*Recommendations are subject to change. Consult your Lumenetix representative for the most updated list. Eco Loop 1. Eco Loop 2. Wallstation.

Similar documents
araya Dynamic Dimming LED Modules 12V DC Input (Constant Voltage) 1200 Maximum Peak Lumens Data Sheet

araya Dynamic Dimming LED Modules (DDM1C) 12V DC Input (Constant Voltage) 1000 Maximum Peak Lumens Data Sheet

Any manufacturer that makes a dimmer that sinks will work with Lumenetix modules since we source the voltage.

araya Color Tuning LED Modules 12V DC Input (Constant Voltage) 1200 Maximum Peak Lumens Data Sheet

araya Color Tuning LED Modules (CTM1C) 12V DC Input (Constant Voltage) 1000 Maximum Peak Lumens Data Sheet

araya Logic Module Tunable Color Linear LED Arrays (LTM2) 24V DC Input (Constant Voltage) 1000 Typical Peak Lumens / Foot Data Sheet

araya Logic Module Tunable Color Linear LED Arrays (LTM2) 1000 Typical Peak Lumens / Foot Data Sheet

araya Dynamic Dimming LED Modules (DDM1C) 24V DC Input (Constant Voltage) 1850 Maximum Peak Lumens Data Sheet

araya Logic Module Dynamic Dimming Round LED Arrays (DDM2) 24V DC Input (Constant Voltage) 5000 Maximum Peak Lumens Data Sheet

araya Logic Module Tunable Color Round LED Arrays (CTM2) 24V DC Input (Constant Voltage) 5000 Maximum Peak Lumens Data Sheet

QSE-CI-DMX Control Interface

LUT-DMX DMX512 Control Interface

QuantumR Light Management Hub

QSWA-KP5-DW- 5 Button Wallstation with Raise/Lower

Energi Savr Node with DALI for Quantum

EcoSystem to 0 10 V- Interface

QuantumR Light Management Hub (QP2)

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS

GRX-CI-NWK-E Control Interface

GRX-CI-RS232 Control Interface

Hi-lume A-Series Driver Overview EcoSystem or 3-wire control

EcoSystem Digital Ballasts

Tunable White with Smart White Technology LEDENGIN PLATFORM. DIM10 (0-10V 1% Dimming Standard) Compatible with Elite, LED Engin. Lumenetix Platform

Power Supply Installation

UL Listed Hi-lume A-Series Constant Voltage Driver Overview

Hi-lume 1% EcoSystem Constant-Voltage 24 V- LED Driver with Soft-on, Fade-to-Black Dimming Technology

Light Management Hub. Quantum 230 V CE Light Management Hub. Centralized Control Equipment

QSNE-2DAL-D Energi Savr Node QSTM 20 V. DALI Loop 2. seetouch QS Wallstation Energi Savr Node QS. QS Control Link

Hi-lume Premier 0.1% EcoSystem LED Driver

Installation Instructions MX LED Wall Wash Remodel

QSE-CI-DMX Control Interface

MODA COVE INTERIOR DYNAMIC WARM PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

COOLEDGE TILE TUNABLE WHITE - SPECIFICATIONS SYSTEM OVERVIEW SPECIFICATION GENERAL FEATURES. DATE NOTE For Luminous Surfaces

MODA COVE INTERIOR RGB PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS

CS XL XM. EcoSystem Bus Supply

OMX-CI-RS232 Control Interface

QSWE-2BN- - QSWE-2BI- - 2-Button Wallstation

Energi Savr NodeTM QSN-2ECO-PS120 EcoSystem with Shades ESN a

Quantum Light Management Hub (QP3) for Quantum Select

MODA COVE INTERIOR DYNAMIC WHITE PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

DIRECT POWER LIGHTING MANUAL

OMX-CI-NWK-E Control Interface

COOLEDGE LINE - SPECIFICATIONS SYSTEM OVERVIEW GENERAL SPECIFICATION FEATURES. DATE NOTE For Luminous Surfaces

MODA COVE EXTERIOR DYNAMIC WARM

Power Supply and Fan Module Installation

Energi Savr NodeTM Programming Interface

DMX, 2 CHANNEL 2 Channel DMX Driver

EMC Installation Guide

EGRX-2B-SL- - 2-Button Wallstation

GRX-CI-NWK-E Control Interface

ETC Installation Guide

VersaLamp High Bay/Light Fixture Installation Instructions

MODA MINI COVE INTERIOR RGB SPECIFICATION. Project Name: Client: MODA Contact: Quantity: PO#: Type: Notes:

COOLEDGE LINE - SPECIFICATIONS SYSTEM OVERVIEW GENERAL SPECIFICATION FEATURES. DATE NOTE For Luminous Surfaces

Compact, Low Profile High Rendering, 100% Diffusion

MODA MINI COVE INTERIOR RGBW SPECIFICATION. Project Name: Client: MODA Contact: Quantity: PO#: Type: Notes:

TRULINE 1A ORDERING CODES

3% VOLTAGE DROP. Installation Instructions for 100 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS!

