EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

Similar documents
New Products Electric actuator ERL2/ESD2 Series

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

4 Axis Step Motor Controller

3-position, AC100/200V controller for RCP2/RCP3 Series. 3 position, AC100V controller for RCA/RCA2/RCL Series. Controller. Power supply.

PIO type (PNP Specification) Controller that moves by designating position numbers with PNP PIO via PLC. 16 points

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Power supply unit PLC. Gateway unit. 4 axes

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Multi-Axis Step Motor Controller

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

XW3B. Connector Terminal Boxes. Ratings and Specifications. Compatible Connectors. Materials and Finish

Programless Controller (With Stroke Study) How to Order

Classification Enclosure rating Input voltage Type of

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

One step ahead in performance and mounting ease

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

Thread length (overall length) material

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Communications & Networking

Operating instructions. Switching amplifier DN0210 DN / / 2015

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

PI-EX-ME-2NAM/COC-24VDC

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

LASER. Laser Displacement Transducer. Series LAH-G1. Key-Features:

Model Number Structure

Safety Relay Unit (I/O Unit Type)

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

PI-EX-ME-2NAM/COC-120VAC

Safety Monitoring Relays

Solid State Remote Power Controller E

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Optimum sensing capability for LCD manufacturing

PHOENIX CONTACT - 05/2007

Communication & Networking

ETD-BL-1T-OFF-CC- 10S

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings

PHOENIX CONTACT - 12/2007

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

E2Q4 Square Proximity Sensor

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

LCD Readout Digital Pressure Switch

Electronic timer CT-ERD.12

120 WATT FLEX ATX TYPE WITH ACTIVE PFC

SiO Controller. SiO Controller. SiO-C Ver onwards SiO2/SiO2PNP Ver onwards SiO3 Ver onwards INSTRUCTION MANUAL. Version 3.

BGS (at min. setting) BGS (at max. setting)

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Tecnología en Electrónica y Control SRL Ficha Técnica

C5 Series Stainless Steel Photoelectric

ERC Quick Start Guide

5 Fieldbus Technology

MACX MCR-EX-SD LP(-SP)

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

Time Counters mini "h", DC Version

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

USER GUIDE ARDBOX ANALOG

Connecting cables for valves, plug pattern ZC, metric screw Type codes

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Original operating instructions Safety relay with relay outputs G1501S / / 2016

EtherCAT Remote I/O Terminal GX series

CJ series Ergonomic multifunction joysticks

Electronic timer CT-AHD.22

E3FS. Connect up to 4 sets of E3ZS/E3FS per B1 Module for F3SX Safety Controller

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

Solid State Remote Power Controller E /627

Screw terminal panels, Relay output boards, connection cables

Multi-Point Gas Detection and Control System

PSR DC/ESP4/2X1/1X2

Program controller for operating RCA2/RCA Series actuators. One unit can handle various controls. Up to 2 axes

Operating instructions. Speed monitor D / / 2014

J8 SWITCHES WITH TRIP FUNCTION UPGRADED TYPE

Non-Contact Safety System CES-AZ

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Product Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series

Mitsubishi Electric Air-conditioner Network System

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

F3S-B. Safety Design for Category 2. Suitable for Detecting Human Bodies in a Dangerous Area. Safety Light Curtain. Features

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

CJ series Ergonomic multifunction joysticks

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Transcription:

Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available How to order EC 07 B Symbol A Series A Series 07 7 point 63 63 point B Installation method B Installation method A EC07 Standard installation B EC07 DIN rail installation C EC63 Standard installation D EC63 DIN rail installation Series EC07 EC63 Applicable motor size 4, 56 Setting method With teaching pendant or PC software Control mode (Single position, double position, double 3-position) Simple mode (3 point) Standard mode (7 point) (Single position, double position, double 3-position) Simple mode (7 point) Standard mode (63 point) Body light Green: Motor energizing (de-energizing while flashing) / red: alarm Input no. 7 points (photo coupler insulation) 10 points (photo coupler insulation) No. of output points 7 points (photo coupler insulation) 1 points (photo coupler insulation) Motor power voltage 4 VDC ± 10% Motor part max. instantaneous current 4:.7A, 56: 4A Control power source voltage 4 VDC ± 10% Control section current consumption 300mA or less (includes ETP current consumption) Brake Power voltage 4 VDC ± 10% Power consumption Refer to the specifications for each actuator Insulation resistance 100 MΩ and over at 500 VDC Withstanding voltage 1000 VAC for one minute Ambient temperature 0 to 40ºC no freezing Ambient humidity 35 to 80% (with no dew condensation) Storage ambient temperature -10 to 50ºC no freezing Storage ambient humidity 35 to 80% (with no dew condensation) Atmosphere Free of corrosive and explosive gases and dust Degree of protection IEC standards IP30 equivalent Weight Approx. 150g (Standard installation) Approx. 180g (Standard installation) Approx. 180g (DIN rail installation) Approx. 10g (DIN rail installation) 11

