MADI.MONI. User s Manual. Version 1.1

Similar documents
EXBOX.AES. User s Manual. Version 2.0

MA2CHBOX.XL. User s Manual. Version 1.3

DirectOut Technologies

ANDIAMO 2. Hardware Guide. Version 2.1

DirectOut Technologies

POCKET BLUETOOTH SPEAKER WITH POWER CHARGER

HD 46 HME 46. Instructions for use

User Manual TL-TP70-HDC 70m HDBaseT Extender Set for HDMI, RS232 & IR All Rights Reserved Version: TL-TP70-HDC _160926

IPCB42501 / IPCB42551

BT6700. User manual. Register your product and get support at

User Manual TL-FO-HD. 4K Optical Fiber Extender. All Rights Reserved. Version: TL-FO-HD_160628

HP-101 HEADPHONE AMPLIFIER

Always there to help you Register your product and get support at BT6000 Question? BT6050 Contact BT6060 Philips User manual

Network Camera. Quick Guide DC-B1203X. Powered by

7032 Digital-Analog Multimeter

HX1 Bluetooth Stereo Headset

Bluetooth In-Ear Headphone Clip Light BT-X32

HMEC 250 Headset for general aviation

Size: 84 x 118.4mm * 100P

COMPACT LED DESK LAMP WITH LCD DISPLAY

TETRIS 2500 High Impedance Active Probe. Instruction Manual

User manual BT7900. Register your product and get support at

Skyrider Blue Kids Headphones

HDMI 1x4 SPLITTER. Ultra Slim Design Part Number: EVSLIM14 HDMI 1X4 ULTRA SLIM SPLITTER

NL-324BTR User manual (60706)

DirectOut Technologies

User Manual PUH4-H2. 4K HDMI Splitter 1x4. All Rights Reserved. Version: PUH4-H2_2016V1.2

Always there to help you. Register your product and get support at BT6000. Question? Contact Philips.

DVI Extender over single LC Fiber with TMDS video and EDID data.

Technical Documentation

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

POCKET MULTIMETER Model No: MM18

HuddlePod Air Big Audio

User Manual SP2-4K. 4K HDMI Splitter 1x2. All Rights Reserved. Version: SP2-4K_2016V1.0

Smartphone Docking Station with Speaker and Bed Shaker

B63/ NS MS. EtherNet/IP LINK

Do not attempt to service the unit yourself. Seek assistance from a qualified professional.

FengMi Wemax One Laser Projection TV

ODYS Xound Mini - 1 -

HBAC-30. Owner s Manual. Battery powered Guitar Amp

HP4 headphone amplifier. user manual

Portable CD/MP3 Stereo

User Manual. Stoltzen SHSP14 HDMI Splitter 1x4. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SHSP14_2016V2

W IRELESS8000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

CRASHER BLUETOOTH WIRELESS STEREO SPEAKER INSTRUCTION MANUAL

DS-1H05 Ethernet-over-Coax Extender. User Manual

AUDIO DELAY BOX WITH MICROPHONE INPUT AD-100M. Instruction manual.

TVAC25100 TVAC25110 User manual

EXTENDER DIGITAL-ANALOG AUDIO. pulseaudio1.com vanco1.com DIGITAL AND ANALOG AUDIO EXTENSION OVER A SINGLE CAT5E/6 CABLE

OPERATING INSTRUCTIONS POWERSMART 10 10,000 MAH PORTABLE POWER PLEASE READ BEFORE OPERATING THIS EQUIPMENT

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

P OCKET POWER 9000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

1. Product Description. 2. Product Overview

Product Manual. USB Charging Hub 10 Port Hi-Power 2.4A USB Charger Hub. Coolgear, Inc. Version 1.1 September 2017 Model Number: U2CHGRHUB10

AUD-220 Installation Guide

P OWERBUDS. The perfect accessory for anyone who wants to be truly wireless PLEASE READ BEFORE OPERATING THIS EQUIPMENT

HuddlePod Air DUO Dual Wireless Audio Pods Installation and Operation Manual

OLi POWA-5 Active Monitors

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

STYLISH LED DESK LAMP WITH DIFFERENT LIGHT MODES

Contents FOR YOUR SAFETY

Xemio-154 User Manual

Light-Source Mainframe

P OCKET POWER 6000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

User manual. Register your product and get support at Portable speaker SB500

HMEC Instructions for use

Manual. Polaron SMPS Watt power supply for chargers. No. S2024. Copyright Graupner/SJ GmbH

SHINE 3000 WITH FASHION CABLE

User manual. Portable speaker. Register your product and get support at SB500

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

PRE116/126. User Manual.