LQSE-4S8-120-D. 120 V~ 50 / 60 Hz 16 A. lutron.com LQSE-4S8-120-D. Dimming Power Module. Option. Input. Opt Def H M

EcoSystem One-Line. EcoSystem C5-XPJ-16A Switching Power Module

STEVE S LEDS. Aquarium Controller Interface (ACI)

Max. Input Power (W) Input Current. Inrush Current

SINGLE COLOR TRULUX STANDARD TRULUX HIGH OUTPUT TRULUX SPEC GRADE. Description / Performance. Description / Performance. Description / Performance

4 Connection and interface

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions

GRAFIK Eye 3000 Series Control Unit

Precision DMX Manual

Micro Motion. Series 3000

Two Circuit Track Power System IS24 / IS26 / IS28

MODA COVE INTERIOR RGBW PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

SS-1BI-GWH-E00 1-Button Wallstation

MODA COVE EXTERIOR RGBW PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

GRX-3000 Control Units

SAVE THESE INSTRUCTIONS

Light Distribution. LED Chip. Dimming. Mounting. Reel Lengths. Certifications. Operating Temp. Environment. Ordering Information

7011-C, 7012-C, 7013-C, 7015-C, 7018-C, 7021, MTC-2 Mass Terminated Assembly Twisted pair (45) 96-pin female 96-pin female 2 6.

ELEMENT offers five LED options that allow specifiers to choose the LED source they value most based on output, quality of light, color and more.

Linearray PD Retrofit Kit

Power & Communication Cables

HomeWorks QS Processor

Application Note #658 Revision B January 2018 Programming Residential Systems with Lutron LED Drivers

QSE-CI-NWK-E Control Interface

Specification Sheet lumencove 2.0

ME 3210: Mechatronics Signal Conditioning Circuit for IR Sensors March 27, 2003

Appendix D. EMC Installation Guidelines. Safety Considerations. Ferrite Absorbers and P-Clips. General Product Philosophy

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

PROJECT INFORMATION FLANGE FINISH LENS S. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

Dim levels for each system output may be controlled by either of the following methods:

Energi Savr Node for DALI QSNE-2DAL-D DALI Fixture Controller V. Photo

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

Avista LED Light Engine

Yes Additional interface boards may be required.

Installation Manual. Balboa Bluetooth Audio bba 2

232iLM Keypad Installation and Programming Instructions

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

Installation instructions DC Protection and Delay unit, Version 1.2 The package should contain: A piece of normal gauge yellow wire for the AC connect

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

232iLM Keypad Installation & Programming Instructions

10-Output Configurable Smart Panel

Transcription:

ECOSYSTEM PROTOCOL 1.1 Lutron EcoSystem Protocol EcoSystem technology is a control method for LEDs that provides addressing of individual fixtures and status feedback. This makes it easy to digitally assign one or many fixtures without complicated wiring. This opens up an entire suite of energy-saving, system-monitoring and system-control schemes where the design, setup and rezoning are all done within software, making the electrical and control design simple. The araya modules attached to different interface boards can be controlled independently or assigned to a single group by the EcoSystem controller. The EcoSystem control is responsible for saving any configuration settings. Once an interface board is assigned a pair of addresses, assigned addresses are saved in NVRAM. During the EcoSystem discovery process, the user pairs the desired dimming control in the controller to the Dim channel address in the interface board. The same applies for the CCT channel. 1 pair 16AWG Eco Loop, 900 feet (field wiring). Maximum of 64 addresses on each loop. EcoSystem Control Systems (recommended list)* Quantum System HomeWorks QS Grafik Eye QS Control Unit with EcoSystem EnergiSavr Node with EcoSystem Power Module with EcoSystem *Recommendations are subject to change. Consult your Lumenetix representative for the most updated list. Example Lutron EcoSystem Example Power Eco Loop 1 Eco Loop 2 QS Link Fixture* Up to 64 devices on each loop for Eco-1, and up to 32 devices on each loop for Eco-2 HomeWorksR QS Power GRAFIK Module with Module Processor 120 / 230 V~ EyeR QS Control Power Up to 100 EcoSystem HomeWorksR QS Wallstation SivoiaR QS Shade / Drapery Fixture* Fixture* Fixture* QS Contact Closure Interface total QS devices *Fixture refers to a luminaire with one Lumenetix module, and with one address (DDM) or two addresses (CTM). QS Power Supply 1 Lutron EcoSystem Protocol & Wiring Specifications

