PTR. printing temperature recorder. User Manual. order code:

Similar documents
CONTENTS Introduction 4 DTR overview 4 probes 5 functions 5 display 5 DTR operation 6 switching the DTR on or off 6 changing label 6 displaying

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

RS Stock No Instruction Manual RS Input Data Logging Thermometer

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

Infrared temperature measuring instrument

Flue Gas Analyzer. The Value Leader TM

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

Hand-held thermometer Model CTH7000

TA 888 Hot Wire Anemometer

Manual Anemometer PCE-423

PIECAL 520B & 521B Thermocouple Source Operating Instructions

Field Equipment for Measuring Electrical Conductivity, Humidity and ph of Soil

GA-12. madur Polska sp. z o.o.

I. SAFETY INFORMATION II. FEATURES III. GENERAL SPECIFICATIONS

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User Guide. ICP 300 In-Cab Printer. Operation

Quick Start Guide. Introduction. P4T/RP4T Overview

The Specification of Hot Wire Anemometer Manual PCE-423

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

FG-7000L Digital Force Gauge Operation Manual

FG-3000R Digital Force Gauge Operation Manual


Tone Alert and Ring Tone Amplifier

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

Dual channel temperature logger with display Instruction Manual

EVt and N2000 Series Dataloggers. EVSW Software Quick Start Guide

FG-3000 Digital Force Gauge Operation Manual

MONARCH INSTRUMENT. TACH-4A / TACH-4AR Programmable Optical Tachometer. Instruction Manual Rev 2.0

1 Platen Roller 2. Bar Sensor 3. Media Support Latch 5. Latch Release Button D Ring 7. Control Panel 8. QuickLink Module 9.

SP-L51. Portable Thermal Printer. User s Manual VER 1.00

N9002 THERMOMETER OPERATING INSTRUCTIONS

TRUE TEMPERATURE INDICATOR MODEL TTI-10 User Manual/Handbook

FG-7000 Digital Force Gauge Operation Manual

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Ultrospec 10 User Manual. English. Deutsch. Français. Español. Italiano

3 Channel Datalogging Thermometer

Manual Digital Thermometer PCE-T 390

VJ-1304 INSTALLATION MANUAL

MUTOH EUROPE N.V. Tel.:32-(0) Fax:32-(0)

Dual channel temperature logger with two binary inputs and LCD display Instruction Manual

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

Hand-held thermometer Model CTH7000

GB/UK. Operating manual. Data logger EBI USB

Operation Manual MODEL 3173/3173R. MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R

RJ-2030/2050/2140/2150

CENTER 521 INSTRUCTION MANUAL 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S)

USER GUIDE. Differential Thermometer Datalogger. Model HD200

MW-145BT Mobile Printer

RS Stock No Instruction Manual RS Input Data Logging Thermometer

NV12 QUICK START AND CONFIGURATION GUIDE

MTP INSTRUCTION MANUAL

Tinytag Thermohygrometer User Guide

SoundTrack LxT N/Forcer Model NFR w/printer FIELD OPERATION GUIDE

Differential pressure measuring instrument

HH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual

Operation Manual. Hand-held ph/orp/temperature Meter 6010M

Temperature logger with display Instruction Manual

PRODUCT INFORMATION. MCP7870 USB THERMAL PRINTER Series. Features

RW Series Overview. Introduction

DEFECTOMETER High detection sensitivity to surface flaws (even underneath paint) Simple, microprocessor-controlled operation

1. Presentation. 1.1 Instrument description. 1.2 Keys description

digiprint - Getting Started... Prerequisites Inserting the paper roll

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

Accsense Wireless System. Temperature Monitor

GMH Operating Manual for Digital Quick-Response Thermometer

recording Remote Temperature Monitoring remote temperature monitoring ThermaData loggers, WiFi or Bluetooth applications for remote monitoring

ST-140 Vibration Meter ST-140D Datalogging Vibration Meter User s Manual

Single Use USB Data Logger EBI 330-T30 / EBI 330-T85. User Manual

testo 175 Data loggers Instruction manual

User's Guide. EasyView K-Type Thermometer. Model EA11A

Instruction Manual Temp JKT Temperature Meter Series

DPP Micro Reader. The DPP Micro Reader is maintenance-free, not configurable by the user and is operated with a single, multi-function button.

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

Datalogging Hot Wire CFM Anemometer

PosiTector DPM. Dew Point Meter. INSTRUCTION MANUAL v Simple. Durable. Accurate.

Small Tool Instruments and Data Management DP-1VR. DIGIMATIC Mini Processor with integral printer

Indoor Air Quality Meter/Datalogger

RJ-2030/2050/2140/2150

ThermoSecure medical equipment GmbH

-Direct.com FG-3000 Digital Force Gauge Operation Manual

SINAR TECHNOLOGY MOISTURE PROBE USER MANUAL.

