ORDERING INFORMATION SEE PAGE 6

Similar documents
Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

275 Watt Medical Ultra low profile

Safety Standards. Model Number: Unit Weight:

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Universal Power Supplies

Safety Standards. Model Number:

Safety Standards. Model Number:

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

60 Watt Medical (MWLT)

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

Safety Standards. Model Number:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Input Voltage Range AC Input. Input Frequency Range. Output Power natural convection. Operating Temperature Range. Model Selection

Safety Standards. Model Number:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

Safety Standards. Model Number:

CINT W Triple Output Industrial Series

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

EMH Series. 250 W & 350 W Forced-cooled. Industry Standard 3 x 5 x 1.43 Format. IT & Medical (BF) Approvals. 80 V VAC Operation

Safety Standards. Model Number:

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

Safety Standards. Model Number:

Safety Standards. Model Number:

Enclosed Power Supplies

Medical AC-DC Enclosed Power Supply 24V 200W 2 x4 High Density / MDS-200APB24 AA

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

VP ELECTRONIQUE MASSY - Tel

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

Max Output Power Voltage. Convection Forced Convection Forced Nom Peak (2) Model Number (1)

Output Voltage* (nom.)(adjustable)

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Safety Standards. Model Number:

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

MMA-15 series. 15W Medical Grade Ultraminiature Switching Power Supplies. Single / Dual / Triple Outputs. Universal 90 to 264VAC Input

12-15VDC (12V±5%) 24-28VDC (24V±5%)

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Cool. NFF Series. CoolX600 NFF Series. NFF Series; No Fan Featured

Safety Standards. Model Number

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90

General. Environmental. EMC & Safety

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

IEC/EN/UL60950 & CE certified, EN55032 Class B

Model Number Output Voltage Max. O/P Amps Min. O/P Amps 230VAC R&N P-P

MDS-300APB24 AA. Medical AC-DC Open Frame Power Supply 24V 300W with 5V/0.5A Standby / MDS-300APB24 AA MDS 300 A P B 24. Highlights & Features

Universal input VAC <150mW No load power consumption

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

500Watts Medical Single Output

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

030AAC Highlights & Features

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

SPECIFICATIONS: PSAK650

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

Output Voltage* (nom.)(adjustable)

CLP0224 SERIES 200 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.40

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

LED Indicator. Class I

PRODUCT SPECIFICATION File:SSA Model : SSA Rev:A2 Date: Nov. 29, 2010

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

C B. Models. Operating up to 5000m altitude 5 year product warranty

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

-48 VDC Input. ETSI Compliant. NEBS Compliant. Convection-cooled. Covered Versions Available

Transcription:

400W High Density Medical/Industrial Grade Open Frame Power Supplies Medical Safety Approval 60601-1 3rd Edition 2 MOPP Class 2 for home use medical applications (BSM400) Single output with 5V Auxiliary and 12V fan output 400 Watts in compact 3 x 5 x 1.4 footprint High Efficiency, up to 92% @ 230Vac High Power Density up to 19W/Inch3 Universal 90-264 VAC INPUT, 50/60 Hz 230W rating with natural convection ORDERING INFORMATION SEE PAGE 6 Model Output Voltage Output Current, A 5V Aux. A Forced/Natural Convection Forced/Natural Convection 12V Fan Output current, A Forced/Natural Convection Efficiency, typ. 230/115VAC A(B)SM400S- 12 12 VDC 33.3/19.17 2A/1A 1A/0.5A 90/86 A(B)SM400S- 15 15 VDC 26.67/15.34 2A/1A 1A/0.5A 90/86 A(B)SM400S- 20 20 VDC 20/12.5 2A/1A 1A/0.5A 91/88 A(B)SM400S- 24 24 VDC 16.7/10.4 2A/1A 1A/0.5A 91/88 A(B)SM400S- 28 28 VDC 14.3/9 2A/1A 1A/0.5A 91/88 A(B)SM400S- 36 36 VDC 11.11/7 2A/1A 1A/0.5A 91/88 A(B)SM400S- 48 48 VDC 8.33/5.2 2A/1A 1A/0.5A 91/88 A(B)SM400S- 54 54 VDC 7.4/4.6 2A/1A 1A/0.5A 91/88 PRODUCT DESCRIPTION The Astrodyne ASM and BSM 400 Series are miniature open frame power supplies designed for medical applications. The ASM400 is Class 1 and BSM400 is Class 2 with 2 MOPP (method of patient protection) isolation and BF leakage current and have been certified by Underwriters Laboratories for compliance with the latest edition of the international medical safety standard, IEC 60601-1 3rd Edition using the CB reporting scheme. They are also certified to be compliant with the collateral standard 60601-1- 2 for EMC and bear the UL Recognized component marks for North America and the EU and the CE mark. These products operate over the input voltage range of 90 to 264 VAC and 50, 60Hz frequency and produce 400 Watts of regulated DC output power in a standard 3 x 5 (inch) form factor that is 1U height compatible. Page 1 of 7 A(B)SM400S series 08-25- 15 REV.J www.astrodynetdi.com 2015 Astrodyne Corporation