ECOSYSTEM PROTOCOL 1.2 Lutron EcoSystem Field Wiring EcoSystem Digital Loop can be wired as Mains voltage or IEC PELV/NECR Class 2 for maximum wiring flexibility.. The Loop is polarity insensitive and can be wired in any topology.. Consult all national and local electrical codes for separation requirements.. Wire Gauge Maximum EcoSystem-Compliant Loop Wire Length 4.0 mm 2 (12 AWG) 671 m (2200 ft) 2. mm 2 (14 AWG) 427 m (1400 ft) 1. mm 2 (16 AWG) 27 m (900 ft) 1.0 mm 2 (18 AWG) 17 m (70 ft) Drain Wire Connections Drain wire connections are required as follows. Shielding To add another level of protection from electromagnetic noise, a grounded shield is added over the twisted pair wires. When this is enclosed in a protective jacket, to avoid ground loops and electromagnetic contamination of the ground system, all control ground wiring, including cable shields and drain wires, should be treated like sensitive current-carrying conductors. All control ground wires should be insulated (not bare) and the same wiring practices should be observed with ground wires as with other sensitive signals. Care must also be taken when designing control wiring to ensure that each shield is connected to only a single ground point. You should establish this point at a central location, like a control panel or cabinet, and avoid all connection to grounds in the field. A control ground is sometimes referred to as an isolated ground (an oxymoron) for this reason, but the term single-point ground is more accurate. Method-1 A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. This is usually done at the field end of the cable where no shield grounding is desired. You will then use insulating tape or heat-shrink tubing to protect the cable from contamination and to prevent accidental grounding of the shield or drain wire. An accidental ground at this point would almost certainly create an undesirable ground loop. Method-2 A typical two-pair shielded cable can be prepared for termination to the terminals with the drain wire cut off. The drain wire, which is an uninsulated conductor, is sleeved with a insulating tubing to prevent accidental grounding. The crimp-on lug is valuable in this instance to retain the tubing. Insulating tape or heat-shrink tubing is again used to protect the cable from contamination and to prevent accidental grounding, since any accidental connection between the drain wire and a chassis, frame, or enclosure would almost certainly create a ground loop. 2 Lutron EcoSystem Protocol & Wiring Specifications

2.1a Lutron EcoSystem Accessory Card Wiring Diagram araya Logic Module (ALM) with Linear Arrays 1. 24V power (red/black) is Class-2 rated. 2. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control. 3. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 160-8000K. 4. The araya Tunable Color 2.0 ios App should be turned on, and the DMX channels should be set to 2, 4, 6, 8. TUNABLE COLOR LINEAR LED ARRAY RIBBON CONNECTOR CABLE Lutron EcoSystem wire tail (labeled and ) to junction box. LUTRON ECOSYSTEM CONTROLLER WHITE / VIOLET STRIPES VIOLET BLACK (Common) RED (+) CLASS-2 AC TO DC 24V POWER SUPPLY (SUPPLIED BY OEM) WHITE (NEUTRAL) BLACK (HOT) ALM WITH LUTRON ACCESSORY BOARD ALM 24V POWER CABLE (28.030.001.01) LINE-IN VOLTAGE (REFER TO POWER SUPPLY) EcoSystem accessory board connects to an electrically isolated expansion port within the ALM The Constant /Live must not be wired to a switching device. This may be put on a relay for maintenance. 3 Lutron EcoSystem Protocol & Wiring Specifications

2.1b Lutron EcoSystem Accessory Card Wiring Diagram araya Logic Module (ALM) with Round Arrays 1. 24V power (red/black) is Class-2 rated. 2. EcoSystem Channel 1 is always Intensity control. EcoSystem Channel 2 is always CCT control. 3. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 160-8000K. 4. The araya Tunable Color 2.0 ios App should be turned on, and the DMX channels should be set to 2, 4, 6, 8. TUNABLE COLOR ROUND LED ARRAY RIBBON CONNECTOR CABLE MAKE SURE TO ALIGN INDEX TAB TO INDEX SLOT. Lutron EcoSystem wire tail (labeled and ) to junction box. LUTRON ECOSYSTEM CONTROLLER WHITE / VIOLET STRIPES VIOLET BLACK (Common) RED (+) CLASS-2 AC TO DC 24V POWER SUPPLY (SUPPLIED BY OEM) WHITE (NEUTRAL) BLACK (HOT) ALM WITH LUTRON ACCESSORY BOARD ALM 24V POWER CABLE (28.030.001.01) LINE-IN VOLTAGE (REFER TO POWER SUPPLY) EcoSystem accessory board connects to an electrically isolated expansion port within the ALM The Constant /Live must not be wired to a switching device. This may be put on a relay for maintenance. 4 Lutron EcoSystem Protocol & Wiring Specifications

