MANUAL TV-100 TV-100

Similar documents
Vibration Meter Instruction Manual

Vibration Tester. Test and Measurement Instruments C.C.

GAOTek Vibration Meter with 2 Channel (High-Quality Accelerometer)

INSTRUCTION MANUAL. Portable Vibrometer: VM-3024S/H IMV CORPORATION

Heavy Duty Vibration Meter

Model No INSTRUCTION MANUAL. Manual should be read prior to operation!

Pocket type SOUND LEVEL METER Model : SL-4030

ST-140 Vibration Meter ST-140D Datalogging Vibration Meter User s Manual

User's Guide. Vibration Meter and Laser Combination Tachometer Model

Self-leveling Laser Marker (4V1HXL)

Heavy Duty Vibration Meter

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

Universal AC Power Source + AC Power Analyzer

VIBRATION METER Model : VB-8213

VB Model. Instruction Manual. Vibration Meter. reedinstruments. www. com

Bearing (Shock Pulse) Condition Analyzer -110

USER MANUAL. IST channel speed calibrator

MANUAL SURFACE ROUGHNESS TESTER TR-200 PARTNERS IN PRECISION

One (1) acoustic and three (3) seismic channels. Three (3) component velocity output. All units are interchangeable with accuracy within two percent.

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

Portable vibration calibrator Model 28959G

107VF Vibration Analyzer User s Manual

Shore D Hardness Tester TH210. Instruction Manual. TIME GROUP INC. Beijing Time High Technology Ltd

AGATE TECHNOLOGY AT-2030 OPERATORS MANUAL

RA3211 PON optical power meter

Vibration Meter and Laser Combination Tachometer

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

SRT5000 Surface Roughness Tester. Instruction Manual

Pen Vibration Meter. User's Guide. Model VB Washington Street Melrose, MA Phone Toll Free

Compliance with API Standard 670 the PRO Product Standard for Proximity Probes

MachineryMate 200 operating guide Handheld vibration meter

ELECTROSTATIC FIELDMETER

VIBROTEST 80 & VIBROPORT 80 The Allrounders

N5 Temperature Monitor Starter Guide

ReferenceMate handheld shaker Applications and specifications

HS-620/630 Vibration Meter Kit Operating Manual

VIBRATION METERS VX-54WH. Hand-Arm Vibration VX-54WB. Whole-Body Vibration VX-54WS. Habitability on Ships. 3-Axis Vibration Meter VM-54

Operation Manual for OLS-1315 Optical Light Source

INSTRUCTION MANUAL. Portable Vibrometer: VM-7024H IMV CORPORATION

Operation Manual. Digital Vibration Tester. Model No. DVM-1000

CONTENTS Introduction 4 DTR overview 4 probes 5 functions 5 display 5 DTR operation 6 switching the DTR on or off 6 changing label 6 displaying

MetaDolce MD3600 IP65 Multi-Data Capture Tablet Quick Manual. 1. Keys and Connectors

User's Guide. Model High Precision Quad Output DC Power Supply

SADT ULTRASONIC THICKNESS GAUGE SA40

Manual Vibration Meter PCE-VT PCE Instruments

ULTRASONIC. Proximity Sensors. Series UX micro. Key-Features:

Model No. SRG 2000 INSTRUCTION MANUAL. Manual should be read prior to operation!

PTR. printing temperature recorder. User Manual. order code:

Temperature logger with internal sensor Instruction manual

Vibracord FX. The perfect equipment for your. measurement. Vibracord FX in aluminum case. Frequency response: Hz Hz

TV Field Meter. User s Guide UG-TVMETER-EN V1.1

NIR Moisture Analyzer KB-30

Vibracord FX. The perfect equipment for your. measurement. Vibracord FX in aluminum case. Frequency response: Hz Hz

Richter Optica. Instructions for Model: MDS2 Middle School Microscope

ISH-DSA DIGITAL SHORE DUROMETER OPERATION MANUAL

OPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD

DICKSON FH320/325 & FT300/325 DICKSON. Temperature/Humidity Recorder. Specifications. Applications & Product. Product. Contents: Getting Started

ED-1100 PORTABLE VARIABLE EDDY CURRENT INSTRUMENT

HCC-CW-201A. CWDM Analyzer. Operation Guide

MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC

Vibration Transducer SLD121 A

9200, Seismoprobe* Velocity Transducers

Operating Manual. AdirPro HV8RL Red Beam Horizontal/Vertical Laser level

High Precision Quad Output DC Power Supply

Electronic SD1, AS 8, ASR 14, ASR 20

MTN/VM220. Instruction Manual. High performance Vibration Meter. We reserve the right to alter specifications without prior notice.

DHT-100 Instruction Manual

True RMS AC Voltage/Current Datalogger

Laser Roughness Tester TRL400 Instruction Manual

4-Channel Vibration Datalogger

Model : LUV-300 Please read this manual carefully before using the instrument Labnics Equipment

TES-1353S INSTRUCTION MANUAL

FIBER. WP-TEST-FIBER-400 Optical Power Meter Owner s Manual

Trend-1 Vibration Data Logger. User Manual

Phone Setup. Phone Hardware Installation. Install the Phone Battery. Phone Hardware Installation, on page 1 Phone Configuration Tasks, on page 15

BILL COUNTER OPERATION MANUAL PRODUCT #700012

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

X-Beam Waterproof Action Camera Light USER GUIDE

CONTENTS. 1. Preface Features Technical Specifications Application of Dummy Plate Usage of Connector & Roller...