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

Tx Link. Quick Setup Guide. English. Connection module

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

Owner s Instruction Manual

English. BELTPACK User Guide DE-DPS BELTPACK

User Manual TL-TP70-HDIR. 70m Extender with ARC and IR. All Rights Reserved. Version: TL-TP70-HDIR_160708

Gavita Master Controller EL1

User Manual TL-TP100-HDC2

PLR BP1. Proloop Body Pack Induction Loop Receiver. Instructions For Use and Care

Always there to help you. Register your product and get support at AJ3275D. Question? Contact Philips.

Bluetooth Hands-Free Speaker Phone Custom Accessories 23685

SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER

Always there to help you. Register your product and get support at BT5580 BT5880. Question? Contact Philips.

Wireless Noise-Cancelling Over-ear Headphones. Instruction Manual GTCBTNC16

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

Thank you for your purchase USER MANUAL

5100 Series. Fiberlink. 10/100/1000 Base-T Etheret over one or two single mode or multimode fibers. User s Manual

Please read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c.

4KSP12-L. 4K HDMI Splitter 1x2. User Manual

Network Camera. Quick Guide DC-T3243HRX. Powered by

Druck DPI 620 advanced modular calibrator

MONOPRICE. Bluetooth Over-the-Ear Headphones with External Speakers. User's Manual. Model 15276

MusicMan Karaoke Microphone PRO BT-X35

USER MANUAL OVO MINI SPEAKER

CM/CS SERIES. Compact 100V amplifiers. Item ref: UK, UK, UK User Manual. CM/CS Series User Manual

User Manual SP2H2A-H2. HDMI 2.0 1x2 Splitter with Audio Breakout. All Rights Reserved. Version: SP2H2A-H2_2018V1.0

User Manual SP4H2-4K. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SP4H2-4K_2016V1.0

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

Transcription:

MADI.MONI User s Manual Version 1.1

Copyright All rights reserved. Permission to reprint or electronically reproduce any document or graphic in whole or in part for any reason is expressly prohibited, unless prior written consent is obtained from the DirectOut GmbH. All trademarks and registered trademarks belong to their respective owners. It cannot be guaranteed that all product names, products, trademarks, requisitions, regulations, guidelines, specifications and norms are free from trade mark rights of third parties. All entries in this document have been thoroughly checked; however no guarantee for correctness can be given. DirectOut GmbH cannot be held responsible for any misleading or incorrect information provided throughout this manual. DirectOut GmbH reserves the right to change specifications at any time without notice. DirectOut Technologies is a registered trademark of the DirectOut GmbH. DirectOut GmbH, 2017 page 2 of 40 MADI.MONI Manual - Version 1.1

Table of contents About This Manual 5 How to Use This Manual... 5 Conventions... 5 CHAPTER 1: Overview 6 Introduction... 6 Feature Summary... 6 How it works... 6 Applications... 7 CHAPTER 2: Legal issues & facts 8 Before Installing This Device... 8 Battery - Safety Instructions... 8 Defective Parts/Modules... 9 First Aid (in case of electric shock)... 9 Updates... 10 Conditions of Warranty... 10 Intended Operation... 10 Conformity & Certificates... 11 Contact... 12 Contents... 12 Accessory... 13 CHAPTER 3: Installation 14 Installing the Device... 14 Charging the battery... 17 CHAPTER 4: Operation 18 Introduction... 18 Global Control... 19 Signal Connections... 19 Battery... 20 Operating Principles... 21 Input Selection... 26 Sync... 26 Menu Structure... 27 Sample Rate... 28 Frame Format... 29 Channel Mode... 30 Amplitude... 31 Jitter... 32 Calibration BNC I/O...33 MADI.MONI Manual - Version 1.1 page 3 of 40

