Series alarm functions. FoxGuard Equipment Control Block (ECB85), providing remote monitoring of TRICON operations and diagnostic information Configurable ECBs that enable access to TRICON memory, system and I/O aliases New I/A Series TRISOE block for Sequence of Events applications Object Manager read access to any TRICON alias value Ability to deny access through the firewall from either the Triconex side or the I/A Series environment. PACKAGING AND ARCHITECTURE The single module FoxGuard Manager interface consists of the Triconex ACM installed in a TRICON controller chassis and connected to the Nodebus via a DNBI. In the redundant configuration, two ACMs are installed in the same logical slot, and connected to the Nodebus with separate cabling and DNBIs. Communications Module The Advanced Communications Module (ACM) is an intelligent, multifunction communications device that can be installed in the TRICON main chassis or in Chassis #2 (which can be either an expansion chassis or RMX). The ACM plugs directly into the TRICON backplane and communicates with the main processors and other TRICON modules via the tripleredundant TRICON bus. All external connections are made via the front edge of the module. The I/A Series Nodebus connectors and indicators are arranged in the upper half of the card edge just below the TRICON module status indicators. In addition to providing the direct connect interface between the TRICON controller and the I/A Series environment, the ACM can be simultaneously used for a variety of Triconex protocols and applications including the Tristation protocol for the TRISTATION MSW programming system. Redundant Operation At redundant station startup, the FoxGuard Manager determines the operating mode for the ACM as either a monitoring station or a tracking station. As the monitoring station, it is responsible for all I/A Series Nodebus activity plus all control responsibilities. Further, the monitoring station is responsible for maintaining all peer-to-peer connection information and OM SET/WRITE information with the tracking station. The tracking station receives peer-to-peer updates from the monitoring station and performs all control responsibilities excluding issuing write requests to the TRICON. The redundant FoxGuard Manager stations periodically exchange station health information. When the redundant tracking detects a fault with the monitoring station, the tracking station assumes all monitoring responsibilities for the FoxGuard Manager station within 5 seconds. Further, when the station takeover occurs, all of the station s peer-to-peer connections are maintained.

Page 3 This is a loosely coupled redundant solution. I/A Series control strategies that involve time sensitive sequences should be implemented on a fault-tolerant control processor (CP) which interfaces with I/O directly connected to I/A Series systems. Since the Integrator 30 for Modbus devices supports a more tightly coupled interface to Triconex and is available in fault-tolerant configurations, it should be used as the interface for I/A Series control strategies that must interface with I/O on the Triconex system. Network Connections Each ACM is connected to the I/A Series Nodebus via a Dual Nodebus Interface (DNBI), the same interface used to connect remote 50 Series stations such as the Workstation Processor 51 and Application Processor 51. An attachment unit interface (AUI) cable provides for data transmission between each ACM and its DNBI (Figure 1). A separate RS-423 control cable between the modules enables the FoxGuard Manager to switch between two redundant Nodebus cables. The FoxGuard Manager also uses the control cable for ancillary functions such as controlling the DNBI front panel LEDs, verifying the status of the Nodebus transceivers, and reading the DNBI letterbug. The DNBI uses multiconductor cable with a maximum cabling distance of 50 meters (150 feet). MF F M AUI Cable P0970BM (6 feet) ABCD AUI Cable P0900ZU (10 feet) or P0900ZV (50 feet) or P0900ZW (150 feet) PASS FAIL ACTIVE I/A Series NODEBUS ONLINE SBRDY PASS FAIL ACTIVE I/A Series NODEBUS ONLINE SBRDY AUI Cable P0900ZU (10 feet) or P0900ZV (50 feet) or P0900ZW (150 feet) AUI Cable P0970BM (6 feet) ABCD TX RX TX RX Serial Cable P0971PE (6 feet) DNBX DNBX Serial Cable P0971PE (6 feet) M F Dual Nodebus Interface (DNBI) (P0970BC) Serial Cable P0912XT (10 feet) or P0913QA (50 feet) or P0913QB (150 feet) M F DNBI TX RX TS/TSAA DNBI TX RX TS/TSAA M F M F Serial Cable P0912XT (10 feet) or P0913QA (50 feet) or P0913QB (150 feet) Dual Nodebus Interface (DNBI) (P0970BC) ACM 4609 ACM 4609 Figure 1. FoxGuard Manager Front Panel Connections for DNBI Setup

Page 4 DISPLAYS The ACM with FoxGuard Manager software operates as a station on the I/A Series Nodebus in much the same way as a control processor operates, with a control database downloaded over the Nodebus. In addition to executing a variety of control applications, the FoxGuard Manager provides current TRICON status information in a default station display Figure 2) that replicates the TRISTATION diagnostic display. The FoxGuard ECB (ECB85), which is automatically downloaded with the FoxGuard Manager image when the ACM is initialized, builds the display by accessing the system aliases in the TRICON memory. The default station display includes an overlay for each chassis in the connected TRICON. Figure 2. FoxGuard Manager Station Display

