232iLM Keypad Installation and Programming Instructions

Similar documents
232iLM Keypad Installation & Programming Instructions

212iL Rev. 1.1

2000 Series e/em Style Keypad Installation and Programming Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

KP2000E/EM Series Style Keypad

FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS:

9212i INSTALLATION. Stand-Alone Keypad. Instructions

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Outdoor Stand-Alone Weatherproof Keypads

Digital Keypad Introduction

Enter a new user. code. Enter. Enter a 2-digit user ID. Enter a user code. (from 00~09) (from 00~09) Enter

DP-222Q Color Video Door Phone Manual

DP-222Q Color Video Door Phone Manual

DOLXFD1000B. Waterproof Access Control/Reader

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

CM-110SK Standalone Keypad Installation Instructions

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

SK-1011-SQ Digital Access Keypad with 5A Relay Output

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

IEI prox.pad Proximity Reader/Keypad Access Control Installer Guide

SKE Series. 12-Pad. Installation & Instruction Manual. Essex Electronics, Inc KEY-LESS fax keyless.

AP41 / AP81 SERIES TIME SWITCHES

poly-planar Marine Audio System

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

STYLE 3600 SWITCH INTERFACE TRANSMITTER INSTALLATION AND OPERATING INSTRUCTIONS

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

IEI prox.pad Proximity Reader/Keypad Access Control Installer Guide

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

AEXX-349 SERIES REMOTE DISPLAYS

CP150B Vandal & Weather Resistant Keypad Security Systems

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

MODEL 710. Ground Support Intercom INSTALLATION/OPERATION MANUAL

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

Installation Instructions 4291 and 4292 Keypads

Series 803 LED Product Price Display

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

AE21 SERIES DISPLAY CONTROL TERMINAL

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Wireless Doorphone Intercom

MS-7000: SuperStar Reader

A-100 INDOOR STAINLESS STEEL KEYPAD WIRING & PROGRAMMING INSTRUCTIONS

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

K-PROX Series INSTALLATION & INSTRUCTION MANUAL. Essex Electronics, Inc KEY-LESS fax keyless.com

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

BTU 4 & Sensors. Installation and Operation Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

SK-1011-SDQ Access Control Keypad. Manual

INTELLIGENT DOCKING STATION USERS MANUAL

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

MS-3000 MicroStar Reader

MINI 4200 Model # - C Mini Instruction Manual V.2. This instruction manual serves as a guide for the Mini 4200.

MODEL 9266 LITTLE LEAGUE BASEBALL SCOREBOARD. Instruction Manual

MR51e Reader Interface

OPERATIONS MANUAL PCM-DOC

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

DP4 DOOR PHONE. For Technical Assistance Please Phone: (07)

Waterproof. Keypad/Reader/Controller

User Guide. Control Box. RoscoLED TM.

User Manual. PCKeypad Wireless Keypad

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

Kodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY

EL-ST100 KEYPAD CONTROLLER

MS-5000: MiniStar Reader

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

poly-planar Marine Audio Systems

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

OPERATIONS MANUAL PCM-I/O48

Proliphix EPA-60 Installation Guide

MRDT Display Terminal

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installing Keypad and Backplate

Digital Lighting Systems, Inc.

PMDX-105 Quad Isolator Board

Long range Multi Reader AY-Z12A Installation Guide

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

LitePad Vector User s Guide

INSTRUCTION MANUAL FN-8118 SCAN HERE

User Manual CS-SA Series 'SUPER ANALOG' Time Fade Stations JOHNSON SYSTEMS INC.

Installation Instructions

SA-027WQ. Manual. 7-Day Timer. Lighting Systems Access Controls Security Systems Environmental Controls. Automate the following:

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

MR52 READER INTERFACE

Installation Instructions for the Blue Dot Lock Door Controller

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

EVERSAN. Instruction Manual MODEL 9007/9008 TENNIS SCOREBOARD. Address: 34 Main Street, Whitesboro, NY 13492

icp installation guide

Transcription:

232iLM Keypad Installation and Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Case Dimensions: 6 1 / 2 L x 1 3 / 4 W x 1 1 / 8 D Electrical: Voltage: 5-12VDC (reader) 12-24VAC/DC (controller) Current (max): 120mA Relay Contacts: Main Relay (controller): 2A Aux Relays (controller): 1A Bell Relay: Form A; 1 Amp @ 30VDC; 500mA @ 125VAC Features Vandal Resistant Case Sealed for Indoor or Outdoor Applications LED's for Relay Status Indication Bell Output Surface Mount Illuminated Hardened Keys Rated for Greater than One Million Key Cycles Applications Low to Medium/Heavy Traffic Areas Rough Service Environments Mullion Frame Mounting Dimly Lit Areas Environmental: -20 º F to 130 F Description: Wire Harness Configuration: The 232iLM Access Control unit consists of two pieces: an SSWiLM keypad front end and a 232 Access Control Module. IEI's Door-Gard Series SSWiLM keypad combines elegant looks with a mullion mount design in a rugged, vandal resistant case, which you can use for almost any application. The SSWiLM has hardened backlit keys designed to perform in medium to high traffic areas and in rough duty environments. The electronics are also conformal coated, which makes the keypad suitable for indoor or outdoor applications. Basic Operation: To gain access through the door enter your code (1-6 digits) followed by the * key on the keypad. Packing List: (1) SSWiLM Keypad (1) IEI 232 Controller (1) Eight-Conductor Wire Harness (4) Three-Conductor Wire Harness (1) Controller Hardware Pack (1) Mullion Hardware Pack (1) 5 / 64 Allen Wrench (1) Anti-Oxidant Grease Pack (1) Installation/Programming Manual (1) Self-Contained Access Control Programming Guide Pin Wire Color Signal Name 1 Red Power (+) 2 Black Power (-) 3 White/Black Data 0 4 White/Yellow Data 1 5 Blue Not Used 6 Brown Not Used 7 White Bell Relay Contact (A) 8 White Bell Relay Contact (B) Wiring Requirements: 18 AWG 1000 Ft. 20 AWG 500 Ft. 22 AWG 250 Ft. Document # 6050800 Rev 1.1 1 of 12 www.ieib.com

Keypad Installation Procedure: Step 1: Drill through the back plate using a 11 / 64 bit. Use the template on the back page to accurately mark the mounting holes before drilling. Then drill the mounting holes with a 9 / 64 drill bit. Also drill the hole for the wires. This may vary depending on the number of conductors required. Step 2: On the keypad end, strip back the insulator from the wire and tape the drain wire (shield) to the jacket. Now connect the required wires to the 8-conductor wire harness provided. The wire harness plugs into the 8-position connector on the keypad. At the other end of your wire run, strip back the insulator from the wire but do not tape the drain wire to the jacket. The drain wire must be connected to ground at the controller end. See the diagrams below. Step 3: Finally mount the SSWiLM keypad onto the mounting surface using the provided screws. Do no over-tighten the screws, which may result in damage. Wiring the SSWiLM to an IEI 232 Access Control Module The connection between the SSWiLM and the 232 Controller requires a 4-conductor, stranded wire with overall foil shield. The 8-conductor wire harness from the keypad connects to connector P6 on the controller. Connect the wires, color to color (red to red, black to black, white/black to white/black and white/yellow to white/yellow). Refer to the wire lengths on the first page. As mentioned above, the drain wire must be attached to Ground on the controller side, which is the V- terminal or negative of your power supply. Document # 6050800 Rev 1.1 2 of 12 www.ieib.com

Basic Access Control Using an Electromagnetic Lock (Maglock) If you aren't using door contacts you must short the white/orange and white wires IEI recommends a filtered and regulated DC power supply. Basic Access Control Using an Electric Door Strike If you aren't using door contacts you must short the white/orange and white wires IEI recommends a filtered and regulated DC power supply. Document # 6050800 Rev 1.1 3 of 12 www.ieib.com

Integrated Access Control Wiring IEI recommends a filtered and regulated DC power supply. Wire Color Gray Blue Green Relay Connection Normally Closed Common Normally Open Document # 6050800 Rev 1.1 4 of 12 www.ieib.com

Wiring the Bell Output to a Speaker: The SSWiLM keypad has a built in bell button, which triggers a relay output when pressed. This relay is normally open and the contact closes when triggered. You can use this relay output to trigger devices that require a momentary closure, such as a doorbell. The relay output provides a dry contact, but you can run up to 24 VDC or 125 VAC through it for devices that require power to operate. The diagram below shows these connections. Keypad Mounting Height Mounting height can vary depending on requirements. An appropriate range is typically between 48 and 52 inches on center off the floor. Document # 6050800 Rev 1.1 5 of 12 www.ieib.com