CHAPTER 5: Troubleshooting and Maintenance 35 Troubleshooting... 35 Maintenance... 35 CHAPTER 6: Technical Data 36 Index 37 page 4 of 40 MADI.MONI Manual - Version 1.1

About This Manual About This Manual How to Use This Manual This manual guides you through the installation and operation of the device. Use the Table of Contents at the beginning of the manual or Index Directory at the end of the document to locate help on a particular topic. You can access more information and latest news by visiting on the DirectOut website at www.directout.eu. Conventions The following symbols are used to draw your attention to: TIPS! indicate useful hints and shortcuts. NOTES! are used for important points of clarification or cross references. WARNINGS! alert you when an action should always be observed. MADI.MONI Manual - Version 1.1 page 5 of 40

CHAPTER 1: Overview CHAPTER 1: Overview Introduction Welcome to MADI.MONI, DirectOut s battery powered, mobile monitor and tester for MADI signals. MADI.MONI provides a coaxial MADI I/O for standard BNC cabling and a flexible SFP I/O to meet various connection standards by using SFP modules. Input signals are analysed (e.g. signal level, jitter, sample rate,...) and can be monitored via a headphone output. Feature Summary MADI Ports MADI Formats 1 x SFP (empty cage without module) 1 x coaxial BNC connectors 56/64 channel, 48k/96k Frame Sample Rates 44.1, 48, 88.2, 96, 176.4, 192 khz +/-12.5% USB Port Analysing Features Display USB 2.0 (B) plug for charging and firmware updates. Sample Rate, MADI Format, Signal Amplitude, Jitter Segment display to indicate channel / volume / signal level and 12 LEDs to confirm the integrity of the physical link, the format and settings of the MADI transmission at a glance. How it works The signal of the selected input is analysed. Analysis results are displayed on the device itself by individual LEDs for each parameter. Amplitude and Jitter are monitored via simple traffic light LEDs. The selected input can be monitored via headphones. Channel selection (mono or stereo pairs) and volume level are adjusted via two push buttons. The brightness of the display and the leds may be varied to match different lighting conditions. page 6 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 1: Overview Applications MADI.MONI can be used in numerous applications where MADI connections are used. Both quick integrity check of the physical link and monitoring the audio signal serve the aim of solid operating conditions in MADI environments. Typical applications include: ensuring stable signal connections detection of cabling issues (poor signal condition) line check of pre-installed cabling portable audio signal monitoring... MADI SFP I/O MADI BNC I/O Power Switch USB Phones Out Navigation Adjust Parameter MADI.MONI Manual - Version 1.1 page 7 of 40

CHAPTER 2: Legal issues & facts CHAPTER 2: Legal issues & facts Before Installing This Device WARNING! Please read and observe all of the following NOTE!s before installing this product: Check the hardware device for transport damage. Any devices showing signs of mechanical damage or damage from the spillage of liquids must not be operated. Do not use the device at extreme temperatures. Proper operation can only be guaranteed between temperatures of 5º C and 45º C and a maximum relative humidity of 80 %, non-condensing. The cabinet of the device will heat up. Do not place the device close to heating sources (e.g. heaters). Observe the environmental conditions. Do not dispose the device into fire, water or other liquids. Battery - Safety Instructions WARNING This device contains a rechargeable lithium-ion polymer battery. Observe the following safety instructions. Use only approved chargers and procedures. Improperly charging a cell or battery may cause the cell or battery to flame or damage. The battery may be exchanged only by service staff that has been authorized by DirectOut GmbH. The battery must be recycled or disposed of separately from general trash. Contact your DirectOut representative for exchanging the battery. Do not expose the battery to temperatures below 0 C or higher than 45 C. The battery is excluded from warranty claims. page 8 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 2: Legal issues & facts Defective Parts/Modules WARNING! This device contains no user-serviceable parts. Therefore do not open the device. In the event of a hardware defect, please send the device to your DirectOut representative together with a detailed description of the fault. We would like to remind you to please check carefully whether the failure is caused by erroneous configuration, operation or connection before sending parts for repair. First Aid (in case of electric shock) WARNING! Do not touch the person or his/her clothing before power is turned off, otherwise you risk sustaining an electric shock yourself. Separate the person as quickly as possible from the electric power source as follows: -- Switch off the equipment. -- Unplug or disconnect the mains cable. Move the person away from the power source by using dry insulating material (such as wood or plastic). If the person is unconscious: -- Check their pulse and reanimate if their respiration is poor. -- Lay the body down and turn it to one side. Call for a doctor immediately. Having sustained an electric shock, Always consult a doctor. MADI.MONI Manual - Version 1.1 page 9 of 40

