DANGER. Risk of fire, electric shock, and injury. DO NOT insert or drop any object in openings, this could cause unit failure or

Similar documents
CUS150M1 Instruction Manual

ELV12 Series. Instruction Manual

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

Instruction Manual. TDK Lambda INSTRUCTION MANUAL

Instruction Manual. DANGER Never use this product in locations where flammable gas or ignitable substances are present.

CUS1500M. Instruction Manual

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

S8VE (60/90/120/180/240-W Models)

An ISO 9001 Company. HWS , HWS , HWS , HWS , HWS Zero Up Programmable Power Supply

Switch Mode Power Supply

GXE600 Series. Instruction Manual

The power factor of the typical switching power supply is between 0.4 and 0.6.

Basic Characteristics Data

500Watts Medical Single Output

Voltage Current Front-mounting bracket

Basic Characteristics Data

TDK-Lambda CUS30M Series INSTRUCTION MANUAL

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Operating instructions Evaluation system for flow sensors VS / / 2013

EVS300W/600W Series. Instruction Manual

Over voltage protection: Output shutdown (V1 only) Weight: 730g

Basic Characteristics Data

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Basic Characteristics Data

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

SWT SERIES. Features. Model naming method SWT Applications. Conformity to RoHS Directive. Product Line up. Triple Output 30W - 100W SWT A-273

PMT. Safety Standards. Model Number:

Instruction Manual. TDK Lambda. RWS 50B 600B Series INSTRUCTION MANUAL

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

CPFE1000F SERIES POWER SUPPLY OPERATION MANUAL

3000W Programmable Single Output AEK AEK AEK AEK

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

12-15VDC (12V±5%) 24-28VDC (24V±5%)

PMT. Model Number: CC Code PM 24V 200W 1 A Panel Mount Product Type T Enclosed L L Frame*

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

High Speed Remote I/O Module

Safety Standards. Model Number:

Ultra Slim Relays 24

KEPCO SINGLE OUTPUT, 1U SIZE, 100 WATT HOT SWAP PLUG-IN POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1UR 100W SERIES

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Analog Monitor Installation Manual

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

UL TEST REPORT AND PROCEDURE

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

SPECIFICATION. For SWITCHING POWER SUPPLY M/N: MPD-F113-V

Basic Characteristics Data

Snaptec Australia Pty. Ltd.

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

CLP0224 SERIES 200 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.40

Standards VDE: EN60950; UL1950; C-UL: CSA C22.2 No.234; IEC950; VDE0805

MINI-PS AC/10-15DC/8

PMC. PMC Panel Mount Power Supply 24V 50W 1 Phase / PMC-24V050W1A. Highlights & Features. Safety Standards. Model Number: General Description

Switching Power Supply

PMF. Safety Standards. Model Number:

EFE300 / EFE400 EFE300M / EFE400M

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

EFE300 / EFE400 EFE300M / EFE400M

PRODUCT SPECIFICATION. PC Board Relays. Series.

Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-24V100W1AX Vac ( Vdc) 24Vdc 4.17A

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Analog Input Installation Manual

CCPF-3500-XX OPERATION MANUAL. Lumina P/N

Safety Standards. Model Number:

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Table of Contents. 1 General 1.1 Scope

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

File E Project 00SC September 27, 2000 REPORT COMPONENT - POWER SUPPLIES, MEDICAL AND DENTAL EQUIPMENT

Series MPM-815H 150W PFC MEDICAL ATX POWER SUPPLY

PMT. Safety Standards. Model Number:

TOS-SN-1 Extended Panel Operation Manual

< 50 A max. (115 VAC) / < 70 A max. (230 VAC)

Basic Characteristics Data

AC/DC Power Supply Single Output

UL TEST REPORT AND PROCEDURE

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

AC/DC Power Supply Series APPLICATION NOTE

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Installation, Operation and Maintenance Manual

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Operating instructions. Switching amplifier DN0210 DN / / 2015

Barriers. EB3N Discrete Input Barrier with Redundant Output

Installation Instructions Model LFMWLT450, Class 1 Series AC-DC Power Supply

Basic Characteristics Data

PMT. PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A. Highlights & Features. Safety Standards. Model Number: General Description

Conductive Level Controller

Model Number Structure

High Power Electronic Gear Installation and operation Guide

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-12V060W1NA Vac ( Vdc) 12Vdc 5.

