RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Similar documents
RТTH DUAL ROOM SWITCH

RXTP ROOM TEMPERATURE

RXTH DUAL ROOM SENSOR / SWITCH

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

Room Temperature Controller

Priva Blue ID Digital input module DI4/DI8/DI16

Priva Blue ID Relay output module DOR4/DOR8

InBin-P Pressure switches from 5 Pa Pa

Installation manual CF8-W-Disp-AL

DOR6. Components All functions and indications are on the front of the module. Characteristics

Blue ID Power injection module PI60

Instruction Manual. T3110 T3110L T3110Ex

Priva Blue ID Analogue output module with manual override AO2m/AO4m

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Electrical Actuators

Room unit with PPS2 interface

Installation manual for for Schleifenbauer DPM3

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Electrical Actuators

PSBOC PSBOC 27,6V/5,5A/OC

CMSA-100 Manual. Cinema Media Server Automation

Room Temperature Controller

Electromotoric actuators

MC 11 EB-2 Power supply cabinet with external bus, AC version

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

OZONE SWITCH Model OS-6. OS-6 Features

OPERATING INSTRUCTIONS

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Operating instructions. Standstill monitor A / / 2011

Priva Blue ID Communication module RS485 SC44

BA/BS4S Temperature Sensor Installation & Operating Instructions

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at


ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

Heating Circuit Controller

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

External level devices for conductive point level switch

1. Safety Precautions

GENERAL SAFETY GUIDELINES

Blue ID Communication module RS485 SC44

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

SMART-e Document Rev1

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

InCos-P Pressure sensor 20 Pa Pa

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

MAXIMA+ Series Rotary Level Indicator

Rhino PSM Power Supplies. Operating Instructions

Heating Circuit Controller

Analog Input/Output Modules

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

1. Short description. 2. Features. 3. Technical parameters

COMPACT eco -DIN Document Rev1

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Overview of types. Technical data

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

MAXIMA + Series ROTARY LEVEL CONTROL

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Manual Control Unit GFC 32

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Switched Mode Power Supply Operating manual PAP800

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Priva Blue ID C-Line Mix input/output module MX34

Electronic Temperature Controller. Instruction Manual Version

7032 Digital-Analog Multimeter

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

CDD Carbon Dioxide Transmitter

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Room Temperature Controllers

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

Transcription:

Mounting and operating instructions

Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS MOUNTING & OPERATING INSTRUCTIONS IN STEPS VERIFICATION OF INSTALLATION INSTRUCTIONS 7 TRANSPORT AND STOCK KEEPING INFORMATION 7 WARRANTY INFORMATION AND RESTRICTIONS 7 MAINTENANCE 7-7

SAFETY AND PRECAUTIONS Read all information, the datasheet, mounting instructions and wiring scheme before working with the product. For personal and equipment safety, and for optimum product performance, make sure you entirely understand the contents before installing, using, or maintaining this product. For safety and licensing (CE) reasons, unauthorised conversion and / or modifications to the product are not permitted. The product must not be exposed to abnormal conditions, such as: extreme temperatures, direct sunlight or vibrations. Chemical vapours with high concentration in combination with long exposure times can affect the product performance. Make sure the work environment is as dry as possible; check for condensation spots. All installations shall comply with the local health and safety regulations and local electrical codes. This product can only be installed by an engineer or a technician who has an expert knowledge of the product and safety precautions. Avoid contacts with energised electrical parts; always treat the product as if it is life. Always disconnect the power source before connecting the power cables, servicing or repairing the product. Always verify that you apply appropriate power supply to the product and use wires with appropriate size and characteristics. Make sure that all the screws and nuts are well tightened and fuses (if any) are fitted well. Recycling of equipment and packaging should be taken into consideration and disposed in accordance with local and national legislation / regulations. In case there are any questions that are not answered, please contact your technical support or consult a professional. - 7