CHAPTER 2: Legal issues & facts Updates DirectOut products are continually in development, and therefore the information in this manual may be superseded by new releases. To access the latest documentation, please visit the DirectOut website: www.directout.eu. This guide refers to firmware version 1.3. Intended Operation MADI.MONI is designed for analysis and monitoring of MADI signals (AES10). WARNING! No compensation can be claimed for damages caused by operation of this unit other than for the intended use described above. Consecutive damages are also excluded explicitly. The general terms and conditions of business of DirectOut GmbH are applied. Conditions of Warranty This unit has been designed and examined carefully by the manufacturer and complies with actual norms and directives. Warranty is granted by DirectOut GmbH over the period of two years for all components that are essential for proper and intended operation of the device. The date of purchase is applied for this period. Consumable parts (e.g. battery) are excluded from warranty claims. WARNING! All claims of warranty will expire once the device has been opened or modified, or if instructions and warnings were ignored. For warranty claims please contact the dealer where your device was acquired. page 10 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 2: Legal issues & facts Conformity & Certificates CE This device complies with the basic requests of applicable EU guidelines. The appropriate procedure for approval has been carried out. RoHS (Restriction of the use of certain Hazardous Substances) This device was constructed fulfilling the directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002/95/EC. WEEE (Directive on Waste Electrical and Electronic Equipment) Due to the directive 2002/96/EC for waste disposal this device must be recycled. For correct recycling please dispatch the device to: DirectOut GmbH, Leipziger Str. 32 09648 Mittweida Germany Only stamped parcels will be accepted! WEEE-Reg.-No. DE 123456789 MADI.MONI Manual - Version 1.1 page 11 of 40

CHAPTER 2: Legal issues & facts Contact Sales: DirectOut GmbH, Leipziger Str. 32, 09648 Mittweida, Germany Phone: +49 (0)3727 5665-100 // Fax: +49 (0)3727 5665-101 www.directout.eu Manufacturer: Leine-Weser-Labor GmbH, Brabeckstr. 121, 30539 Hannover, Germany Contents The contents of your MADI.MONI package should include: 1 x MADI.MONI 1 x USB cable 1 x product information To complete the delivery please download from the DirectOut website: www.directout.eu User Manual USB Serial driver Update Tool page 12 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 2: Legal issues & facts Accessory Two different optical SFP modules are available from DirectOut GmbH: Multimode SFP transceiver with LC connectors (No: DOICT0129) Singlemode SFP transceiver with LC connectors (No: DOICT0130) Specification of the optical SFP modules: SFP Multimode Singlemode Wavelength TX 1310 nm 1310 nm Wavelenght RX 1310 nm 1310 nm Distance 2 km 10 km Powerbudget (db) 11 db 12 db Protocols Fast Ethernet OC3/STM1 Gigabit Ethernet, Gigabit Fibre Channel Bandwidth from 100 Mbit/s 1.050 Gbit/s Bandwidth 155 Mbit/s 1.250 Gbit/s Laser FP FP Receiver Type PIN PIN Connector LC LC Wavelength TX min 1260 nm 1260 nm Wavelength TX max 1360 nm 1360 nm Wavelength RX min 1260 nm 1260 nm Wavelength RX max 1620 nm 1600 nm Transmit min - 19.00 dbm - 9.00 dbm Transmit max - 14.00 dbm - 3.00 dbm Receive min - 30 dbm - 21.00 dbm Receive max (Receiver overload) - 5.00 dbm - 3.00 dbm Temperature (min) 0 Celsius 0 Celsius Temperature (max) 70 Celsius 70 Celsius Type of DDM/DOM internal internal Extinction Ratio 8.20 db 9 db The modules support all analysing features of MADI.MONI. MADI.MONI Manual - Version 1.1 page 13 of 40

