C B. Models. Operating up to 5000m altitude 5 year product warranty

Similar documents
C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

TEP 75WI Series, 75 Watt

TEP 100WIR Series, 100 Watt

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

Universal Power Supplies

Enclosed Power Supplies

POWERBOX Industrial Line PMR20W Series 20W 4:1 Single and Dual Output High Performance DC/DC Converter

PXC-M06xxW Dual Output Series: DC-DC Converter Module 9 ~ 36 VDC and 18~ 75 VDC input; ±5 to ±15 VDC Dual Output 6 Watts Output Power

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Over Current and Over Voltage Protection No Minimum Load Required

DC-DC CONVERTERS SINGLE OUTPUT, 60 WATTS EXTREMELY WIDE 12:1 INPUT VOLTAGE RANGE: 9-75VDC, VDC RAILWAY APPLICATIONS

FDC20-48 S 05 W - HC PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Features. Regulated Converters. RP10-AW 10 Watt 1 x1 Single & Dual Output RP10- _AW/_- DC/DC Converter

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Fixed Operating Frequency Six-Sided Continuous Shield

Package (4) Control Logic (3)

Packaging (5) Protection (3) Isolation Voltage (4)

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 84% Fixed Operating Frequency Six-Sided Continuous Shield

DC/DC Converters. TSM Series, 1 Watt. Features. Models

2:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 88% Ultraminiature Open Frame SMD No Minimum Load Required

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Output Voltage* (nom.)(adjustable)

Packaging (4) Isolation Voltage (3) nom. Output Voltage

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 89% Six-Sided Continuous Shield

MB2000ERUI. High Isolation, 1 x 2 20W, 4:1 Input Range DC/DC Con vert ers. Key Features:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Universal input VAC <150mW No load power consumption

IEC/EN/UL60950 & CE certified, EN55032 Class B

Output Voltage* (nom.)(adjustable)

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Output Current Input Current Max. capacitive Load

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

Switching Power Supplies

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

20W DC-DC Converter P20J-Series

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

VP ELECTRONIQUE MASSY - Tel

Series AM1M-NZ 1 Watt DC-DC Converter

MI1000ERW. Series. Miniature 1 x 1, 2:1 Input, 10W DC/DC Con vert ers. Key Features:

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

IG480RW. Series. High Isolation IGBT Driver DC/DC Con vert ers.

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

MPV1560RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

R0.5S_D ECONOLINE. Features. 0.5 Watt SMD Isolated Single or Dual Output. Derating-Graph (Ambient Temperature) DC/DC-Converter with 3 year Warranty

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM40-G)

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

ML100SRI. Series. Ultra-Miniature, 1W High Isolation, SMT DC/DC Con vert ers. Key Features:

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Protection (3) alternative Pinning Option (4) Single or Dual

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

RO- S/_ Protection (3) Isolation Option (4) Single

Series AM1S-Z 1 Watt DC-DC Converter

RM- S/_ Protection (3) Isolation Option (4) Single

Industrial Power Supplies

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

Series AM20EW-NZ 20 Watt DC-DC Converter

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

Vin= 24VDC Vout= full load with normal start-up time, no external components with <1 second start-up time + diode protection circuit

Safety Standards. Model Number:

FEATURES. Nominal Output Voltage and Current

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Datasheet. ACF-10 Series AC/DC Power Module 10W

Safety Standards. Model Number:

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

20W DC-DC Converter P20H-Series

Safety Standards. Model Number: Unit Weight:

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Safety Standards. Model Number:

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Series AM4T-Z 4 Watt DC-DC Converter

Safety Standards. Model Number:

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Safety Standards. Model Number:

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Transcription:

DC/DC Converter Wide 2:1 input voltage 10 W DC/DC converter in a compact DIP-24 plastic case I/O isolation 5000 VACrms rated for 250 VACrms working voltage Certification according to IEC/EN/ES 60601-1 3rd edition for 2xMOPP Risk management process according to ISO 14971 including risk management file Acceptance criteria for electronic assemblies according to IPC-A-610 Level 3 Low leakage current < 2µA Extended operating temperature range 40 C to 90 C. EMC compliance to IEC 60601-1-2 4th edition and EN55032 class A Operating up to 5000m altitude 5 year product warranty Models THM 10 Series, 10 Watt ES 60601-1 The THM-10 series is a range of medical 10 Watt DC/DC converters in DIP-24 plastic package and with wide 2:1 input voltage range. They provide a reinforced isolation system for 5000 VACrms isolation and a very low leakage current of less than 2 µa. The units are approved to IEC/EN/ES 60601-1 3rd edition for 2 x MOPP (Means Of Patient Protection) and come along with an ISO 14971 risk management file. Design and production conform to the quality management system ISO 13485. With a high efficiency of up to 89% and highest grade components the converters can reliably operate in an ambient temperature range of 40 C up to +90 C. They constitute a reliable solution not only for medical equipment but also for demanding ranges of application such as transportation, control & measurement or IGBT drivers. C B Scheme IEC 606010-1 Order code* Input voltage range Output voltage Output current max. Efficiency typ. THM 10-0510 3.3 VDC 2500 ma 80.0 % THM 10-0511 5.0 VDC 2000 ma 84.0 % THM 10-0512 12 VDC 830 ma 86.5 % THM 10-0513 4.5 9 VDC 15 VDC 670 ma 87.0 % THM 10-0515 (5 VDC nominal) 24 VDC 416 ma 85.5 % THM 10-0521 ±5.0 VDC ±1000 ma 83.0 % THM 10-0522 ±12 VDC ±416 ma 85.5 % THM 10-0523 ±15 VDC ±333 ma 86.5 % THM 10-1210 3.3 VDC 2500 ma 83.0 % THM 10-1211 5.0 VDC 2000 ma 85.5 % THM 10-1212 12 VDC 830 ma 88.0 % THM 10-1213 9. 0 18 VDC 15 VDC 670 ma 89.0 % THM 10-1215 (12 VDC nominal) 24 VDC 416 ma 89.0 % THM 10-1221 ±5.0 VDC ±1000 ma 84.0 % THM 10-1222 ±12 VDC ±416 ma 89.0 % THM 10-1223 ±15 VDC ±333 ma 88.0 % THM 10-2410 3.3 VDC 2500 ma 83.0 % THM 10-2411 5.0 VDC 2000 ma 86.5 % THM 10-2412 12 VDC 830 ma 89.0 % THM 10-2413 18 36 VDC 15 VDC 670 ma 89.0 % THM 10-2415 (24 VDC nominal) 24 VDC 416 ma 89.0 % THM 10-2421 ±5.0 VDC ±1000 ma 85.0 % THM 10-2422 ±12 VDC ±416 ma 89.0 % THM 10-2423 ±15 VDC ±333 ma 88.0 % THM 10-4810 3.3 VDC 2500 ma 82.5 % THM 10-4811 5.0 VDC 2000 ma 86.5 % THM 10-4812 12 VDC 830 ma 89.0 % THM 10-4813 36 75 VDC 15 VDC 670 ma 89.0 % THM 10-4815 (48 VDC nominal) 24 VDC 416 ma 88.5 % THM 10-4821 ±5.0 VDC ±1000 ma 85.0 % THM 10-4822 ±12 VDC ±416 ma 88.0 % THM 10-4823 ±15 VDC ±333 ma 88.0 % * suffix -B2 for trim option with adjustable output suffix -B3 for remote control option suffix -B4 for trim + remote-control option www.tracopower.com Page 1 of 5

