DCF OPTIMIZED RACK SYSTEM. Selection Guide

Similar documents
VERTIV VR RACK. Selection Guide

F-SERIES Innovative Rack Solution

S-Series Superior Rack Solution for Data Centre & Network Closets

Vertiv VR Rack 1.0 GENERAL

S-SERIES 2 Superior Rack Solution for Data Center & Network Closets

RACK POWER DISTRIBUTION FOR CRITICAL IT EQUIPMENT. Rack PDU Solutions

Liebert XDA Air Flow Enhancer. User Manual

VERTIV RACK PDUS. Power Perfectly Configured for Your IT Application

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing

V800 Cabinet Solution

QuickSpecs. HPE G2 Advanced Series Racks. Overview

RE Series Rack from Eaton Product Presentation

DCM Modular Rack System Advanced Features and Customizable Options For Unique Data Center Needs

QuickSpecs. HPE G2 Enterprise Series Racks. Overview

APPLYING PROPER CABLE MANAGEMENT IN IT RACKS. A Guide For Planning, Deployment And Growth

DATACOM CABINETS SOLUTION GUIDE

ARE YOUR RACK PDUS KEEPING YOU FROM OPTIMIZING POWER MANAGEMENT?

POWER PRODUCTS AS INCLUDED IN OUR PLATINUM RESELLER, JEM TECH'S NY STATE CONTRACT

EF-Series EuroFrame Gen 2 Cabinet System

Knurr Miracel Server Rack

V800. Cabinet V800 CABINETS

or

Rack 111 Catalog. Designed and Built to Exceed Your Needs.

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Liebert DCW CATALOGUE

QuickSpecs. HPE G2 Advanced Series Racks. HPE G2 Advanced Series Racks. Overview

Vertiv Local Rack Access 18.5" LED LCD Console

Vertiv DCM Colocation Rack. Secure, Separate Server Hosting and Housing in Data Centers

SYSTIMAX Rack and Cabinet Solution

RittalXpress TS IT Enclosure Assemble-to-Order Program

APC Open Frame Rack Networking Solutions

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

Two-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center

HYPERFRAME CABINET & ENCLOSURE SOLUTIONS

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

Hassle-free equipment installation

QuickSpecs. HP Rack G2 Series - top view

Hassle-free equipment installation

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

QuickSpecs. What's New. HP G2 Series Racks. Overview

ADDRESSING CHALLENGES TO POWERING SMALL TO MIDSIZE IT SPACES

QuickSpecs. What's New. HP G2 Series Racks. Overview

EMEA. Product Catalog. RackLine. AT&T Rack & Enclosure LAN Cabling Products. AT&T Cabling Systems

The Most Advanced Racking Solutions Available!

Product catalog. Eaton RS Enclosure. Easy to configure power, cabling and airflow

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

QuickSpecs. HP Rack Series. Overview. HP Rack Series - 36U

Rack Installation Instructions

Liebert. MB Flexible Modular Busway

QuickSpecs. HP Rack G2 Series Overview

CABINETS & CONTAINMENT SOLUTIONS GUIDE. designed to be better

QuickSpecs. What's New. HP G2 Series Racks. Overview

How to Sell APC s Cisco Approved Solution for Nexus 7018

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

Rack Solutions RS-2. Free Standing Racks & Cabinets Wall Mount Racks, Cabinets, & Brackets Shelving Cable Management Accessories RS-5 RS-10 RS-12

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Aisle Containment Systems. Physical Containment Systems Selection Guide

Knurr Racks And Accessories

W DATA SHEET: FREE-STANDING DATA ENCLOSURES DS

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

QuickSpecs. HP Rack Accessories. QuickSpecs. Retired

Rack Installation Instructions

Cabinet Solutions

Thermal management. Thermal management

Floor Standing Rack Cabinet

Titan Media Cart. Installation and Operation Manual

V-Built Custom Preconfigured Solutions

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

Featured Products - RU Marking Standard on Hoffman brand

Rack PDU Marketing Playbook

Liebert STS2/PDU, Static Transfer Switch 2/Power Distribution Unit. A Streamlined Package For Power Distribution And Source Switching

Powerware Enclosure Solutions Product Focus

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

Liebert. CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Liebert. STS2/PDU, Static Transfer Switch 2/ Power Distribution Unit A Streamlined Package For Power Distribution And Source Switching

