SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

Similar documents
Digital Grid Products At a Glance Protection, Substation Automation, Power Quality

SICAM RTUs Ready for the Future

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities.

Compact Telecontrol System TM 1703 mic. SICAM 1703 flexible for all applications. Answers for energy.

Easily configurable HMI system for power automation siemens.com/sicam

SICAM AK 3. Flexible automation for all applications. Automation, telecontrol and communication for large data volume.

Products for digital substations SIPROTEC 6MU805. Merging Unit for conventional instrument transformer. Integrated PRP, HSR. siemens.

Automation Unit TM 1703 ACP. SICAM 1703 flexible for all applications. Answers for energy.

SIPROTEC 5 Protection, automation, and monitoring

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

SIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations.

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

Answers for energy. SIPROTEC 5 the new benchmark for protection, automation, and monitoring of transmission grids

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

SIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2.

Make the sun your energy source. SOLAR

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Perfect protection smallest space

Change setting groups via CFC.

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Bilfinger Mauell GmbH. smartrtu ME 4012 PA-N

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

SINAMICS DCM Cabinet. DC drive converter cabinets for fast and simple system integration. siemens.com/sinamics. Answers for industry.

iologik 4000 Series (M) Modules

SICAM Products and Solutions for Energy Automation

WP-Line 351 MK ll Combi I/O. control systems. Optimized I/O Combi module. 2 serial COM-ports

SIMATIC ET 200SP and ET 200MP

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

S800 I/O ABB Automation

AI561 Analog Input Module

AIAS. Technical description

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Siprotec 7ST61 / 7ST63

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display

siemens.com/energy/transformers FITformer REG The adaptable distribution transformer Answers for energy.

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

AC500-eCo: your PLC from ABB Unique scalable concept, optimal costs... Change for more!

It s fun to save. micromaster

Product type designation. General information. Supply voltage. Input current

Modular Two-Wire Telecontrol System

Extension of BI/BO for busbar protection SIPROTEC 7SS85

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current

WAGO Energy Data Management Efficiency Is That Easy!

WP3x00 MK ll Controller. control systems. All control functions are integrated. Integrated realtime grid measurement

reflex accessories electronic modules The intelligent connection to your control room

General information. Supply voltage

THE SOLUTION. MFW product family DATASHEET. MFW - Modular radio telecontrol system. A system from the. INFOwww.ees-online.de

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

SICAM DC - A new Generation of Smart Meter Data Concentrator Answers for infrastructure and cities.

Voltage Transducer UMT516 / MT516

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

DI572 Digital Input Module

General information. Display. Supply voltage. Input current

DI561 Digital Input Module

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

High impedance protection relay

Miniature Circuit Breakers for Railway Applications

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Telecontrol and Automation Systems

Process displays For current and voltage

General information. Display. Supply voltage. Input current

AO561 Analog Output Module

Time Counters mini "h", DC Version

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

Faults on the system Proximity switch connection technology:

General information. Display. Supply voltage

SWT 3000 Teleprotection siemens.com

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

Product type designation. General information. Supply voltage

Distributed Control I/O System ADAM-8000 Series

750 XTR Series TAKING IT TO THE EXTREME THE STANDARD FOR 750 XTR

More Precision. optoncdt // Laser displacement sensors (triangulation)

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

Compact Speed Monitoring and Overspeed Protection System

SIPROTEC 5 Application Note

Sigbert Reimann, Remote Control Forum, Datum 9. October 2013 RTU - Review and News. ABB Network Management Forum December 10, 2013 Slide 1

Company main topic [ Product ] TracFeed DCP2. English. Multifunctional Device for Control and Protection in DC switchgear.

