MOLDED CASE CIRCUIT BREAKERS. SACE Tmax XT Break new ground UL and CSA Standards

Similar documents
SACE Tmax XT Break new ground

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

SMARTER BUILDING. Give your buildings a new dimension Scalable solutions for energy and asset management

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

Give your buildings a new dimension Scalable solutions for energy and asset management

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

SACE Emax 2 Specification guide

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

The Leviton Load Center THE FUTURE MADE CURRENT

The Leviton Load Center THE FUTURE MADE CURRENT

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Integration Fully integrated Controls, Power Monitoring, Generator Paralleling, and Switching Schemes as a complete turnkey solution.

ABB DATA CENTER FORUM 2017, 11 JULY 2017, TUESDAY Remote Power Panels with unique power density - giving you more in less space Nico Ninov, Market

Easy, efficient and always up to date the SIRIUS modular system

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

60103 Circuit Breaker

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Preliminary - 1SDC210013B0201. New Tmax T6. New PR223EF and PR223DS electronic releases.

DOC2 Release Notes. Release Fixed Bugs Fixed minor bugs in Curves module. Release What s New Minor improvements;

The 3VA molded case circuit breaker.

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Lowering Lifecycle Costs

8200 vector frequency inverter

3VA molded case circuit breaker up to 1600A. Frei verwendbar Siemens AG 2018

Modular, scalable, high-efficiency power protection for data centers

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Performance and Efficiency

Miniature circuit breakers for all applications

IZMX Series Air Circuit Breakers. Small, flexible, efficient

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Solid-State Switching Devices

HIGHLIGHTS Innovations for your success

DOC Electrical Installation Calculation and Dimensioning

MOTOR PROTECTION CIRCUIT BREAKERS

Innovations in the Sirius Modular System for greater efficiency in Industrial Controls and in control cabinet construction

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

Applying branch circuit breakers and supplementary protectors in North America

SAFE, FLEXIBLE, EASY CURRENT TRANSFORMER CURRENT TRANSFORMERS FOR THE SAFE MEASUREMENT OF HIGH CURRENTS

Innovation for MV distribution

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

Reasons to connect your tools

Square D Homeline Load Centers and Circuit Breakers. Engineered for value

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

SECTION DISCONNECT SWITCHES

F02 SERIES ELECTRIC ACTUATORS

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1

HIGHLIGHTS Innovations for your success

FLEXIBLE INTELLIGENT RACK POWER DISTRIBUTION. Contact. About Anord Mardix.

8200 vector frequency inverter

Tmax molded case circuit breakers Specification guide

Symmetra PX. Symmetra PX 48kW Scalable from 16kW to 48kW. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Having communication issues? Model 6 intelligent Motor Control Centers communicate on all platforms. Make the most of your energy SM

System solutions for your energy requirements

White paper - Preliminary. Emax 2, all-in-one innovation Interface Protection System and Interface Device

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

2440 Wireless SmartCart

Applying branch circuit breakers and supplementary protectors in North America

SIRIUS Motor Management and Control Devices

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

RB60 RANGE. Miniature circuit breakers

Newspaper plate production PRODUCT BROCHURE. Advanced solutions for low chemistry newspaper production, from PDF to plate

Model: KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

Seven Features You Didn t Expect from Your Bench DC Power Supply APPLICATION NOTE

Modular, scalable, high-efficiency power protection for data centers

Compact circuit breakers, with diagnosis included. Small, fl exible, effi cient.

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers

Masterpact MTZ circuit breakers. schneider-electric.com

CMControl R. Easy-to-use control device for CMC test sets for testing recloser and sectionalizer controls

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

Powerful, flexible management of water and wastewater systems. Flygt APP 800 pump and process controller

100% electricity. Automatic transfer switch controllers ATL series

Air & Moulded Case Circuit Breaker Service & Maintenance

Portable Power Solutions

Innovative features and solutions for SIVACON S8 siemens.com/sivacon-s8

Documentation. Mains filter AX2090-NF50. Version: Date:

A P P L I C A T I O N

VLT Micro Drive. Ready Set Go!

