Analog Modules AS-i IP65, M12

Similar documents
Analog Modules AS-i, IP67, M12

Digital Modules AS-i, IP67, M12

Digital Modules AS-i in IP20, 22,5 mm

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i 3.0 motor module

PCB AS-i modules, board based solutions

AS-i Safety Output Module, IP20

AS-i 3.0 Motor modules

AS-i Safety Input Modules (M12), IP67

AS-i 3.0 motor modules

Active Distributors AS-i Safety, Active Distributors AS-i

AS-i Safety Analog Input Module, IP20

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Active Distributors ASi Safety, IP67

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Diagnostics (Logical)

Diagnostics (Logical) Diagnostics (Physical)

Installation Instructions Temperature transmitter TAA /00 06/2011

AS-Interface I/O Module

Cube67 - Modular I/O station

INTRODUCTION: AS-i slave modules are now available for MICROMASTER, MICROMASTER Vector, MICROMASTER Integrated & COMBIMASTER.

Universal Controller

GSV-1A4 M12/2 M12/2. Highlights

Super universal modules

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45

Product Overview. by Bihl+Wiedemann

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

AS-Interface INSTALLATION GUIDE, TIPS AND TRICKS

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

Diagnostics (Logical) Diagnostics (Physical)

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Thermal-Magnetic Circuit Breaker 2216-S

Cube20. Application-oriented. Installation-friendly. Efficient

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

MBM - Modular I/O system IP20

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

Immersion Temperature Sensors

Operating instructions. ProcessLine analogue module AC / / 2012

Resistance measuring module

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

Temperature Switches

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Process displays For current and voltage

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Overvoltage Protection

E-STOP relays, safety gate monitors

Expansion Module HZS 541-1S

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Module 18plus. Description. 18plus

Screw terminal panels, Relay output boards, connection cables

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

9926 Series Branch Rated Circuit Breakers AC Version

Sensor boxes SRBG Key features

SX5A AS-Interface(Communication Terminal and Repeater)

Temperature module. 4 inputs for thermocouples

E-STOP relays, safety gate monitors

C-DIAS Analogue Output Module CAO 081 for eight 10V DC outputs

EtherCAT Slave. EtherCAT Data Transition. EtherCAT Tool: TwinCAT. Taiwan Pulse Motion Co.,Ltd

DATA SHEET Selectable AC transducer, TAS-331DG

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

EXOcompact Third Generation Manual

SITOP in the SIMATIC Design

BOX TRANSDUCER SMALL SIZED AC TRANSDUCER 90 SERIES

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

SIMOCODE 3UF Motor Management and Control Devices

Switches and Indicators 84

Operating instructions Memory plug E /02 11/2011

Installation / Control / Monitoring Technique

PSC-AC. PSC AC-series W 1 to 3 Outputs. AC-DC Power supply. Input Voltage ranges. Single output ratings. 2-3 outputs ratings

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Communication & Networking

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

OPERATION MANUAL - DS-MOD-

Transcription:

Plug and Play as simply as digital AS-i I/O BWU1361 / BWU1362 / BWU1722 / BWU1853 / BWU1917 / BWU1363 / BWU2532 / BWU1359 / BW1360 / BWU1893 BWU1894 BWU1895 BWU1963 BWU1964 Housing, construction: IP65, M12 Housing 45 mm wide Inputs Outputs Input voltage Output voltage AS-i address 3 Art. no. analog analog (sensor supply) 1 (actuator supply) 2 2x 4... 20mA 0 out of AS-i 1 AB Slave BWU1893 2x 4... 20mA 0 out of AS-i 1 Single Slave BWU1894 2x 0... 10V 0 out of AS-i 1 AB Slave BWU1963 2x 0... 10V 0 out of AS-i 1 Single Slave BWU1964 2x Pt100 0 out of AS-i 1 AB Slave BWU1895 1x (4... 20mA / 1x (0... 20mA / out of AS-i out of AS-i 2-4 Single Slaves BWU1917 1x (4... 20mA / 1x (0... 20mA / out of AUX out of AUX 2-4 Single Slaves BWU1853 4x 4... 20mA 0 1 Single Slave BWU1359 90 mm wide 4x 0... 10V 0 1 Single Slave BWU1360 4x Pt100, 2/4 wire mode 0 out of AS-i 1 Single Slave BWU1363 4x Pt100, 2/3 wire mode 0 out of AS-i 1 Single Slave BWU2532 4x 0... 20mA out of AUX 1 Single Slave BWU1722 4x 0... 20mA 1 Single Slave BWU1361 4x 0... 10V 1 Single Slave BWU1362 1 Input voltage (sensor supply): inputs are supplied by AS-i or by AUX (auxiliary 24V power). If supplied by AS-i, inputs can neither be connected to earth nor to external potential. 2 Output voltage (actuator supply): outputs are supplied by AS-i or by AUX (auxiliary 24V power). If supplied by AS-i, inputs can neither be connected to earth nor to external potential. 3 AS-i address: AB Slave (max. 62 AB Slaves/AS-i network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/per AS-i network), mixed use allowed. www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 12.12.12 page 1

