User Manual. RS485 Option Board for SV-iS5/iH Series. LG Industrial Systems

Similar documents
SAFETY PRECAUTIONS. Throughout this manual we use the following two illustrations to make you aware of safety considerations:

User manual. MODBUS-RTU SV-iC5

User Manual. PROFIBUS-DP Option Board for SV-iS5 Series. LG Industrial Systems

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

PROFIBUS-DP Option Board for SV-iS5 Series

Before using the product, thank you for using our Ethernet module board. Safety Instruction

DeviceNet Option Board

Safety Instruction. This symbol indicates the possibility of injury or damage to property.

Varispeed SERIES OPTION CARD DeviceNet COMMUNICATION INTERFACE CARD USER'S MANUAL Model: SI-N1

SAFETY PRECAUTIONS CAUTION. WARNING Improper operation may result in serious personal injury or death.

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

Tongta Inverter TDS-F8

Thank you for purchasing ig5a Series DeviceNet Communication Module SAFETY PRECAUTIONS

Firmware Manual - EC Series Drives

DeviceNet Interface Option "OPC-E1-DEV"

Safety PRECAUTIONS. Danger may be present. Read the message and follow the instructions carefully.

PROFIBUS DP Interface Option "OPC-E1-PDP"

Communications Quick-Start Guide

N700E Inverter RS485 Interface Instruction Manual

MCH Series Drives Metasys N2 Communications Guide

Before using the product, thank you for purchasing SV-iS7 DeviceNet option board. SAFETY PRECAUTIONS

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

EQ5 SERIES Quick Start Guide for Constant Torque Applications

Optidrive VTC Modbus RTU Register Map

The following conventions are used to indicate precautions in this manual.

TOSVERT VF-S9 Communications Function Instruction Manual

for more: efesotomasyon - sanch inverter S2000 is RS-232C built-in. It is available for RS-485 when WI-K2 interface card is added.

CJ-series DeviceNet Connection Guide OMRON Corporation 3G3RX-V1 Series Inverter

GPD 506 / Modbus RTU Technical Manual

Step 1: Choose the Appropriate CPU Step 2: Make the Connections

CAUTION. WARNING Improper operation may result in serious personal. CAUTION Improper operation may result in slight to medium

DeviceNet Interface Card "OPC-F1-DEV"

Quick Start Guide RSi S Series VFD. Using the 7-segment (4 digit LED) Keypad/Display

SAFETY PRECAUTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Inverter (VFD) Manual

DeviceNet Interface Option "OPC-E1-DEV"

E2 Modbus RTU Register Map

Optidrive Applications Support Library

MU110-6U. Analog output module 6 channel. User guide

Bosch Rexroth EFC3610 Frequency Inverter. Easy Start Guide L1 L2 L3 (+) B U V W

MP15 Jockey Pump Controller

Optidrive Applications Support Library

Profibus DP Interface Option "OPC-E1-PDP"

APPLICATION GUIDE Connection to Toshiba Adjustable Speed Drives

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

The RS-485 user manual for B800 series communication

MC3000 Series Drives Metasys N2 Communications Guide

Installation & Technical Manual

Operating Instructions RMx621

Before using the product, thank you for purchasing MDLV-HP DeviceNet option board. SAFETY PRECAUTIONS

COMMUNICATIONS INTERFACE

PowerFlex 4 / 40 Custom Firmware

Copyright: December 2017 Nidec Issue: E

Profibus DP Expansion Board

Modbus Interface Module

Before using the product, thank you for purchasing SV-iS7 CANopen option board. SAFETY PRECAUTIONS

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Marathon Drives. PROFIBUS-DP Option board MDLV-100P Series. Read this manual carefully before using the PROFIBUS-DP Option

Before using the product, thank you for using our MD100G Ethernet option module Safety Instruction

3GV M Modbus RTU Register Map

LS M100 Frequency Inverter Easy Start Guide

Before using the product, thank you for using our MDLV-HP Ethernet option module. Safety Instruction

PROFIBUS DP Interface Card "OPC- F1-PDP"

