Technical Data. General specifications. Rated operating distance s n 3 mm

Similar documents
Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Inductive sensor BI1.5-EG08-Y1-H1341

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Technical Data. Dimensions

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Inductive sensor BI5-EM18-Y1X-H1141

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Sensor boxes SRBG Key features

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

T EN TROVIS Electropneumatic Positioner

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Pneumatic Control/Feedback

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Pneumatic Control/Feedback

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

Pneumatic Control/Feedback

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Series 3730 Type Electropneumatic Positioner

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Safety switches for hinged doors

5 Fieldbus Technology

Series 3730 Type Electropneumatic Positioner

NAMUR INDUCTIVE SENSOR ATEX/IECEx

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Electrical connection

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Terminal Boxes Series 8118

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Inductive sensor with analog output BI15-M30-LI-EXI

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Material pressure (bar) (Cv (US) kv x 1,2 Seat

HERION SERIES Indirect solenoid actuated spool valves

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Safety switches with separate actuator

Series 3730 Electropneumatic Positioner Type

ExCos-P Pressure sensor 20 Pa Pa

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Safety switches with manual mechanical delay and separate actuator

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Load Disconnect Switches and Motor Switches

PI-EX-ME-2NAM/COC-24VDC

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

Data Sheet T EN

PHOENIX CONTACT - 12/2007

LS 6600 Technical Datasheet

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

PI-EX-ME-2NAM/COC-120VAC

Series 3730 Type Electropneumatic Positioner

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Temperature Switches

Digital electropneumatic positioner SideControl

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Safety Switches CES-AR/CET-AR

Safety switches with separate actuator

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Operating pressure (bar)

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Data Sheet T EN

Level measurement CleverLevel LBFI Point level detection

Safety instructions Overvoltage protection B81-35

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Sensor boxes SRBE Key features and product range overview

Digital Positioner 8049

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Diffuse reflection light scanner with background suppression. Dimensioned drawing

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Series 3730 Type Electropneumatic Positioner with HART communication and pressure sensors

Transcription:

0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof housing for outdoor applications Rugged metal base LEDs for switching state of sensor and solenoid valve Plug-in terminals Temperature range Accessories BT65-F31K2-RG-EN-01 Activator for F31K2 series including protective housing SH-F31K2-B13 Protective cap for mechanically protected mounting SH-BT65-F31K2-01 Protective housing for activator BT65-F31K2-RG-EN-01 Technical Data General specifications Switching function 2 x normally closed (NC) Output type NAMUR Rated operating distance s n 3 mm Installation flush mountable Assured operating distance s a 0... 2.4 mm For assured operating distance s ar see Manual Functional Safety. Actual operating distance s r 2.7... 3.3 mm typ. Actuating element Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Reduction factor r St37 1 Reduction factor r Brass 0.5 Output type 2-wire Nominal ratings Nominal voltage U o 8 V Switching frequency f 0... 3 khz Hysteresis H typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection yes Suitable for 2:1 technology yes, Reverse polarity protection diode not required Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Time delay before availability t v 1 ms Switching state indicator LED, yellow Valve status indicator LED, yellow Functional safety related parameters Safety Integrity Level (SIL) SIL 2 MTTF d 1730 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Valve circuit Voltage max. 32 V DC Current max. 240 ma Short-circuit protection no Reverse polarity protection yes, with reversed output LED is out of function, therfore more power for solenoid valve Ambient conditions Ambient temperature Storage temperature Mechanical specifications Connection (system side) Screw terminals, tightening torque min. 0.5 Nm Stripped length 7 mm, M20 x 1.5 Core cross-section (system side) rigid: 0.14... 2.5 mm 2 flexible: 0.14... 1.5 mm 2 flexible with core-end sleeve: 0.25... 1.5 mm 2 like connection (system side) like core cross section (system side) PC (glass-fiber-reinforced Makrolon) powder coated aluminum IP66 / IP68 / IP69 2 Nm M20 x 1.5 ; 4 Nm 1 Nm LED switch-off Connection (valve side) Core cross-section (valve side) Housing material Housing base Degree of protection Tightening torque, housing screws Tightening torque, cable gland Tightening torque, stopping plug Note General information Use in the hazardous area see instruction manuals Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibility NE 21:2007 Standards EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 Approvals and certificates UL approval CCC approval culus Listed, General Purpose, Class 2 Power Source CCC approval / marking not required for products rated 36 V 1

Dimensions 106 95 100 75 I II 11 14 53 B13 M20 M20 30 57 89 44.5 78 Electrical Connection II I 7 6 5 4 SII- SII+ SI- SI+ 10 9 8 3 2 1 V+ V- GND V- V+ Interruption of LED: In the case of a polarity reversal of the valve circuit connection/s, the valve status display does not function, i.e. such that low power valves can (also) be connected. 2

Data for application in connection with hazardous areas Equipment protection level Ga, Gb, Gc (ic), Da Equipment protection level Ga NCN3-F31K2...-N4... II 1G Ex ia IIC T6...T1 Ga Ex ia IIC T6...T1 Ga for ATEX at U i = 15 V, I i = 25 ma, P i = 34 mw, T6 : 55 C (131 F) T5 : 65 C (149 F) T4 : 95 C (203 F) T3 : 95 C (203 F) T2 : 95 C (203 F) T1 : 95 C (203 F) T6 : 50 C (122 F) T5 : 65 C (149 F) T4 : 90 C (194 F) T3 : 90 C (194 F) T2 : 90 C (194 F) T1 : 90 C (194 F) T6 : 45 C (113 F) T5 : 55 C (131 F) for IECEx at U i = 15 V, I i = 25 ma, P i = 34 mw, 3

Equipment protection level Gb NCN3-F31K2...-N4... II 1G Ex ia IIC T6 T1 Ga Ex ia IIC T6...T1 Ga at U i = 15 V, I i = 25 ma, P i = 34 mw, 4

Equipment protection level Gc (ic) CE marking PF 13 CERT 2895 X II 3G Ex ic IIC T6 T1 Gc at U i = 20 V, I i = 25 ma, P i = 34 mw, at U i = 20 V, I i = 25 ma, P i = 64 mw, at U i = 20 V, I i = 52 ma, P i = 169 mw, Equipment protection level Da NCN3-F31K2M-N4-B13... II 1D Ex ia IIIC T135 C Da Ex ia IIIC T135 C Da at U i = 15 V, I i = 25 ma, P i = 34 mw : 50 C (122 F) at U i = 15 V, I i = 25 ma, P i = 64 mw : 45 C (113 F) at U i = 15 V, I i = 52 ma, P i = 169 mw : 40 C (104 F) 5