Panel description EC Controller Panel description EC07 1 Indicator CN5 I/O connector 1 Indicator Green: Motor energizing (de-energizing while flashing) Red: alarm 3 CN4 SIO connector I/O connector Input/output the control signal by connecting external control devices (PLC, etc.). 4 5 CN3 Encoder connector CN Motor connector 3 SIO connector Connect the PC and the teaching pendant, set the parameters, and carry out manual operations. 6 CN1 Power connector 4 Encoder connector Connect relay cable and input the encoder signal. 5 Motor connector Connect relay cable and output power signal to motor. 6 Power connector Input DC control power and motor power to the controller. EC63 1 Indicator CN5 I/O connector 3 CN4 SIO connector 4 CN3 Encoder connector 5 CN Motor connector 6 CN1Power connector Power connector: CN1 *Power plug is enclosed. CN1 List of power connector terminals (manufactured by PHOENIX CONTACT DF 1.5/3-STF-3.5) Terminal name Function name Functional explanation BK Brake Release Apply 4 VDC to release brake. Motor power shutoff and is connected with jumper wire in standard. Motor power shutoff By shutting it off, motor power is shut off. Common power (+) Input 4 VDC common for motor power and control power. Common power ( ) Connect 0 VDC common for motor power, control power, releasing brake, emergency stop input. EMG Emergency Stop Input Connect the b-contact emergency stop switch, then input 4 VDC. CN1 power plug BK EMG 1

EC Controller Dimensions EC07 [A: Standard installation] 35 φ5. penetrating 66 31 4.7 1.5 Ground terminal (M3 5 Round head screw) 41 84.5 15.5 10 101 110.5 Note) For details on standard installation specifications for earth connection, please refer to the instruction manual. 5. [B: DIN rail installation] *It is possible to mount on DIN rail 76 13

EC07 I/O cable specification Type 0-core cabtyre cord (UL94V-0) Sheath material Polyvinyl chloride Sheath diameter φ8.4 Sheath color Gray Conductor 0.mm (AWG4) annealed copper wire Length of stripped lead wire (reference) Approximate 7 mm from lead wire end EC Controller Circuit example Host system side Power supply 4 VDC 3.0A (Motor 4) 4.3A (Motor 56) Emergency stop reset switch Emergency stop switch Manual brake Controller side CN1 Power connector release switch BK Release brake. Motor power shutoff Controller power supply + EMG Controller power supply - Emergency Stop Input Output side COM 4 VDC external power* I/O cable Blue Input common +/- PLC Output unit Output side Return to origin command signal Servo ON signal Alarm reset command signal Light green Grey Purple Green Yellow Orange Brown Universal input 1 Universal input Universal input 3 Universal input 4 Input 5 Input 6 Input 7 Input signal Input side COM PLC Input unit Input side 4 VDC external power* + - Return to origin completion signal Ready to operate completion signal Alarm signal (b contact connection) Blue(white line) Light green (white line) Grey (white line) Purple (white line) Green (white line) Yellow (white line) Orange (white line) Brown (white line) Output common +/- Universal output 1 Universal output Universal output 3 Universal output 4 output 5 output 6 output 7 Output signal Note: Check once more before turning the product on to prevent incorrect wiring. *1: Refer to table below for details on the Universal I/O. *: External power supply (4 VDC) is required for both input/output. Input/output COM is available for both + and. : To shut off the motor drive power supply externally due to the safety category issue, connect the contact like electromagnetic switch between and terminals. Lay out of general purpose I/O Control mode Standard mode 7 point Simple mode 3 points Double -position Double 3-position Single Universal input 1 Point moving start Point 1 moving start Solenoid valve moving command 1 Solenoid valve moving command 1 Universal input Point selection bit Point moving start Solenoid valve moving command Solenoid valve moving command Solenoid valve moving command Universal input 3 Point selection bit 1 Point 3 moving start Universal input 4 Point selection bit 0 Universal output 1 Point moving done Point 1 moving done Point 1 moving done Point 1 moving done Point 1 moving done Universal output Point confirmation bit Point moving done Point moving done Point moving done Point moving done Universal output 3 Point confirmation bit 1 Point 3 moving done Switch 1 output Switch 1 output Switch 1 output Universal output 4 Point confirmation bit 0 Switch output Switch output Switch output 14

