Panduit Basic Rack PDU

Similar documents
Panduit Basic Rack PDU with Local Meter

SmartZone Gateway- Enabled M Series Rack PDU

G5 PDU Installation Guide

E1135C PDU and Pod Upgrade Procedure

SmartZone Network-Enabled MS Series Rack PDU

* * Agilent Power Distribution Unit (PDU) Installation Guide

hp uninterruptible power system r12000 xr models installation instructions

Power Supply and Fan Module Installation

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

VRp Three-Phase Precision AC Voltage Regulator

Power Supply Installation

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Installing Cisco RP-Series PDUs

WBS HARDWIRED SERIES 4-60KVA MAINTENANCE BYPASS SWITCH

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

Liebert MicroPOD 230V

Multilin EPM 4600 Metering Solution

M250 (M LL) Safety

Installing the Cisco MDS 9020 Fabric Switch

PowerLogic High Density Metering System 1-Meter Enclosure

M215 (M215-60) Safety

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

HPE Intelligent Power Distribution Unit Installation Instructions

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Enphase S-Series Microinverter and Engage Cable Safety

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

NI PXIe-1062Q Power Supply Shuttle

Broadband Automatic Disconnect Switch. User Manual

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

GE Digital Energy Multilin EPM 4600 Quickstart Guide TELEPHONE: FAX: HOME PAGE:

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

Startup Guide C01

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

User s Guide. POWERVAR Single Phase Power Conditioners

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

Wa r n i n g-wa r n i n g-wa r n i n g

M215-Z Safety Information (M LL-IG-ZC)

InView Firmware Update

Instruction Manual. Rack PDU XP Series. geistglobal.com

Installing the Cisco AS5400XM Universal Gateway

Cisco CRS 16-Slot Chassis Power Systems

INSTALLATION INSTRUCTIONS

Power Supply and Fan Module Installation

Model 2657A-LIM-3 LO Interconnect Module

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

Polar PDUs POWER MANAGEMENT

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

Replacing the Power Supply

MINI 4200 Model # - C Mini Instruction Manual V.2. This instruction manual serves as a guide for the Mini 4200.

OilCop Component Wiring Installation Manual

Installation and Maintenance

Cisco ASR 1004 Router Overview and Installation

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Active UTP Transceiver Hub with Integral Isolated Camera Power

Ethernet Test Access Panel (ETAP) User Manual

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

Model 2380 Rack-Mount Kit

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

RIGOL. Installation Guide. RM-DS-1 Rackmount Kit. Digital Oscilloscope. May RIGOL Technologies, Inc.

Rack Mount Power Supplies

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installation and Operations Manual

MS-SL12-RD. 17-Outlet LCD Display Power Strip 20Amp INSTRUCTION MANUAL

E-Series Site Preparation Guide

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

2260B-RMK-Series Rack Mount Kit

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Avanti HP Series Centrifuges Preinstallation

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Rack Installation Instructions

Perle MCR200 Installation Guide

Enphase Engage Cable and Accessories

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

The Basics of Selecting Rack-Mount Power Distribution Units (PDUs) and Power Strips

Instructions for Operation of S&C Test Accessory Catalog Number TA-2669

and above SSD Remote Mounting Kit Instructions

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

DRIVE DOCK. User Guide

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Instruction Manual: IM E

Transcription:

Panduit Basic Rack PDU User Manual Release 1.0 Issue 1.0

Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording or otherwise, without written permission from Panduit. No patent liability is assumed with respect to the use of the information contained herein. Although every precaution has been taken in the preparation of this book, Panduit assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein. - 2 -

Table of Contents Basic Rack PDUs 4 Contacting Panduit 4 Symbols Used 4 Equipment Overview 5 Model Numbering Format 5 Part Numbering Format 6 Pre-Installation 7 Product Inspection 7 Installation 8 Before You Begin 8 Hardwire PDU installation instructions 8 Unterminated Cord PDU installation instructions 10 Standard Accessories 10 Additional Required Items 10-3 -

Basic Rack PDUs Panduit Basic Rack PDUs provide reliable power distribution to devices installed within a cabinet. This equipment has been designed for connection to an IT power distribution system. Contacting Panduit For technical support on PDU hardware and associated software, please contact Panduit Technical Support using one of the following methods: 1-866-721-5302 (toll-free), Monday-Friday, 7:30 am - 5:00 pm CST systemsupport@panduit.com Symbols Used Symbol Description Danger Electric Shock Hazard Warning Possible Safety Hazard Primary Earth Ground Secondary Earth Ground ON O OFF - 4 -