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

PowerChain Management solutions. Enclosure Solutions

1.866.TRY.GLCC WeRackYourWorld.com

QuickSpecs. HP Rack G2 Series. Overview

UltraRack. Advanced Data Centre Enclosures SR SERIES

QuickSpecs. What's New. HP Rack G2 Series Overview

Titan Cable Management Catalog TCM3.0. IMS Engineered Products is ISO 9001 Certified. Designed and Manufactured in the USA

Specification Sheet: HT SERIES

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

ACSUS-11. Access Cabinet Systems Cabinets & Accessories

DIGITUS Server Cabinet Unique Series

Lenovo 42U 1200mm Deep Racks Product Guide

w w w. e l e c t ro n m e t a l. c a

Configurable power distribution

Rackmount Shelves, Wallmount Shelves, Keyboard/Mouse Trays

Netfinity White Paper Netfinity Technology Center

Transcription:

DCF OPTIMIZED RACK SYSTEM Selection Guide

DCF OPTIMIZED RACK SYSTEM Optimized Design, Optimized Delivery, Optimized Value A Rack System Designed to Meet The Challenges Your Data Center Faces Today Your mission-critical networks are carrying an ever-increasing amount of voice, data and video. Looming on the horizon is a critical mass of VoIP, high speed access, wireless applications and increasing demand for blade server deployment. The DCF optimized rack system from Vertiv integrates your computing hardware, power management technologies and peripherals in your data center. It gives superior design and flexibility, allowing optimal data center equipment performance and easy installation. DCF Rack is UL certified 2416 Flexibility: yavailable in nine standard sizes, to meet site needs ycompatible with Vertiv Rack PDUs, Liebert rackmount UPS, Aisle Containment and Liebert MB modular busway all from a single source yfactory installation of rack PDUs, for fast deployment ytool-less accessories simplify cable management, airflow management and component mounting ystatic load capacity up to 3000lbs/1,363kg ysimple integration of power, cooling and monitoring equipment DCF Rack 24U DCF Rack 42U Higher Availability: y75% front and rear door perforation provides maximum airflow to internal equipment yeasy access to and management of equipment yfront and rear locks for security yfast on-site deployment yergonomic yairflow and perforation ycable Management Lowest Total Cost of Ownership: yeasy installation saves time and money: lift off hinges, dual side panels, 19 rail adjustment, U markings on 19 rails, low profile casters, tool-less accessories yexcellent value for features, durability and price yintegral part of the total data center solutions from Vertiv saves time and money on configuration and integration 2

Improve Data Center Efficiency With A Solid Foundation Welded Steel Construction Roof Top Ready for Cabling Removable opening for cable entry ready for front/rear/side cabling. Can accomodate over 2500 Cat 5e cables. 75% Perforation On Doors Optimal door perforation allows greater airflow through the cabinet, reducing heat buildup. Tool-less Cable Management Requires just inserting and twisting the tool-less accessories on 19 vertical mounting rail. Integrated 19 rail alignment. Insures 19 rails are positioned correctly without measuring. Split, Locking Side Panels For quick and easy installation and maintenance. Locks provide security. Low Profile casters Low profile casters allow 42U racks access thru a standard doorway 3

DCF OPTIMIZED RACK SYSTEM Specifications DCF Rack PART NUMBER U HEIGHT MM (IN) F4611 24 1200 (47.2 ) F2611 42 2000 (78.1 ) F2612 42 2000 (78.1 ) F2811 42 2000 (78.1 ) F2812 42 2000 (78.1 ) F8611 48 2250 (88.6 ) F8612 48 2250 (88.6 ) F8811 48 2250 (88.6 ) F8812 48 2250 (88.6 ) WIDTH MM (IN) 600 (23.6 ) 600 (23.6 ) 600 (23.6 ) 800 (31.4 ) 800 (31.4 ) 600 (23.6 ) 600 (23.6 ) 800 (31.4 ) 800 (31.4 ) DEPTH MM (IN) 1100 (43.3 ) 1100 (43.3 ) 1200 (47.3 ) 1100 (43.3 ) 1200 (47.3 ) 1100 (43.3 ) 1200 (47.3 ) 1100 (43.3 ) 1200 (47.3 ) Standard Features ysingle perforated locking front door ysplit rear door, locking * ysplit side panels, locking yhigh density cable entry roof (2500+ cat 5 cables) ylow profile caster and leveling feet y2 Sets 19 EIA rails y2 Full height rack PDU/cable management brackets yhardware Kit (Qty 50 M6 Cage Nuts and Screws) *F4611 is a single perforated rear door ybolt down brackets ykeys ycentral grounding point ytool-less accessories available yliebert MB attachment option yul 2416 approval AIR FLOW MANAGEMENT Blank Panel 19 Tool Less Blanking Panel A frequently over looked component in air flow management, blanking panels allow you to close unused U space. This forces incoming cool air to pass through active components with pull fans already installed in your cabinet. Available in 1U and 2U. 010200087 1U Plastic Tool Less Blanking Panel; Box of 10 010200088 2U Plastic Tool Less Blanking Panel box of 5 Vertical Filler Panel Kit Full height Vertical filler panels that mount to outside edge of the 19 rail and extend to the plane of the side panel. The vertical filler panels for the DCF Optimized rack utilize 2 half height panels per side. Each kit is enough for 1 cabinet. 42U panel has 1 1U cut out per panel with brush strip that can be used for cable pass through. 48U panel has 2 1U cut outs with brush strip in the top and 1 1U cut out with brush in the bottom. 546074G1L 546281G1L 42U x 800mm wide 48U x 800mm wide 4

