COMMERCIAL ITEM DESCRIPTION SPECIFICATION SHEET CONNECTORS, FIBER OPTIC, SINGLE FIBER, SMALL FORM FACTOR, LC TYPE

Similar documents
DETAIL SPECIFICATION SHEET CONNECTOR, FIBER OPTIC, SINGLE TERMINUS, PLUG, BAYONET COUPLING (ST STYLE), 2.5 MILLIMETERS DIAMETER FERRULE, EPOXY

METRIC MIL-C-83522/16B w/amendment 1 17 AUGUST 2004 SUPERSEDING MIL-C-83522/16B 11 May 1995 MILITARY SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

Emerging Fiber Termination Solution

DEFENSE LOGISTICS AGENCY LAND AND MARITIME P.O. BOX 3990 COLUMBUS, OHIO

CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR SIMPLEX OPTICAL FIBER (MULTIMODE) NO-EPOXY, NO-POLISH CONNECTORS

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

CONNECTOR SOLUTIONS. FASTConnect FUSEConnect Field Master

Singlemode SC Connector Kits Polymer Crimp Body. Housing Boot. 3.0 mm Jacketed. Simplex Blue Blue. Duplex Blue Blue

Connector SPECIFICATION SINGLEMODE MULTIMODE. 126μm +1/-0 Concentricity: 1μm. 127μm 125μm +1/-0 Concentricity: : 1μm

DIAMOND Fiber Optic Components

A wide range of connectors are available to fit very specific needs.

EC Series LC Connectors

DETAIL SPECIFICATION SHEET. INTERCONNECTION BOX, CABLE ROUTING, FIBER OPTIC, SPRAYTIGHT, 712 X 1017 mm

SC/APC Connector. CATV Active device Telecommunication. Metro Local Area Data processing

Expanded SECURE Connector Product Line Includes MPO and LC Interfaces

Table 1. Termini Types

PERFORMANCE SPECIFICATION SHEET CONNECTORS, PLUG, ELECTRICAL, COAXIAL, RADIO FREQUENCY, (SERIES N (CABLED), PIN CONTACT, CLASS 2)

Product information 19" 1U UniRack2 24xLC-Duplex G.652.D, PC, ceramic, C/2 R819330

LC Connectors. Fiber Optic Products Catalog. One-Piece LC Connector Product Facts

DIAMOND Fiber Optic Components

Fiber Optic Connectors and Cables. Rugged High-Bandwidth Mil-Aero Grade

Instruction Manual R&M Connectors. R&M Fiber Optic Components. System security for future requirements. Version 2.4

Product information 19" 1U UniRack 24xLC-Duplex OM4, PC, ceramic, Bm/3 R816749

FEATURED PRODUCTS SC & LC MINI BOOTS LC-HD TOP ADAPTER XP-SERIES LC SWITCHABLE UNIBOOT IP-SERIES LC-KEYED FLEX BOOTS PLC-WDM

13-SDMS-01 REV SDMS-01, REV.00 SEC DISTRIBUTION MATERIALS SPECIFICATION DATE: G

PERFORMANCE SPECIFICATION SHEET CONNECTORS, COAXIAL, RADIO FREQUENCY, SERIES C (UNCABLED-RECEPTACLE, FEMALE, JAM NUT MOUNTED, HERMETIC SEAL, CLASS 2)

LC Adapters and Cable Assemblies

PERFORMANCE SPECIFICATION SHEET SWITCH, ASSEMBLIES, SENSITIVE, INTERLOCK, UNSEALED

SPECIFICATION SINGLEMODE MULTIMODE. Premium Connector 0.08dB Typical 0.15dB Typical Standard Connector 0.12db Typical 0.20db Typical Return Loss

Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications

Crimplok ST* and SC Non-Adhesive Fiber Optic Single & Multi-mode Connectors

UniCam High-Performance Connectors, Multimode and Single-Mode

DETAIL SPECIFICATION SHEET

White Paper. FASTConnect or FUSEConnect Which Should You Choose? ABSTRACT INTRODUCTION. Tom Jeffers, Associate Product Manager, AFL

PERFORMANCE SPECIFICATION ADAPTER, CONNECTOR, COAXIAL, RADIO FREQUENCY, (BETWEEN SERIES SMA TO SERIES TNC), CLASS 2, STRAIGHT PLUG

PERFORMANCE SPECIFICATION SHEET SWITCHES, SENSITIVE, SPDT, LEAF ACTUATOR, LOW LEVEL TO 4 AMPERES, HERMETIC SEAL

Mission Critical Fiber Optic Solutions

Anaerobic-Cure Connectors

LC Connector. A High Density Fiber Optic Network Solution. Paul Kolesar Lucent Technologies, Bell Laboratories