CHAPTER 3: Installation CHAPTER 3: Installation Installing the Device 1. Open the packaging and check that the contents have been delivered complete and undamaged. WARNING! Avoid damage from condensation by waiting for the device to adapt to the environmental temperature. Proper operation can only be guaranteed between temperatures of 5º C and 45º C and a maximum relative humidity of 80%, noncondensing. Ensure that the unit has sufficient air circulation for cooling. 2. Connect signal cable(s) for the MADI signals. 3. Connect the headphones for monitoring. 4. Turn on the power switch and check the battery condition. page 14 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 3: Installation While the device is booting the currently installed firmware is indicated in the display - e.g. firmware version1.2. TIP Use the DirectOut Release Map to match your DirectOut device with the latest firmware or software release. Link: http://www.directout.eu/upload/dokumente/dotec_release_map.pdf 5. Connect an USB cable to the USB port for charging the battery or firmware updates. NOTE!! To update the firmware an installed USB Serial driver (Windows ) and the Update Tool are necessary. The software and the installation instructions are available at www.directout.eu. MADI.MONI Manual - Version 1.1 page 15 of 40

CHAPTER 3: Installation 6. Installation of USB Serial driver download the USB Serial driver download the Installation Guide for USB Control -- Link: http://www.directout.eu/en/support/downloads/madi-moni.html follow the installation instructions in the Installation Guide for USB Control TIP! Keep any packaging in order to protect the device should it need to be dispatched for service. 7. Calibration of BNC I/O To assure accuracy of the measuring of a coaxial MADI signal, the BNC I/O shall be calibrated first - see Calibration BNC I/O on page 33. page 16 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 3: Installation Charging the battery The battery LEVEL led should be green. A yellow or red led indicates low level and requires charging the battery. To charge the battery switch off the device and and connect it to an external USB power supply or USB computer port. NOTE! If the battery is empty the device can be operated with an external USB power supply. The battery will only be charged when the device is switched off. MADI.MONI Manual - Version 1.1 page 17 of 40

CHAPTER 4: Operation CHAPTER 4: Operation Introduction This chapter describes the basic operation of the device. Note that throughout this manual, the abbreviation FS refers to sample rate or sample frequency. So, when dealing with scaling factors, the following sample rates can be written as: 44.1 khz or 48 khz = 1 FS 88.2 khz or 96 khz = 2 FS 176.4 khz or 192 khz = 4 FS page 18 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 4: Operation Global Control The power switch is on the side panel. LEDs on the top panel inform about battery level or charge state. Power 1 Switch Move slider to switch device ON or OFF. USB USB 2.0 socket (Type B) Connect here for charging the battery or firmware updates. Signal Connections MADI.MONI provides two MADI I/Os: coaxial BNC port SFP cage to connect other media carrying MADI signals, e.g. fibre (single mode/multi mode), different wavelengths etc. 1 2 1 2 BNC OUT / IN SFP 2 x BNC socket (coaxial) OUT: MADI output (64 ch), connect for MADI output signal here. IN: MADI input (64 ch), connect MADI input signal here. 1 x SFP cage* Insert SFP module here and connect MADI input/ output * empty cage, module not included in delivery - see Accessory on page 13. MADI.MONI Manual - Version 1.1 page 19 of 40

CHAPTER 4: Operation Battery The device can operate continously up to two hours with a fully charged battery. The battery level is indicated by the LEVEL led. Battery - Charge Battery - Level LED (green) - indicating charge status ON = charging battery OFF = no charge flashing (1,5 Hz) = NTC fault (temperature alarm) flashing (6 Hz) = battery defective LED (green / yellow / red) - indicating battery level while operation green = charged (> 3.5 V) yellow = needs charging soon (> 3,3 V) red = immediate charging required (< 3.3 V) NOTE! The operating time of the battery depends on the environmental conditions (temperature, type of installed SFP module). NOTE! See Charging the battery on page 17. page 20 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 4: Operation Operating Principles The device is operated via four push buttons, VOL/CH and MENU navigate the parameters. The two SET buttons ( ) are used for adjusting parameter values. Inputs Signal Format Signal Quality Navigation Volume Level Channel Selection Device Setting Level Meter Adjust Parameter Signal Format and Signal Quality inform about the signal state of the selected input. The values of Signal Quality are expressed by using different colors and combinations of the three LEDs ( traffic light ). The alphanumeric display monitors the signal level of the selected channel(s) for monitoring. Using the navigation buttons it can be toggled to temporary display of volume level or the selected channel for monitoring or the individual parameters of the device settings. On the following pages each parameter and its corresponding values are described. The Menu Structure on page 27 provides a basic overview of the device settings. MADI.MONI Manual - Version 1.1 page 21 of 40

