INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

Similar documents
D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D

INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D5030S, D5030D D5030S - D5030D.

INSTRUCTION & SAFETY MANUAL

D1080D INSTRUCTION MANUAL. D Flammable Liquid Presence Detector Interface Relay Output. DIN-Rail Model D1080D

INSTRUCTION MANUAL. Switch/Proximity Detector Repeater Relay Output DIN-Rail Models D1030S, D1030D D1030S - D1030D

INSTRUCTION MANUAL. SIL 2 Switch / Proximity Detector Repeater, Open Collector Output DIN-Rail and Termination Board, Model D5231E

INSTRUCTION & SAFETY MANUAL

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-24VDC

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

INSTRUCTION & SAFETY MANUAL

BMX DDM Mixed Relay Input/Output module

PHOENIX CONTACT - 12/2007

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

MACX MCR-EX-SL-NAM-2RO(-SP)

XPSMCMDO Digital output pairs expansion modules with screw term

XPSMCMDI Input expansion module with screw term

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

Datasheet SRB301ST 24V (V.2)

MACX MCR-EX-SL-NAM-R(-SP)

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

INSTRUCTION & SAFETY MANUAL

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

APPLICATION GUIDE. Interface Modules IM Series.

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Datasheet - SRB 402EM-24V

Operating instructions. Speed monitor D / / 2014

Datasheet - SRB 301LC/B-24V

XPSMCMMX inputs 2 output pairs expansion module with screw term

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

SPST-NO SPDT DPST-NO DPDT

Room Temperature Controller

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Datasheet - SLB 200-C04-1R

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions Evaluation system for flow sensors VS / / 2013

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

RM35TF V AC

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Contact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position)

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Inductive proximity switches with long operating distance, series 500

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

SIL 2/3 Relays for all applications, with or without Line & Load Diagnostics. Product presentation

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

Compact Coded Magnetic Safety Interlock Switch and Control Units

Conductive Level Controller

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

ETD-BL-1T-OFF-CC- 10S

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

MINI-PS AC/10-15DC/8

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

LXM32AD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

CPCI-PS24 24V-Power Supply

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

2. Actuator B: Ball type P: Pin type F: Flat type

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Priva Blue ID Digital input module DI4/DI8/DI16

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

Switched Mode Power Supply Operating manual PAP800

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Transcription:

D603S D603D INSTRUCTI MANUAL SIL 3 Switch/Proximity Detector Repeater Relay, Termination Board Models D603S, D603D D603 SIL 3 Switch/Proximity Detector Repeater Relay G.M. International ISM0400

