User s Manual. Models /437102/437103/437104/ /437112/437118/437124/ µr20000 Recorder Portable Type. IM 04P02B01-51E 1st Edition

Similar documents
User s Manual. Models /436102/436103/436104/ µr10000 Recorder Portable Type. IM 04P01B01-51E 1st Edition. Yokogawa Electric Corporation

User s Manual. FX100(Desktop Type) IM 04L20A01-51E 1st Edition. Yokogawa Electric Corporation. Model FX103/FX106/FX112

Operation Guide Models /436102/436103/436104/ µr10000 Recorder

VC200 Mobile Phone Tester Please Read before Use

User s Manual. Models DX1002/DX1004/DX1006/DX1012/ DX1002N/DX1004N/DX1006N/DX1012N Daqstation DX1000/DX1000N Operation Guide

User s Manual Power Supply IM E. 5th Edition

Customer Maintenance Parts List

MFT Remote Controller

PR Series Paperless Recorders

XL112, XL114 ポータブルデータロガ

DAQSTATION DX100P/DX200P

User s Manual Models MV2008/MV2010/MV2020/MV2030/ MV2040/MV2048 MV2000 First Step Guide

User s Manual Model DX2004/DX2008/DX2010/DX2020/ DX2030/DX2040/DX2048 Daqstation DX2000 Operation Guide

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

User s Manual DAQSTATION DX200. Model DX204/DX208/DX210/DX220/DX230. IM 04L02A01-01E 6th Edition. Yokogawa Electric Corporation

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

User s Manual DAQSTATION DX100P. Model DX102P/DX104P/DX106P/DX112P. IM 04L05A01-01E 4th Edition. Yokogawa Electric Corporation

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

VC3300 Wireless Communication Tester Please Read before Use

Product Documentation

RADCOM s Platform Specifications. Valid from Version 7.10

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Portable Paperless Recorder MV1000/MV2000

MW100 Data Acquisition Unit

RD2000, 5.6" display. All models shown smaller than actual size.

INTELLIGENT SERVER. Model: BMS-LSV6E

Advanced Test Equipment Rentals ATEC (2832)

User s Manual Models FX1002/FX1004/FX1006/FX1008/ FX1010/FX1012 FX1000 First Step Guide

AQ2200 Series Multi-Application Test System Remote Viewer

User s Manual DX1000/DX1000N/DX2000 PROFIBUS-DP (/CP1) Communication Interface

User s Manual DAQSTATION DX200P. Model DX204P/DX208P/ DX210P/DX220P/DX230P. IM 04L06A01-01E 5th Edition. Yokogawa Electric Corporation

Enhanced Mini-Chansim Model VCS-232

Digital Manometer. IM E 2nd Edition

±15 V Current-Limited Power Supply

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Industrial Recorders

General Specifications

RTD. Process Calibrator. User s MANUAL. PDF created with pdffactory Pro trial version

User s Manual Models DX1002/DX1004/DX1006/DX1012/ DX1002N/DX1004N/DX1006N/DX1012N Daqstation DX1000/DX1000N Operation Guide

Time Inter val Analyzer

Daqstation DXAdvanced DX1000/DX2000 DX1000/DX2000. Bulletin 04L41B01-01E.

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

User s Manual Models DX1002/DX1004/DX1006/DX1012/ DX1002N/DX1004N/DX1006N/DX1012N Daqstation DX1000/DX1000N Operation Guide

MODEL 805 USER MANUAL

User s Manual Model FX1002/FX1004/FX1006/FX1008/ FX1010/FX1012 FX1000 Paperless Recorder First Step Guide

POWERCERT PC parameter setting tool (For the PR300, UPM100, and UPM101)

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

User s Manual. PC-Based Measurement Instruments. Setup Guide for Windows Vista IM E. 1st Edition

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

Industrial Recorders. Bulletin 04P01B01-01E

Interface Conversion Adaptor (DVI to LVDS) IA-573-A. User s Manual. Ver.1.02

Multi-batch Function (/BT)

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

Installation manual Digital Energy USB / RS232 / Relay Interface Card for use with GE Digital Energy VH Series UPS VA

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

PR series User Manual

Manual for PSDC_OPT_EIGHT_01: Optics Power Supply

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

Dell MD1280 Storage Enclosure Getting Started Guide

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

DX1000/DX2000. Bulletin 04L41B01-01E.

Operation Guide MX100 Data Acquisition Unit

iologik 4000 Series (M) Modules

Please Read This First. Userʼs Manual. Data Acquisition System GM. First Step Guide

User s Manual. AQ6150/AQ6151 Optical Wavelength Meter Getting Started Guide IM AQ EN. 1st Edition

Model VC-SHIELD Shield Box

SNAP-IT-1U Installation Guide

Daqstation DXAdvanced DX1000/DX2000. Bulletin 04L41B01-01E.