CHAPTER 4: Operation VOL/CH MENU VOL CH MENU SET SET Display Push button Push for toggling between volume control and channel selection. Push button Push to enter and navigate the menu. LED (green) - indicates selection of volume control to adust level for headphones ON = Volume control enabled OFF = Volume control not enabled LED (green) - indicates selection of channel selection to adjust channel for headphones ON = Channel selection enabled OFF = Channel selection not enabled LED (green) - indicates selection of menu to adjust device settings ON = Menu settings enabled OFF = Menu settings not enabled Push button Push to decrease level / channel selection / parameter value. Hold for continous change. Push button Push to increase level / channel selection / parameter value. Hold for continous change. 2 x segment display Display content is explained on the following pages. The content of the alphanumeric display follows the navigation control. The device resumes to idle mode (= level meter) after about 10 seconds. NOTE! Volume Control and Channel Selection do not affect the MADI output signal. page 22 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 4: Operation Display - Volume control Display The adjusted volume level is indicated. The signal can be varied within a range of -74 dbfs to 0 dbfs in steps of 2 db. An additional boost up to 6 db can be applied. Headphone output muted. Volume Lowest volume level for headphone output. Highest volume level for headphone output. WARNING The use of headphones at high volume may harm your hearing. Display - Channel selection Display The selected channel (pair) is indicated. In stereo mode* odd numbers are indicated only. In mono mode* all channels are indicated. Values: 01 to 64 (example below) stereo mode = monitoring channels 05 (left) and 06 (right) mono mode = monitoring channel 05 (both sides) * the monitoring mode for the headphones output is adjusted in the device settings - see Display - Menu settings on page 24. MADI.MONI Manual - Version 1.1 page 23 of 40

CHAPTER 4: Operation Display - Menu settings Display The individual parameter of a device setting is indicated. Input Source BNC input is selected for analysis and monitoring. SFP input is selected for analysis and monitoring. Monitor Mode Mono mode, monitoring of a single channel, left and right are identical. Stereo mode, monitoring of a channel pair, odd number = left, even number = right Scaling factor for monitoring 1 (44.1 / 48 khz) Scaling Factor* Scaling factor for monitoring 2 (88.2 / 96 khz) Scaling factor for monitoring 4 (176.4 / 192 khz) Output Source SFP SFP MADI output follows the input selection (parameter <S>) SFP MADI output fed by SFP input SFP MADI output fed by BNC input * A 96k Frame input signal forces the scaling factor temporarily to 2 FS, overriding this setting until a 48k Frame input signal is resumed. Legend: c = cage = SFP, C = Channel = monitor channel mode page 24 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 4: Operation Display The individual parameter of a device setting is indicated. Output Source BNC BNC MADI output follows the input selection (parameter <S>) BNC MADI output fed by SFP input BNC MADI output fed by BNC input Display and led dim level 1 (dark) Display Brightness Display and led dim level 2 (moderate) Display and led dim level 3 (light) Display and led dim level 4 (strong) Display - Level meter (during idle mode) Display The signal level of the selected channels is indicated (left and right individually). LSB is used = audio is present Level Meter - 30 dbfs - 18 dbfs - 6 dbfs MADI.MONI Manual - Version 1.1 page 25 of 40