Article no. BWU1893 BWU1894 BWU1895 BWU1963 BWU1964 BWU1359 BWU1360 BWU1363 BWU2532 General data Device type Input Connection Periphery connection M12 plug AS-i connection via AS-i substructure module AS-i Profile S-7.A.9 S-7.3.D S-7.A.9 S-7.3.D S-7.3.E Slave-Type AB Slave (up to 62) Single Slave (up to 31) AB Slave (up to 62) Single Slave (up to 31) Required Master profile M4 M3 M4 M3 Since AS-i specification 3.0 2.1 3.0 2.1 Operating voltage AS-i voltage 30V DC Max. current < 200mA < 80mA < 200mA < 100mA < 80mA AUX Voltage 18.. 30V Max. current 500mA Input Resolution normal: 14 Bit, fast: 11Bit 14 Bit 11 or. 14 Bit 16 Bit (1 A) 16 Bit (1mV) 16 Bit (0,1 C) Range of value 4000... 20000 dez. / -2000... +850 0... 27648 dez. 1 0 dez. -12000... 13000 dez 0... 10000 dez. 4000... 20000 0... 27648 dez. 1 dez. 0... 10000 dez. -200 C... +85 0 C Internal resistance 82 130K 50 100K Max. input voltage 25V 25 Max. input current 40mA 40mA Power supply 24V out of AS-i 24V external or out of AS-i Power supply of max. 70mA max. 70mA max. 500mA out of external attached sensors 24V, max. 100mA out of AS-i Environment Applied standards EN 61 000-6-2 Housing housing for DIN-rail mounting EN 50 081-2 Operating temperature 0 C +70 C -20 C +70 C Storage temperature -20 C +85 C Protection category IP65 DIN 40 050 Voltage of insulation 500V Dimensions (W / H / D) 45 / 80 / 45 90 / 80 / 45 in mm 1 Siemens format 0 C +70 C page 2 Mannheim, 12.12.12 We reserve the right to change any data www.bihl-wiedemann.de

Article no. BWU1853 BWU1917 BWU1361, BWU1362 BWU1722 General data Device type In-/Output Output Connection Periphery connection AS-i connection AS-i M12 plug via AS-i substructure module Profile S-6.0.x S-7.3.6 Slave-Type 2, 3 o. 4 Single Slaves (up to 31) Single Slave (up to 31) Required Master profile M4 M3 Operating voltage Max. AS-i current AUX AS-i voltage 30V DC < 200mA < 100mA Voltage 18..30V 18..30V Max. AUX current 1A 500mA Input Resolution 16 Bit (1 A) or 16 Bit (1mV) Range of value 4000... 20000 dez. / 0... 10000 dez. Internal resistance 4-20mA: 50 0-10V: 100k Max. input voltage 25V Max. input current 40mA Power supply 24V external 24V out of AS-i Power supply of max. 1A in total max. 200mA in total attached sensors (sensors and actuators) (sensors and actuators) Ausgang Resolution 16 Bit (1 A) or 16 Bit (1mV) 16 Bit (1 A) 16 Bit (1mV) Range of value 4000... 20000 dez. / 0... 10000 dez. 0... 20000 dez. 0... 10000 dez. Resistance of actuators 0-10V: min. 3,3k 0-20mA: max. 600 max. 600 Max. output voltage 11,5V Max. output current 23mA Power supply 24V external 24V out of AS-i 24V external or out of AS-i Power supply of attached actuators Environment max. 1A in total (sensors and actuators) Applied standards EN 61 000-6-2 Housing Operating temperature Storage temperature Protection category DIN 40 050 Voltage of insulation max. 200mA in total (sensors and actuators) housing for DIN-rail mounting 0 C +70 C -20 C +85 C IP65 500V max. 1,1A in total EN 50 081-2 www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 12.12.12 page 3