OPTICAL CONNECTOR CONTAMINATION

OPTICAL CABLE & CABLE ASSEMBLY

Plug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2)

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

C o n n e c t o r s C h a p t e r 183

3 No Polish LC 50um Multimode Connector Environmental and Mechanical Test Report

DETAIL SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

Volition. Multimode VF-45 Socket and Patch Cords. 3Innovation

MILITARY SPECIFICATION

DETAIL SPECIFICATION SHEET

LC Connectors and Adapters

Panduit Certified Installer. Fiber Certification Review

Volition. VF-45 Singlemode Socket and Patch Cords. 3Innovation IT'S AS EASY AS PLUGGING IN AN RJ-45.

PERFORMANCE SPECIFICATION SHEET

Product Catalogue. Fibre Optic Components

Product Bulletin PB 308

PATCH-CORD. SC Patch-Cord APPLICATIONS AVAILABILITY FEATURES SPECIFICATIONS. Active device termination Local Area Networks (LANs)

Verizon 2007 All Rights Reserved Information contained herein is subject to change without notice.

A Division of Castle Microwave. Fibre Products.

EDGE Solutions Trunk Cable, SMF-28 Ultra OS2, MTP to MTP, 12 fibres

RUGGEDIZED HIGH-DENSITY OPTICAL INTERCONNECTS FOR HARSH ENVIRONMENTS

High Precision Fusion Splicer

PERFORMANCE SPECIFICATION SHEET

Optical Fiber Systems. Optical Fiber. Premise Connectivity Systems S Y S T E M S

Applications Engineering Notes. The US Conec MTP Multifiber Connector

LuxCis fiber optic interconnect solutions. ARINC 801, EN F725 Series

F-LINK INTER-CONNECT. Overview. Background. F-LINK Inter-Connect Solution

PERFORMANCE SPECIFICATION SHEET SWITCHES, PUSH, 2 CIRCUIT AND DPDT, ALTERNATE AND MOMENTARY ACTION, 2 AMPERES, SPLASHPROOF

DETAIL SPECIFICATION SHEET

EDGE Solutions Hybrid Trunk, OM4, Low- Loss, MTP to LC Duplex Uniboot, 24 fibres

3M Fiber Interconnect Solutions. The Network of Networks. High. Performance. Fiber Connections

DETAIL SPECIFICATION SHEET

LC Product Specification

PRODUCT SPECIFICATION. This specification defines the detailed requirements for the Minitek Pwr3.0 wire to wire and wire to board connectors.

Introduction to optical fibers and their applications

DETAIL SPECIFICATION SHEET

FTTH SOLUTION. Content. Contral. Apartment. house. house 13P. 11P Adapter 11P 10P 11P 13P 13P. 10P Mechanical Splice 11P 10P 11P 14P 10P.

Heat-Cure Single-Fiber Connectors A LANscape Solutions Product

SC Connector Family A Complete Fiber Optic Connector Solution

Ultra Low Loss (ULL) LazrSPEED 550 OM4 LC to LC, Fiber Patch Cord, 1.6 mm Duplex, LSZH

1 : LC/PC 0 : None S : Simplex 09 : 0.9mm G : Green W : White. A : LC/APC S : SM D : Duplex 20 : 2.0mm L : Blue. M : MM 30 : 3.

F-3000 connector family SFF reliable optic connections.

LX.5 (SFOC 1.25) High packing density. High performance. High reliability. High safety. High flexibility

Splice Trays An Evolant Solutions Product

SC Type Fiber Optic Connectors

New PHD Technology Yields Higher Density, Lower Optical Loss Interconnect Solutions

PERFORMANCE SPECIFICATION SHEET

Fiber Termination Where we ve been and where we re going. Lylette Macdonald, RCDD Legrand Ortronics

AEROSPACE, DEFENSE & MARINE /// MC801 FIBER OPTIC CONNECTORS

DIAMOND Fiber Optic Components

FC Type Connector. Standards YD/T IEC GR-326-CORE

FC Type Fiber Optic Connectors

PERFORMANCE SPECIFICATION SHEET. HEADSET-MICROPHONE, HEARING PROTECTIVE TYPE HIGH AMBIENT NOISE LEVELS, db, M87819/1-01

Data Center & Cloud Computing Infrastructure Solutions DATASHEET. MTP/MPO-LC/SC Cassette High-density Pre-terminated Modular Cassette System

VF-45 TM (SG) Ferrule-Less Interconnect Proposal

FuseLite Single-Fiber Splice-On Connectors

Transcription:

METRIC A-A-59940/ 9 ovember 203 COMMERCIAL ITEM DESCRIPTIO SPECIFICATIO SHEET COECTORS, FIBER OPTIC, SIGLE FIBER, SMALL FORM FACTOR, LC TYPE The General Services Administration has authorized the use of this commercial item description (CID), for all federal agencies. The requirements for acquiring the product described herein shall consist of this specification sheet and A-A-59940. CLASSIFICATIO: This CID uses a classification system that is included in the Part or Identification umber (PI). TABLE I. Termination process. Termination process Designation Epoxy polish Quick-connect fusion splice 2 Quick-connect mechanical splice 3 TABLE II. type. Fiber cable class MM UPC (graded-index, glass core and glass cladding, multimode) SM UPC (dispersion-unshifted, glass core and glass cladding, single-mode) SM APC (dispersion-unshifted, glass core and glass cladding, single-mode) Designation (or MM) 2 (or SM) 3 (or APC) TABLE III. :. designation Operating temperature on-operating temperature Storage temperature C ( F) C ( F) C ( F) -28 to +65 (-8.4 to +49) -40 to +70 (-40 to +58) -40 to +70 (-40 to +58) Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: Commander, aval Sea Systems Command, ATT: SEA 05S, 333 Isaac Hull Avenue, SE, Stop 560, Washington avy Yard DC 20376-560 or emailed to CommandStandards@navy.mil, with the subject line Document Comment. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https://assist.dla.mil. FSC 6060

TABLE IV. Housing type configurations. Fiber cable class Simplex one optical fiber/ferrule/single ferrule Duplex one optical fiber/ferrule/two ferrules Designation S D Pull-proof Strain relief design on-pull-proof 2/ TABLE V. Strain relief. Designation OTES: A connector with pull-proof type strain relief is designed to be used with cable considered to be of non-tight construction. This includes furcation units in accordance with A-A-59729 (2 to 2.4 mm in diameter). 2/ A connector with non-pull-proof type strain relief is designed to be used with cable considered to be of tight construction. This includes cable in accordance with MIL-PRF-85045/6 (2 mm in diameter). P Part or Identification umber (PI). AA59940 /0 - X X X X X CID number Specification sheet Termination process (, 2, or 3) (see table I) type (, 2, or 3) (see table II) () (see table III) Housing (S or D) (see table IV) Strain relief ( or P) (see table V) PI example: AA59940/0-S is an LC connector for buffered fiber and tight structured OFCC, multimode fiber, simplex housing, operating temperature of -28 to +65 C (-8.4 to +49 F), ultra physical contact polish, and epoxy polish termination method. configuration number TABLE VI. code configuration number: termination process: epoxy polish. Termination process (see table I) type (see table II) (see table III) Housing (see table IV) Strain relief (see table V) S SP P Simplex (S) 2 S 2 SP P D DP P Duplex (D) 2 D 2 DP P 2

configuration number TABLE VII. code configuration number: termination process: fusion splice. Termination process (see table I) type (see table II) (see table III) Housing (see table IV) Strain relief (see table V) 2S 2 SP P 22 S Simplex (S) 22 SP P 23 S SM APC (3) 23 SP P 2 2 D 2 DP P 22 D Duplex (D) 22 DP P 23 D SM APC (3) 23 DP P configuration number TABLE VIII. code configuration number: termination process: mechanical splice. Termination process (see table I) type (see table II) (see table III) Housing (see table IV) Strain relief (see table V) 3 S 3 SP P 32 S Simplex (S) 32 SP P 33 S SM APC (3) 33 SP P 3 3 D 3 DP P 32 D Duplex (D) 32 DP P 33 D SM APC (3) 33 DP P 3

DESIG AD COSTRUCTIO Interface dimensions. The interface dimensions of the LC connector shall be in accordance with TIA-604-0 [Fiber Optic Intermateability Standards (FOCIS 0)]. FIGURE. Size. Dimension OTES: 2/ TABLE IX. Fiber/cable type compatibility. Buffered fiber OFCC tight structure OFCC non-tight structure (250/900 μm) 2/ (2 mm) 2/ (2 mm) 2/ A (max) 32 mm 55 mm 55 mm See table VI. See A-A-59940 for additional information. FIGURE 2. LC APC ferrule/angle orientation. 4