Input Specifications Input current no load Surge voltage (3 s max.) Start-up voltage Startup time Under voltage shut down 5 Vin models: 20 ma typ. 12 Vin models: 10 ma typ. 24 Vin models: 6 ma typ. 48 Vin models: 4 ma typ. 5 Vin models: 16 V max. 12 Vin models: 25 V max. 24 Vin models: 50 V max. 48 Vin models: 100 V max. 5 Vin models: 4.5 VDC (or lower) 12 Vin models: 9 VDC (or lower) 24 Vin models: 18 VDC (or lower) 48 Vin models: 36 VDC (or lower) 30 ms typ. 5 Vin models: 3 4.4 VDC 12 Vin models: 7 8.8 VDC 24 Vin models: 15 17.5 VDC 48 Vin models: 31 34.5 VDC Conducted noise Conducted & Radiated input suppression EN 55011 limits to IEC 60601-1-2 4th editon EN 55032 class A (internal filter) EN 55032 class B (with external components) Filter proposal for compling to EN 55032 class B www.tracopower.com/overview/thm10 EMC immunity Generic for Medical equipment IEC/EN 60601-1-2 4th edition ESD (electrostatic discharge) EN 61000-4-2, air ±8 kv, contact ±6 kv, perf. criteria A Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A Fast transient / surge EN 61000-4-4, ±2 kv, perf. criteria A (with external input capacitor / diode) EN 61000-4-5, ±2 kv perf. criteria A 5 Vin models: Nippon chemi-con KY 1000 µf/ 25 V and reverse diode (Vishay V10P45) in parallel 12 & 24 Vin models: Nippon chemi-con KY 470 µf/ 50 V 48 Vin models: Nippon chemi-con KY 330 µf/ 100 V Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A Magnetic field immunity EN 61000-4-8 100 A/m, continuous, perf. criteria A 1000 A/m, 1 sec., perf. criteria A External input fuse required (recommended values, slow blow type) 5 Vin models: 5 A 12 Vin models: 2 A 24 Vin models: 1 A 48 Vin models: 0.5 A www.tracopower.com Page 2 of 5

Output Specifications Voltage set accuracy ±1 % max. Output voltage adjustment (for THM 10 -B2 / -B4 option models only) Single output 15 & 24 Vout models: 10 / +20% other models: ±10% Dual output 5, 12 & 15 Vout models: ±10% Regulation Input variation single output: 0.2 % max. dual output: 0.5 % max. Load variation 0 100 % single output: 0.2 % max. dual output: 1.0 % max. Cross regulation dual output: 5.0 % max. (asymmetrical load 25/100 %) Minimum load Ripple and noise (20 MHz Bandwidth) not required 3.3 & 5.0 VDC models: 30 mvp-p typ. with cap. 10 µf/25 V X7R MLCC 12 & 15 VDC models: 40 mvp-p typ. with cap. 10 µf/25 V X7R MLCC 24 VDC models: 50 mvp-p typ. with cap. 4.7 µf/50 V X7R MLCC Transient response (25% load step change) Recovery time 250 µs typ. Over current limitation Short circuit protection at 150 % typ. of Iout rated (hiccup mode) Continuous, automatic recovery Over voltage protection Single output 3.3 VDC models: 3.7 5.0 VDC 5.0 VDC models: 5.6 7.0 VDC 12 VDC models: 13.5 16.0 VDC 15 VDC models: 18.3 22.0 VDC 24 VDC models: 29.1 34.5 VDC Dual output ±5 VDC models: 5.6 7.0 VDC ±12 VDC models: 13.5 18.2 VDC ±15 VDC models: 17.0 22.0 VDC Capacitive load Single output 3.3 VDC models: 3 000 µf max. 5.0 VDC models: 2 500 µf max. 12 VDC models: 430 µf max. 15 VDC models: 350 µf max. 24 VDC models: 125 µf max. Dual output ±5 VDC models: 1 440 µf max. (each output) ±12 VDC models: 250 µf max. (each output) ±15 VDC models: 180 µf max. (each output) All specifications valid at nominal input voltage, full load and +25 C after warm-up time unless otherwise stated. www.tracopower.com Page 3 of 5