General Description: The single and dual channel Switch/Proximity Detector Repeater, D603S and D603D module is a unit suitable for applications requiring SIL 3 level (according to IEC 60:00 Ed. ) in safety related systems for high risk industries. The unit can be configured for switch or proximity detector (EN6046, NAMUR), or NC and for or SPST relay output contact. Each channel enables a load to be controlled by a switch, or a proximity detector. Fault detection circuit (DIP switch configurable) is available for both proximity sensor and switch equipped with end of line resistors. In case of fault, when enabled it deenergizes the corresponding output relay and turns the fault LED on; when disabled the corresponding output relay repeats the input line open or closed status as configured. D603D is programmable via dip switches as single input and two independent outputs. Out can be programmed for output duplicating Out or Fault detection Out. In case of duplication, relay actuation can be independently configured for each output. In case of fault output, relay actuation can be programmed as normally energized or normally deenergized. Mounting on customized Termination Boards. Characteristics Functional Safety Management Certification: G.M. International is certified by TÜV to conform to IEC60:00 part clauses 6 for safety related systems up to and included SIL3. FSM SIL 3 Technical Data Supply: 4 Vdc nom ( to 30 Vdc) reverse polarity protected, ripple within voltage limits Vpp, A time lag fuse internally protected. Current consumption @ 4 V: 3 ma for channels D603D, ma for channel D603S with short circuit input and relay energized, typical. Power dissipation: 0. W for channels D603D, 0.4 W for channel D603S with 4 V supply voltage, short circuit input and relay energized, typical. Isolation (Test Voltage): In/Out. KV; In/Supply. KV; In/In 00 V; Out/Supply 00 V; Out/Out 00 V. switching current levels:. ma (. to 6. ma range),. ma (0.4 to.3 ma range), switch current.6 ma ± 0. ma hysteresis. Fault current levels: open fault 0. ma, short fault 6. ma (when enabled both faults deenergize channel relay with single channel unit D603S or deenergize channel relay with D603D used as dual channel unit or actuate the fault relay out with D603D used as fault signaling unit). equivalent source: V KΩ typical ( V no load, ma short circuit). : SPST relay contact. material: Ag Alloy (Cd free), gold plated. rating: 4 A 0 Vac 000 VA, 4 A 0 Vdc 0 W (resistive load). Min.switching current ma. Mechanical / Electrical life: * 0 6 / * 0 6 operation, typical. Operate / Release time: / 4 ms typical. Bounce time / NC contact: 3 / ms typical. Frequency response: 0 Hz maximum. Compatibility: CE mark compliant, conforms to Directive: 04/30/EU EMC, 04/3/EU LVD, 0/6/EU RoHS. Environmental conditions: Operating: temperature limits 40 to 0 C, relative humidity %, up to C. Storage: temperature limits 4 to 0 C. Approvals: TÜV Certificate No. CIS346400, SIL / SIL 3 conforms to IEC60:00 Ed.. TÜV Certificate No. CIS360, SIL 3 Functional Safety Certificate conforms to IEC60:00 Ed., for Management of Functional Safety. Mounting: on customized Termination Board. Weight: about g D603D, g D603S. Connection: by polarized plugin disconnect screw terminal blocks to accommodate terminations up to. mm. Protection class: IP 0. Dimensions: Width. mm, Depth 3 mm, Height 0 mm. D603 SIL 3 Switch/Proximity Detector Repeater Relay G.M. International ISM0400

Model: Ordering Information D603 channel S channels D Front Panel and Features SIL 3 according to IEC 60:00 Ed. for Tproof / 0 years ( 0% / >0 % of total SIF), considering 00 ma max contact current. SIL according to IEC 60:00 Ed. for Tproof 0 years ( 0% of total SIF), considering 00 ma max contact current. PFDavg ( year) 4. E0, SFF 0.06 %, with independent channel configuration. PFDavg ( year) 4.6 E0, SFF 3.6 %, with D603D used as duplicator (both channels) or as fault indicator (only st ch.). PFDavg ( year) 4.66 E0, SFF 3.3 %, with D603D used as fault indicator (only nd ch.). Systematic capability SIL 3 fully independent channels. /NC switch/proximity Detector, / relay actuation mode. Field open and short circuit detection. Three port isolation, //Supply. EMC Compatibility to EN60006, EN600064, EN636, EN6363 for safety system. Infield programmability by DIP Switch. TÜV Certification. TÜV Functional Safety Certification. High Density, two channels per unit. Simplified installation using customized Termination Boards. Terminal block connections Ch for Proximity or Voltage free Ch for Proximity or Voltage free 0 0 Ch for Proximity or Voltage free Ch for Proximity or Voltage free G.M. International ISM0400 D603 SIL 3 Switch/Proximity Detector Repeater Relay 3

Function Diagram MODEL D603D D03D R R Proximity Supply 4 Vdc Out (SIL3) In R R Proximity 0 Out (SIL 3) In F Resistors R R used with contact required for line fault detection. Termination board connector Relay contacts shown in deenergized position Terminals 0 must be shorted to set module as Duplicator or Fault Out MODEL D03D D603D Duplicator or or Fault Out R R Proximity Supply 4 Vdc Out (SIL3) In 0 Out Duplicator or Fault (SIL 3) F Resistors R R used with contact required for line fault detection. Internal Dip switches programmable MODEL D603S D03S Termination board connector Relay contacts shown in deenergized position R R Proximity Supply 4 Vdc Out (SIL 3) In F Resistors R R used with contact required for line fault detection. Termination board connector Relay contact shown in deenergized position 4 D603 SIL 3 Switch/Proximity Detector Repeater Relay G.M. International ISM0400