Equipment Overview The power inlet/cord(s) connects the PDU to the electrical power source. The LCD displays the current load for each input feed or electrical phase per input feed. For IEC C-20 inlet PDUs, a customer-supplied cord is used for connection to the power source. The connection end to the PDU has an IEC C-19 plug for connection to the PDU. The opposite end of the cord has a plug suitable for connecting to the customer-supplied receptacle. The cord and plug shall be rated for 20A in North America and 16A outside of North America. Make the connection to the PDU before connecting to the power source Model Numbering Format This section describes the model numbering format used to identify equipment in the PDU series. PDU model numbers are: HD-YYYVZZA HE-YYYVZZA VD-YYYVZZA VE-YYYVZZA The letters in the series represent values as defined in the table below. Letter H V D E YYY ZZ What It Represents Horizontal series Vertical series Basic - no monitoring or display provided Metered - on board display only May be any number, 120-415, representing rated voltage May be any number, 10-63, representing rated current - 5 -

Part Numbering Format This section describes the part numbering format used to identify equipment in the PDU series. PDU devices are numbered using one of the following formats: H1M-ABCDEFGHJKLM V1M-ABCDEFGHJKLM The H1M prefix indicates that the model is intended for horizontal mounting. The V1M prefix indicates that the model is intended for vertical mounting. The remaining letters in the series represent values as defined in the table below. Letter A B CD* E F GH JK L M What It Represents Any numeral, 1-8, indicating the phase wiring for the output circuit breakers and receptacles Any letter, A-F, indicating input cord configuration Any numeral, 1-5, and any letter, A-Z, indicating input plug type and rated voltage Any numeral, 1-7, indicating the number of output circuit breakers Any letter, A-Z, indicating the type of overload protection provided for the outlets Any two numerals, 01-45, indicating the number of output receptacles provided The letter A or B followed by any letter, A-Z, indicating the type and quantity of output receptacles provided Any numeral, 0-9, or any letter, A-Z, indicating the length of the power supply cord Any numeral, 0-9, indicating the color of the enclosure * Voltage and amperage ratings: 120V, single-phase, 10A, 12A, 15A, 16A, 20A, 24A or 30A 208V, single-phase, 10A, 12A, 13A, 15A, 16A, 20A, 24A, 30A, 48A or 60A 230V, single-phase, 16A, 32A, or 48A 208V, three-phase (delta), 16A, 20A, 24A, 30A, 40A, 48A, 50A or 60A, 3W + PE 208V, three-phase (wye), 16A, 20A, 24A, 30A, 48A or 60A, 3W + N + PE 400V, three-phase (wye), 16A, 20A, 24A, 30A, 32A, 48A or 60A, 3W + N + PE - 6 -

Pre-Installation The Rack PDU products covered by this guide are designed to be installed within EIA racks and cabinets. Use of this product in other applications is acceptable, but other precautions may be required to allow for specific installations not covered by this guideline. Product Inspection Inspect the product prior to installation. If the product has any visible signs of damage, please contact the supplier. - 7 -

Installation Before You Begin Before installing your PDU, refer to the following lists to ensure that you have all the items shipped with the unit as well as all other items required for proper installation. Hardwire PDU installation instructions This product is intended to be hardwired by the customer must be installed by a qualified electrician AND adhere to all national & local electrical codes. 1. To install, remove the (4) securing screws on the removable user panel. 2. Unscrew strain relief grommet cap (indicated below) and feed the power cable through the grommet cap & the input gland. 3. Ensure conductors are stripped adequately, exposing 15mm of copper. 4. Conductors shall be connected in-line with the terminal markings provided as shown below (Line 1 = X; Line 2 = Y; Line 3 Z). Ensure screws are secure for each conductor by applying a torque of 2.3 N-m (20 in-lb.). - 8 -

5. Ensure conductors have enough slack (none should be under tension). 6. Feed grommet cap down cord and secure to input gland. Reference the table below to ensure the grommet cap is torqued correctly. Gland Size Grommet Cap Torque M16 1.5 N-m (13 in-lb.) M20 M25 M32 M40 M50 M63 3.0 N-m (27 in-lb.) 4.0 N-m (35 in-lb.) 15 N-m (132 in-lb.) 20 N-m (177 in-lb.) 30 N-m (266 in-lb.) 7. Re-install removable cover plate with the screws removed in step 1. 8. Connect the other end of the power cord to a suitably rated disconnect device. 9. Switch utility circuit breaker On. - 9 -

Unterminated Cord PDU installation instructions This product is intended to be hardwired by the customer must be installed by a qualified electrician AND adhere to all national & local electrical codes. To install, match the corresponding conductor color to the matching phase in your facility. Reference the color guide below: Conductor Insulation Color Line Number / Phase Brown Line1 / X Black Grey Blue Green (may include Yellow stripe) Line 2 / Y Line 3 / Z Neutral Ground Standard Accessories Mounting hardware: Vertical models: Affixed button mounts Horizontal models: Appropriate local mounting brackets and screws Additional Required Items Flathead and Phillips screwdrivers Appropriate local AC power receptacle to power the PDU - 10 -