400W High Density Medical/Industrial Grade Open Frame Power Supplies INPUT SPECIFICATIONS Input Voltage Range Range of Nominal Input Voltages Input Frequency Input Current Inrush Current 90-264 VAC 100-240 VAC 47-63 Hz (50/60 Hz Nom.) 4.5 A Max at 115VAC 2.5A Max at 230VAC 30A Max at 115VAC, 60 Hz 60A Max at 230VAC, 50 Hz 300uA Max at 264VAC, 50Hz Earth Leakage Current ASM400S Patient Leakage Current 100uA Max at 264VAC, 50Hz BSM400S BF rating Input Fusing 8A fuse in both L and N lines Power Factor 0.95 min., 230VAC 50Hz MAIN OUTPUT SPECIFICATIONS Output Voltage Output Power Minimum Load Set Point Accuracy Load Regulation Line Regulation Temp. Drift Transient Response Excursion Transient Response Recovery Time Ripple and Noise 12V, 15V, 20V, 24V, 28V, 36V, 48V or 54V nominal 400 W Continuous See temp. & Airflow derating curves No minimum load required ± 1% ± 1% Max, 0 to Full Load ± 0.5% Max, 90 to 264 VAC ± 0.025 %/ C Less than ± 5% 50 to 100% Load Step 1A/us Slew Rate 2ms Max 50 to 100% Load Step 1A/us Slew Rate 1% pk- pk Max. 20MHz BW Measured with 47uF Alum and 0.1uF Ceramic at output OVERALL SPECIFICATIONS Efficiency Standby Power Start- up Delay Start- up Rise Time Refer to Ordering Information table <1W 230 VAC 2s maximum 50ms maximum OVERALL SPECIFICATIONS (cont.) Hold- up Time Power Density Switching Frequency MTBF 16ms typ. Full Load, 115VAC 19 W/in³ 200 KHz typ. 100K hrs. (typ.) per MIL- HDBK- 217F ISOLATION SPECIFICATIONS Input to Output Input to Earth Output to Earth 4000VAC, 2 MOPP 1500VAC, 1 MOPP 500VAC PROTECTION Over Current Inception Short Circuit Over Voltage Protection Over Temperature Protection 105 to 135% Rated Current Hiccup Mode, Automatic recovery 130% Vo max. Latching, Recycle Input to Reset Automatic recovery MECHANICAL SPECIFICATIONS Size Weight Input Connector Input Mating Connector Output Connector Output Mating Connector See Outline Drawings for mechanical options 1lbs. (453.6g) Molex 41791 Housing Molex 2139 Contact 2478 See Outline Drawings for mechanical options See Outline Drawings for mechanical options ENVIRONMENTAL SPECIFICATIONS Operating Temp. Range Storage Temp. Range Humidity - 20 to +40 C at Full Load with derating - 40 to +85 C 0 to 95%, non- condensing Page 2 of 7 A(B)SM400S series 08-25- 15 REV.J www.astrodynetdi.com 2015 Astrodyne Corporation

400W High Density Medical/Industrial Grade Open Frame Power Supplies ENVIRONMENTAL SPECIFICATIONS (cont.) Altitude Shock Vibration 0 to 10,000 ft. 0 to 3048 m 30G pk. Half sine, 6 axis 2 G RMS, 5 Hz to 500 Hz 3 axis, 30 min SAFETY CERTIFICATIONS UL/cUL UL EU AAMI ES60601-1: 2005 A1 2012/CSA 22.2 60601-1 2014 EN60601-1: 2006 3rd Edition A1 2013 CB Scheme IEC 60601-1: 2005 A1 2012 EMC CERTIFICATIONS EMC CERTIFICATIONS (cont.) Radiated Emissions ESD Susceptibility Air Discharge ESD Susceptibility Contact Discharge Radiated Susceptibility EFT/Burst Surge Conducted Susceptibility EN60601-1- 2 Class B EN55011/A1 Class B EN61000-4- 2 Criteria A Level 3 EN61000-4- 2 Criteria A Level 2 EN61000-4- 3 Criteria A Level 2 EN61000-4- 4 Criteria A Level 3 EN61000-4- 5 Criteria A Level 2 EN61000-4- 6 Criteria A Level 2 Conducted Emissions EN60601-1- 2 Class B EN55011/A1 Class B All Specifications are typical at nominal input, full load, 25 C unless specified otherwise. For EMC Compliance, electrically bond 4 mounting holes to a conductive surface. 18mm Air Flow 50mm Ambient Thermal Sensor AC IN PUT PSU DC OUT PUT Note: Keep 6mm minimum between PCB bottom side to system chassis 18mm Page 3 of 7 A(B)SM400S series 08-25- 15 REV.J www.astrodynetdi.com 2015 Astrodyne Corporation

OUTPUT DERATING Output Power Derating Information Natural Convection - Output Power vs. Ambient Temperature and Input Voltage for all models: Forced Convection - Output Power vs. Ambient Temperature, Airflow and Input Voltage: Page 4 of 7

Page 5 of 7

PART NUMBERING INFORMATION: Input Class/Product Family (A or B) A: ASM Class I Input B: BSM Class II Input SM400S DC Output (2 characters) 12: 12V 19: 20V 24: 24V 54: 54V Aux. Output Configuration (0, 1 or 2 characters) Blank: +5V Aux. and +12V Fan Outputs both provided A1: +12V Fan Output provided, +5V Aux. not provided 00: Neither Aux. Output Provided Note: 1. PS-ON: Connect this signal to DC_OUT_RTN to enable the main and FAN outputs. The 5V_AUX output is on when AC is applied. 2. PWR_OK: Open collector logic goes to high 160ms (typ.) after main output is in regulation. Page 6 of 7

MECHANICAL DRAWING Notes: 1. All dimensions in mm (in.) 2. Maximum Dimensions: Length and Width Tolerance is ± 0.2 (0.008) Maximum Height: 36.1 (1.42) Page 7 of 7