4-Channel Thermometer

MANUAL PCE-123

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

User Guide Automatic Transfer Switch (ATS)

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

Differential pressure measuring instrument

JUMO TDA-300 and JUMO TDA-3000 Handheld Thermometer with data logger

Installation Manual for D244X Series 24-volt Power Supplies

MetaDolce MD3600 IP65 Multi-Data Capture Tablet Quick Manual. 1. Keys and Connectors

DPL4000 Portable Low Range Dew Point Analyzer

VJ-1618 INSTALLATION MANUAL

Digital Quick-Response Thermometer

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

testo 176 Data loggers

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Transcription:

PTR printing temperature recorder User Manual order code: 226-275

2

CONTENTS Introduction 4 probes 4 functions 4 display 4 PTR overview 5 PTR operation 6 switching the PTR on or off 6 changing input 6 displaying limits 6 feeding paper 6 modes of operation 6 'on demand' mode 6 'summary' mode 6 'log mode' 7 batteries 8 recharging the PTR 8 connecting device to the PC 8 reset 8 cleaning 8 paper loading procedure 9-10 specification 11 3

INTRODUCTION The PTR (Printing Temperature Recorder) is a hand held temperature measuring device that prints and logs temperature readings. The PTR measures temperature across the range of -200 C/-328 F to 1372 C/2501 F, with a resolution 0.1 C/F above 1999.9 C/F. When the PTR is fully charged, up to 500 prints can be achieved. Up to 8000 readings can be stored in memory. PROBES The PTR can be used with the standard range of ETI thermocouple probes fitted with a miniature thermocouple plug. The probes are connected via the 4 miniature thermocouple sockets at the top of the instrument. FUNCTIONS The PTR control panel consists of five buttons: ON/OFF - Switches the PTR On/Off. INPUT - Changes selected input. LIMITS/START STOP - Displays High or Low Limit in 'on demand' mode. Starts and stops logging in 'log' and 'summary' modes FEED - Feeds the paper. PRINT - Takes a reading, prints a ticket and logs the reading, date and time in memory. DISPLAY The display consists of a 12 character alphanumeric section and a four and a half digit temperature section. Low battery indication is shown by 'Lo Bat'. 4

PTR OVERVIEW probe sockets printer cover cover handle 'reset' button USB socket LCD charge indicator power socket control panel 5

PTR OPERATION SWITCHING THE PTR ON OR OFF The 'On/Off' button switches the PTR on or off. 'Switch off' will be displayed for two seconds before shut down is complete. The unit cannot be switched off using the 'On/Off' button during a log. The log must be stopped first. CHANGING INPUT To scroll through the four inputs, press the 'Input' button. The selected input will be displayed on the screen. Inputs change in a continuous loop. Up to four inputs can be selected using the PC software. DISPLAYING LIMITS In 'on demand' printing mode the high or low limit for the selected input can be viewed by pressing the 'Limits' button. When the high or low limit is selected the temperature value displayed represents the corresponding limit and the name of the input alternates with 'High Limit:' or 'Low Limit:' respectively. FEEDING PAPER Press the Feed button to feed the paper. If there is no paper loaded or the printer cover is open, 'Paper out' will be displayed for five seconds. MODES OF OPERATION The instrument has six modes of operation, 'on demand', 'log do not print', 'Logging', 'print log summary using print button', 'print current temperature using print button' and 'print log summary and current temperature using print button'. 'ON DEMAND' MODE (Untick logging ) When the print button is pressed a temperature measurement will be taken from all selected inputs and a ticket containing the current temperature values along with whether the current readings exceeded limits will be printed. If there is no paper loaded or printer cover is open, 'Paper out' will be displayed for five seconds, but the reading will still be stored. After a ticket has been printed, the display will show 'Copy' for five seconds. 6

Pressing the 'Print' button during this time prints a copy of the last ticket. In 'on demand' mode all button functions are retained. LOGGING - 'DO NOT PRINT' MODE The print button is disabled, and the LIMITS/START STOP button is used to start and stop logging. To start logging, press the START STOP button once. To stop logging press the START STOP button, 'Stop Log?' will be displayed. Press the START STOP button again to confirm the log is to be stopped. The log MUST be stopped before the instrument can be switched off. LOGGING - 'PRINT EACH LOG AUTOMATICALLY' MODE The print button is disabled and the printing is automatically timed at set intervals selected by the user. If there is no paper loaded or the printer cover is open, 'Paper out' will be displayed, but the reading will still be stored. When a roll of paper is placed in the instrument and the printer cover is closed, the stored readings will be retrieved and printed in sequence. When 'log mode' is first set-up with the PC software the instrument will display 'ready'. All button functions are retained. The LIMITS/START STOP button is used to start and stop logging. To start logging press the START STOP button once. To stop logging press the START STOP button, 'Stop Log?' will be displayed. Press the START STOP button again to confirm the log is to be stopped. Once a log has been started the log MUST be stopped before the instrument can be switched off. All stored readings can be retrieved later using the Printing thermometer PC software. LOGGING - 'PRINT LOG SUMMARY USING PRINT BUTTON' MODE When the print button is pressed, the alarm limits and the number of alarm activations per input will be printed. If there is no paper loaded or the printer cover is open, 'Paper out' will be displayed for five seconds, but the reading will still be stored. In 'summary' mode all button functions are retained except the 'on/off' button. The LIMITS/START STOP button is used to start and stop logging. To start logging press the START STOP button once. To stop logging press the START STOP button, 'Stop Log?' will be displayed. Press the START STOP button again to confirm the log is to be stopped. The log MUST be stopped before the instrument can be switched off. 7