Programming input Bit setting P0: BWU1893 BWU1894 BWU1895 BWU1963 BWU1964 Article number BWU1359 BWU1360 BWU1363 BWU2532 1 1 1 1 1: Bridge between Pin 3 and 4 active 0: Bridge between Pin 3 and 4 active 1: 50 Hz filter in A/D converter active 0: 60 Hz filter in A/D converter active P1: 1: 4000... 20000 dez. 0: 0... 27648 dez. (Siemens format) 1: 2 wire-mode 0: 4 wire-mode 1: 0... 10000 dez. 0: 0... 27648 dez. (Siemens format) P2: 1: normal 0: fast 1: -200 C... +850 C 0: -120 C... +130 C P3: 1: channel 2 on 0: channel 2 off 1: 2 wire-mode 0: 4 wire-mode 1: 2 wire-mode 0: 3 wire-mode 1 For peripheral fault setting see the table "Bit combinations P1 and P2 Bit combinations P1 and P2 BWU1359, BWU1360, BWU1363, BWU2532 Peripheral fault can be released through channel P1 P2 1 2 3 4 0 0 on off off off 0 1 on on off off 1 0 on on on off 1 1 on on on on page 4 Mannheim, 12.12.12 We reserve the right to change any data www.bihl-wiedemann.de

Programming In-/Output Output Bit setting BWU1853 BWU1917 Article number Parameter (first adress) Parameter P0: P0 1: Automatic switching between current and voltage 0: Current / voltage specified by P1 and P3 P1: P1 If P0= 0 1: OutI active 0: OutU active, otherwise not used P2: P2 1: Profil 7.3 is monitored 0: Profil 7.3 is not monitored BWU1361 BWU1362 BWU1722 not used P3: P3 If P0= 0 1: InI active not used 0: InU active, otherwise not used Parameter (second adress) P0, P1: Transformation speed InI, InU 11: fastest: 1ms/8 Bit 01: medium speed/precise: 5 ms/12 Bit 10: highest precision: 20 ms/16 Bit 00: not used P2: 1: 10V= 10000, 20mA= 20000 0: 10V= 27648, 20mA= 27648 (Siemens format) P3: 1: Pin 3 and Pin 4 bridged 0: Pin 3 and Pin 4 not bridged Programming notes Article no. ID-Code ID1-Code ID2-Code IO-Code BWU1893, BWU1895, BWU1963 1 A Code definition 9 7 ID1 14 Bit 11 Bit Channel 1 0; 2; 3 1 Channel 1 and 2 4; 5; 7 (Default value 6 ID1=7) BWU1853, BWU1917 0 - the ID code 1 can be written for all slaves, but only the X 6 slave with the lowest address defines the code for the remaining slaves. - ID1 is the same code for all slaves. - The code ID2 for all slaves (different for each according to his profile) is specified by the code ID1. number of connected AS-i slaves ID1= A: 2 AS-i slaves corresponding to 8 Bit ID1= B: 3 AS-i slaves corresponding to 12 Bit else: 4 AS-i slaves corresponding to 16 Bit BWU1894, BWU1964 3 (Default value ID1=F) D 7 BWU1359, BWU1363, BWU2532, 3 (Default value ID1=F) E 7 BWU2049, BWU1360 BWU1361, BWU1362, BWU1722 3 (Default value ID1=F) 6 7 1. BWU1893, BWU1895 + 1963 can transfer either 11 or 14 Bi-values Via ID1 the data capacity and the channel number can be defined. www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 12.12.12 page 5

M12 Connections: BWU1359, BWU1360, BWU1853, BWU1917 BWU1895, BWU2086, BWU2532 BWU1361, BWU1362 BWU1722 BWU1893, BWU1894, InI, InU OutI, OutU BWU1363 BWU1963, BWU1964 1 24V 24V Sig+ CH+ CH+ Sig+ Sig+ 2 Sig+ Sig+ 24V CHS+ CHS- n.c. 24V 3 0V 0V Sig- CH- CH- Sig- Sig-/0V 4 Sig- Sig- 0V CHS- * n.c. n.c. 5 Shield Shield Shield Shield Shield Shield Shield *) Pin 4 bridged inetrnally to Pin 3 Accessories: AS-i substructure module to connect 2 AS-i flat cables (article no. BW1180) AS-i substructure module to connect 1 AS-i flat cable, 1 flat cable for additional supply (article no. BW1181) AS-i substructure module to connect 2 AS-i round cable (article no. BW1182) AS-i substructure module to connect 1 AS-i round cable, 1 round cable for additional supply (article no. BW1183) AS-i substructure module to connect 2 AS-i flat cables with addressing socket (article no. BW1438) 3 4 5 2 1 page 6 Mannheim, 12.12.12 We reserve the right to change any data www.bihl-wiedemann.de