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

EX-RC1 Remote I/O Adapter

PMT. Safety Standards. Model Number:

TEK360M series is a fan-less 300W, U-frame, switching power supply with active PFC function for medical application. Rated Output Power.

Signal Doublers. VariTrans A 20300

Transcription:

LFS50A Series Instruction Manual Prior to Use Please read this instruction manual carefully. Please use product only as directed or severe damage to the product may occur. Not properly following these guidelines may result in extremely hazardous conditions that could cause electric shock or fire. WARNING Do not modify the product nor remove the protective enclosure. Under the protective enclosure are contained high voltage and high temperature components during normal operation and after complete shutdown. Avoid electric shock or burns by avoiding them. Keep face and hands away at all times during operation to avoid unexpected injury. DANGER. Risk of fire, electric shock, and injury. DO NOT continually operate if there is smoke, odor, or irregular noise. Instead immediately turn off the power and contact us. Do not attempt to repair it yourself because it is dangerous to do so. DANGER. Risk of fire, electric shock, and injury. DO NOT insert or drop any object in openings, this could cause unit failure or severe hazardous conditions. DANGER. Risk of fire, electric shock, and injury. DO NOT use the product with condensation present, this could result in electric shock or fire. CAUTION UL609501, #E237238 UL606011, #E320635 RoHS Compliant This power supply is intended to be used as a component of a larger system of electrical equipment. User is responsible for the safe design when this product is to be integrated in the equipment which requires particularly high quality and reliability. There is a possibility to endanger persons or property by a failure or malfunction of this product. Ensure and maintain input voltage, output current, output power, ambient temperature, and humidity within specification or unit may be damaged. Ensure that wires are properly secured to the input and output terminals as specified in this manual. Incorrect wiring or poor connection may cause a failure. Be sure to turn off the power before making the output connection. DO NOT use in a special environment (e.g. in the presence of strong electromagnetic field or erosive gas) or environment where conductive foreign substance is present. DO NOT use or store product where condensation may occur due to moisture or humidity. For use in such conditions, waterproof protection is necessary and must be installed. Do not operate under over current or shortcircuit conditions for more than 10 seconds otherwise damage and electrical insulation failure will likely result. No stress (e.g. twist, deflection) should be applied to the print board when the product is installed. Avoid impacts, such as dropping this product. Do not apply the load to signal connector CN501. DANGER. Output of this product is regarded as hazardous energy so this should not be accessible to end users. Use appropriate connecters for the terminal connection. For the crimping of the contact, use the crimping tool recommended by the manufacturer. Prevent accidental contact with the output terminal of this product from dropped items such as tools by insuring proper orientation and shielding/cover. Turn off the input power and ensure that the input and output terminal voltage drops to zero before repair. For the use in medical equipment CAUTION When using this product based on the IEC 606011standard, a fuse or overcurrent breaker must be provided on each input line. These products are not suitable for use in the presence of flammable anesthetic mixtures with oxygen or with nitrous oxide. Although these products have not been assessed to IEC/EN/UL6060112(EMC), EMC test data is available.

Boardside 基板側 1. Terminal Ensure AC power is off prior to connecting inputs and outputs. Connect the functional ground terminal to earth terminal of device or equipment. Route AC and DC wires separately to minimize noise. Be sure to use each terminal (pole) of the terminal block at 20A or less. TERMINAL BLOCK (TB101) Connector CN501 L : AC Line 1 S : Output Remote Sensing N : AC Neutral 2 VS : Output Voltage Check : Frame Ground 3 S : Output Remote Sensing V : Output terminal 4 VS : Output Voltage Check V : Output terminal 5 VR : External Output Voltage Adjustment 6 VR : External Output Voltage Adjustment Terminal screws area all M3.5. 7 R : Remote Control ON/OFF 8 R : Remote Control ON/OFF CN502(not included) Connector : S8BPHDSS(JST) Housing : PHDR08VS (Terminal) : SPHD001TP0.5 Crimping tool : APK2N For proper connection to CN501 please assemble CN502 (not included) using parts above Output Voltage Check LED 出力電圧確認用 LED CN501 拡大図 CN501(Enlarged) 2 4 6 8 1 3 5 7 Output 出力電圧可変ボリューム Adjustment Potentiometer 5 4 3 2 1

