LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Similar documents
SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

PRO-75 SERIES. User manual

XTM1250SA DIN rail three phase four wire LCD display energy meter

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter

PRO1250D CT M-bus MID DIN rail three phase four wire energy meter. User manual Version 1.11

1.2 Foreword. 1.7 Basic errors. 1.8 Description. 1.9 Dimensions Installation Operating

PRO1250D CT MODBUS MID Three phase four wire energy meter.

PRO2DM DIN rail single phase two wire energy meter

METERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

OB735 Smart Energy Meter

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

PRO1-S PRO1-2T PRO1-Mb PRO1-Mod. PRO1 Series MID Single phase energy meter. User manual. Product version: Inepro B.V. All rights reserved

PRO1-S PRO1-2T PRO1-Mb PRO1-Mod. PRO1 Series MID Single phase energy meter. User manual. Version: Inepro B.V. All rights reserved

Operating Manual -ENGLISH- Page 1 KWG-ISO

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

User Manual V1.0 SDM230-DR. Single-Phase Two Module DIN rail Meters

Switched Mode Power Supply Operating manual PAP800

PV Rapid Shutdown device

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

CEM-C6 INSTRUCTION MANUAL (M187B B)

Operating instructions. Speed monitor D / / 2014

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

CEM-C30 INSTRUCTION MANUAL (M017B A)

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Trusted Output Power Distribution Unit (Diode Protected)

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Operating instructions. Standstill monitor A / / 2011

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Operating instructions. Switching amplifier DN0210 DN / / 2015

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Smart Grid Tie Microinverter User Manual

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

CG800H SERIES USER MANUAL ZIGBEE WIRELESS SCENE CONTROL PANEL VERSION JANUARY, Disclaimers and Copyright

K1B004TLH cam switch - 1 pole A - screw mounting

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

SPM91 DIN Rail Single Phase Energy Meter Installation & Operation Manual V1.0

OPERATING INSTRUCTION

K1D012ULH cam changeover switch - 2-pole A - screw mounting

High Speed Remote I/O Module

Trusted Power Distribution Unit 15-Way Fused

Smart Energy Meters Noark Electric Europe s.r.o.

SAVE THESE INSTRUCTIONS

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

3700 SERIES USER MANUAL

Siemens Industrial s

22-60VDC Grid Tie Microinverter User Manual

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

POCKET MULTIMETER Model No: MM18

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Trusted High Integrity Power Supply System ( Vac and 24 Vdc)

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Installation Manual. BN interface. Model name: BMS-IFBN640TLUL. English

Octostrip ORDERCODE 42220

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Touch-controller_IM_03943A_1_Co_EN.indd 오후 3:06:00

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

V E1B Snap-in I/O Module

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

CEM M-ETH INSTRUCTION MANUAL (M060B A)

Vision OPLC V TR6/V350-J-TR6

V E1B Snap-in I/O Module

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Trusted 40 Channel Digital Input Versatile FTA

PanelView Plus/VersaView CE Terminals and Display Modules

PM Series Power Meter

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL


Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Transcription:

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Structure Diagram 1.7 Dimensions 1.8 Installation 1.9 Operating 1.10 Troubleshooting 1.11 Technical support User manual