TABLE X. Performance requirements. Requirement MM UPC SM UPC SM APC Initial insertion loss (db) 0.50 0.50 0.50 Insertion loss verification (db) 0.75 0.75 0.75 Return loss (db) 3/ 30/40/45 58 Color (part of housing or boot) Beige Blue or yellow Green Endface geometry OTES: 2/ 3/ 2/ 2/ Telcordia GR-326-CORE 30 db applies to epoxy polish and standard polish connectors, 40 db applies to epoxy polish enhanced polish connectors, and 45 db applies to quick-connect connectors. Applicable. ot applicable. Crimp tool compatibility. The LC 2-millimeter cordage connector configuration meets all requirements when the crimp sleeve is assembled to the jumper connector using a circular indent ring crimp die with a 2.67±0.08-millimeter (0.05±0.003-inch) minor diameter and a 3.43±0.08-millimeter (0.35±0.003-inch) major diameter or using a hex crimp die with flats measuring 2.947+0.025 millimeters (0.6+0.00 inch) across and.25 millimeter (0.049 inch) maximum length. Fusion splicer compatibility. The LC connector configuration capable of being fusion spliced (see table VII) shall be capable of assembly using fusion splicers approved to A-A-59799, Configuration 2. Mechanical splice tool compatibility. The LC connector configuration capable of being mechanically spliced (see table VII) shall permit fiber preparation and assembly of the splice utilizing tools and supplies available in the standard avy shipboard fiber optic toolkit, as described in 68728, 687283, or 708585, supplemented with parts and tools provided with the mechanical splice kit. Conformance inspection. Test performed, test procedure, connector performance, and test sample (specimen) quantity shall be in accordance with table XI with any exception (such as a modification or addition) listed in this specification sheet. A duplex version of a particular connector PI shall be recognized as conforming so long as the simplex version has shown to be conforming and the only change from the conforming simplex connector to the duplex connector is that the housing is duplex. 5

TABLE XI. Conformance inspection. Group I II III Inspection Visual and mechanical inspection A-A-59940 requirement and test paragraph Interchangeability and intermateability 3.. Interface dimensions 3..2 Cable strain relief, bend limiter 3..3, 3..4 Optical fiber compatibility 3..5 Optical fiber attachment (ferrule, quick-connect) 3..6 Color 3..7 Endface geometry (quick-connect) 3..8 Endface condition (quick-connect) 3..9 Cleaved fiber stub endface condition (quick-connect) 3..0 Ferrule extension and contact force 3.. Maintainability (cleaning, field termination, dust cover) 3.6., 3.6.2, 3.6.3 Size, mass, workmanship, marking 3.7, 3.8, 3.9, 3.0 Performance Insertion loss, initial 3.5. Ambient light susceptibility 3.5.2 Return loss 3.5.3 Mechanical properties Specimen 2/ on cable Type A on cable Type B or C -4-8 -6 /A -8-6 Cable pull-out 3.3. -8 /A Fiber pull-out 3.3.2 /A Fiber-to-ferrule pull-out 3.3.2. -4 /A Fiber-to-splice pull-out 3.3.2. 6-8 /A Flex 3.3.3 Twist 3.3.4 Force to engage/disengage 3.3.5 Impact 3.3.6 90-degree cable pull-out 3.3.7 Strength of coupling mechanism 3.3.8 Mating durability 3.3.9 Shock-COTS 3.3.0 Vibration 3.3. /A /A -8 6

Group IV V OTE: 2/ Inspection Environmental properties A-A-59940 requirement and test paragraph 3.4. humidity cycling 3.4.2 cycling 3.4.3 Life aging (temperature life) 3.4.4 Thermal shock 3.4.5 Materials on-metallic materials (adhesives, index matching gel, sealing compounds) 3.2. Metallic materials (dissimilar metals) 3.2.2 Toxic and hazardous products and formulations 3.2.3 Fungus 3.2.4 Oxygen index 3.2.5 Salt spray 3.2.6 Flammability 3.2.7 Radioactive materials 3.2.8 Lubricants 3.2.9 Sealing compounds 3.2.0 Liquid materials 3.2. Ferrule 3.2.2 Specimen 2/ on cable Type A on cable Type B or C /A /A 9-6 Applicable connector material samples may be provided in lieu of connector samples as test requirement and method require. Material certification may be provided as proof of conformance. Specimen shall be simplex connectors. /A /A Intended use. LC connectors in accordance with this specification sheet are intended to be used in a sheltered environment with commercial fiber optic cable, fiber optic cable in accordance with MIL-PRF-85045, and blown optical fiber tube furcation units in accordance with A-A-59729. 7

MILITARY ITERESTS Custodians: Preparing Activity: Army CR avy SH avy SH (Project 6060-203-007) Air Force Review Activities: Air Force 3, 9, 93, 99 Misc DI OTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.dla.mil. 8