LOGGING - 'PRINT CURRENT TEMPERATURE USING PRINT BUTTON' MODE When the print button is pressed the current temperature is measured, and then a ticket is printed with this information along with any alarm activations. If there is no paper loaded or the printer cover is open, 'Paper out' will be displayed for five seconds, but the reading will still be stored. The LIMITS/START STOP button is used to start and stop logging. To start logging press the START STOP button once. To stop logging press the START STOP button, 'Stop Log?' will be displayed. Press the START STOP button again to confirm the log is to be stopped. The log MUST be stopped before the instrument can be switched off. LOGGING - 'PRINT LOG SUMMARY AND CURRENT TEMPERATURE USING PRINT BUTTON' MODE When the print button is pressed the current temperature is measured, the alarm limits and the number of alarm activations per input will be printed. If there is no paper loaded or the printer cover is open, 'Paper out' will be displayed for five seconds, but the reading will still be stored. The LIMITS/START STOP button is used to start and stop logging. To start logging press the START STOP button once. To stop logging press the START STOP button, 'Stop Log?' will be displayed. Press the START STOP button again to confirm the log is to be stopped. The log MUST be stopped before the instrument can be switched off. BATTERIES The PTR is fitted with a 3 cell rechargeable 3.6V NiMh battery pack. It is NOT user replaceable. Please return to the ETI Service Department for battery replacement. When the PTR power is low, the 'Lo Bat' segment of the LCD is lit. Print and feed operations are inhibited when 'Lo Bat' is indicated. Pressing the 'Print' or 'Feed' buttons will result in 'Recharge' being displayed for a short time in the display. RECHARGING THE PTR To recharge the PTR remove the rubber cap and plug the power cable into the socket on the right of the instrument. A flashing 'Charging' LED indicates that the device is being charged. A slow flashing LED (once/second) indicates normal charging. A fast flash rate (four times/second) indicates a charging fault (probably the batteries are too cold to charge). 8

The PTR should only be recharged in an ambient temperature between 5 and 40 C (41 and 104 F). Charge only with an ETI PTR power supply - 12V, 3.3A (40Watt).! Damage may occur if other power supplies are used. CONNECTING DEVICE TO THE PC To connect the PTR to a PC remove the rubber cap and plug the USB cable into the socket on the left side of the instrument. Use the Printing Thermometer PC software to customise PTR settings and ticket layout and to download stored reading. RESET If the PTR fails to respond, press the 'reset' button on the front of the instrument which is situated to the left of the display. CLEANING Clean only the outside of the instrument with a damp cloth or antibacterial wipe. PAPER LOADING PROCEDURE To reload the printer with a new paper roll, follow the steps below: 1. Un-clip the printer cover handle (fig 1). 2. Pull the printer cover handle until the cover un-clips. To avoid damage to the handle do not use excessive force (Fig 2). 3. Lift the lid until completely open (fig 3). 4. Remove any existing paper or the plastic tube from the previous roll. The easiest way to do that is to turn the PTR upside down, so the printer contents fall out (fig 4). 5. Prepare a new paper roll - remove the outer packaging and the holding sticker. Place into printer as shown in Fig 5. The glossy side of the paper should be against the printing mechanism 6. Push the paper fully into the printer housing (fig 6). 7. Close the lid, leaving a short strip of the paper roll protruding from the printer (fig 7). 8. Lock the cover by pressing shut. Push the printer cover handle shut (fig 8). 9

fig 1 fig 2 fig 3 fig 4 fig 5 fig 6 fig 7 fig 8 10

SPECIFICATION range -200 to 1372 C (-328 to 2051 F) operating temp range 5 to 50 C & 10 to 80 %rh resolution 0.1 C/ F (1 F above 1999.9 F) accuracy ±0.4 C ±0.1 % of reading battery Ni-MH 3.6V battery life approximately 500 prints from a full charge battery charging temp range 5 to 40 C battery charging cycles >500 charging power supply INPUT 100-240V - 47-63Hz 1-1A Max OUTPUT 12V, 3.3A (40Watt) sensor type thermistor connector type miniature thermocouple printer type thermal paper width 57 mm paper roll diameter Ø30 mm maximum print lines per roll 2000 approx. (Ø30 mm roll) display 12.7 mm LCD & 12 character alphanumeric dimensions 54 x 110 x 183 mm weight 630 grams IP rating IP2X If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 11

manufactured by Electronic Temperature Instruments Ltd Easting Close, Worthing, West Sussex BN14 8HQ tel: 01903 202151 fax: 01903 202445 email: sales@etiltd.com www.etiltd.com 13.06.14