EC Controller Dimensions EC63 [C: Standard installation] 35 φ5. penetrating 66 31 11 4.7 130.5 5. [D: DIN rail installation] *It is possible to mount on DIN rail 41 145.5 104.5 140 Note) For details on standard installation specifications for earth connection, please refer to the instruction manual. 1.5 Ground terminal (M3 5 Round head screw) 76 15

EC63 I/O cable specification Type 8-core cabtyre cord (UL94V-0) Sheath material Polyvinyl chloride Sheath diameter φ8.8 Sheath color Conductor Length of stripped lead wire (reference) EC Controller Gray 0.mm (AWG4) annealed copper wire Approximate 7 mm from lead wire end Circuit example Host system side Power supply 4 VDC 3.0A (Motor 4) 4.3A (Motor 56) Emergency stop reset switch Emergency stop switch Manual brake Controller side CN1 Power connector release switch BK Release brake. Motor power shutoff Controller power supply + Output side COM 4 VDC external power* EMG I/O cable Blue Controller power supply - Emergency Stop Input Input common +/- PLC Output unit PLC Input unit Output side Input side COM Input side Return to origin command signal Servo ON signal Alarm reset command signal 4 VDC external power* + - Zone 1 signal Zone signal Return to origin completion signal Ready to operate completion signal Alarm signal (b contact connection) Light green Grey Purple Green Red Black Light green (black line) Yellow Orange Brown Blue (white line) Light green (white line) Grey (white line) Purple (white line) Green (white line) Red (white line) Black (white line) Blue (black line) Green (black line) Orange (black line) Yellow (white line) Orange (white line) Brown (white line) Universal input 1 Universal input Universal input 3 Universal input 4 Universal input 5 Universal input 6 Universal input 7 Input 11 Input 1 Input 13 Output common +/- Input signal Universal output 1 Universal output Universal output 3 Universal output 4 Universal output 5 Output Universal output 6 signal Universal output 7 Output 9 Output 10 Output 11 Output 1 Output 13 Note: Check once more before turning the product on to prevent incorrect wiring. *1: Refer to table below for details on the Universal I/O. *: External power supply (4 VDC) is required for both input/output. Input/output COM is available for both + and. : To shut off the motor drive power supply externally due to the safety category issue, connect the contact like electromagnetic switch between and terminals. Lay out of general purpose I/O Control mode Standard mode 63 point Simple mode 7 point Double -position Double 3-position Single Universal input1 Point moving start Point 1 moving start Solenoid valve moving command 1 Solenoid valve moving command 1 Universal input Point selection bit 5 Point moving start Solenoid valve moving command Solenoid valve moving command Solenoid valve moving command Universal input3 Point selection bit 4 Point 3 moving start Universal input4 Point selection bit 3 Point 4 moving start Universal input5 Point selection bit Point 5 moving start Universal input6 Point selection bit 1 Point 6 moving start Universal input7 Point selection bit 0 Point 7 moving start Universal output1 Point moving done Point 1 moving done Point 1 moving done Point 1 moving done Point 1 moving done Universal output Point confirmation bit 5 Point moving done Point moving done Point moving done Point moving done Universal output3 Point confirmation bit 4 Point 3 moving done Switch 1 output Switch 1 output Switch 1 output Universal output4 Point confirmation bit 3 Point 4 moving done Switch output Switch output Switch output Universal output5 Point confirmation bit Point 5 moving done Universal output6 Point confirmation bit 1 Point 6 moving done Universal output7 Point confirmation bit 0 Point 7 moving done 16

EC Controller Power supply circuit Power specifications Power voltage 4 VDC ± 10% Max. instantaneous current* ERL-45/ESD-35, 45: 3.0A ERL-60/ESD-55: 4.3A *: Includes when teaching pendant is connected. Power supply circuit Connected with jumper wire by default + I/O circuit Input specification Input no. 7 point (EC07) 10 point (EC63) Input voltage 4 VDC ± 10% Input current 3mA/1 points Input current when turned ON ma (MIN) Input current when turned OFF 0.5mA (MAX) Input circuit Input COM The input is non-polar. (For input COM, either of + or can be used.) Output specifications No. of output points 7 point (EC07): 1 point (EC63) Load voltage 4 VDC ± 10% Load current 10 ma or less/1 point Internal voltage drop 6V or less (under 5ºC)*1 Leakage current 10μA Output short-circuit protection circuit Selected Connecting load PLC *1: At 40ºC, it is 6V or less with 9mA load current. Output circuit Output COM Output is non-polar. (COM is available for both + and.) 17