Air Diverter for IT Switch Captures and directs all of the hot exhaust air out the rear of the rack and into the hot aisle when a side breathing switch is used. Available in 4U, 12U, 15U, and 21U. Consult your switch manufacturers airflow specifications before applying. 546659G1L 4U Air Diverter 546659G3L 15U Air Diverter 546659G2L 12U Air Diverter 546659G4L 21U Air Diverter SHELVES AND SUPPORT BRACKETS 19 Fixed Tool less Shelf 19 adjustable vented shelves provides added versatility and accessibility with load rating of 275lbs (135kg). Features Materials / Finish yadjustable Depth for installation y23.5 (570mm) to 46 (1168mm) ysurface Area 17.25 (438mm) W x 23.5 (570mm) D y1u Tool Less mounting shelf yhigh grade cold rolled steel 1.5 mm thickness ypowder coat finish ystandard color is RAL 7021 black grey 002185000 19 Fixed Tool Less Shelf; 275lbs load rating Telescopic Shelf 19 Telescopic Shelves A high quality bearing slide mechanism provides smooth and convenient action for our shelves. The mounting kits are installed to the inside flange of the 19 rails. Depths range from 22.3 (566mm) to 46.0 (1168mm). Supports loads up to 110lbs (50kg) 535809G1 Telescopic Shelf 110lb load rating L Shaped depth adjustable support Rails When additional support is needed for heavy loads, our support rails provide a suitable option. Depth Adjustable, the rails mount into the 19 rail side flanges and can support loads up to 110lbs (50kg) 542777G1L Support Rail Depth adjustable; load rating 110lbs 5

DCF OPTIMIZED RACK SYSTEM RPCBDM Bracket Bracket attaches to the perf door and holds the RPCBDM display so it can be viewed without having to open the rack doors. 538619G1L RPCBDM bracket to mount BDM display to perforated door XDV Mounting Bracket Allows the XDV product line to be mounted properly on top of the rack. 546080G1L 546079G1L 600W XDV mounting bracket 800W XDV mounting bracket CABLE MANAGEMENT 19 Cable Routing Panel with D Rings 19 rack mounted cable routing panel with D rings provide the solution to those loose cables in the front or rear of your rack. Panels available in 1U height. 011171448 19 Cable Routing Panel with D rings 1U Metal Blanking panel with Brush Strip ycan be used as a blanking panel and allows for cable pass thru ycolor: RAL7021, Black ysupplied in kit of 2pcs 542190G1L 1U Metal Blanking Panel w/ Brush 6

Tool Less Cable Management Lobster Claw ¼ Turn tool-less cable management piece offers the ultimate in flexibility in cable management. These can be installed on the outside edge of the 19 rail or on the PDU/ Cable Management rail. 002185050 Pack of 10 Lobster Claw 002185070 Pack of 100 Lobster Claw Tool Less Cable Management Velcro Strap ¼ Turn tool-less cable management piece offer the ultimate in flexibility in cable management. These can be installed on the outside edge of the 19 rail or on the PDU/Cable Management rail. 002185060 Velcro Strap Pack of 10 002185080 Velcro Strap Pack of 100 19 Cable Trough 19 1U rack mount cable trough that mounts on the 19 rails for effective horizontal routing of cables. ECT015 19 Cable Trough Roof Mount Cable Management Kit Roof mount cable management easily directs cables along the top of the row of racks. Includes front, center and rear piece. 546273G1L 546274G1L Roof mount cable management kit for 600W Roof mount cable management kit for 800W Roof Mount Horizontal Cable Management Kit Roof mount cable management easily directs cables along the top of the racks. The horizontal cable management piece runs front to rear on each end of the row. 546343G1L 546344G1L Horizontal cable mgmt kit for 1100mm deep cabinet. Includes 2 pieces Horizontal cable mgmt kit for 1200mm deep cabinet. Includes 2 pieces 7