MW100 Data Acquisition Unit

High Power over Ethernet Midspans PD Port Model PD Port Model

EMC1600 Series Media Converter and Ethernet Extender Chassis

Agilent 70612B K18 Switch Matrix

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

APC Next Generation Rack ATS

MT2834BA/BL Series Intelligent Data/Fax Modems. Quick Start Guide

Strip Chart Recorders Specification Sheet

Advanced Test Equipment Rentals ATEC (2832)

MC 11 EB-2 Power supply cabinet with external bus, AC version

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

User s Manual Model /436102/436103/436104/436106/ /437102/437103/437104/437106/ /437118/437124

Line Impedance Stabilization Network (LISN)

DM3058/DM3058E Digital Multimeter

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

USB 2.0 SR. Extender over one CAT-5 Cable. User Manual EXT-USB2.0-SR. Version A1

Universal AC Power Source + AC Power Analyzer

HypotULTRA. Quick Start Guide SAFETY CHECKLIST. Survey the test station. Make sure it is safe & orderly.

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

HYAMP. Quick Start Guide

Version /25/2014. User Manual. PowerLine AV 500 Passthrough Mini Adapter DHP P308AV / DHP-P309AV

ASCO 920 Remote Control (RC) Switches

LBVR1718. Description. Features channel paperless recorder

Network Camera. Installation Manual Before operating the unit, please read this manual thoroughly and retain it for future reference.

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

T1/E1 Channelized Gigabit Router

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

Manual Supplement. Manual Title: ESA609 Users Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13

Transcription:

User s Manual Models 437101/437102/437103/437104/ 437106/437112/437118/437124/ µr20000 Recorder Portable Type * 4 P 2 B 1 5 1 E 0 1 * Yokogawa Electric Corporation 1st Edition

Foreword Notes Trademarks Revisions Thank you for purchasing the µr20000 (hereafter referred to as recorder). This user s manual contains information about the recorder with the /H5x option specification (the portable type). Please also refer to the user s manual for the standard version of the recorder (IM04P02B01-01E) when operating this model. The contents of this manual are subject to change without prior notice as a result of continuing improvements to the instrument s performance and functions. Every effort has been made in the preparation of this manual to ensure the accuracy of its contents. However, should you have any questions or find any errors, please contact your nearest YOKOGAWA dealer. Copying or reproduction of all or any part of the contents of this manual without the permission of Yokogawa Electric Corporation is strictly prohibited. All the brands or names of Yokogawa Electric s products used in this manual are either trademarks or registered trademarks of Yokogawa Electric Corporation. Adobe, Acrobat, and PostScript are trademarks of Adobe Systems Incorporated. The company and product names used in this manual are not accompanied by the trademark or registered trademark symbols ( and ). Company and product names used in this manual are trademarks or registered trademarks of their respective holders. 1st Edition February 2006 1st Edition: February 2006 (YK) All Rights Reserved, Copyright 2006 Yokogawa Electric Corporation 1

Safety Precautions The following describes warnings that are specific to the portable type. Please also refer to pages ii and iii of IM04P02B01-01E for warnings that apply to all models of the recorder. WARNING Power Supply Before connecting the power cord, ensure that the power supply voltage matches the voltage rating for the instrument, and that it is within the maximum rated voltage for the power cord itself. Use the Correct Power Cord and Plug The main power plug can only be plugged into an outlet with a protective grounding terminal. Do not disable the protection feature of the instrument by using an extension cord without protective grounding. Connect the Protective Grounding Terminal Make sure to connect the protective grounding to prevent electric shock before turning ON the power. The power cord included with the portable type is a 3- prong cord with a grounding wire. Connect the power cord to a 3-prong AC outlet with a protective grounding terminal. 2

172608 R TAG NO. TAG NO. TAG NO. TAG NO. SUPPLY MAC NO. STYLE R Checking the Contents of the Package Unpack the box and check the contents before operating the software. If some items are missing or otherwise inconsistent with the contents description, please contact your dealer or nearest YOKOGAWA dealer. Checking the Model Name Check the name plate on the recorder to ensure that the model name and suffix code match the ones you ordered. RECORDER MODEL SUFFIX STYLE C US MODEL SUFFIX C US 172608 SUPPLY N200 FREQUENCY Made in China Do not apply oil N200 FREQUENCY MAC NO. Made in China Model and Suffix Codes Model Suffix Code Optional Code 437101 437102 437103 437104 437106 437112 437118 437124-1 -2-3 /A1 /A2 /A3 /A4 /A5 /C3 /C7 /F1 /H2 /H3 /H5D /H5F /H5R /H5J /H5H /M1 /N1 /N2 /N3 /P1 /R1 /CC1 Description µr20000 1 pen recorder µr20000 2 pen recorder µr20000 3 pen recorder µr20000 4 pen recorder µr20000 6 dot recorder µr20000 12 dot recorder µr20000 18 dot recorder µr20000 24 dot recorder Japanese English/German/French & deg F / DST Chinese & deg F / DST Alarm output relay 2 points 1 Alarm output relay 4 points 1 Alarm output relay 6 points 1 Alarm output relay 12 points 1,2 Alarm output relay 24 points 1,2 RS-422A/485 interface 3 Ethernet (10BASE-T) interface 3 Fail/Chart end detection and output 2 Clamped input terminal 4 Non-glare door glass Portable type Power cord UL, CSA st'd 7 Portable type Power cord VDE st'd 7 Portable type Power cord AS st'd 7 Portable type Power cord BS st'd 7 Portable type Power cord GB st'd 7 Mathematical function Cu10, Cu25 RTD input 3 legs isolated RTD 4,5 Expansion inputs 6 24 VDC/AC power supply 7 Remote control 5 points Calibration correction 1 /A1, /A2, /A3, /A4, and /A5 cannot be specified simultaneously. /A5 is valid on the dot models. 2 /A5 and /F1 cannot be specified simultaneously on the dot models. /A4 and /F1 cannot be specified simultaneously on the pen models. 3 /C3 and /C7 cannot be specified simultaneously. 4 /H2 and /N2 cannot be specified simultaneously. 5 Valid only on the dot models. 6 14 types of input including Pt50 RTD, PR40-20, and Platinel TC 7 /H5x and /P1 cannot be specified simultaneously. 3