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Displays Transducers. Displays and transducers

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Overvoltage Protection Devices

Transcription:

SICAM A8000 Series Operation, telecontrol, and automation in the smallest spaces siemens.com/sicam-a8000

4 Applications 5 Scalability in the application 6 Highlights at a glance 8 The entire product family 9 Compact solution 10 Power supply 11 Processor modules 13 Expansion modules 20 Mounting and parameterization 2

One for all: SICAM A8000 series The SICAM A8000 series is a new modular device range for telecontrol and automation applications. The most important features being: Rough ambient conditions Space-saving design Automation High electric strength Long product lifecycle Integrated communication Cyber Security Scalability 3

Wherever energy flows: Universal platform allows versatile use The SICAM A8000 device range has been designed for many different tasks, from simple to complex. Always adapted to the actual requirements, it is suitable for use along the entire energy supply chain. Hydroelectric power stations Railway power supply Solar and wind farms Transformer substations Distribution and secondary substations Industrial applications 4

Module by module: Precisely tailored to the application Individual tasks and application scenarios require modules that can be freely combined in nearly any way. Thanks to the different performance levels of the processor modules and the universal expansion modules, the SICAM A8000 series is nearly continuously scalable and can be expanded at any time. Example 1: High performance and many interfaces for complex tasks Automation tasks in power distribution and transmission, micro-grids Control functions in hydroelectric power stations, including the turbines themselves Control and communication in railway power supply As a communication gateway for various networks and protocols Example 2: Everything in view with the compact solution on site For use in distribution automation Optimized for use in MV switchgear Load-flow control available Example 3: Space-saving design with no display and a slim CP module Grid connection for solar and wind farms Control and monitoring of electricity and gas distribution stations Simple gateway function 5

Great benefits right from the factory: Well-designed for practical use 6

1. 2. 3. 4. 5. 6. 7. 8. 9. Platform modularity for versatile application options and reduced inventory Extended temperature range of -40 C to +70 C for rough ambient conditions Highest EMC stability up to 5 kv (IEC 60255) for direct use in substations Integrated short-circuit indicator functionality for use in cable network monitoring Use of international standards such as IEC 61850 for high investment security Integrated crypto chip and IPSec encryption to fulfill the high cyber security requirements Multitude of interfaces and integrated GPRS module for simple adaptation to existing communication infrastructures Integrated web parameterization tool for simple engineering Plug-and-Play functionality of the modules for time and cost savings 7

A strong team: Equipped for any task Compact device Power supply modules Processor modules Expansion modules The SICAM A8000 series consists of a combination of modules for power supply, processor, and expansions and is used for various tasks such as operation, telecontrol, automation, and communication. The SICAM A8000 CP-8000 compact device combines a power supply, display with function keys, and binary inputs and outputs. 8

Compact device CP-8000 Size (L x H x D) Temperature range Interfaces Memory 128 x 124 x 123 mm -40 C to +70 C 2 x Ethernet LAN 1 x RS 232 1 x RS 485 (galvanically isolated) SD card Data points 20,000 Special features Integrated power supply 12 DI, 8 DO integrated, max. 116 I/O (max. 6 expansion modules) Integrated function keys and display 9

Power supply PS-8620 and PS-8622 Operating voltage Output voltage 1 Output current 1 Output voltage 2 Output current 2 PS-8620: DC 18 78 V incl. tolerance PS-8622: DC 82.5 286 V incl. tolerance U out1 DC 5.15 V ±2% static ±3% dynamic 0 A 1.8 A U out2 DC 28.0 V ±10% static ±3% dynamic 0 A 0.43 A 10

Processor module CP-8021 Size (L x H x D) Temperature range Interfaces Memory 30 x 132 x 124 mm -40 C to +70 C 2 x RJ45 (Ethernet) 1 x RS 232 (RJ45) 1 x RS 485 (spring-loaded terminals, 8-pole plug) SD card up to 2 GB Data points 20,000 Distributed archive Available 11

Processor module CP-8022 Size (L x H x D) Temperature range Interfaces Memory 30 x 132 x 124 mm -40 C to +70 C 2 x RJ45 (Ethernet) 1 x RS 232 (RJ45) 1 x RS 485 (spring-loaded terminals, 8-pole plug) 1 x RS 232/485 (selectable) 1 x GPRS SD card up to 2 GB Data points 20,000 Distributed archive Available 12