2.Functions 21 Input voltage 25 Overvoltage protection (OVP) AC input voltage range: Single phase 85 to 264V AC (47 to 63Hz) During an over voltage fault OVP circuitry will disable output To avoid damage, please use within the recommended range. until fault is removed and unit is allowed to reset. Once OVP is activated, output is continuously shut off as long as the input power is supplied. Output voltage setting Turn off power and ensure supplied voltage stays within tolerable limits (100240VAC) and wait a few minutes before powering up again. After reset, the output voltage might be abnormal, so it should be confirmed and adjusted as needed. Adjust DC voltage out put by using Output Adjustment If this is the case, OVP will be activated, again. Potentiometer located next to the CN501 connector. CW = increase, CCW = decrease. Use in the following range: Remote voltage adjustment Within the rated output voltage ±10% at the output terminal (For LFS50A5, it a variable range of 4.5 to 6V.) Do not exceed the maximum output power and rated output current. This unit comes with an external voltage adjustment Slowly turn the potentiometer, not to exceed the rated voltage. function. Voltage can be adjusted by adding a remote potentiometer externally from the 56 pins of the CN501 connector. Adjust the integral potentiometer next to the CN501 connector to be fully CCW(counterclockwise) Inrush current SLOWLY turn the remote potentiometer, not to exceed the rated range. This unit comes with an integral inrush current limiting circuit. Rapid change like with switch will damage unit. Since SCR is used to prevent inrush current, the inrush current limiting circuit may have been released if the power Use twisted pair wires installed in parallel with load wire as shown below, to minimize external noise influence. is turned on again in a short time. Be sure to wait enough time before powering up again. 22 23 Proper selection of component providing power (contactor, fuse, circuit breaker, etc ) to this unit requires ratings compatible with AC IN 100V : 20A / ACIN 200V : 40A (Ta=25 Cold Start) due to internal SCR circuitry 24 Overcurrent protection (OCP) Volume Resistance: 5V, 12V, 15V 24V, 30V, 48V 5kΩ 10kΩ When it exceeds 110% of the rated output current, OCP shuts off the output. If no External Voltage Adjustment will be used, Turn off power and remove fault and wait a few minutes please retain CN501 jumper connector as shown : before powering up again. Avoid operation in the over current state longer than 10 seconds or damage or insulation failure may occur. 26 Connector (CN501) Remote Voltage Adjustment

2.Functions 27 Remote sensing 29 Series operation This unit comes with an integral remote sensing function. This Daitron power supply unit is configurable in series Please note that the maximum allowable voltage drop with another Daitron power supply (if it too is configurable from Load to CN terminal is 0.3V. Keep the power in Series) in order to increase DC voltage or to provide supply terminal voltage within the rated range. both and DC voltage. Please twisted pair wires installed in parallel with load In these configurations the MAXIMUM current delivered to wire as shown below. the Load is limited to the maximum allowable from the power supply with the lowest current rating. To increase VDC (PS1 PS2) see configuration (1) below. Example: If PS1 and PS2 are both 12VDC/30W each, then configuration (1) will provide 24VDC/30W To provide both and DC voltage to a load see configuration (2) below. Example: If PS1 and PS2 are both 12VDC/30W each, then configuration (2) will provide 12VDC to Load1 and 12VDC to Load2, with a maximum total wattage of 30W for both loads combined. If no Remote Sensing will be used, please retain CN501 jumper connector as shown: PS1 PS2 Load PS1 PS2 Load Load (1) (2) 210 Parallel operation This power supply can not configured in parallel with another power supply. 28 Remote ON/OFF circuit This unit comes with an integral on/off circuit, see wiring diagram below. Unit DC output is disabled when control voltage is applied to RC terminal in reference to V terminal. If SW is open or control voltage E is: 0 < E < 4.5V then unit output is enabled. If SW is closed and control voltage E is: 4.5VDC < E < 6.5VDC then output is disabled, and no need for current limiting resistor R. If SW is closed and control voltage E is: 6.5VDC < E < 24.5VDC, then current limiting resistor R must be = (E (1.1 1000x0.005))/0.005. For example if E = 24VDC, R = (24(1.15))/0.005 = 3.5kΩ