CHAPTER 4: Operation Input Selection Select between SFP I/O or coaxial BNC I/O by using the menu. SFP BNC LED (green) - indicating selection state of SFP input OFF = SFP I/O not selected ON = SFP I/O selected LED (green) - indicating selection state of BNC input OFF = BNC I/O not selected ON = BNC I/O selected Sync The device is clocked by the selected input signal. LOCK LED (green) - indicating input lock/sync state OFF = no signal detected at selected input ON = selected input is in sync FLASHING = selected input is locked but clock rate is out of range (< 28 khz or > 54 khz) page 26 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 4: Operation Menu Structure Press MENU to enter the menu and to navigate the parameters. Use the SET keys to alter the setting of the parameter. S<x> Input Source b = BNC c = SFP C<x> Monitor Mode 1 = mono 2 = stereo F<x> Scaling Factor 1 = 1 FS 2 = 2 FS 4 = 4 FS c<x> Output Source SFP S = selected input b = BNC input c = SFP input b<x> Output Source BNC S = selected input b = BNC input c = SFP input d<x> Display Brightness 1 = dim level 1 2 = dim level 2 3 = dim level 3 4 = dim level 4 Legend: c = cage = SFP, C = Channel = monitor channel mode MADI.MONI Manual - Version 1.1 page 27 of 40

CHAPTER 4: Operation Sample Rate The sample rate (FS) of the selected input is measured and indicated by two green leds. Base rates that deviate more than 0.1 % from the standard rates 44100 Hz or 48000 Hz are indicated by individual flashing codes of both leds. Code Meaning LED Code unlock FS < 44056 Hz FS = 44100 Hz ± 0.1 % both leds OFF 44.1 FLASHING green 48 OFF 44.1 ON 48 OFF 44145 Hz < FS < 47952 Hz both leds FLASHING green FS = 48000 Hz ± 0.1 % FS > 48049 Hz 44.1 OFF 48 ON 44.1 OFF 48 FLASHING green page 28 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 4: Operation Frame Format The frame format of the selected input is indicated by two leds. 96k Frame is available at 2 FS only while 48k Frame may be used at 1 FS, 2 FS and 4 FS. Thus a 48k Frame MADI signal needs the scaling factor to be adjusted manually for proper monitoring - see Display - Menu settings on page 24. Code Meaning LED Code 48k Frame 96k Frame 48k ON, green 96k OFF 48k OFF 96k ON, yellow NOTE! A 96k Frame signal forces the scaling factor temporarily to 2 FS. Once a 48k Frame signal is detected the set scaling factor is resumed. MADI.MONI Manual - Version 1.1 page 29 of 40

CHAPTER 4: Operation Channel Mode The channel mode of the selected input is indicated by two green leds. Deviations from the standard s channel counts of 56 or 64 channels (N) are indicated by individual flashing codes of both leds. Code Meaning LED Code channel count not constant N < 56 channels N = 56 channels both leds FLASHING alternately, green 56ch FLASHING, green 64ch OFF 56ch ON, green 64ch OFF 56 channels < N < 64 channels both leds FLASHING concurrently, green N = 64 channels N > 64 channels 56ch OFF 64ch ON, green 56ch OFF 64ch FLASHING, green page 30 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 4: Operation Amplitude If the BNC input is selected, the voltage of the MADI carrier is measured. Using the SFP input the module s DDM* signalling is utilized. The analysis results are indicated by traffic light leds. Code BNC SFP LED Code -- no SFP with DDM < 150 mv low power alarm LEFT FLASHING, red MID OFF RIGHT OFF < 300 mv low power warning < 600 mv ok (if SFP with DDM) < 800 mv high power warning LEFT ON, yellow MID OFF RIGHT OFF LEFT OFF MID ON, green RIGHT OFF LEFT OFF MID OFF RIGHT ON, yellow > 800 mv high power alarm LEFT OFF MID OFF RIGHT FLASHING, red * appropriate SFP Modules: see Accessory on page 13. NOTE! The AES10 spec requires the voltage of the carrier to be between 300..600 mv. NOTE It is advised to perform the calibration of the BNC I/O at periodic intervals - see page 33. MADI.MONI Manual - Version 1.1 page 31 of 40

CHAPTER 4: Operation Jitter The jitter of the MADI carrier of the selected input is analysed. The analysis results are indicated by traffic light leds. Code Measured Jitter LED Code very poor poor average good excellent better LEFT FLASHING, red MID OFF RIGHT OFF LEFT ON, yellow MID OFF RIGHT OFF LEFT OFF MID ON, yellow RIGHT OFF LEFT OFF MID ON, green RIGHT ON, green LEFT OFF MID OFF RIGHT ON, green page 32 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 4: Operation Calibration BNC I/O The input of the coaxial BNC port shall be calibrated at periodic intervals to assure accuracy of the measuring. Procedure: Connect a loop from BNC input to BNC output Press and hold VOL/CH and MENU buttons for 5 seconds until C1 is displayed. During the calibration process C2, C3 and C4 will be displayed. When the calibration is done the device returns to normal operation mode. Display Progress of calibration calibration process is initiated calibration phase 2 calibration phase 3 calibration done NOTE If the display stays at C1 check the cabling. MADI.MONI Manual - Version 1.1 page 33 of 40