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

DeviceNet Expansion Board

EC-TX107 BACnet/IP communication card. Contents. Contents... 1

smd Series Drives Modbus Communications Reference Guide

MRZJW3- SETUP154E. General-Purpose AC Servo Servo Configuration Software MODEL INSTALLATION GUIDE

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

Communication Network. DeviceNet Communication

Maximum Value for OEMs SM. NX70 Serial Communications Unit (SCU) User Manual

Operation manual. HDOM-Profibus-V0. More options please visit;

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250

YASKAWA AC Drive 1000-Series Option EtherNet/IP. Technical Manual

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

User manual. TRIOU(Temperature Remote I/O Unit) Before using the product, be sure to read Safety Cautions, and use exactly as described.

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor INSTRUCTION MANUAL DOCUMENT NO Rev. 1.

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

Remote Keypad "TP-E1"

OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FSCA-01 RS-485 adapter module User s manual

Operator Manual for Profibus

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive

Quick Start Guide For GVX9000 AF Drives

Before using the product, thank you for purchasing SV-iP5A CANopen option board. SAFETY PRECAUTIONS

Carbon Monoxide Sensor - ModBus

TOSVERT VF-AS3. Trace Tool PCT003Z-E. Instruction Manual

User Manual. RNet Option Board SV-iS7 Series. LS Industrial Systems

Mitsubishi Electric Automation Instruction Manual FR-A5AC-01

Kinetix 300 Memory Module Programmer

MC Series Drives Modbus Communications Reference Guide

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

[ ACD-NA ] User s Manual. O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea

PROFIBUS MODULE (CB15) English Operating Instructions. Contents. Warning and Caution Notes

DVPPF02-SL PROFIBUS DP Slave Communication Module

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

TOSVERT VF-nC1 Communications Function Instruction Manual

Transcription:

User Manual RS485 Option Board for SV-iS5/iH Series Read this manual carefully before using the RS485 OPTION BOARD and follow the instructions exactly. After reading this manual, keep it at handy for future reference. LG Industrial Systems

Thank you for purchase of LG RS 485 Option Board! SAFETY PRECAUTIONS Always follow safety precautions to prevent accidents and potential hazards from occurring. Safety precautions are classified into WARNING and CAUTION in this manual. WARNING CAUTION Indicates a potentially hazardous situation which, if not avoided, can result in serious injury or death. Indicates a potentially hazardous situation which, if not avoided, can result in minor to moderate injury, or serious damage to the product. Throughout this manual we use the following two illustrations to make you aware of safety considerations: Identifies potential hazards. Read the mage and follow the instructions carefully. Identifies shock hazards. Particular attention should be directed because dangerous voltage may be present. Keep this manual at handy for quick reference. CAUTION Do not touch the CMOS components unl the board is grounded. ESD can cause break down of CMOS components. Do not change the communication cable with the inverter power is applied. Otherwise, there is a danger of connecting error and damage to the board. Make sure to precisely insert the connector of inverter and option board Otherwise, there is a danger of connecting error and damage to the board. Check the parameter unit when setting the parameters. Otherwise, there is a danger of connecting error and damage to the board.

1. INTRODUCTION By using a RS 485 OPTION BOARD, SV-iS5/iH inverter can be connected to a RS 485 network. 1.1. When you use the RS 485 Option Card Inverter can be controlled and monitored by the sequence program of the PLC or other master module. Up to 31 drives or other slave devices may be connected in a multi-drop fashion on the RS- 485 network and may be monitored or controlled by a single PLC or PC. Parameter setting and change are available through PC. Interface type of RS485 reference - Allows the drive to communicate with any other computers. - Allows connection of up to 31 drives with multi-drop link system. - Noise-resistant interface Users can use any kind of RS232-485 converters. The specifications of converters depend on the manufacturers. Refer to the converter manual for detailed specifications. Before Installation Before installation and operation, this manual should be read thoroughly. If not, it can cause personal injury or damage other equipment. 2. SPECIFICATION 2.1. Performance specification Items Communication method Transmission form Applicable inverter Number of drives Transmission distance Converter Specifications RS485 (Using RS232-485 Converter) Bus method, Multi-drop Link System IS5/iH series drive Maximum 31 drives connectable Max. 1200m (L than 700 m recommended) RS232-485, Use PC with RS232 card embedded 2.2. Hardware Specifications Installation Power Supply Items Control B/D Comm. B/D Specifications Option connector on the inverter control board 5V dc supplied from inverter power supply Power supplied using 5V DC-DC converter on option board 1