DCF OPTIMIZED RACK SYSTEM CABLE MANAGEMENT / FANS / ADDITIONAL ACCESSORIES Horizontal Cable Manager Horizontal Cable Manager Mounts on the EIA rails to easily manager cables. Available in 1U and 2U. 548784P1 548785P1 1U Horizontal Cable Manager 2U Horizontal Cable Manager Vertical Cable Management Finger System - 18U Allows for the passing of cables from rack to rack keeping the same U location.comes in a Kit of 2 18U finger sections. 010200078 Kit of (2) 18U Vertical Fingers includes mounting hardware Cable Cover for Vertical Cable Fingers Cover snaps on the cable fingers section to hide cables. 546545P1 546547P1 Cable cover for vertical cable manager 600 to 800 W rack configurations Cable cover for Vertical Cable Manager 800 to 8000W rack configurations Back Plane for Vertical Cable Fingers Back Planes install on the back side of the Vertical Cable Finger and allows for cable pass thru. 546550P1 546553P1 Cable Backplane for Vertical cable Manager 600 to 800W rack configurations Cable Backplane for Vertical cable Manager 800 to 800W rack configurations 8

Fans Fans for Top Cover. 163796G1L 163796G3L 1000L Low Noise Fan 1000H High Ambient Fan Additional Accessories Handle options 546058G1L 546059G1L 546060G1L Door Handle (1ea) Door Combo Lock (1ea) Keys (Set of 4 keys) Cluster Gasketing Kit 546078G1L Gasketing that seals space between suited racks. 23 EIA Rail Spacing Kit Kit allows the EIA rails on an 800mm wide DCF rack to be adjusted to 23 spacing in lieu of the standard 19 rail placement. 548649G1L 23" EIA Rail Spacing Kit for 800W rack 9

DCF OPTIMIZED RACK SYSTEM ADDITIONAL ACCESSORIES DCF Bolt Down Brackets *Included with shipment of rack. If you need additional brackets you can order under part # below. Can be used to secure rack to Data Center Floor. 546268G1L DCF Bolt Down Brackets (Set of 2) Full Height PDU/Cable Mgmt Bracket Each DCF rack ships with a qty 2 full height PDU/Cable mgmt bracket installed. You can order additional ship loose full height PDU/Cable mgmt brackets. 546076G1L 546077G1L 42U 4 Full height PDU/Cable mgmt Bracket (1ea) 48U 4 full height PDU/Cable mgmt bracket (1ea) DCF Casters *All racks include swivel casters. If you need to order additional casters please use part number below. 546269G1L DCF Casters (Set of 4) Mounting Hardware One set included with each rack. Set includes 50 ea M6 cage nuts, plastic cup washers with matching screws. (1) cage nut installation/removal tool. If additional hardware is required order part number below. 546189G1 DCF Mounting Hardware Seismic Anchor Kit 548233G1L DCF Seismic Anchor Kit 10

Rack PDU (Power Distribution Units) Enhance Business Agility, Efficiency and Availability with Vertiv Rack PDUs. DCIM software ACT VALIDATE Rack PDUs SEE SEE DECIDE ACT PLAN ANALYZE Connected IT infrastructure KNOW Data center investments are sizable, and each component of the power chain -from the building entrance to the rack power distribution - is crucial to enabling equipment availability. Enable your IT investment and your business to stay protected with Vertiv s family of rack PDU offerings. Vertiv s next generation of rack PDUs provides the industry s highest availability and most intelligent power metering and distribution complete with the simplified energy management, modular design and cost savings that ensure your data center and your business can operate at peak velocity and resiliency. Our complete portfolio of rack PDUs offers value beyond power distribution. They easily integrate to your data center infrastructure management systems to make your organization more resilient, enhance your business velocity and provide the technological support you need to grow your company. MPX and MPH2 Rack PDUs Intelligent, real-time infrastructure ycommunicate the status of rack-level power and environmental information to a centralized Data Center Infrastructure Management (DCIM) yallow monitoring and control to the receptacle level Optimized level of visibility and control yprovides the information needed to make informed decisions and enhance business agility 11