PRODUCT DESCRIPTION ARTICLE CODES The RTT is a room temperature switch. It features multiple ranges selectable by jumpers, two relay outputs and two selectable switching points. INTENDED AREA OF USE TECHNICAL DATA STANDARDS Code Supply Connection RTT-G VAC ± 0 % - wire 8 VDC RTT-F 8 VDC - wire Temperature control in HVAC applications For indoor use only relay outputs: C/O (0 VAC / A) Power consumption: no load: max. ma full load: max. ma Selectable temperature ranges: 0 0 C / 0 0 C / 0 0 C / 0 0 C Selectable switching points: 0 0 C Selectable hysteresis: / / / C Enclosure: rear lid: plastic ABS, black (RAL900) front cover: ASA, ivory (RAL900) Protection standard: IP0 (according to EN 609) Operating ambient conditions: temperature: 0 0 C rel. humidity: < 9 % rh (non-condensing) Storage temperature: -0 0 C Low Voltage Directive 006/9/EC EMC Directive 00/08/EC: EN 66 WEEE Directive 0/9/EU RoHs Directive 0/6/EU - 7

OPERATIONAL DIAGRAMS Relay output Relay output rel on rel on rel off 0 SP-hyst SP 0 T, [ C] rel off 0 SP-hyst SP 0 T, [ C] WIRING AND CONNECTIONS Vin Positive DC voltage / AC ~ GND Ground / AC ~ NO Normally open contact COM Common contact NC Normally closed contact NO Normally open contact COM Common contact NC Normally closed contact Connections Cable cross section: max., mm MOUNTING & OPERATING INSTRUCTIONS IN STEPS Before you start mounting the RTT temperature switch, read carefully Safety and Precautions. Choose a smooth surface for an installation location (a wall, panel and etc.).. Open the white cover by releasing the locking plates on both sides of the cover and remove it. (See Fig. Locking plates release.). Insert the cables through the cable opening of the enclosure rear lid. (See Fig. Mounting dimensions.). Fix the unit to the wall / panel taking into account that the unit has to be installed at a minimum height of, m and the air flow has to pass free. Mind the correct mounting position and unit dimensions. See Fig. and Fig.. Fig. Locking plates release Fig. Mounting dimensions Fig. Mounting position 9,8 Acceptable Not acceptable x Ø 6 7, 9,8 0,6 Keep, m. minimum distance from the floor 0, 70, 0, - 7

. Do the wiring according to the wiring diagram (see Fig. ) using the legend information from section Wiring and connections. Fig. Wiring and connections Relay contacts Normally closed Common Normally open Relay contacts Normally closed Common Normally open Power supply VAC ± 0% / 8 VDC. Customise the factory settings to the desired ones. Use:. jumper JP to select the temperature range (see Fig. Sensor range selection jumper);. jumpers JP and JP to select the hysteresis value (see Fig. 6 Hysteresis selection jumpers); Fig. Sensor range selection jumper Fig. 6 Hysteresis selection jumpers 0 0 C 0 0 C 0 0 C 0 0 C JP JP JP JP JP JP JP JP C C C C. trimmer VR to select the switching point for relay, trimmer VR to select the switching point for relay (see Fig. 7 Setpoint trimmers). Fig. 7 Setpoint trimmers 6. Close the enclosure and fix the cover. 7. Switch on the power supply. 6-7

ATTENTION Do not exceed the maximum power supply rating! Measure before installation! Unregulated VAC supply units provide higher nominal output voltage and activate the integrated fuse protection. ATTENTION If a G-type article is using the same AC power supply source (transformer) as F-type article, a SHORT CIRCUIT may result when the power supply and analogue signal terminals are connected to the same common ground! In this case always connect different article types to separate AC transformers or use the same article version. VERIFICATION OF INSTALLATION INSTRUCTIONS Check the status of the blue ON/OFF LED after you switch on the power supply. (See Fig. 8.) The ON/OFF LED should blink during the initialization period (0 s) at equal intervals. Then it should give out continuous blue light. If this is not the case, check the connections again. Fig. 8 Operating indication TRANSPORT AND STOCK KEEPING INFORMATION Avoid shocks and extreme conditions; stock in original packing. WARRANTY INFORMATION AND RESTRICTIONS MAINTENANCE Two years from the delivery date against defects in manufacturing. Any modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities. The manufacturer bears no responsibility for any misprints or mistakes in this data. In normal conditions this product is maintenance-free. If soiled, clean with a dry or dampish cloth. In case of heavy pollution, clean with a non aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry. 7-7