UNIVERSAL DIMMER DIM04SA/500U

Similar documents
UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM02SA/500U

Product and functional description

Product and functional description

Product and functional description

Product and functional description

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Push Button Interface UP 220D31

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

The LED display (1) turns green when the load is switched on.

Product and functional description

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Installation and User Guide

CTD01: mini-controller with USB

1-channel shutter actuator 6A UP Installation Instructions

MINI-PS AC/10-15DC/8

Operating Instructions. DALI-Gateway

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Operating voltage Maximum

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

4 CHANNEL UNIVERSAL DIMMING ACTUATOR

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Operating and mounting instructions

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

picture 1: Device components

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Product and functional description

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

EM2020 Selectable AC transducer A (UK)

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Monitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings.

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Power supply module, bus connection module

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

584 5WG AB_1 DELTA

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Speed monitor D / / 2014

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Installation and User Guide

DALI Professional Controller-4. Control unit Operating instructions

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

PHOENIX CONTACT Features

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Operating instructions. Switching amplifier DN0210 DN / / 2015

Nemo SX - Multifunction control module

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

RM35TF V AC

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

Signal Doublers. VariTrans A 20300

Push button UP 287, 4 - fold

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Operating Instructions

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

ABL8REM24030 regulated SMPS - 1 or 2-phase V AC - 24 V - 3 A

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

EMS CX 3 - Modbus/EMS Interface

PHOENIX CONTACT - 07/2006

Product manual. Mylos KNX 350w Dimmer 2CSYK1205C/S

ETD-BL-1T-OFF-CC- 10S

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

LL1x150-CR-DA. 150 W Dimmable DALI-2 LED driver. 150 W V 0 / Hz. Functional Description. Mains Characteristics

HabiTEQ. Home & Building Automation

Power Supply HARTING pcon

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Conductive Level Controller

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

Communications & Networking

Transcription:

overheating, overvoltage or short-circuit, the red ERROR-LED will be on. The output can be reset by putting it in the OFF-status. The DIM04SA/500U module also has 5 potential-free inputs to connect standard push buttons. Input 1 to 4 control respectively output 1 to 4, input A is a sceneinput which executes an ALL OFF-scene when pushing for 0,7 seconds (and then releasing the button), or a PANIC-scene (All Outputs on) when pushing the button for 3 seconds. The inputs are set standard in push button mode. When de DIM04SA/500U is connected to a controller, the input mode of the DIM04SA/500U can be changed to Normal Open, Normal Closed or toggle. Figure 1 : Dimmer module DIM04SA/500U 1. Product Description This module can function both Stand-Alone (so WITHOUT Controller, WITHOUT external power supply) but can also be connected to a Controller to become part of a full-fledged Qbus installation. The DIM04SA/500U is a DIN-rail module, suitable for dimming 4 loads of 10-500VA. The dimmers operate digitally with 8 bit precision. An optical separation between the inputs and outputs guarantees safe operation. The DIM04/500U can be used with incandescent lamp, halogene lamps, capacitive loads, inductive loads, certain dimmable energy-savings lamps and dimmable 230V LEDs. WARNING: Dimmable energy-savings lamps and 230V LED-lamps will need to be set to a minimum dim-value via the Qbus Configuration software. These minimum-values need to be set when the lamp is cold. Dim-values which are too low will cause the lamp to oscillate and can significantly reduce the expected life of the lamp. If the Dimmer is used in Stand-Alone mode, the connected load and minimum dim-value can be set manually for each circuit. See below under Manual Control for more details on how to set these values. If the dimmer is used as part of a full Qbus installation (with a Qbus Controller), the load and minimum dimvalue can be set via the Qbus configuration software. DIM04/500U is short-circuit resistant, has overvoltage and overheating protection and has a built-in CRC filter (Filters central remote control signals when applicable, to prevent oscillation and buzzing of lamps and fittings in areas with high electricity network pollution). When the dimmer goes into safety mode because of The module also contains four LED outputs to be used as feedback on swathe push buttons. In order to use the LED feedback, an external 24V power supply needs to be installed. The dimmer outputs can only be used as a one-button dimmer. As a one-button dimmer the dimming cycle must always be completed: starting from zero to maximum and back to zero. A short pulse (< 0.3secs.) will take the dimmer to zero or to the maximum value in 2.5secs. The maximum value can be adjusted from 5% to 100%. The lighting can also be dimmed automatically after a set time of 1 sec to 255mins. If the dimmer is controlled via a scene, the cycle time for 0%-100% or vice versa can be set between 0,3 seconds and 20 minutes. Each module has a unique serial number enabling programming anywhere and anytime. After a voltage cut-off the outputs return to their latest position. The DIM04/500U is protected with a 500mAT fuse. Ensure adequate ventilation in the fuse box. A bipolar automatic fuse of a maximum of 16A must be placed on the mains power. 2. Safety Instructions Read the complete manual before carrying out the installation and activating the system. WARNING The device must be mounted, serviced and commissioned, by an authorized electrician in accordance with the country-specific regulations. This device is exclusively suitable for DIN-rail mounting EN 50022. It must be mounted in a fireproof closed distribution board and should be well ventilated. Air ventilation must be ensured. QBUS NV. Page 1/5