General Specifications Temperature ranges Operating 40 C to +90 C (with derating) Rated according to IEC/EN 60601-1 40 C to +50 C (without derating) Case temperature +105 C max. Storage temperature 55 C to +125 C Derating 3.5 %/K above 75 C Thermal impedance Humidity (non condensing) 18 K/W typ. 5 % to 95 % rel H max. Isolation voltage to meet ES/IEC/EN 60601-1 5000 VACrms, rated for 250 VACrms working (50Hz, 60sec) voltage, 2 x MOPP Clearance/creepage Leakage current ( at 240 VAC, 60 Hz) Isolation capacitance (input/output) Altitude during operation Temperature coefficient Reliability, calculated MTBF (MIL-HDBK-217F at +25 C, ground benign) Switching frequency Vibration and thermal shock resistance 8 mm min. 2 µa max. 17 pf max. 5000 m ±0.02 %/K typ. 3 850 000 h 300 khz ±30 khz (pulse width modulation) according to MIL-STD-810F Remote On/Off (for THM 10 -B3 / -B4 option models only) Off 2.2 12 VDC (referred to -Vin pin) On open circuit or 0 1.2 VDC (referred to -Vin pin) Off idle current 2.5 ma typ. Remote pin input current 0.5 ma min. 1 ma max. Safety standards/approvals Medical equipment ANSI/AAMI ES60601-1:2005/(R)2012, IEC/EN60601-1 3rd edition Certification documents www.tracopower.com/overview/thm10 Environmental compliance Reach www.tracopower.com/info/reach-declaration.pdf RoHS RoHS directive 2011/65/EU Physical Specifications Casing material Base material Potting material Package weight Soldering temperature non-conductive black plastic non-conductive black plastic silicone (UL94 V-0 rated) 14 g (0.48oz) max. 265 C / 10 sec - The component is not be used in an oxygen rich environment. - The component is not to be used in conjunction with flammable anaesthetics and agents. - The component has to be disposed appropriately. Please refer to local regulations (Waste Electrical and Electronic Equipment). - A modification of the component is not allowed. All specifications valid at nominal input voltage, full load and +25 C after warm-up time unless otherwise stated. www.tracopower.com Page 4 of 5

Outline Dimensions Standard pinning Standard Pinout 1 24 23 Bottom view 31.8 (1.25) 11 12 15 13 (0.60) 15.24 (0.80) 20.3 Pin Single Dual 1 +Vin (Vcc) +Vin (Vcc) 11 No pin Common 12 Vout No pin 13 +Vout Vout 15 No pin +Vout 23 Vin (GND) Vin (GND) 24 Vin (GND) Vin (GND) 3.8 (0.15) 10.2 (0.40) 2.0 (0.08) 20.32 (0.80) 2x (2x0.1) Optional pinning with options: suffix -B1 (alternative pinning); -B2 (with Trim); -B3 (with Remote); -B4 (with Trim and Remote) Optional Pinout 1 2 23 22 10 11 Bottom view 16 14 31.8 (1.25) (0.60) 15.24 (0.80) 20.3 Pin Single Dual 1 No Pin*/Remote No Pin*/Remote 2 Vin (GND) Vin (GND) 10 No Pin*/Trim No Pin*/Trim 11 No con. Vout 14 +Vout +Vout 16 Vout Common 22 +Vin (Vcc) +Vin (Vcc) 23 +Vin (Vcc) +Vin (Vcc) 2.0 (0.08) 15.24 (0.60) 10.2 (0.40) 3.8 (0.15) *If Remote or Trim is not selected there is no pin on corresponding number. Remark: No suffix -Bx for 5 Vin models. Corresponding parts are with THM 10WI series by default. see www.tracopower.com/overview/thm10wi Dimensions in [mm], () = Inch Tolerances ±0.5 (±0.02) Pin ø 0.6 ±0.1 (0.024 ±0.004) Pin pitch tolerances ±0.25 (±0.01) Copyright 2018 Traco Electronic AG Specifications can be changed without notice! www.tracopower.com Rev. October 30, 2018 Page 5 of 5