Page 5 System Management Display Handler (SMDH) provides remote access to FoxGuard Manager operation with standard station, equipment information, and equipment change displays. For example, the FoxGuard Manager Equipment Information display (Figure 3) is a 2-level display with the FoxGuard Manager and the TRICON main processors on one level and the configured ECBs on the next level. The System Management displays enable the operator to download and checkpoint the FoxGuard Manager database, turn ECBs on and off, and view the operational status of TRICON modules. No equipment change action taken on the FoxGuard Manager affects operation of the safety system. The I/A Series interface can be shut down from the SMDH display, but operation of the TRICON cannot be turned off from the I/A Series side. Figure 3. FoxGuard Manager I/O Module Equipment Information Display

Page 6 FOXGUARD MANAGER SOFTWARE The FoxGuard Manager is partitioned into two domains, one controlled by the Triconex software and the other executing control programs configured and downloaded from the I/A Series system. The Triconex software provides an electronic firewall between the two domains to prevent unintended writes to TRICON process variables. Write access to the TRICON via the interface is under the complete control of the TRICON. Remote writes are allowed when the TRICON key switch is set to PROGRAM or REMOTE, or when the switch is set to RUN and gated access is enabled by the TRICON control program. Gated access allows writes to configured memory aliases within a time window defined in the TRICON program. In addition, the ACM can be defined as a read-only module by the TRISTATION module configuration program. Access through the firewall can be denied from the I/A Series system by turning off the FoxGuard Monitor ECB or the primary ECB. APPLICATIONS Using the Integrated Control Configurator, you can configure the FoxGuard Manager to execute control compounds. The compounds employ a set of standard I/A Series blocks and FoxGuard Manager specific blocks. These blocks provide data points for other I/A Series applications through peer-to-peer connections or Object Manager calls. With these resources, the FoxGuard Manager supports a variety of applications, including: Safety system monitoring Sequence of events processing Data scanning. Safety System Monitoring A key advantage of the FoxGuard Manager is that it allows the process operator to monitor safety system performance remotely using standard I/A Series displays and resources. As a Nodebus station, FoxGuard Manager operation is accessible through default displays which provide system health information about each TRICON module, and through the SMDH. The FoxGuard Manager also enables you to use TRICON diagnostic system aliases as sources for process alarms and state change messages. Sequence of Events Processing The TRICON system includes an integrated Sequence of Events (SOE) capability for system maintenance and shutdown analysis. During each scan of the control program, the main processors examine user-selected discrete variables for state changes, or events. The TRISTATION MSW program is used to configure SOE blocks which define the event variables and their alias numbers. SOE events can include discrete inputs, discrete memory readonly variables and discrete memory read/write variables. The TRICON allows the configuration of up to 14 SOE blocks for general use and two SOE blocks for specialized applications. With the FoxGuard Manager, you can create an I/A Series compound that configures one of the 14 TRICON general purpose SOE blocks, receives the event information configured in the block, and passes the data to a user-defined application for storage and analysis. The I/A Series compound consists of one or more FoxGuard Manager specific TRISOE blocks which identify the event variables to be used in the Triconex SOE block configuration. FoxGuard Manager software regulates the message flow to the analysis application to assure capture of all event information. Data Scanning The FoxGuard Manager block set includes two varieties of configurable ECBs for reading and writing TRICON process data: Four ECB types are provided for accessing data from the TRICON I/O modules similar to ECBs that are configured for I/A Series Fieldbus Modules and Cluster I/O Fieldbus cards. These I/O module ECBs provide both the process points and status information such as bad data and outof-range alarming. The process points in the ECBs are then connected to I/O type blocks which condition the data, convert the points to engineering units, and make them available to other blocks. Six ECB types are used to access aliases in the TRICON main processors. The window ECBs can be configured to read or write up to 16 non-contiguous process variables of the same data type. These window-type ECBs can be connected directly to other blocks without the use of I/O blocks.

Page 7 In addition to block connections, you can read TRICON process points with Object Manager calls by identifying the object using the I/A Series compound:block.parameter syntax. The compound is the <letterbug>_ecb, the block is the FoxGuard monitor ECB name, and the parameter is the TRICON alias number. Remote Control In its default configuration, the TRICON disables any remote writes to the controller program, relying instead on the TMR architecture to determine controller outputs. The FoxGuard Manager design protects the critical role of the TRICON controller while enabling you to enhance controller operation with inputs from I/A Series blocks. As an added measure of security, writes to the TRICON outputs can only be made through the configured ECBs and not through the Object Manager write command. Triconex Model 4609 Advanced Communications Module (ACM) Specifications For additional hardware information, contact your local Triconex sales representative.

Page 8 33 Commercial Street Foxboro, MA 02035-2099 United States of America www.foxboro.com Inside U.S.: 1-866-746-6477 Outside U.S.: 1-508-549-2424 or contact your local Foxboro representative. Facsimile: 1-508-549-4999 Invensys, Foxboro, I/A Series, and Triconex are trademarks of Invensys plc, its subsidiaries, and affiliates. All other brand names may be trademarks of their respective owners. Copyright 2000-2006 Invensys Systems, Inc. All rights reserved MB 21A Printed in U.S.A. 1006