A safety disconnection of the device must be possible. Before servicing the DIM04/500U the mains voltage should be disconnected. Only transfomers that are approved for dimming operation may be used. Pay attention to prevent noload operation of conventional, dimmable transformers during commissioning or during operation. The Dimmer is intended to work with incandescent lamp, halogene lamps, capacitive loads, inductive loads, dimmable energy-savings lamps and dimmable 230V LEDs. Mixed operation of different load types is not permitted. The device must not be opened. Warranty will be void if the module has been opened. 3. Mounting and wiring The DIM04SA can be used in different installation configurations. Following specifications however will remain the same across the different configurations: POWER SUPPLY : A bipolar automatic fuse of a minimum of 16A must be placed on the mains power 230Vac. Conductor cross section : maximum 1,5mm². Remove approx 7mm of insulation from the wire and srew it into the terminals Ph-N. WARNING: BEFORE WORKING ON THE DEVICE DISCONNECT THE SUPPLY VOLTAGE. INPUTS : Both solid and stranded wire between 0,5 1, 5 mm 2 can be used (for stranded use a screwdriver to push on the connection when inserting the wire). Remove approx 7mm of insulation from the wire and push it into the input terminals 1-A. By pushing with a screwdriver on the connector, the wire can be removed from the connector. Input 1/2/3/4 controls respectively output 1/2/3/4. Input A is set as a scene-input. Pushing the pushbutton connected to Input A for 0,7 seconds will turn all outputs on the REL04SA OFF. Pushing the same button for at least three seconds will turn all outputs ON. LED OUTPUTS An external 24V power supply can be connected to the REL04SA in order to provide LED-feedback on the push buttons. LED INDICATION : Green led : power supply. Red STATUS -led: start-up 2 seconds and during programming. This LED will also flash while selecting the load and the minimum dim-level. Orange Leds 1-4 continuously on: output active. These LEDs will flash if the respective output has gone into safety-mode (overheating, overload, short-circuit). Bring the output back to its OFF-status, the orange led will be turned off and the output can be controlled again (if the issue causing the safety-mode has been resolved). FITTING : This device is exclusively suitable for DIN-rail mounting EN 50022. LOAD CIRCUITS : Connect the loads. Conductor cross section : minimum 1,5mm². Remove approx 7mm of insulation from the wire and screw it into the terminals 1 4. The DIM04/500U can be used with incandescent lamp, halogene lamps, capacitive loads, inductive loads, certain dimmable energy-savings lamps and dimmable 230V LEDs. The load can be chosen via the System Manager software or using the buttons on the DIM04SA module as described below under Manual Control. MANUAL CONTROL : Used to directly control the outputs of the module or to select the connected load and the minimum dim-value if the dimmer is used in Stand-Alone mode. Each output can be controlled via the button under the respective output. To select the connected load, follow this procedure: 1) Ensure all outputs are OFF (= all orange LEDs are off). 2) Push both the buttons under output 1 and output 2 simultaneously for 4 seconds. 3) The red STATUS LED on the module will flash fast during 5 seconds, and will then start to flash at a different speed. 4) 2 seconds after the STATUS LED has been flashing at a different speed, release one of the two QBUS NV. Page 2/5

