Metro-Optical Transport Access Nodes

Similar documents
Enterprise Session Border Router, IAD

Enterprise Session Border Router

SIP 3CX Based Private Branch Exchange

Multi-Port T1/E1/PRI VoIP Enterprise Gateway Router

SmartNode 4830 DSL Series Analog VoIP Integrated Access Device Quick Start Guide

T1/E1 Channelized Gigabit Router

Leased-Line Extenders over IP

Single/Dual-Port ISDN BRI VoIP Terminal Adapter

Optical Multiplexer. Quick Start Guide

G.SHDSL IAD. iprocketlink Model Quick Start Guide

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

USER MANUAL MODEL CopperLINK Ethernet Extender. This is a Class A device and is not intended for use in a residential environment.

Ethernet Extender. EnviroNET 2100 Series. Quick Start Guide

VPN Routers. OnSite 2800 Series. Quick Start Guide

G.SHDSL NTU with Fixed Serial Interfaces

G.SHDSL NTU DECEMBER 2006 LB510A

Multi-Port T1/E1/PRI Enterprise VoIP Media Gateway

Multiport Analog VoIP Router

EFM Router. OnSite Model Quick Start Guide

USER MANUAL MODEL CopperLINK High Speed Ethernet Extenders

Multi-Port T1/E1/PRI VoIP Enterprise Session Border Router

OpenScape Business Appliance

Preparing to Install the Cisco AS5350XM Universal Gateway

OnSite 1052 &1063 Series Metro-Optical Transport Access Nodes

Installing and Managing the Switch

SmartNode 1000 and 2000 Series

NI PXI-1042 Series Power Supply Shuttle

OnSite Model 3088A/I G.SHDSL.bis EFM CPE

Installing the Cisco ATA

ADSL2+ Multiport ISDN VoIP IAD

Serial G.SHDSL Bridge/Router

EOS-6000 Series Optical A/B Switch User Manual DC Version

SmartNode 1000 and 2000 Series

OnSite 1052 &1063 Series Metro-Optical Transport Access Nodes

PacketBand TDM-4 Quickstart Guide V3.2

CPCI System Subrack 1 U

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

Installing the Cisco Unified Videoconferencing 3545 MCU

ewon Flexy PSTN Extension Card FLA P3501 Installation Guide

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Installing the Cisco VG224 Voice Gateway

ewon Flexy PSTN Extension Card FLA 3501

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

Preparing to Install the VG248

3/4 U CPCI Serial Case System

Installation Job Aid for Ethernet Routing Switch 3600 Series

LVN5200A-R2, rev. 1, Hardware Installation Guide

Manual Version: V1.00. Video Decoder Quick Guide

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

USER MANUAL. MODEL 56X Series 564, 566, 568, 562. Hub Surge Protectors

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Installing the Cisco MDS 9020 Fabric Switch

Dell OptiPlex All-in-One. Stand Installation Guide

Diamond Edge Model 3224 G.SHDSL IpDSLAM

Simple Logger II Series

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

UTAH-100/XHDA SERIES

Agilent OBSAI Protocol Tester

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

P344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual. January Rev 1.31

iconverter 2-Module Power Chassis

InnoMedia Business VoIP ATA Models

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

Quick Start Guide. C-100 Series Switches

Model 3088/I RocketLink-G G.SHDSL NTU

3+1 U CPCI Serial System

Controller Specifications

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

MODEL 805 USER MANUAL

SmartNode 2290 Series Leased-Line Extenders over IP

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

DS-1H05 Ethernet-over-Coax Extender. User Manual

TippingPoint Zero Power High Availability Installation Guide

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

CMSA-100 Manual. Cinema Media Server Automation

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Intel Server Board S2600BP Intel Compute Module HNS2600BP Product Family

CPCI System Subrack 3 U

USER MANUAL MODEL 503P & 503PC. Parallel Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

TL-PA4010 AV600 Powerline Adapter

TRC-190 User s Manual

TRC-190 User s Manual

USER MANUAL MODEL 536S Token Ring (STP) Surge Protector. SALES OFFICE (301) TECHNICAL SUPPORT (301)