Warning D603 series must be installed, operated and maintained only by qualified personnel, in accordance to the relevant national/international installation standards. Failure to properly installation or use of the equipment may risk to damage the unit or severe personal injury. The unit cannot be repaired by the end user and must be returned to the manufacturer or his authorized representative. Any unauthorized modification must be avoided. D603 module is a unit suitable for applications requiring SIL 3 level (according to IEC 60) in safety related systems for high risk industries. The unit can be configured for switch or proximity detector (EN6046, NAMUR), or NC and for or SPST relay output contact. Each channel enables a load to be controlled by a switch, or a proximity detector. Fault detection circuit (DIP switch configurable) is available for both proximity sensor and switch equipped with end of line resistors. In case of fault, when enabled it deenergizes the corresponding output relay and turns the fault LED on; when disabled the corresponding output relay repeats the input line open or closed status as configured. D603D is programmable via dip switches as single input and two independent outputs. Out can be programmed for output duplicating Out or Fault detection Out. In case of duplication, relay actuation can be independently configured for each output. In case of fault output, relay actuation can be programmed as normally energized or normally deenergized. Presence of supply power and status of output (energized or deenergized), as well as integrity or fault condition of sensor and connecting line are displayed by signaling LEDs (green for power, yellow for status and red for fault condition). Note: use of electrical contacts with fault detection enabled (control equipment) requires, near the switch at the end of the line a R KΩ typical (40 Ω to KΩ range) resistor in series and a R0 kω typical ( KΩ to KΩ range) resistor in parallel to the contacts in order to allow the fault detection circuit to distinguish between a condition of contact close/open and a line open/short circuit fault. Installation D603 series are Switch/Proximity Detector Interface housed in a plastic enclosure suitable for installation on customized Termination Board. D603 unit can be mounted with any orientation over the entire ambient temperature range. Electrical connection of conductors up to. mm² are accommodated by polarized plugin removable screw terminal blocks which can be plugged in/out into a powered unit without suffering or causing any damage. The wiring cables have to be proportionate in base to the current and the length of the cable. On the section Function Diagram and enclosure side a block diagram identifies all connections. Identify the number of channels of the specific card (e.g. D603S is a single channel model and D603D is a dual channel model), the function and location of each connection terminal using the wiring diagram on the corresponding section, as an example: For Model D603S, in case of Proximity or Voltage free, connect the wires at terminal for positive and for negative. For Model D603D in addition to channel connections above, connect terminal for positive and 0 for negative on channel. Connection for power supply and output are provided by Termination Board connector. Connect SPST relay contacts checking the load rating to be within the contact maximum rating (00 ma 0 Vac VA, 00 ma 0 Vdc W (resistive load)). Units must be protected against dirt, dust, extreme mechanical (e.g. vibration, impact and shock) and thermal stress, and casual contacts. If enclosure needs to be cleaned use only a cloth lightly moistened by a mixture of detergent in water. Any penetration of cleaning liquid must be avoided to prevent damage to the unit. Any unauthorized card modification must be avoided. According to EN600, D603 series must be connected to SELV or SELVE supplies. Startup Before powering the unit check that all wires are properly connected, particularly supply conductors and their polarity, input and output wires. Check conductors for exposed wires that could touch each other causing dangerous unwanted shorts. Turn on power, the power on green led must be lit, status and fault led on each channel must be in accordance with condition of the corresponding input line. If possible close and open input lines one at time checking the corresponding status and fault LEDs condition as well as output to be correct. G.M. International ISM0400 D603 SIL 3 Switch/Proximity Detector Repeater Relay