1.1 Safety instructions Information for Your Own Safety This manual does not contain all of the safety measures operating the equipment (module, device) for different conditions and requirements. However, it does contain information which you must know for your own safety and to avoid damages. This information is highlighted by a warning triangle indicating the degree of potential danger. Warning It means that failure to follow the instruction can result in death, serious injury or considerable material damage. Caution It means hazard of electric shock and failure to take the necessary safety precautions will result in death, serious injury or considerable material damage. Qualified personnel Operation of the equipment (module, device) described in this manual may only be performed by qualified personnel. Qualified personnel in this manual means person who are authorized to commission, start up, ground and label devices, systems and circuits according to safety and Regulatory standards. Use for the intended purpose The equipment (device, module) may only be used for the application specified in the catalogue and the user manual. Proper handling The prerequisites for perfect, reliable operation of the product are proper transport, proper storage, installation and proper operation and maintenance. When operating electrical equipment, parts of this equipment automatically carry dangerous voltages. Improper handling can therefore result in serious injuries or material damage. Use only insulating tools. Do not connect while circuit is live. Do not connect the meter to a 3 phase - 400VAC network. Place the meter only in dry surroundings. Do not mount the meter in an explosive area or expose the meter to dust, mildew and insects. Make sure the wires are suitable for the maximum current of this meter. Make sure the AC wires are connected correctly before activating the current/voltage to the meter. Do not touch the meter connecting clamps directly with metal, blank wire and your bare hands as you may get electrical shock. Make sure the protection cover is placed after installation. Installation, maintenance and reparation should only be done by qualified personnel. Never break the seals and open the front cover as this might influence the function of the meter, and will cause no warranty. Do not drop, or allow strong physical impact on the meter as the high precisely components inside may be damaged.

Disclaimer We have checked the contents of this publication and every effort has been made to ensure that the descriptions are as accurate as possible. However, deviations from the description cannot be completely ruled out, so that no liability can be accepted for any errors contained in the information given. The data in this manual is checked regularly and the necessary corrections are included in subsequent editions. Subject to technical modifications without notice. Copyright It is prohibited to pass on or copy this document or to use or disclose its contents without our express permission. Any duplication is a violation of the law and subject to criminal and civil penalties. All rights reserved, particularly in the event of a patent award or utility model registration. 1.1 Performance criteria: Operating humidity 75% Storage humidity 95% Operating temperature -10 C - +50 C Storage temperature -30 C - +70 C International standard IEC 62053-21 Accuracy class 1 Protection against penetration of dust and water IP51 Insulating encased meter of protective class Ⅱ 1.2 Specifications: Meter type LXEM145 LCD (LCD display) Nominal voltage (Un) 230V AC Operational voltage 161-300V AC Insulation capabilities: - AC voltage withstand 2KV for 1 minute - Impulse voltage withstand 6KV 1.2µS waveform Basic current (Ib) 5A Maximum rated current (Imax) 45A Operational current range 0.4% Ib- Imax Over current withstand 30Imax for 0.01s Operational frequency range 50Hz ±10% Internal power consumption 2W / 10VA Test output flash rate (RED LED) 2000imp/kWh Pulse output rate (pins 20 & 21) 2000imp/kWh Consumption indicator (RED LED) Flashing at load running 1.3 Basic errors: 0.05Ib Cosφ = 1 ±1.5% 0.1Ib Cosφ = 0.5L ±1.5%

Cosφ = 0.8C ±1.5% 0.1Ib - Imax Cosφ = 1 ±1.0% 0.2Ib - Imax Cosφ = 0.5L ±1.0% Cosφ = 0.8C ±1.0% 1.4 Description A B C D E LCD Terminal block Case Protection cover Security hasp Material Register Case Terminal block Protection cover PC inflammable retarding ABS inflammable retarding ABS inflammable retarding ABS inflammable retarding C B A D E 1.5 Dimensions Height Width Depth Weight 117.5. mm 18. mm 58.5 mm 0.12 Kg (net) 1.6 Installation