buttons; 2 seconds later release the other one. The red STATUS LED will now continue to flash; the module is in configuration mode. 5) The outputs are standard set for Conventional transfo s. If other loads need to be dimmed, the respective load can be selected by pushing a number of times on the button underneath that output. The orange LED will lighten up each time the button has been pushed. See table below - next to the load type you will find the number of times the button of that output needs to be pushed: Load Choice Conventional transformers 1 Electronic transformers 2 Incandescent lamps 2 Halogen lamps 230V 2 Retrofit led 230V (preferable) 2 Retrofit led 230V (alternative) 1 CFL with 100% startup (preferable) 3 CFL with 100% startup (alternative) 4 If no buttons have been pushed during 4 seconds, the module will get out of the configuration mode and the red STATUS LED will stop flashing. 6) The minimum dim-level can also be set in Stand- Alone mode. Follow steps 1 to 4 above to get back in to the configuration mode. See table below to find out how many times the button needs to be pushed to select a certain minimum dim-level: Megaman - Dimmable energy savings lamp 8W, 11W 2700K - Dimmable LED 8W 2800K. Osram: - Dimmable energy savings lamp DULUX Superstar 14W - 230V LED Parathom PAR16 50 Philips: (advanced) - dimmable LED 6W 2700K, 7W 3000K 40D, 12W 2700K 25D, Meanwell: - PCD-16-350B met 2x AL10430 spots - PCD-16-350B met 3x activeline Luga 7) The memory function means that the dimmer remembers what the set value was when turning the dimmer off. Example: If the dimmer is set to 60% on power off, the light will automatically turn on 60% when switched on. See table below to find out how many times the button needs to be pushed to activate/deactivate the memory function: Memory function Choice Memory function off 9 Memory function on 10 CABLING OPTIONS Option 1: Stand-Alone Low Dimming Limit (DimMin) Choice 0% 5 10% 6 20% 7 30% 8 If one of the buttons during configuration mode is pushed for 5 seconds, that output will be put back in to factory settings (= Conventional transformer and 10% minimum dim-level). A successfull RESET will be shown by 10 flashes of the orange LED of that channel. REMARK: if you want to select a certain load for an output, and also select a minimum dim-level for this same output, you need to put the module in to configuration mode, select the load (push 1 to 4 times), get out of configuration mode, get back in to configuration mode and select the minimum dimlevel (push 5 to 8 times). Following energy savings lamps and 230V LED-lamps have been testen on the DIM04SA/500U: GE: - LEDPAR30 - Electronic CFL 20W Multiple REL04SA modules can be connected with each other. QBUS NV. Page 3/5

Option 2: Stand-Alone with LED-feedback Maximum humidity : 93%, no moisture condensation Bus load : 10mA at nominal 13,8V Fuse : 500mAT single-phase Max installation altitude : 2000meters With extra 5-24V power supply for LED-feedback on push buttons. Here in combination with a Niko push button type 170-401Y1 or 170-401Y0 Option 3: with controller as part of a complete Qbus system No module, switch or push button needs to be replaced. A Qbus controller provides all-in- and output modules power and data via the two-wire bus. This module contains clocks, scenes, presence simulation, logic, Via the Ethernet port of the controller, the installation can be connected to the internet and can be controlled remotely via smart phones, tablets etc. It is recommended to use the EIB cable or any other cable with minimum 2 x 1mm² conductors as bus lead. 4. Technical Data GENERAL SPECIFICATIONS : Power supply : 230Vac +-10%, 50Hz - maximum protection 16A/2P. This device is exclusively suitable for DIN-rail mounting EN50022. Insulation voltage : 3 kvac tested Characteristic consumption : 4.5VA Ambient temperature : Working temp. range : 10 C to 70 C Storage temp. range : -10 C to 70 C OUTPUTS : 1 4 : dimmable outputs for halogen, incandescent, dimmable 230V LED and dimmable CFL lamps. Maximum load : Incandescent / halogen with electronic transfo: max 500VA at 230Vac each circuit Halogen with classic (magnetic) transfo max 400VA at 230Vac each circuit CFL and 230V LED lamps max 100W each circuit Minimum load : Incandescent / halogen / 230V LED load: 10VA at 230Vac each circuit CFL lamps 10W each circuit PHYSICAL SPECIFICATIONS Housing : Plastic, self-extinguishing acc. to UL94- V0 Protection Degree : IP20, EN60529 Installation : rapid mounting on DIN-RAIL, width 9 modules Dimensions (HxWxL) : 62mm x 90m x 161mm Weight : approx. 0,400 kg ELECTRICAL SAFETY Bus : 13,8VDC safety extra low voltage. Complies according EN60950 1:2006. Dielectric strength: module has been tested (and approved) 3kVac. (50Hz, 1 min.) Non-toxic WEEE/RoHS compliant. Class II equipment. CE Complies with the EMC regulations and low voltage regulations. The device complies with HBES EN50090-2-2:2002 and EN60950 1 : 2006 +A11:2009 + A1:2010 + A12:2011 + A2:2013. QBUS NV. Page 4/5

5. Dimension Diagram Width = 9 modules, 1 Module = 17mm. 6. Guarantee provisions Period of guarantee: 2 years from date of delivery. Any faulty devices should be send postage-free with a description of the defect to our customer service office : QBUS N.V. Joseph Cardijnstraat 19 9420 Erpe-Mere Tel : +32 (0)53 60 72 10 Fax : +32 (0) 53 60 72 19 Email : support@qbus.be QBUS NV. Page 5/5