D603D used as double channel A configuration DIP switch is located on component side of pcb. This switch allows the configuration of input/output relationship, fault detection functions and operating mode. WARNING: dipswitch 6 must be set to position. Configuration Dip switch factory settings. All Switches are 3 4 6 Dip switch configuration CH 3 4 6 CH Must be set to "" position CH Setting Line fault detection (switch / proximity sensor) Position in fault condition Enabled (proximity sensor or switch with end of line resistors, IN / OUT or NC NC or NC NC CH Setting Line fault detection (switch / proximity sensor) 3 Position in fault condition Enabled (proximity sensor or switch with end of line resistors, 3 IN / OUT or NC NC 4 0 0 or NC NC 4 0 0 6 D603 SIL 3 Switch/Proximity Detector Repeater Relay G.M. International ISM0400

Configuration D603D used as duplicator or fault output A configuration DIP switch is located on component side of pcb. This switch allows the configuration of input/output relationship, fault detection functions and operating mode. WARNING: Terminals 0 must be shorted to set module as Duplicator or Fault Out. Dipswitch 3 must be set to position. Dip switch factory settings. All Switches are 3 4 6 Dip switch configuration 3 4 6 CH Setting Line fault detection (switch / proximity sensor) Must be set to "" position, Deenergized in fault condition Position in fault condition Enabled (proximity sensor or switch with end of line resistors,, not specified fault condition IN / OUT or NC NC or NC NC Duplicator Position in fault condition 6 Deenergized in fault condition if line fault detection enabled (SW ) Parallel Mode Set SW4 equal to SW 6 Not specified fault condition Reverse Mode Set SW4 opposite to SW Fault 6 Mode No Fault Fault condition 4 Mode No Fault Fault condition 4 G.M. International ISM0400 D603 SIL 3 Switch/Proximity Detector Repeater Relay

D603S A configuration DIP switch is located on component side of pcb. This switch allows the configuration of input/output relationship, fault detection functions and operating mode. WARNING: Dipswitch must be set to position. Configuration Dip switch factory settings. All Switches are 3 4 6 Dip switch configuration 3 4 6 must be set to "" position 346 Not used CH Setting Line fault detection (switch / proximity sensor) Position in fault condition Enabled (proximity sensor or switch with end of line resistors, IN / OUT or NC NC or NC NC D603 SIL 3 Switch/Proximity Detector Repeater Relay G.M. International ISM0400

Configuration DIP Switch factory settings (valid for D603S and D603D) SW SW SW3 SW4 SW SW6 SW SW D603D (used as double channel) Configuration Summary Table WARNING: dipswitch 6 must be set to position. Channel Line fault detection SW SW SW3 Channel IN/OUT SW SW4 (switch/proximity sensor) or NC Enabled, for SIL application (proximity sensor or switch with end of line resistors, detects field open circuit and short circuit, or NC D603D (used as duplicator or fault output) Configuration Summary Table WARNING: Terminals 0 must be shorted to set module as Duplicator or Fault Out. Dipswitch 3 must be set to position. Line fault detection SW SW IN/OUT SW (switch/proximity sensor) Enabled, for SIL application (proximity sensor or switch with end of line resistors, detects field open circuit and short circuit,, Deenergized in Fault condition, Not specified Fault condition or NC or NC SW6 SW SW Mode SW4 Duplicator Deenergized in fault condition if line fault detection enabled (SW ) Parallel (for SIL application) Set equal to SW Not specified Fault condition Reverse Set opposite to SW Fault (for SIL application) D603S Configuration Summary Table WARNING: Dipswitch must be set to position. Line fault detection SW SW IN/OUT SW (switch/proximity sensor) or NC Enabled, for SIL application (proximity sensor or switch with end of line resistors, detects field open circuit and short circuit, or NC G.M. International ISM0400 D603 SIL 3 Switch/Proximity Detector Repeater Relay