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

VME64x System Subrack 8 U

Mediatrix 4400 Digital Gateway VoIP Gateway with the PSTN

±15 V Current-Limited Power Supply

Cisco SRP500 Series Services Ready Platforms (SRP540 Models)

Rack Mount Power Supplies

USER MANUAL MODELS 2156 & CopperLink Ethernet Extenders SALES OFFICE (301) TECHNICAL SUPPORT (301)

BCM2 Series Branch Circuit Monitors Quick Setup Guide

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Series 8000 RF Signal Switch Solution

RDX QuikStation System Components

Transcription:

OnSite 1052 & 1063 Series Metro-Optical Transport Access Nodes Quick Start Guide Important This is a Class A device and isnot intended for use in a residential environment. Part Number: 07MOS10xx-QS, Rev. C Revised: February 20, 2012 Sales Office: +1 (301) 975-1000 Technical Support: +1 (301) 975-1007 E-mail: support@patton.com WWW: www.patton.com

WARNING Do not open the device when the power cord is connected. For systems without a power switch and without an external power adapter, line voltages are present within the device when the power cord is connected. For devices with an external power adapter, the power adapter shall be a listed Limited Power Source The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker in compliance with local regulatory requirements. For AC powered devices, ensure that the power cable used meets all applicable standards for the country in which it is to be installed. For AC powered devices which have 3 conductor power plugs (L1, L2 & GND or Hot, Neutral & Safety/Protective Ground), the wall outlet (or socket) must have an earth ground. For DC powered devices, ensure that the interconnecting cables are rated for proper voltage, current, anticipated temperature, flammability, and mechanical serviceability. WAN, LAN & PSTN ports (connections) may have hazardous voltages present regardless of whether the device is powered ON or OFF. PSTN relates to interfaces such as telephone lines, FXS, FXO, DSL, xdsl, T1, E1, ISDN, Voice, etc. These are known as hazardous network voltages and to avoid electric shock use caution when working near these ports. When disconnecting cables for these ports, detach the far end connection first. Do not work on the device or connect or disconnect cables during periods of lightning activity. This device contains no user serviceable parts. This device can only be repaired by qualified service personnel. WARNING WARNING If one has reason to open the chassis or case, then the precautions mentioned above shall be followed. This includes both the warnings relating to disconnection of the input power, and the warnings relating to the disconnection of WAN, LAN & PSTN ports. This device is NOT intended nor approved for connection to the PSTN. It is intended only for connection to customer premise equipment. WARNING 2 OnSite Series Quick Start Guide

CAUTION Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures. Do the following to prevent ESD: Always follow ESD prevention procedures when removing and replacing cards. Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground. To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis. 1.0 Unpacking and Installation 1. Check the contents of the shipping container and accessories box or bag against the content list and the packing slip. Verify that you received all listed equipment and inspect all items for shipping damage. 2. Unpack the OS-10 Series chassis and install it into a rack according to the instructions in the OnSite Series User Manual available online at www.patton.com/manuals/os10xx.pdf. 3. Verify that the site where you wish to install and operate the equipment conforms to the environmental requirements in the OnSite Series User Manual. 2.0 Powering Up the System If your OS-10 Series system was ordered for use with AC power, follow these steps: 1. Connect the enclosed AC power cable to the AC power receptacle on the rear side of the OS-10 Series chassis. 2. Connect the power cable plug to an AC power source with the following characteristics: 15 A at 120 VAC (60 Hz) or 10 A at 240 VAC (50 Hz) circuit with overcurrent protection. Refer to the OS-10 Series Installation and Operation Guide if your system was ordered for use with DC power ( 48 VDC nominal). When you first apply power to the system, the STAT (status) LED on the front panel becomes a solid amber light. This light indicates that the system is booting. The STAT LED becomes a solid green light when the system completes the boot process and is ready for management access and operation. OnSite Series Quick Start Guide 3

