INFORMATION TECHNOLOGY SYSTEMS SPDs FOR RJ CONNECTION. DEHNlink Surge arrester

Similar documents
INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation

INFORMATION TECHNOLOGY SYSTEMS

Surge protection for telecommunication connections

BLITZDUCTOR XTU Universal lightning current / surge arrester

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters

PT 3-PB-ST. Extract from the online catalog. Order No.:

INFORMATION TECHNOLOGY SYSTEMS

SPD for Data Protection. 47

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

Overvoltage Protection Devices

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

Overvoltage Protection Devices

Overvoltage Protection

Surge Protection for Surveillance Systems

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

R3&A Limited, Cobourg, ON

Overvoltage Protection Devices

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

2U Congestion Alert Rack Insert for UK

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Overvoltage Protection Devices

Lightning and Surge Arresters

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

Surge Protective Device

TT-UK5/ 24DC. Extract from the online catalog. Order No.:

Hazardous Area Protection

Surge protection for frequency converters

Surge Protection. tra Combinations. Surge Protection

Overvoltage Protection Devices

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA

Operating instructions. ProcessLine analogue module AC / / 2012

KeyTek ECAT. Expert Computer-Aided Testing for pulsed EMI immunity. Technical Specifications

Lightning and surge protection for electromobility

/60 ETITEC A 15/ /60 ETITEC A 15/440 Al/Fe connection*

Surge protection for gutter heating systems

Surge Protection Products for the small office/home office and professional grade

Systems which use a conventional POTS subscriber line to dial a compatible system and transfer digital data.

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

Technical Information HAW562

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

Reliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes.

DEHNsecure protects Direct Current Applications.

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.:

the data line series

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Residual Current Devices drcm Digital

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

Output Voltage* (nom.)(adjustable)

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Surge & Filter Protection Addressing your industrial power quality needs.

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

LINE 21 INTERNET ACCESS THROUGHOUT THE HOUSE

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overvoltage Protection

ECO 60 RANGE INTERNATIONAL DOMESTIC RANGE

Click Desktop Kit. Click Desktop Kit

Thermo Scientific ECAT

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

DBPApplication. PD Devices Ltd. Unit 1, Old Station Yard, South Brent, Devon. TQ10 9AL (0)

Installation Instructions

Output Voltage* (nom.)(adjustable)

A C O R N DECO

CYLINDRICAL Inductive Proximity Sensors

Lightning and surge protection for single-family houses

Type Code No. Weight Packaging [g] [pcs]

Bias-T for Cellular & PCS Networks

Single Source, Total EMC Test Solutions

Surge protection for information technology

Table of Contents. 1 General 1.1 Scope

Single Phase Systems-North American PC125/PC420 Series

Datasheet SPD II 1 Surge Protectors for AC Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations

TC-5921A Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines

Surge protection for transceiver systems

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

Technical Specification

NEW NEW NEW NEW NEW NEW Electrical specification ESP SL06 ESP SL15 ESP SL30 ESP SL50 ESP SL110 ESP SL TN

PRODUCT SPECIFICATION

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

PRODUCT INFORMATION. G6 Global Sensor. Beyond the standard Global sensor the economic way to business class

EFE300 / EFE400 EFE300M / EFE400M

MDP and FDB lightning barriers Safety for data and control systems in plants and industrial and potentially explosive

ETITEC - Lightning and Surge Arresters

SIN 158 Issue 3.6 May 2018

Overvoltage Protection

Manual Supplement. Manual Title: ESA609 Users Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13

MINI-PS AC/10-15DC/8

TC-5915A Shield Box. Features. High RF Shielding. Easy Opening/Closing of lid. EMI filters on all Data and DC lines

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

Transcription:

SPD X 2 No. 929 02 Line 7, V 2, ka Surge arrester Surface-mountable surge protective device for telecommunication systems Quick installation due to plug-in terminals Different types specified for interfaces Surge arrester for telecommunications terminal devices and telephone systems with RJ plug-in connection for surface mounting. Surge arrester for surface mounting in modern design. It protects especially modems and telephone systems with RJ plug-in connections. The plug-in connections allow for easy installation. Compared to conventional devices (... ECO), the different SPD units with...i type designation have an additional LED indication of the supply voltage. This helps to immediately recognise interferences on the installation. Furthermore, they provide a wide range of accessories like connecting cables or fixing material. Devices with and without operating state indication ISDN/I U C i sn ISDN can protect two terminal devices at the same time due to the integrated distribution function. The operating state indication is only illuminated, if the NTBA is also connected to the power supply and not in case of emergency operation (remote supply of telecommunication network operators). ISDN Wiring of LED on OK State LED off NT NT The operating state indication informs about the operating condition of the device. In case of faults, the connections and cables have to be checked. If no installation fault can be detected, the SPD has been overloaded and has to be replaced. State ISDN S O Interface Service Faulty Operating state indication www.dehn.de 22