CAUTION Turn off all the power before working on it. Always use a properly rated voltage sensing device to confirm that power is off. WARNING Installation should be performed by qualified personnel familiar with related procedures and regulations. Use insulating tools to install the meter. Fuse or thermal cut-off or single-pole circuit breaker can t be fitted on the supply line and not the neutral line. The case is sealed, do not broken it We recommend that the connecting wire which is used to connect the meter to the outside circuit should be sized according to local codes and regulations for the capacity of the circuit breaker or over current device used in the An external switch or a circuit-breaker should be installed on the inlet wire, which will be used as a disconnection device for the meter. And there it is recommended that the switch or circuit-breaker is near the meter so that it is more convenience for the operator. The switch or circuit-breaker should comply with the specifications of the building electrical design and all local regulations. An external fuse or thermal cut-off which will be used as a over-current protection device for the meter must be installed on the supply side wire, and it is recommended that the over-current protection device is near the meter so that it is more convenient for the operator. The over-current protection device should comply with the specifications of the buildings electrical design and all local regulations. This meter can be installed indoor directly, or in a meter box which is waterproof outdoor, subject to local codes and regulations. To prevent tampering, secure the meter with a padlock or a similar device. The meter has to be installed against a wall which is fire resistant. The meter has to be installed in a good ventilated and dry place. The meter has to be installed in a protection box when placed in dangerous or dusty environment. The meter can be installed and used after being tested and sealed with a letter press printing. The meter can be installed on a 35mm DIN rail. The meter should be installed in an available height so that it is easy to read. When the meter is installed in an area with frequent surges due to e.q. thunderstorms, welding machines, inverters etc, protect the meter with Surge Protection Devices. After finishing installation, the meter must be sealed to prevent tampering. Connection of the wires should be done in accordance with the underneath connection diagram.

1 Inlet phase line 4 Inlet neutral line 3 Outgoing phase line 6 Outgoing neutral line 20 and 21 Pulse output contact 1.7 Operating Consumption indication There is a LED which has two colors (green and red) while flashing in the front panel of LXEM145 series. When consumption happens, the LED will flash and display red. The more quickly LED flash, the more consumption there is. Reading the meter The LXEM145 series energy meter is equipped with a 5+1 register. five integers are marked with black color and one decimal is marked with red. The DRS-201D LCD series energy meter is equipped with 5+2 LCD display which is used as recording consumption and can t be reset to zero. The reading accuracy is 1/100 kwh. Pulse output The LXEM145 Series DIN rail energy meter is equipped with a pulse output which is fully separated from the inside That generates pulses in proportion to the measured energy for accuracy testing. The pulse output is a polarity dependant, passive transistor output requiring an external voltage source for correct operation. For this external voltage source, the voltage (Ui) should is 5-27V DC, and the maximum input current (Iimax) is 27mA DC. To connect the impulse output, connect 5-27V DC to connector 20 (anode), and the signal wire (S) to connector 21 (cathode). 1.10 Troubleshooting CAUTION During reparation and maintenance, do not touch the meter connecting clamps directly with your bare hands, with metal, blank wire or other material as you may get electricity shock Turn off all powers supplying the energy meter and the equipment on which the meter installed before opening the protection cover to avoid getting electric shock. WARNING Maintenance or reparation should be performed by qualified personnel familiar with applicable codes and regulations. Use insulated tools to maintain or repair the meter. Make sure the protection cover is in place after maintenance or reparation. Case is sealed, failure to observe this instruction can result in damage for meter.

Problem Check Solution No light for the Power supply indicator. Is AC power supply connected to the meter? Check switch or circuit-breaker and fuse or thermal cut-off. No light for the consumption indicator. The register can t run. No pulse output. Pulse output rate wrong. Is the 1 and 4 connecting correct? Is the load running? Is the operating power too low? Is there a power supply inside the meter? Is the operating power too low? Is DC power supply connected to the meter? Is the connecting correct? Reinstall terminal screws on the 1 and 4. Make sure all screws are fixed. Than there should be a 230V 50Hz AC voltage between the terminal screws on the 1 and 4 when power supply is input. Please contact your technical supporter to replace this meter. Only when load is running, this LED will flash. If the operating power is too low, the spacing interval of flashing will take some more time, this is why it seems like LED isn t burning. Please contact your technical supporter to replace this meter. Check that the power supply indicator is on. If the operating power is too low, the spacing interval of the pulses will take some more time, this is why it seems like the meter won t count. Please contact your technical supporter to replace this meter. Check the external voltage source (Ui) is 5-27V DC. Check correct connecting: connect 5-27V DC to connector 20 (anode), and the signal wire (S) to connector 21 (cathode). Please contact your technical supportr to replace this meter. Please contact your technical support to replace this meter.