3.0 Accessing and Configuring the System To access the system management functions for the first time, your may use either the SERIAL or the Ethernet LAN management port. Refer to the Installation and Operation Guide for access through the SERIAL port. For first time access through the Ethernet LAN management port, follow these steps: 1. Connect a PC to the Ethernet LAN management port using the RJ-45 connector. 2. Configure the PC to connect to the OS-10 Series system using the factory default settings for the Ethernet LAN management port. Note By default, the IP address is set to 192.168.2.100. 3. Launch the Web browser of your choice, and type the default IP address of the system in the Address field of the browser. 4. Log in to the OS-10 Series system using the super user ID and password. Note The factory-assigned default password for the Super user is super (all lowercase letters). Once you gain access to the system using the default settings, change the IP settings for the LAN port for secure access to the system. 3.1 Changing the IP Settings for the LAN port To configure the Ethernet LAN management port settings, follow these steps: 1. Select the SYSTEM folder from the OnSight Device Manager (DM) web-based GUI navigation menu. 2. From the expanded SYSTEM folder, select Management Access, and from this folder select LAN. 3. On the Ethernet LAN Management Port page, type the new LAN IP Address. Note The Admin Status for the Ethernet LAN management port is always enabled. 4. Click on Apply. The new IP settings take effect once you click on the Apply button. This change in settings causes the loss of access connectivity to the system. You can regain access immediately by typing the new IP address of the LAN port in the Address field of the browser. (Make sure that you change your PC settings to allow connectivity to the OS-10 Series system over the same IP subnetwork.) You will need to save the system configuration to avoid losing the new IP settings after a subsequent reboot. Note The system uses the last saved configuration to restore system operation and traffic connectivity after the completion of the reboot. Any recent configuration data and connections not saved to the system configuration file are lost and need re-entry, if required. 4 OnSite Series Quick Start Guide

3.2 Saving the System Configuration To save the system configuration to the flash memory, follow these steps: 1. Select the SYSTEM folder from the OnSight DM web-based GUI navigation menu. 2. From the expanded SYSTEM folder, select the Actions folder. 3. From the expanded Actions folder, select Save Configuration. A warning window opens to alert you to the start of the save-configuration process. Click on OK to continue or Cancel to cancel the request. 4.0 Additional Information The system is now ready for operation using the OnSight DM web-based graphical user interface (GUI). You may now configure the system clock, timing mode and STM-1 interface settings for your intended application. For detailed instructions, refer to the OnSite Series User Manual and the OnSite Series Administrator s Reference Guide available online at www.patton.com/manuals/os10xx.pdf and www.patton.com/manuals/ OS10xx-arg.pdf. A.0 Customer and Technical Support Online support: www.patton.com E-mail support: support@patton.com answered within 1 business day Telephone support: Standard: +1 (301) 975-1007 (USA), Monday Friday: 8:00 am to 5:00 pm EST (1300 to 2200 UTC/GMT) Alternate: +41 (0)31 985 25 55 (Switzerland), Monday Friday: 8:00 am to 5:00 pm CET (0900 to 1800 UTC/GMT) Fax: +1 (253) 663-5693 (USA) or +41 (0)31 985 25 26 (Switzerland) OnSite Series Quick Start Guide 5

B.0 Compliance Information B.1 Compliance EMC Compliance: EN55022, Class A EN55024 Low-Voltage Directive (Safety Compliance): IEC/EN60950-1 PSTN: This device is not intended nor approved for connection to the PSTN. B.2 CE Declaration of Conformity Patton Electronics, Inc declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC relating to electromagnetic compatibility and Directive 2006/95/EC relating to electrical equipment designed for use within certain voltage limits. The Declaration of Conformity may be obtained from Patton Electronics, Inc at www.patton.com/certifications. The safety advice in the documentation accompanying this device shall be obeyed. The conformity to the above directive is indicated by CE mark on the device. B.3 Authorized European Representative D R M Green European Compliance Services Limited. Avalon House, Marcham Road Abingdon, Oxon OX14 1UD, UK 6 OnSite Series Quick Start Guide

Copyright statement Copyright 2012, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document. Trademarks statement The term OnSite is a trademark of Patton Electronics Company. All other trademarks presented in this document are the property of their respective owners. Warranty, Trademark, & Compliance Information For warranty, trademark and compliance information, refer to the OnSite Series User Manual located online at www.patton.com/manuals. In accordance with the requirements of council directive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling. OnSite Series Quick Start Guide 7

NOTES 8 OnSite Series Quick Start Guide