Surface Roughness Tester. Instruction Manual.

Soundance Bluetooth Speaker User Manual Model SDY019

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

Vibration Meter SD Card real-time datalogger

Manual Vibration Analyser PCE-VT 1000

The Care And Cleaning Of Your Manatee County Schools ibook

TITLE PAGE I. Safety Information II. General Description III. Specifications IV. Controls V. Calibration Procedures VI. Measurement Preparation

SVAN 974. Vibration ANALYSER USER S MANUAL

RESS. Manual. Rotary-Ball-Camera Pro. The Producer. Visual Inspection Sweep Instruments Measuring Instruments

THREE-AXIS HALL MAGNETOMETER THM1176 TECHNICAL SPECIFICATIONS

Richter Optica. Instructions for Model: HSX1 High School Microscope

This manual was downloaded on (0) TS8000. Firewire Option 8000/FA/00 HA Issue 1

Operation Voltage: V Working Current: <2.0mA. Standby Current: mA Sleeping Current:<25uA. Charging Current 100mA Standby Time: 90days

OPERATION & MAINTENANCE SPECIFICATIONS MANUAL 09 07

Eco D-ELS-4 Stereo Microscope. Instruction Manual

FG-3000R Digital Force Gauge Operation Manual

INSTRUCTION MANUAL CALIBRATION EXCITER VE Higashimotomachi, Kokubunji, Tokyo , Japan

Instruction Manual Ultrasonic Thickness gauge DC3020

MANUAL TR-200. Surface roughness tester

Operation Manual for OPM-1315 Optical Power Meter

Transcription:

MANUAL TV-100 TV-100

CONTENTS 1. GENERAL DESCIPTIONS 2 1.1 Range of applications 2 1.2 Basic working principle 2 1.3 configuration and meter component description 2 1.3.1 Basic configuration 2 1.3.2 Description of meter components 3 2. TECHNICAL SPECIFICATIONS 6 2.1 Performance parameters 6 2.2 Main functions 6 3. HOW TO USE THE METER 7 3.1 Keypad operation 7 3.1.1 Function of the keys 7 3.1.2 To test vibration displacement and print the tested result 8 3.2 Installation of Transducer 9 3.2.1 Installation principle 9 3.2.2 Install method 9 4 MAINTENANCE AND TROUBLESHOOTING 11 Manual TV-100 1

1. GENERAL DESCRIPTION 1.1 RANGE OF APPLICATIONS The vibration meter is designed to test conventional vibrations, especially the vibration test in rotating and reciprocating machines. It can be used not only to test the acceleration, velocity and displacement of vibration, but also to record and print out values. The technical specifications of the meter comply with the requirements of this vibration scale of the testing meter specified by ISO 2954 international standards. The meter is widely used in machinery, power, metallurgy, automobile and other industrial sectors. 1.2 BASIC WORKING PRINCIPLE The meter employs piezoelectric acceleration type transducers to convert vibration signals into electric signals. Then by analyzing and processing input signals, tested values are displayed or printed out. 1.3 BASIC CONFIGURATION AND METER COMPONENT DESCRIPTION 1.3.1 BASIC CONFIGURATION TV100 main body 1 Micro printer 1 Vibration testing transducer 1 Battery charger 1 Magnetic suction base 1 2 Manual TV-100

1.3.2 DESCRIPTION OF METER COMPONENTS A. Main body and micro printer (see Fig.1-1) Fig.1-1 part description of main body and printer 1. stop plate 2. transducer socket 3. battery charger socket 4. TV100 main body 5. printer paper holder 6. micro printer 7. display screen 8. keyboard 9. printer switch 10. power switch Manual TV-100 3

B. Transducer (see Fig.1-2) Fig.1-2 description of transducer components 1. position sleeve 2. protection sleeve 3. connection cord 4. stationary connector 5. cable port 6. housing 7. base 4 Manual TV-100

C. LCD screen (see Fig.1-3) Fig.1-3 (A) full screen display Fig.1-3 (B) partition areas of display functions 1. date indication 2. operation mode (only WAVE mode available for TV100) 3. limit indicator 4. testing parameters 5. data area 6. testing unit 7. range of frequency 8. low voltage indication 9. point and number indication (only point available for TV100) Manual TV-100 5

2. TECHNICAL SPECIFICATIONS 2.1 PERFORMANCE PARAMETERS 1. The testing range Acceleration: 0.1-199.9 m/s 2 (peak value) Velocity: 0.01-19.99 mm (effective value) Displacement: 0.001-1.999 mm (peak - peak value) 2. The frequency range Acceleration: 10Hz - 10KHz Velocity: 10Hz - 1KHz Displacement: 10-500 Hz 3. Tolerance: equal or smaller than ±5% ±2 digits 4. Operating ambient temperature: 0-45 deg. C 5. Power supply: nickel -- cadmium battery 4 1.25V 6. Overall dimensions: 270 86 47 (mm) 7. Weight: 650g 2.2 MAIN FUNCTIONS 1. Equipped with printer, measurement value can be printed. 2. Low voltage indication function. 3. Date setting function. 4. Memory function: It can store 10 measurement values. 6 Manual TV-100