2.3. Communication Specification Items Communication speed Control procedure Communication system Character system Stop bit Specifications 1200 /2400/4800/9600/19200 bps Selectable Asynchronous communication system Half duplex system BINARY (8 bit) 1 bit 2 byte Parity check None 3. PRODUCT DETAIL 3.1. Layout and detail Name Description Connector Connector to inverter main PCB P 485 signal - high Signal Communication N 485 signal low connection signal connection G 485 Ground terminal terminal S Shield T1, T2 Connect a terminating resistor Figure 1-1. Installating RS485 Option Card to SV-iS5 2

RS485 Board Figure 1-2. Installating RS485 Option Card to SV-iH 3.2. Status LED Normal operation of the board Receiving 485 signal Responding to 485 signal 3

4. INSTALLATION 4.1. Option board installation guide 1. Remove the keypad on the inverter and connect the RS485 option board (See the Figure 1). 2. Double check the board is firmly installed to the board and then apply the inverter power. 3. When power ON, CPU LED is blinking per second after all LEDs blink one after another. 4. If CPU LED is not blinking, turn off the inverter power swiftly (if not, inverter and the board may get damaged.) and check for the proper installation of the board. If the problem persists, contact LG distributor. 5. Check I/O 47 is set to RS485. 6. When the above condition is met, set the communication parameters as shown below. [For SV-iS5] Parameter code Display Setting Value (Verify the assigned number is not duplicated.) 9600 bps (Factory default) Factory default [For SV-iH] Parameter code Display Setting Value (Verify the assigned number is not duplicated.) Factory default Factory default 7. Turn off the inverter power to connect the converter when step 6 is finished. 8. Connect the terminating resistor at the end of network (See the figure 3). 4

4.2. RS232-485 converter installation See the converter manual for accurate installation. 4.3. Computer, Converter and RS485 Option Card Configuration System configuration Maximum cable length is 1200m but recommended length is within 700. The number of connectable inverter is 31. Computer 232/485 Converter Option card Option card Option card Inverter 1 Inverter 2 Inverter n Figure 2. System configuration Communication signal connection Figure 3. Option card terminal layout 5

5. COMMUNICATION PROTOCOL 5.1. Supported command codes 5.2. BroadCast Function 5.3. Error Code 6

6. TROUBLESHOOTING Refer to this section when communication error occurs. 7

7. PARAMETER CODE (HEX) <Common>: Area accible regardl of inverter models (Note 2) Parameter Addr Parameter Name Unit Read/Write Data Value (Hex) 0000 Inverter model - R 4: SV-iS5 3:SV-IH SV-iS5 0: 0.75 1:1.5 2:2.2 3: 3.7 4: 5.5 5: 7.5 6: 11 7: 15 8: 18.5 9: 22 A: 30 B:37 C:45 D: 55 E: 75 F: 90 10: 110 11: 132 12: 160 13: 200 14: 220 0001 Inverter capacity - R 15: 280 16:375 (Unit: kw) SV-IH A: 30 B: 37 C: 45 D: 55 E: 75 F: 90 10: 110 11: 132 12: 160 14: 220 (Unit: kw) 0002 Inverter Input Voltage - R 0: 220V 1: 440V 0003 S/W Version - R SV-iS5 0100: Ver. 1.00, 0101: Ver 1.01 SV-iH 0200 : Ver. 2.00, 0201: Ver. 2.01 0004 Parameter Lock - R/W 0: Lock (default) 1: Unlock 0005 Frequency Reference 0.01Hz R/W 0-60000 0006 Run Command - R/W Bit 0: Stop Bit 1: Forward Run Bit 2: Reverse Run Bit 3: Fault Reset Bit 4: Emergency Stop (Bit 0 also resets fault) 0007 Acceleration Time 0.1 sec R/W 0008 Deceleration Time 0.1 sec R/W 0009 Output Current 0.1 A R 000A Output Frequency 0.01 Hz R 000B Output Voltage 0.1 V R 000C DC Link Voltage 0.1 V R 000D Output Power 0.1 kw R 8