2.Functions 211 Ripple Maximum ripple voltage is measured using JEITA measurement method prescribed in RC9131C. If ripple noise becomes excessive due to line length, connect an electrolytic capacitor(47μf) and film capacitor (0.1μF) at load side as shown. The maximum ripple voltage in the standard specification is a value measured using the specified measuring circuit in the anechoic chamber under the JEITA measuring method (See the drawing). When the load line is long, the ripple on the load edge may become large unless a capacitor, such as an electrolytic capacitor or a film capacitor is connected. The output ripple cannot be measured accurately if the ground lead of the oscilloscope 1:1 Differential probe is Oscilloscope Measuring Ripple

Load(%) Load(%) 3. Mounting 31 Mounting direction 33 Mounting method (A) (B) Terminal Block (C) (D) Recommended tightening torque for M3 power supply mounting screws: 0.54Nm The LFS series cooling method is by convection, please mount with this consideration in mind. Terminal Block Terminal Block Terminal Block 32 Output derating Mounting direction (A), (B), (C), (D) By derating the output power (loading rate), this product can be used in a wide temperature range. LFS50A5 (C), (D) 100 80 60 (A) 40 20 0 10 0 10 20 30 40 50 60 70 Ambient Temperature ( ) (B) LFS50A12, 15, 24, 30, 48 (A),(B),(C),(D) 100 80 60 40 20 0 10 0 10 20 30 40 50 60 70 Ambient Temperature ( )

4.Connections Using twisted pairs for the output load wire, remote control wire, remote sensing wire, and external voltage adjustment wire and routing them separately from the input wire is ideal to minimize noise interference. For improved noise filtering, add lower value of electrolytic capacitor(section 211, 47μ F). Attaching a small volume electrolytic capacitor to the load end is also effective to eliminate noise. Minimize length of output load wiring. For safety and noise prevention, connect the FG terminal with the earth ground of the system using the power supply using minimal length possible. There is a possibility for an electric shock Recommended tightening torque for M3.5 I/O terminal screws: 1.03Nm Shut off the power, and carefully make connections for the remote sensing function or external voltage adjustment function. Incorrect wiring or poor connection could cause malfunction. 5.Troubleshooting Confirm input AC voltage to be within spec of 100240VAC/5060Hz. Confirm all input and output are wired correctly. Check if the wire material is not too thin. Check the output adjustment potentiometer. Sometimes OVP function turns off the output power when the potentiometer is adjusted too high. Please note that an excessive capacitive load can create over current situation. Confirm remote on/off is getting the appropriate voltage for desired operation. Before suspecting a failure. Check if the rated input voltage is connected. Check if the input/output wiring is appropriate. Check if a largecapacity capacitor is not connected to the load side. Check if the remote control is not active. Confirm the accessory connector for CN501 is connected. The accessory connector is required if the remote sensing function is not used. 6. Warranty The warranty is valid one year from the date of the delivery, except for the following cases. (1) Repair is provided at a cost for the following cases even during the valid warranty period. Failures or damage caused by incorrect use or unauthorized repair of the product Failures or damage caused by transport after delivery. Failures or damage caused by a fire, earthquake, wind and water, and other natural disasters, or abnormal voltage. Failures caused by other devices connected to the product. (2) For the use in special environments, such as salty, acid, alkaline, dusty, or corrosive environment, please contact us in advance.