Datasheet: DSX CableAnalyzer Series

Xerox ConnectKey. The ecosystem for workplace productivity.

INTRODUCING THE S V ADJUSTABLE SPEED DRIVE

Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades

Power Management System. Multifunction Measuring Instruments

The complete universe of Industrial Controls. You have it at your fingertips. sirius

CBA 1000 CHARACTERISTICS

ADXL Series SIMPLE, EFFICIENT AND SAFE MOTOR CONTROL

Protected Power Supply for your Applications. Telecom Industrial Data Center

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

Circuit Breakers Type CTI 25M, CTI 45MB

Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection

CP30F Series Circuit Protector for Improving Safety and Wiring Workability

CBA HV Circuit Breaker Analyzer and Microhmmeter

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

Let Energy Monitoring Solutions Do the Heavy Lifting

Performance. Simplicity. Sepam, over 20 years of experience of the world leader. Sepam protection relays. For your peace of mind

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Transcription:

MOLDED CASE CIRCUIT BREAKERS SACE Tmax XT Break new ground UL and CSA Standards

S A C E T M A X X T M O L D E D C A S E C I R C U I T B R E A K E R S ( M C C B S U L & C S A S TA N D A R D S ) A molded case circuit breaker range that ensures extreme performance and protection features up to 1200A. Designed to maximize ease of use, integration and connectivity. Built to deliver safety, reliability and quality.

Table of contents 004 005 SACE Tmax XT 006 007 Added values 008 009 Key features 012 013 Choosing the right product 014 015 Accessories 018 021 Products in detail 024 025 Electronic trip units

4 SACE TMAX XT MOLDED CASE CIRCUIT BREAKERS (MCCBS UL & CSA STANDARDS) SACE Tmax XT The right choice for your purposes SACE Tmax XT7 SACE Tmax XT4 SACE Tmax XT2 SACE Tmax XT5

5 SACE Tmax XT3 SACE Tmax XT6 SACE Tmax XT1

6 SACE TMAX XT MOLDED CASE CIRCUIT BREAKERS (MCCBS UL & CSA STANDARDS) Added value each step of the way There is more to the SACE Tmax XT range than circuit breaking alone A new generation of molded case circuit breakers, characterized by the added value they deliver There is a lot more to the range of SACE Tmax XT than what meets the eye, and the benefits for your business are noticeable. To start with, the whole selection and ordering process has been overhauled to make it far easier to get your hands on the parts you need, speeding things up by about 30%. Installation has been simplified to increase user-friendliness, frames have been streamlined to save space, and improved connectivity - such as Bluetooth and Ekip mobile - will save you considerable time. Another additional benefit is the reliable cloud connectivity and overall increase in information available, meaning diagnostics and maintenance are vastly improved, resulting in less downtime. Finally, thanks to the smart power controller concept, overall energy consumption can be reduced by up to 20%.

ADDED VALUES 7 Selecting, ordering and handling 30% faster thanks to part numbers reduction (-10%), online configurator (-40% time) and smart packaging (-30% space). Speed up your projects Optimized logistics Speed up your projects Space saving Easy to install Commissioning The SACE Tmax XT range offers the potential to save serious time. Thanks to simplified installation of frames, integrating the circuit breakers into a communication network, trip unit settings performed via LCD and Bluetooth and Ekip Mobile connectivty, you stand to save up to 40% time overall. Diagnostics and maintenance With up to 30% more data available on the cloud and ABB unique power controller concept, it is far easier to diagnose problems and carry out necessary maintenance. This helps to prevent faults, restore energy more quickly and avoid any unnecessary charging of utilities. Optimum interface Safety and protection Continuous operation Continuous operation Energy efficiency Energy saving The SACE Tmax XT range comes with the exclusive ABB-patented Ekip Power Controller which monitors installation loads and can limit the amount of power consumed at any time. The result is an overall reduction in power consumption of up to 20% and lower energy bills. Furthermore, you have 1% energy measurement accuracy.