3 HOW TO USE THE METER 3.1 KEYPAD OPERATION 3.1.1 FUNCTION OF THE KEYS The keypad of TV100 is shown as Fig.3-1. There are six keys: RUN/STOP, AVD, UP, DOWN, DATE and PRINT key. Fig.3-1 RUN/STOP key: Measure and hold. Press RUN/STOP key once to measure. The tested value will be displayed on the screen. At this time, other keys (such as AVD, DATE, etc.) are disabled. Press RUN/STOP key again to enter waiting status. The last tested value is displayed. And the last tested value is stored automatically. Two seconds later, 1 is added to "point number". TV100 has 10 store units. Every store unit has a point number (0, 1 8, 9 ) to indicate its series number. Each store unit can store 1 tested value. AVD key: DATE key: Switch among three measuring modes. Press AVD key, A (Acceleration), V (Velocity) and D (Displacement) will be chosen and displayed in turn. A (Acceleration) mode is the default setting of TV100. Switch among year, month and date settings. Fig.3-2 UP, DOWN key: PRINT key: 1. Adjust year, month or date settings with DATE key. 2. Adjust point number of store unit. print tested values in the store units. For example: If the point number displayed is 5, then tested values in store unit 0,1,2,3,4 and 5 will be printed. Note: in Date state, when press PRINT key, the printer will feed in paper. Manual TV-100 7

3.1.2 EXAMPLE: TO TEST VIBRATION DISPLACEMENT AND PRINT THE TESTED RESULT 1) Install the transducer properly. 2) Switch on the power switch. The information as shown in Fig.3-3 will be displayed after the full LCD screen ( Fig.1-3 (A)) is displayed. Fig.3-3 3) Press AVD key until displacement mode is chosen, as shown in Fig.3-4. Fig.3-4 4) Press RUN/STOP key to test. The tested value will be displayed on the screen, as shown in Fig.3-5. Fig.3-5 5) Press RUN/STOP key again to enter waiting status. The last tested value is displayed. And the last tested value is stored in current point number (say point 0 in this example). Two seconds later, 1 is added to "point number", and it displays the value in the new point number (say point 1 in this example), as shown in Fig.3-6. 8 Manual TV-100

Fig.3-6 6) To go on testing, repeat step 4) and 5). 7) Switch on the printer and prepare to print. 8) Press PRINT key. Tested values in current point number and in previous point numbers will all be printed. 9) If no other test is needed, switch off the TV100. 3.2 INSTALLATION OF TRANSDUCER 3.2.1 INSTALLATION PRINCIPLE - The testing position should show the vibration characters of the object to be tested. - The main axis of the transducers should be consistent with the direction of he object to be tested. - The transducers should be in close contact with the object to be tested. 3.2.2 INSTALL METHOD 1) Installed with bolt Application range: Usage: Screw eye has no influence on the running of the object being tested. Drill a screw eye 5mm deep in the object being tested. Connect the transducer to the object by bolts (see Fig.3-7). And this is the method that the frequency response is best. Fig. 3-7 Manual TV-100 9

2) Installed with magnetic base Application range: Magnetic, flat surface, roughness less than Ra1.6, acceleration less than 20 m/s2. Usage: Before usage, take off the iron wafer and rubber wafer under magnetic base (ensure enough suction), and then screw up the magnetic base on transducer (see Fig. 3-8). After usage, put back the iron wafer and rubber wafer to maintain the magnetism. Fig. 3-8 3) Installed with probe Applications range: Fig. 3-9 Usage: Frequency is less than 1KHz; vibration energy is not too small. Connect the needle to the transducer directly by using probe groupware (see Fig. 3-9) 10 Manual TV-100

4 MAINTENANCE AND TROUBLESHOOTING - Strictly avoid collision, heavy dust, dampness, strong magnetic field, oil, grease and dirt. - Twinkling of BETT in the LCD indicates low-battery. Charge the TV100 for 8 hours. It is better to switch off the TV100 while charging. - Don't use alcohol or diluent to clean TV100. They will erode TV100, especially the display window of TV100. A little water can be used to clean it. - Don't plug or unplug transducer or printer while TV100 is power on. - Don't switch on TV100 right after switch off. Please leave 5 seconds to switch on again. - If the printer doesn't work well, switch off the power and switch it on 30 seconds later. - If the TV100 is down, switch off the power and switch it on 5 seconds later. - If the tested value is beyond the testing range, refer to 2.1, the up limit value 1999 will be displayed in LCD and the LIMIT indicator will twinkle till the tested value is within the testing range. - The vibration meter is a high-precision instrument and is subject to environment influence. So it should be calibrated periodically. Manual TV-100 11