Digital input modules DI-8110/11/12/13 16 binary inputs 2 groups with 8 inputs each DI-8110 DI-8111 DI-8112 DI-8113 Rated voltage DC 24 V DC 48/60 V DC 110 V DC 220 V Max. operating voltage DC 31.2 V DC 78 V DC 143 V DC 253 V Current consumption < 5 ma < 3 ma < 1.5 ma < 1 ma 13

Digital output module DO-8212 8 binary outputs (relay) 4 groups with 2 outputs each; galvan. isolated Rated voltage DC 24/48/60/110/220 V; AC 110/230 V Max. continuous current 8 outputs, each max. 3 A (5 A/1 minute) Switching capacity Direct voltage Min. 50 mw at DC 5 V Alternating voltage Max. 1,250 VA; 5 A/ V 250 AC, resistive load Max. 500 VA; 2 A/ V 250 AC, cosφ = 0.4 14

Analog input module AI-8320 AI-8320 4 analog inputs 4 groups with 1 output each; galvan. isolated Measurement range Current measurement Voltage measurement -20...0...+20 ma -10...0...+10 V Resolution 0.004% relative to the measuring range value Accuracy 0.15% at 25 C 15

Analog input module AI-8510 Inputs for measurement currents Input voltage at I N 225 mv as per IEC 60044-8 Max. measurement 200% I current Rated frequency 45...65 Hz Resolution 16 bit Sampling 20 values per system period Inputs for measurement voltage Input voltage 100/ 3 VAC, 230 VAC, 400/ 3 VAC (parameterizable) Max. measurement voltage Rated frequency Resolution Sampling Intrinsic consumption 150% U 45...65 Hz 16 bit 20 values per system period < 0.3 VA < 0.02 VA at U=230 V at U=110 V/ 3 16

Analog input module AI-8511 Inputs for measurement currents Input voltage at I N 225 mv as per IEC 60044-8 Max. measurement 200% I current Rated frequency 45...65 Hz Resolution 16 bit Sampling 20 values per system period Internal impedance 22 kω Inputs for measurement voltage Input voltage 3.25/ 3 VAC Max. measurement voltage Rated frequency Resolution Sampling Internal impedance 150% U 45...65 Hz 16 bit 20 values per system period 22 kω 17

Current transformer adapter module CM-8820 Inputs for measurement currents Rated current I N Max. measurement current Rated frequency 1 A/5 A (parameterizable) 200% I 45...65 Hz Intrinsic consumption Thermal withstand capability < 0.1 W < 0.3 W 10 A 100 A at I =1 A at I =5 A continuous 1 s Outputs for measurement currents Rated voltage at I N Max. voltage Rated frequency 225 mv as per IEC 60044-8 450 mv 45...65 Hz 18

Analog output module AO-8380 4 analog outputs Output current Output voltage Accuracy All outputs galvanically isolated -20 0 +20 ma at max. 500 W -10 0 +10 ma at max. 1 kw -20 0 +20 V at min. 1 kw 0.3% at +25 C 0.4% at 0 +50 C 0.7% at -20 +70 C 0.8% at -40 +70 C 19

Advantages tested in practise: Mounting and commissioning made easy Easy mounting Compact DIN rail mounting Detection of the plugged modules during startup Individual combination of modules Consistent bus for I/O modules Convenient engineering tools SICAM WEB SICAM TOOLBOOX II 20

Changes and errors reserved. The information provided in this document contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. The following applies to all products that include OpenSSL IT security functions: This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (www.openssl.org). This product includes cryptographic software written by Eric Young (eay@cryptsoft.com). Publisher Siemens AG 2016 Energy Management Division Freyeslebenstraße 1 91058 Erlangen, Germany www.siemens.com/sicam If you would like additional information, please contact our Customer Support Center. Phone: +49 180 524 70 00 Fax: +49 180 524 24 71 (charges depend on your provider) E-mail: support.energy@siemens.com Order no.: EMDG-B10037-00-7600 SICAM A8000 booklet Printed in Germany Dispo: 06200 EC 06116 WS 04163.0 04.2016, Siemens AG