929 02 ISDN/I 929 02 2 outputs Surge protection and LED indication for the remote supply included Energy-coordinated ISDN -wire protective circuit with additional protection and indication of the remote power supply. Dimension drawing SPD with two ISDN S 0 outputs (distribution function) and operating state indication (LED) of the remote supply voltage. No indication during emergency operation (supply from telephone system only). Connecting cable and mounting material included. Nominal voltage pa-pa U N Max. continuous operating d.c. voltage U c Max. continuous a.c. voltage U c Max. continuous d.c. voltage pa-pa U C Voltage protection level line-pg for I n C2 U p Voltage protection level pa-pa for I n C2 U p Voltage protection level line-line for 1 kv/µs C U p Voltage protection level line-pg for 1 kv/µs C U p Voltage protection level pa-pa for I n C2 U p Series impedance per line Bandwidth line-line Q V 0 V 7. V.2 V V 200 ma 10 ka 2. ka 0 V 00 V 180 V 17 V 00 V 100 V 1 ohm 2 MHz nf 1 pf -0 C...+80 C RJ / 2 x RJ Pinning /, / flat connector. mm Enclosure material polyamide PA. yellow Test standards IEC 1-21 connecting cable, mounting material Part No. 929 02 22 www.dehn.de

929 028 DLI TC 2 I DLI TC I DLI TC 2 I TC 2 929 028 Dimension drawing DLI TC I 2-stage protective circuit with overcurrent protection and system voltage indication of DLI TC 2 I. Protective device for analogue telephony or system telephony with operating state indication (LED). Protects even against a.c. current interferences. Compatible with pins of RJ11/12 plugs. Connecting cable and mounting material included. LED indicates supply voltage Protection against power crossing integrated Max. continuous operating d.c. voltage U c Max. continuous operating a.c. voltage U c Voltage protection level line-pg for I n C2 U p Voltage protection level line-line for 1 kv/µs C U p Voltage protection level line-pg for 1 kv/µs C U p Series impedance per line Bandwidth line-line DLI TC 2 I R 110 V 170 V 120 V 10 ma 10 ka 2. ka 20 V 00 V 20 V 00 V 10 ohms 10 MHz 0. nf 1 pf -0 C...+80 C RJ / RJ (compatible with RJ12) Pinning /, / (/, 2/ for RJ12) flat connector. mm Enclosure material polyamide PA. yellow Test standards IEC 1-21 connecting cable, mounting material DLI TC 2 I Part No. 929 028 www.dehn.de 22

DLI TC 929 081 DLI TC ECO RJ12 DLI TC ECO RJ12 - Denmark 929 081 Economical protection for 1 pair Modern design Using a high-capacity varistor makes decoupling to the gas discharge tube unnecessary. Protective device for analogue telephony or system telephony, RJ12 unit. Dimension drawing DLI TC Max. continuous operating d.c. voltage U c Max. continuous operating a.c. voltage U c Voltage protection level line-pg for I n C2 U p Voltage protection level line-line for 1 kv/µs C U p Voltage protection level line-pg for 1 kv/µs C U p Bandwidth line-line DLI TC ECO RJ12 R 10 V 170 V 120 V 200 ma ka 2. ka 80 V 00 V 280 V 00 V 10 MHz 0.7 nf 1 pf -0 C...+80 C RJ12 / RJ12 Pinning / flat connector. mm Enclosure material polyamide PA. yellow Test standards IEC 1-21 mounting material DLI TC ECO RJ12 Part No. 929 081 22 www.dehn.de

SPDs FOR BT JACK CONNECTION TC BT Surge arrester Surface-mountable protective device for telecommunication systems Quick installation due to plug-in terminals Device according to British Telecom requirements Surge arrester for telecommunications terminal equipment and telephone systems with BT plug-in connection for surface mounting. Surge arrester for telecommunications terminal equipment and telephone systems with BT plug-in connection for surface mounting. The device corresponds to requirements by Oftel NS/G/2/L/10000 on connections between a terminal point of a public telephone installation and any telecommunications terminal equipment. Fulfils BS1:1992, Appendix C, Category C-High and CCITT K17. www.dehn.de 227

TC BT SPDs FOR BT JACK CONNECTION 929 02 1 1 BT 929 02 2 2 Device according to British Telecom requirements Protection for all lines Energy-coordinated protective circuit for all pairs, free of leakage currents to earth. Dimension drawing Protective device for analogue telephony or system telephony in accordance with British Telecom requirements. Pluggable terminals for easy installation. Max. continuous operating d.c. voltage U C Voltage protection line-pg for I n C2 U p Voltage protection level line-line for 1 kv/µs C U P Voltage protection level line-pg for 1 kv/µs C U P Series impedance per line Bandwidth f G R 10 V 1 V 12 ma 10 ka ka 210 V 0 V 18 V 0 V.7 ohms 1 MHz 00 pf 10 pf -0 C...+80 C BT jack / BT jack Pinning 1/, 2/, / flat connector. mm Enclosure thermoplastic black Test standards IEC 1-21 connecting cable, mounting material Part No. 929 02 228 www.dehn.de