Programming the SSWiLM Keypad The SSWiLM keypad has it's own local programming options. All user codes and other access control features are programmed into the controller. Refer the Self-Contained Access Control Programming Guide for those features. The programming options chart below shows all the programming commands available in the SSWiLM. To program the SSWiLM you first must enter program mode. To enter program mode enter the following on the keypad: 099 # program code * (default program code is 6789). Keypad Default Settings Option Default Setting Option Default Setting Local Program Code 6789 Audio Keypress Feedback Enabled Visual Keypress Feedback Enabled Door Bell Select Continuous Keypad Illumination Enabled Keypad Dimming Enabled Programming Options Chart Command/Action Command 90 Change Local Program Code Command 91 Set/Clear Keypad Options (options below, defaults in bold) Keys to Enter/Details 90 # 0 # 0 # new code * new code * (default = 6789) 91 # option # set/clear # ** Option Clear Set 0 Visual Keypress Feedback 0 = Disabled 1 = Enabled 1 Audio Keypress Feedback 0 = Disabled 1 = Enabled 11 Keypad Illumination 0 = Disabled 1 = Enabled 12 Keypad Dimming 0 = Disabled (always bright) 1 = Enabled 13 Door Bell Select 0 = Disabled 1 = Enabled Command 92 Set Door Bell Duration Command 96 Reset Keypad to Default Settings Exit Program Mode 92 # 4 # time # ** Set timed output (1 99 seconds) 92 # 4 # 0 # ** Set to continuous 96 # 0 # 0 # ** Press the * Key Testing the Keypad After installing the keypad, IEI recommends that you perform the keypad self-test once a year, to ensure that the keypad is working properly. To perform the self-test, with the unit powered up, press the following keys on the keypad: 7890#123456* If all 12 keypresses are accepted, the keypad enters self-test mode. The LEDs alternate three times followed by the sounder beeping three times. When finished the yellow LED starts flickering rapidly. Press * to clear. Document # 6050800 Rev 1.1 6 of 12 www.ieib.com

LED Indications LED State Red Solid Green Solid Yellow Solid Yellow Flashing Slowly (single flash) Yellow Flashing Slowly (double flash) Yellow Momentary Flash Description Door Locked Door Unlocked Programming Error Controller Program Mode Front End Program Mode Visual Keypress Feedback Replacing the 232m (discontinued) with an 232iLM The 232iLM is functionally equivalent to the 232m keypad, which was discontinued. It's not, however, a direct physical replacement. They are both two piece units, but they use a different control boards. It is not possible to replace just the mullion keypad portion of the unit. You must replace the entire unit. Refer to the previous sections for wiring your new 232iLM unit. Program Mode Loopback If you've forgotten the local program code use the following loopback connection to enter program mode. Power down the unit, short the wires in the configuration illustrated, then power the unit back up. The yellow LED should be flashing. Now change your local program code or reset the unit. Power the keypad down and reconnected the wire harness in the original configuration. Document # 6050800 Rev 1.1 7 of 12 www.ieib.com

Warranty International Electronics Inc. (IEI) warrants its products to be free from defects in material and workmanship when they have been installed in accordance with the manufacturer's instructions and have not been modified or tampered with. IEI does not assume any responsibility for damage or injury to person or property due to improper care, storage, handling, abuse, misuse, normal wear and tear, or an act of God. IEI's sole responsibility is limited to the repair (at IEI's option) or the replacement of the defective product or part when sent to IEI's facility (freight and insurance charges prepaid) after obtaining IEI's Return Material Authorization. IEI will not be liable to the purchaser or any one else for incidental or consequential damages arising from any defect in, or malfunction of, its products. Except as stated above, IEI makes no warranties, either expressed or implied, as to any matter whatsoever, including, and without limitation to, the condition of its products, their merchantability, or fitness for any particular purpose. International Electronics Inc. 427 Turnpike St. Canton, MA 02021 Phone: 1-800-343-9502 Fax: 781-821-4443 Website: www.ieib.com Document # 6050800 Rev 1.1 8 of 12 www.ieib.com

PAGE LEFT BLANK INTENTIONALLY Document # 6050800 Rev 1.1 9 of 12 www.ieib.com

PAGE LEFT BLANK INTENTIONALLY Document # 6050800 Rev 1.1 10 of 12 www.ieib.com

PAGE LEFT BLANK INTENTIONALLY Document # 6050800 Rev 1.1 11 of 12 www.ieib.com

ilm Mounting Template Document # 6050800 Rev 1.1 12 of 12 www.ieib.com