8 SACE TMAX XT MOLDED CASE CIRCUIT BREAKERS (MCCBS UL & CSA STANDARDS) Break new ground Key features of an outstanding product 01 Choose and customise exactly the right products for your needs, based on how you will use them. 10,000 solutions in one click 02 Effective energy management: 20% less power consumption with Power Controller enabled 03 Top reliability: Products designed and tested to exceed standard requirements. More than 30 certifications Cloud-connected Being connected is a key feature of today s technology and the SACE Tmax XT range of circuit breakers offers more than just standalone protection. Being considered key elements of an electrical distribution system, Tmax XT circuit breakers give you the ability to monitor and manage a wealth of information, easily, wherever you are. So even when on the road, anytime of the day or night, the power of full-access flexi bility is in your hands. Being able to monitor everything while being off-site provides a genuine feeling of you being in control at all times. Tailor-made solutions Just because your project is complex, this does not mean your circuit breaker setup has to be. All frames from XT1 to XT7 provide a common pro duct experience that is backed up by a comprehensive range of accessories with intuitive interfaces and ergonomic design. With maximum flexibility for every application, the SACE Tmax XT range offers you tailor-made solutions and sets the standards for electrical installations. Outstanding technology Flexibility is nothing without performance and the SACE Tmax XT range is able to deal with the most extreme breaking capacities, regardless of operating voltage, application, and environmental conditions. This, combined with the most precise electronic trip units in the smallest of frames, ensures continuity of service and equipment protection at all times. Top-level quality Almost a century of research and experience results in highly-reliable, top-level products that are ready to face all future challenges. Products like the SACE Tmax XT range set standards for edge technologies. Safety, product quality and reliability under pressure are fundamental to all ABB products and the SACE Tmax XT range is no different. Top-level reliability Cloud-connected Outstanding technology Tailor-made

9 01 02 03

EASE OF USE AND INSTALLATION Maximum flexibility for every application SACE Tmax XT sets standards for electrical installations. Easy selection, one-fits-all accessories and intuitive design pave the way for smart manufacturing of panels and fast upgrades. Even for the most critical projects.

12 SACE TMAX XT MOLDED CASE CIRCUIT BREAKERS (MCCBS UL & CSA STANDARDS) Choosing the right circuit breaker has never been so easy You consider what you need. We ll show you what is possible. The world of circuit breakers is a complex one, yet choosing the right device for your individual needs has never been simpler thanks to SACE Tmax XT range. Maybe you are looking for a basic protection device for a standard distribution plant. Or perhaps you need something more complex, such as a device that integrates protection, automation, measuring and communication into a cloud-based supervision system. Whatever you are looking for, with a wealth of customization possibilities and a range of possible solutions depending on the breaking part and trip unit you choose, the power of circuit breaking is firmly in your hands. Basic functionality Standard performance Icu 70kA at 480V AC Heavy duty Extreme breaking capacity 200kA at 480V AC 100kA at 600V AC Universally compatible Thermal-magnetic, Ekip Dip Ekip Touch Thermal-magnetic TMF-TMD-TMA-MF-MA Electronic Ekip DIP LS/I-LS/I+G-LSI-LSIG No communication/no display Ekip Touch LSI-LSIG Ekip Hi-Touch LSI-LSIG-Energy M Full connectivity - Advanced logic - Power management

CHOOSING THE RIGHT PRODUCT 13 Basic functionality low workloads Whether you are a hotel owner or planning a production line, where you need to consider the overall power voltage over a period of time, the whole SACE Tmax XT range offers all the circuit breaking power you need to keep your business running long into the future. Heavy duty high workloads When it comes to heavy duty usage whether it s ships, chemical parks, mining, or heavy duty machinery the SACE Tmax XT2, XT4, XT5 and XT7 frames are designed to work well beyond the normal constraints when you will be pushing the limits of your installation to the maximum. Thermal-magnetic, Ekip Dip manual operation This either consists of the standard thermal-magnetic trip unit intended for basic protection or the Ekip Dip trip unit, the first level of electronic trip unit that can provide increased accuracy, a wider regulation range, delayed short circuit protection and individual trip information. Ekip Touch cloud functionality Once you are working with the XT2, XT4 XT5 or XT7 frames, all activity can be remotely monitored via the cloud thanks to the Ekip Touch trip units which send all data to the ABB Ability TM EDCS and can be monitored through smartphone or tablet whenever and wherever you like. Possible combinations within the range Tmax XT1 Tmax XT2 Tmax XT3 Tmax XT4 Tmax XT5 Tmax XT6 Tmax XT7 Heavy duty Basic functionality Thermal-magnetic trip units Electronic trip units