Parameter Addr Parameter Name Unit Read/Write Data Value (Hex) SV-iS5 Bit 0: Stop, Bit 1: Forward Running Bit 2: Reverse Running Bit 3:Fault (Trip) Bit 4: Accelerating Bit 5: Decelerating Bit 6: Output Frequency Arrival Bit 7:DC Braking, Bit 8: Stopping Bit 9: Not used Bit10: BrakeOpen Bit 11: FWD Run Command ON, Bit 12: REV Run command ON, Bit13: Rem. Run/Stop Bit14: Rem. Freq. Cmd 000E Sequence Monitor - R SV-iH BIT 0 : Stop BIT 1 : Forward Run BIT 2 : Reverse Run BIT 3 : Fault (Trip) BIT 4 : Accelerating BIT 5 : Decelerating BIT 6 : Output Frequency Arrival BIT 7 : DC Braking BIT 8 : Stopping BIT13: Rem. Run/Stop BIT 14: Rem. Freq. Cmd 000F Trip information - R SV-iS5 Bit 0:OCT1,Bit 1: OV, Bit 2: EXT-A Bit 3: BX, Bit 4:OCT2, Bit 5: GF, Bit 6: OH,Bit 7: ETH, Bit 8: OLT, Bit 9: HW-diag,Bit10:EXT-B,Bit11:FO Bit12:OPT,Bit13:POBit,14:IOLT, Bit15:LV SV-iH Bit 0: OC Bit 1: OV Bit 2:EXT Bit 3: BX Bit 4:LV Bit 5:FUSE OPEN Bit 6: GF Bit 7: OH Bit 8: ETH Bit 9:OLT Bit 10: MCF Bit 12: SCT Bit 15: IOLT 9

Parameter Addr Parameter Name Unit Read/Write Data Value (Hex) 0010 Input Terminal Status - R SV-iS5 Bit 0: P1, Bit 1: P2, Bit 2: P3 Bit 3: P4, Bit 4: P5, Bit 5: P6, Bit 6: RST, Bit 7: BX, Bit 8: JOG, Bit 9: FX, Bit 10: RX SV-iH Bit 0: FX Bit 1:RX Bit 2:BX Bit 3: RST Bit 8: P1 Bit 9: P2 Bit 10: P3 Bit 11: P4 Bit 12: P5 Bit 13: P6 0011 Output Terminal Status - R Bit 0: Q1 (OC1), Bit 1: Q2 (OC2) Bit 2: Q3 (OC3) SV-iS5 Bit 3: AUX Bit 4: 30AC SV-iH Bit 3: AUX1 Bit 4: AUX2 x0012 V1 - R 0x0013 V2 - R 0x0014 I - R 0x0015 RPM - R SV-iS5 0 FFC0 SV-iH 0-FFFF SV-iS5 0 FFC0 SV-iH 0-FFFF SV-iS5 0 FFC0 SV-iH 0- FFFF (Note 2) The changed value in Common affects the current setting but returns to the previous setting when power is cycled or Inverter is reset. However, changing value is immediately reflected in other parameter groups even in the case of Reset or Power On/Off. 10

SV-iS5 Addr Addr 11

Addr Addr 12

Addr 13

Addr 14 (Note 3,4,5,6) Value depends on motor capacity. Addr

Addr 15

Addr 16

Addr Addr 17

Addr 18

Addr Addr Addr 19

Addr 20

Addr 21

Addr 22

Addr 23

LG LG Industrial Systems Co., Ltd. LGIS constantly endeavors to improve its product so that information in this manual is subject to change without notice. Visit Our Website: http://www.lgis.com/ December 23, 2002 Publication #: 10310000414 1