CHAPTER 4: Operation This page is left blank intentionally. page 34 of 40 MADI.MONI Manual - Version 1.1

CHAPTER 5: Troubleshooting and Maintenance CHAPTER 5: Troubleshooting and Maintenance Troubleshooting To identify a possible defect with the device please consult the following table. If the fault cannot be resolved using these instructions, please contact your local DirectOut representative or visit support.directout.eu. Issue Possible reason Solution Device doesn t work. Rare flashing led codes after switch on. Optional SFP Module: Optical port does not work. Optional SFP Module: Analysis of Amplitude does not work No signal at the output port. No signal at the output port. Battery discharged. Low power - battery discharged. Optic is dirty. SFP Module does not support this feature. Signal cable defective. Connections (input / output) are mixed up. Check that the power supply switch is off and plug the device to a matching charging device using the USB connection. Check led BATTERY- CHARGE. Check that the power supply switch is off and plug the device to a matching charging device using the USB connection. Check led BATTERY- CHARGE. Use an air supply to carefully remove any dust. Never use objects for cleaning. Use appropriate SFP module. See Accessory on page 13. Exchange the signal cable. Check the connections and change the cables if necessary. Maintenance To clean the device, use a soft, dry cloth. To protect the surface, avoid using cleaning agents. The device should be switched off during the cleaning process. MADI.MONI Manual - Version 1.1 page 35 of 40

CHAPTER 6: Technical Data CHAPTER 6: Technical Data Dimensions Width: 120 mm Height: 90 mm Depth: 28 mm Weight: about 200 g Battery Nominal Capacity: 1100 mah (typical) Nominal Voltage: 3.7 V Charging via USB connection (max. 5 V) Charging Current max. 500 ma Environmental Conditions Operating temperature +5 C up to +45 C Relative humidity: 10% - 80%, non condensing MADI Port BNC coaxial 2 x BNC socket (input / output) Impedance: 75 Ω 0.3 V up to 0.6 V (peak to peak) MADI Port SFP 1 x SFP (empty cage without module) optional SFP Modules: see Accessory on page 13 Headphones Output 3.5 mm TRS jack, mono/stereo Sample Rate 32, 44.1, 48, 88.2, 96, 176.4, 192 khz (+/- 12.5 %) MADI Format (I/O) 48k Frame, 96k Frame 56 channel, 64 channel USB 1 x USB 2.0 socket (Type B) for charging and firmware updates page 36 of 40 MADI.MONI Manual - Version 1.1

Index Index A Accessory... 13 Amplitude... 31 B Battery Charging... 17 LED codes... 20 Safety Instructions... 8 C Calibration BNC I/O... 33 Channel Mode... 30 Conformity & Certificates CE... 11 RoHS... 11 WEEE... 11 Contact... 12 Contents... 12 Conventions... 5 D Defective Parts/Modules... 9 Display Channel selection... 23 Level meter... 25 Menu settings... 24 Volume control... 23 J Jitter... 32 M Menu Structure... 27 O Operating Principles... 21 S Sample Rate... 28 Scaling Factor... 18 SFP Modules... 13 Support... 35 T Troubleshooting... 35 U Updates... 10 W Warranty... 10 E Environmental Conditions... 14 F Feature Summary... 6 Firmware... 15 First Aid... 9 Frame Format... 29 I Intended Operation... 10 MADI.MONI Manual - Version 1.1 page 37 of 40

NOTE page 38 of 40 MADI.MONI Manual - Version 1.1

NOTE MADI.MONI Manual - Version 1.1 page 39 of 40

DirectOut GmbH Leipziger Strasse 32 T: +49-3727-5665-100 09648 Mittweida Germany F: +49-3727-5665-101 www.directout.eu