14 SACE TMAX XT MOLDED CASE CIRCUIT BREAKERS (MCCBS UL & CSA STANDARDS) Accessories Expand the capabilities of the SACE Tmax XT range Integrating circuit breakers into any installation requires different levels of optimization. Whether physical, electrical, operational or safety-focused, accessories take SACE Tmax XT to the next level. Accessories A large range of connections has been conceived to match the most common distribution systems. Auxiliary contacts can provide precise information regarding breaker status and plant conditions, maximizing operator awareness and the overall accuracy of a supervision system. In addition, different types of coils and motor operator versions, designed to operate with the most common voltage sources and reduced power consumption, enable the possibility to control all installations remotely. Maintenance module, insulation stuff, double insulation and positive operation design are just a few examples of the care taken to safeguard appliances and operators alike.

ACCESSORIES 15 Various accessories are also available: 1. Breaking unit 2. Trip units 3. Front 4. Polish plate 5. Terminal covers 6. Auxiliary contacts 7. Key lock 8. Service releases 9. Communication module 10. Conversion kit for plug-in/ withdrawable versions 11. Guide of fixed part in the withdrawable version 12. Fixed part - FP 13. Front for lever operating mechanism - FLD 14. Stored energy motor operator - MOE 15. Direct rotary handle - RHD 16. Transmitted rotary handle - RHE 17. Conversion kit RHE > RHS 18. Cable rack 19. Phase separators 20. Rear orientated terminals - R 21. Front extended spread terminals - ES 22. Front terminals for copper-aluminium - FC CuAl 23. Front extended terminals - EF

PERFORMANCE AND PROTECTION Continuity of service and equipment protection SACE Tmax XT sets standards when extreme breaking capacity is needed. Sharing the same logics, interfaces and features regardless of operating voltage and environmental conditions. Embedding the most advanced protection into the smallest of frames.

18 SACE TMAX XT MOLDED CASE CIRCUIT BREAKERS (MCCBS UL & CSA STANDARDS) The SACE Tmax XT range at a glance The world of breaking capability in your hands. According to UL 489 and CSA C22.2 Standards The SACE Tmax XT range takes circuit breaking to the next level. Designed to perform at extremely high levels, simple to install and able to provide increasingly better safety, there is a frame to meet each and every one of your requirements. From a basic solution for standard applications - such as hotels - through to advanced, heavy-duty applications with cloud connectivity for ships, chemical parks or airports, the new range has got it covered: securely, professionally, reliably. SACE Tmax XT1 The founder Small, reliable, versatile. Your reliable partner for all standard applications. At a glance: Up to 125A For low workflows Dimensions 3 x 2.75 x 5.12 (WxDxH in) Thermal-magnetic trip unit SACE Tmax XT2 The aspirer Compact yet powerful. It fits everywhere and able to deal with all complex tasks. At a glance: Up to 125A For high workflows Dimensions 3.54 x 3.25 x 5.12 (WxDxH in) Thermal-magnetic, Ekip Dip, Ekip Touch

PRODUCTS IN DETAIL 19 SACE Tmax XT3 The workhorse Small and experienced. For standard applications that need few efforts. At a glance: Up to 225A For low workflows Dimensions 4.13 x 2.75 x 5.90 (WxDxH in) Thermal-magnetic trip unit SACE Tmax XT4 The entrepreneur A forward-thinking, multitasker. It finds solutions for all levels of complexity. At a glance: Up to 250A For high workflows Dimensions 4.13 x 3.25 x 6.3 (WxDxH in) Thermal-magnetic, Ekip Dip, Ekip Touch