Checking the Contents of the Package Standard Accessories Power cord /H5D /H5F /H5R /H5J /H5H One of these power cord types is supplied according to the instrument s suffix code Part Number Q ty Note A1006WD 1 Provided when /H5D is specified for the optional code. Maximum rated power voltage: 125V A1009WD 1 Provided when /H5F is specified for the optional code. Maximum rated power voltage: 250V A1024WD 1 Provided when /H5R is specified for the optional code. Maximum rated power voltage: 250V A1023WD 1 Provided when /H5J is specified for the optional code. Maximum rated power voltage: 250V A1064WD 1 Provided when /H5H is specified for the optional code. Maximum rated power voltage: 250V For information on standard accessories besides the power cord and optional accessories (sold separately), see page v of the user s manual, IM04L02B01-01E. 4

Installation and Connecting the Power Supply Installation The following describes warnings that are specific to the portable type. For all other details regarding installation, see section 2.2 of IM04L02B01-01E, Installation. Precautions Regarding the Installation Location The portable type is not equipped to be installed in an instrumentation panel. For the portable type, we recommend that you maintain a 50 mm or greater margin of space around the front, back, sides, and top of the instrument. This instrument is for indoor use only. Do not use the instrument outdoors. Connecting the Power Supply Points to Note When Connecting the Power Supply Please heed the following warnings when connecting the power supply to the instrument. Failure to heed the following warnings may result in electric shock or damage to instruments. WARNING Ensure that the source voltage matches the rated power supply voltage of the instrument before connecting the power cord. Check that the power switch to the instrument is turned OFF before connecting the power cord. Make sure to connect protective earth grounding to prevent electric shock. Connect the power cord of the portable type to a three-prong power outlet equipped with a protective earth terminal. Do not use an extension cord that does not have a protective grounding wire. The protective features of the instrument will be rendered ineffective. Use a power supply that meets the conditions indicated below. Item Condition Rated supply voltage 100 to 240 VAC Supply voltage range used 90 to 132, 180 to 264 VAC Rated supply voltage frequency 50/60 Hz Permitted supply voltage frequency range 50/60 Hz ±2% Maximum power consumption Pen model: 55 VA, dot model: 55 VA Note Do not use a supply voltage in the range 132 to 180 VAC, as this may have adverse effects on the measurement accuracy. 5

Installation and Connecting the Power Supply Connections 1. Check that the power switch to the instrument is turned OFF. 2. Connect the plug on the accessory power cord to the power supply connector on the rear panel. 3. Ensure that the power outlet to be used meets the conditions on the previous page and that the voltage of the power supply is within the maximum voltage rating of the power cord, then connect the other end of the power cord to the power supply outlet. The AC outlet must be of a three-prong type with a protective earth ground terminal. 6

Names of Parts The following describes only the names of parts that are specific to the portable type. For all other part names, see section 3.1 of IM04P02B01-01E, Names of Parts and Functions. 1 Rear Panel 1. Carrying handle 2. Protective ground terminal (spare) 3. Power terminal with protective ground terminal (attach the specified power cord) 4. Feet (four) 2 3 4 7

Specifications and Dimensional Drawings Specifications The following describes specifications that are specific to the portable type. For other specifications, see chapter 12 of IM04P02B01-01E, Specifications. Dimensional Drawings Portable Type (/H5x) Carrying handle The x in /H5x designates the power cord specification. D: Power cord (UL and CSA compliant) F: Power cord (VDE compliant) R: Power cord (SAA compliant) J: Power cord (BS compliant) H: Power cord (GB compliant) 267.5 (10.53) 180.5 (7.11) 87 (3.43) 288 (11.34) 284 (11.18) 329.7 (12.98) 288 (11.34) 12.7 (0.5) 8