DCF OPTIMIZED RACK SYSTEM MPX : Confidently take on the uncertain future of connected power requirements with MPX, the most responsive and adaptive rack PDU available. With MPX rack PDU technology, you can respond easily to rack equipment changes and dynamic capacity requirements. MPH2 : MPH2 is the most intelligent, high availability line of managed rack PDUs. It offers remote monitoring and control capabilities as well as environmental input options, with multiple power input selections and output configurations. DI-STRIP: DI-STRIP rack PDUs meet a broad range of power distribution requirements for IT and other applications. Designed especially to handle the growing number of electronic components that can be housed within network cabinets and server racks, the space saving product line is available in a range of configurations. 12

MPX Adaptive Rack PDU Confidently take on the uncertain future of connected power requirements with MPX, the most responsive and adaptive rack PDU available. With MPX rack PDU technology, you can respond to rack equipment changes and dynamic capacities by leveraging: yhot-swappable modular output power yhot-swappable modular communications ymodular input power MPX Benefits yadaptive capacity, distribution, monitoring, control and management of critical devices yflexibility to respond to constant change redeploy modules to suit changing needs ybuy only what you need and build on your investment yenvironmental sensing with threshold and alarm set-points ynotification on the loss or removal of individual rack equipment loads Reconfigurable Power Capacity & Distribution The MPX rack PDU has a scalable design that allows onsite configuration to fit immediate IT equipment needs. It is the perfect choice to respond to the needs of a growing data center. Relocate or add IT equipment to support changing needs, by easily reconfiguring the power input and distribution. Fits Needs Now And Later The MPX rack PDU provides a wide selection of single phase and three-phase power input configurations with the ability to field change while maintaining distribution infrastructure. Designed for Critical Environments ycritical rack space operating temperature up to 55 C / 131 F to support hot internal rack environments yaccurate power metering of +/-1% voltage & current for assured oversight yenergy and power metering down to the individual receptacle ycomprehensive alarming including notification of overloaded branch circuits For a listing of available configurations, please visit the Vertiv PDU Selector at www.vertivco.com 13

DCF OPTIMIZED RACK SYSTEM MPH2 MPH2 is the most intelligent, highavailability line of managed rack PDUs. It offers remote monitoring and control capabilities as well as environmental input options, with multiple power input selections, output configurations, and form factors. Models in 0U, 1U, and 2U form factors are available in the following versions: youtlet Level Metered and Switched youtlet Level Metered yrack PDU Metered and Outlet Switched yrack PDU Metered MPH2 Benefits ymonitors electrical and environmental parameters with user-configurable threshold and alarm tools ycontrols and manages individual receptacles and/or groups of loads and devices Designed for Critical Environments yindustry leading operating temperature up to 60 C / 140 F to support hot Internal rack environments ybi-stable relays ensure basic power distribution in the event that intelligence is compromised yaccurate power metering of +/-1% voltage & current for assured oversight yenergy and power metering down to the individual receptacle ycomprehensive alarming including notification of overloaded branch circuits yenvironmental sensing with threshold and alarm set-points y Notification on the loss or removal of individual rack equipment loads yallows you to predict failing conditions before they occur and proactively manage connected equipment for maximum uptime yenergy and power metering to optimize the data center power and cooling infrastructure ylowest power consumption of all switched rack PDU designs ensures lower operating costs for datacenter yup to four MPH2 rack PDUs may be interconnected as a Rack PDU Array, consolidating user IP connections and device monitoring. 14

MPH2 Savings for a Typical Data Center TYPICAL 24 OUTLET RACK PDU MPH2 Rack PDU power consumption (Watts) 23 7.5 Rack PDU annual energy consumption (kwh) 24x7x365 202 66 Overall contribution to datacenter energy consumption (kwh)* 383 125 Cost of energy consumption (based on average cost of 10 /kwh) $38 $13 Annual savings per PDU with MPH2 $26 Annual savings per rack with MPH2 $52 Annual savings within the datacenter with MPH2 $5,160 Based on a a comparison of switched rack PDU models for a typical 100 rack data center with a PUE of 1.9. * per Energy Logic calculations For a listing of available configurations, please visit the Vertiv PDU Selector at www.vertivco.com 15

VertivCo.com Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA 2016 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. SL-11393 (R12/13)