20 SACE TMAX XT MOLDED CASE CIRCUIT BREAKERS (MCCBS UL & CSA STANDARDS) The SACE Tmax XT range at a glance The world of breaking capability in your hands. According to UL 489 and CSA C22.2 Standards SACE Tmax XT5 The gamechanger Compact, extremely powerful and flexible. It shows the world what a circuit breaker of the future can do, today. At a glance: Up to 600A For high workloads Dimensions 5.51x4.07x8.07 (WxDxH in) Thermal-magnetic, Ekip Dip, Ekip Touch SACE Tmax XT6 The carpenter Built to last. It completes all assignments it has been entrusted with. At a glance: Up to 800A For low workflows Dimensions 8.26x4.07x10.55 (WxDxH in) Thermal-magnetic, Ekip Dip

PRODUCTS IN DETAIL 21 SACE Tmax XT7 The superhero The ultimate choice. It deals with the most heavy-duty demands effortlessly. At a glance: Up to 1200A For high workflows Dimensions 8.26x6.53x10.55 (WxDxH in) Ekip Dip, Ekip Touch SACE Tmax XT7 M The motorized superhero The ultimate choice, with motor. It deals with the most heavy-duty demands smoothly. At a glance: Up to 1200A For high workflows Dimensions 8.26x7x10.55 (WxDxH in) Ekip Dip, Ekip Touch

DATA AND CONNECTIVITY Plant management of the future SACE Tmax XT sets standards in modern plant and energy management. Access, monitor and control information remotely, anywhere, at any time. Improving efficiency and saving energy.

24 SACE TMAX XT MOLDED CASE CIRCUIT BREAKERS (MCCBS UL & CSA STANDARDS) Electronic trip units Ekip Dip and Ekip Touch The network under control When it comes to accurate protection of the network, you cannot go wrong with Ekip Dip and Touch technology. Trip unit range The protection units available for the SACE Tmax XT range is organized in three layers, characterized by increasing performance, interfaces, information sets and integration functions. Each layer includes several trip unit versions, designed to match specific application needs such as distribution, generator protection and motor protection. Touch Dip TM Applications Advanced functionalities Distribution Motor Generator Selectivity Metering Communication ABB Ability Marketplace TM DC AC 01 All the tools needed to set up a competent and effective energy management strategy. 30% more information about a running system to empower ABB Ability TM Thermal-magnetic trip units Thermal-magnetic trip units are intended for the protection of AC and DC networks. They are a solution for basic protection such as overloads and short-circuits. Ekip Dip trip units Ekip Dip trip units represent the first level of electronic trip unit and are used to protect AC networks. Compared to thermal-magnetic trip units, they can provide increased accuracy, a wider regulation range, delayed short circuit protection, indi vidual trip information and test capability. Ekip Touch trip units Ekip Touch trip units offer state-of-the-art technology for AC-network protection. These trip units integrate a great number of protection and automation functionalities, performed with bestin-class accuracy. Measurement and supervision data can be transmitted both on the local communication network (the most popular communication protocols are available) or directly over the Internet. Configuration of the trip unit is extremely user-friendly, mainly on the sizes where a colour touchscreen display is available. Furthermore, as operational requirements evolve, for the first time ever customers can download new functions from the ABB MarketPlace, choosing among more than fifty different protection, metering and automation functionalities. Protection and information Thermal-magnetic Ekip Dip Ekip Touch Accuracy

QUALITY AND RELIABILITY Absolute attention to detail, with style from design to manufacturing, SACE Tmax XT sets standards for edge technologies. Almost a century of research and experience means top-level products that are ready to face future challenges.

ABB SACE Protection & Connection 5, Via Pescaria I-24123 Bergamo - Italy Phone: +39 035 395-111 go.abb/xt Copyright 2018 ABB. All rights reserved. Specifications subject to change without notice. 9AKK107046A6528-09/2018