2.2a Lutron EcoSystem Input; (DCA) DDM1C (one channel) / CTM1C (two channel) 24V 1. 24V power (red/black) is Class-2 rated. 3. Adapter is configured at The araya Tunable Color 2.0 ios App should be turned on, and the DMX channels should be set to 2, 4, 6, 8.. One EcoSystem address (1 channel for warm-dim) per DDM module/dca kit. 8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 160-8000K. the unit. 10. DMX Output used with this system. Lutron EcoSystem wire tail (labeled and ) to junction box. /Blue and Gray/ 0-10V wires can be tied together or left open. Minimum requirement is a DMX type wire. is Data Negative. with Stripe is Data Positive. E: This wire may be shipped in GREEN color in CTM1 DDM1 24V DC, Class 2 The Constant /Live must not be Lutron EcoSystem Protocol & Wiring Specifications

2.2b Lutron EcoSystem Input; (DCA) DDM1C (one channel) / CTM1C (two channel) 12V 1. 12V power (red/black) is Class-2 rated. 3. Adapter is configured at The araya Tunable Color 2.0 ios App should be turned on, and the DMX channels should be set to 2, 4, 6, 8.. One EcoSystem address (1 channel for warm-dim) per DDM module/dca kit. 8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 160-8000K. the unit. 10. DMX Output used with this system. Lutron EcoSystem wire tail (labeled and ) to junction box. /Blue and Gray/ 0-10V wires can be tied together or left open. Minimum requirement is a DMX type wire. is Data Negative. with Stripe is Data Positive. E: This wire may be shipped in GREEN color in CTM1 DDM1 12V DC, Class 2 The Constant /Live must not be 6 Lutron EcoSystem Protocol & Wiring Specifications

2.3 Lutron EcoSystem Input; (DCA) DDM1B (one channel) / CTM1B (two channel) 12V 1. 12V power (red/black) is Class-2 rated. 3. Adapter is configured at The araya Tunable Color 2.0 ios App should be turned on, and the DMX channels should be set to 2, 4, 6, 8.. One EcoSystem address (1 channel for warm-dim) per DDM module/dca kit. 8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 160-4000K. the unit. 10. DMX Output used with this system. Lutron EcoSystem wire tail (labeled and ) to junction box. /Blue and Gray/ 0-10V wires are tied together is Data Negative. with Stripe is Data Positive. E: This wire may be shipped in GREEN color in CTM1 DDM1 12V DC, Class 2 The Constant /Live must not be 7 Lutron EcoSystem Protocol & Wiring Specifications

2.4 Lutron EcoSystem Input; (DCA) DDM1 (one channel) / CTM1 (two channel) 12V 1. 12V power (red/black) is Class-2 rated. 3. Adapter is configured at. One EcoSystem address (1 channel for warm-dim) per DDM module/dca kit. 8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 160-4000K. the unit. 10. LX Output used with this system. Lutron EcoSystem wire tail (labeled and ) to junction box. CTM1 DDM1 /Blue and Gray/ 0-10V wires are tied together 12V DC, Class 2 is Data Negative. with Stripe is Data Positive. E: This wire may be shipped in GREEN color in DISCONTINUED - NO LONGER AVAILABLE The Constant /Live must not be 8 Lutron EcoSystem Protocol & Wiring Specifications

2. Lutron EcoSystem Input; (DCA) DDM0 (one channel) / CTM0 (two channel) 24V 1. 24V power (red/black) is Class-2 rated. 3. Adapter is configured at. One EcoSystem address (1 channel for warm-dim) per DDM module/dca kit. 8. In the EcoSystem programming mode, EcoSystem Channel 1 controls the intensity from 100%-1%. EcoSystem Channel 2 controls the CCT range from 160-4000K and 2700-6000K. the unit. 10. LX Output used with this system. CTM0 DDM0 /Blue and Gray/ 0-10V wires are tied together Lutron EcoSystem wire tail (labeled and ) to junction box. 24V DC, Class 2 is Data Negative. with Stripe is Data Positive. E: This wire may be shipped in GREEN color in DISCONTINUED - NO LONGER AVAILABLE The Constant /Live must not be 9 Lutron EcoSystem Protocol & Wiring Specifications