Standards Update Notice (SUN) Issued: January 11, 2016

Similar documents
Standards Update Notice (SUN) Issued: April 25, 2017

Standards Update Notice (SUN) Issued: August 11, 2017

Standards Update Notice (SUN) Issued: July 28, 2017

File E Project 90ME March 12, 1991 REPORT

UL TEST REPORT AND PROCEDURE

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

E A54-UL 2012-AUGUST-29 XP POWER L L C SUITE E DYER RD SANTA ANA CA 92705

UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL

File E Project 05NK Issued: Revised: REPORT CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD)

UL TEST REPORT AND PROCEDURE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

PV Rapid Shutdown device

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

UL TEST REPORT AND PROCEDURE

Test Report S

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010

UL TEST REPORT AND PROCEDURE

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

C E R T I F I C A T E O F C O M P L I A N C E

Bulletin Installation of solar photovoltaic systems Rules , , , , and

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

UL TEST REPORT AND PROCEDURE

Power Supply Installation

File E Project 00SC September 27, 2000 REPORT COMPONENT - POWER SUPPLIES, MEDICAL AND DENTAL EQUIPMENT

File E Project 01ME October 15, 2001 REPORT

UL TEST REPORT AND PROCEDURE

File E Project 08NK October 2, 2009 REPORT SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX

C E R T I F I C A T E O F C O M P L I A N C E

SECTION DISCONNECT SWITCHES

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Microinverters And The Solar Industry


UL TEST REPORT AND PROCEDURE

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

hp uninterruptible power system r12000 xr models installation instructions

File E Project 91SC COMPONENT POWER SUPPLIES INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT

UL TEST REPORT AND PROCEDURE

EMMS-T A00 SIERS. Siemens integrated electrical racking system instruction manual. usa.siemens.com/mvswitchgear

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

WELDTRON PIPELINER Troubleshooting problems with the Pipeliner Remote Amp Control.

UL TEST REPORT AND PROCEDURE

Protection against electric shock

GROUND FAULT CIRCUIT INTERUPTERS

UL TEST REPORT AND PROCEDURE

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

PS/IO Circuit Board Retrofit

Instructions for Operation of S&C Test Accessory Catalog Number TA-2669

Emery County Senior Center Green River 06/07

CENTRAL MARKS DEPARTMENT-III

Site Preparation CHAPTER

UL TEST REPORT AND PROCEDURE

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

More Questions from Inspectors Numerous PV Systems Pose Issues

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

File E Project 93ME39941, Issued: November 29, 1993 New: April 26, 2006 REPORT COMPONENT - POWER SUPPLIES. For Use In

UL2930 Healthcare Facility Outlet Assemblies UL1449 Heavy Duty Surge Protection Devices. Wiring Device-Kellems

Please use the Q & A utility to ask us any questions concerning the material being presented.

Power Supply (48Vdc, 2.5A)

SAVE THESE INSTRUCTIONS

1510 MOTOR CONTROLLERS

COMPACT LED CONVERTERS 48 V

CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS

C E R T I F I C A T E O F C O M P L I A N C E

M E M O R A N D U M I.S.

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

UL TEST REPORT AND PROCEDURE

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

Electrical Components and Equipment for General Use Self Inspection Checklist

Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP)

C E R T I F I C A T E O F C O M P L I A N C E

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

Colour Code Red = Fail/Major Fault Amber = Improvements Required Green = Pass

UL TEST REPORT AND PROCEDURE

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

Electrical Specifications

File E Project 11SC May 15, 2012 REPORT COMPONENT DRIVERS FOR LIGHT-EMITTING-DIODE ARRAYS, MODULES AND CONTROLLERS

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

EMOSAFE EN-100 Network Isolators for PCB assembly

PERMANENT DOCUMENT. Annex AU to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement)

Installation Instructions

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

COVER PAGE FOR TEST REPORT

White Paper. UL Standards for Power Control System Equipment

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

10A Micro-Ohmmeter Model 6240

Installation Job Aid for Ethernet Routing Switch 3600 Series

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

Installation Guide for America Solar Wholesale Photovoltaic Modules

Transcription:

Standard Information Standard Number: UL 962A Standard Name: Furniture Power Distribution Units Standard Edition and Issue Date: 3 rd Edition Dated September 29, 2014 Date of Revision: September 8, 2015 Date of Previous Revision to Standard: 3 rd Edition Dated September 29, 2014 Effective Date of New/Revised Requirements Effective Date (see Schedule below): November 30, 2016 Impact, Overview, Fees and Action Required Impact Statement: A review of all Listing Reports is necessary to determine which products comply with new/revised requirements and which products will require re-evaluation. NOTE: Effective immediately, this revised standard will be exclusively used for evaluation of new products unless the Applicant requests in writing that current requirements be used along with their understanding that their listings will be withdrawn on Effective Date noted above, unless the product is found to comply with new/revised requirements. Overview of Changes (Specific details of new/revised requirements are found in table below): Luminaires and wireless charging pads incorporated with furniture power distribution units. FPDUs with batteries and low voltage circuits. Clarification of requirements for receptacle outlets. Addition of requirements for splicing wire connectors. Correction of requirement in paragraph 46.1. If the applicable requirements noted in the table are not described in your report(s), these requirements will need to be confirmed as met and added to your report(s) such as markings, instructions, test results, etc. (as required). Schedule: So that production of products bearing Listing Marks will not be interrupted, the following schedule of approximate dates has been established to ensure Listing Reports are found compliant by Effective Date: - March 30, 2016 = 8 Month Report Review Intertek will review all Reports. Update if compliance is verified or issue Findings Letter/Quote for any re-evaluations needed - May 31, 2016 = 6 Month Quote Cut-off Quotes returned for necessary re-evaluations - October 31, 2016 = 30 Day Warning Client advised of all non-compliant Reports to be Suspended - November 30, 2016 = Effective Date ATM Suspended for all non-compliant Reports Fees: An initial review of Listing Report (s) will be covered by a direct billing project and will be invoiced at not more than $1000 per report. Client Action Required: Information To assist our Engineer with review of your Listing Reports, please submit technical information in response to the new/revised paragraphs noted in the attached or explain why these new/revised requirements do not apply to your product (s). Standards Update Notice MY/JP SUN Template 042214 Page 1 of 5

Current Listings Not Active? Please immediately identify any current Listing Reports or products that are no longer active and should be removed from our records. We will do this at no charge as long as Intertek is notified in writing prior to the review of your reports. Description of New/Revised Technical Requirements -- -- Luminaires and wireless charging pads incorporated with furniture power distribution units. 1 Info Scope 1.1.1 A cord and plug connected product as described in 1.1 with less than three receptacle outlets and provided with a Luminaire is covered under the Standard for Portable Electric Luminaires, UL 153. 1.8 A product that has a battery backup feature or other uninterruptible power supply equipment located in the Primary Circuit shall comply with the applicable requirements in the Standard for Uninterruptible Power Supply Equipment, UL 1778. 2.1 Info Components 2.1.5 A FPDU that incorporates a LED Luminaire and LED components and subassemblies shall comply with the applicable requirements of the Standard for Light Emitting Diode (LED) Equipment for Use in Lighting Products, UL 8750. 12 Info Power-Supply Cord Guide to construction and performance requirements for furniture power distribution units Table 12.1 A FPDU incorporating an LED Luminaire shall be provided with supplementary OCP as shown in the column Maximum Supplementary OCP rating a,d (A). The FPDU shall also be provided with instructions as indicated in 48.1. 14 Info Supplementary Protection New clause added (requirements previously described under table 12.1); 14.11 Info A FPDU incorporating LED Luminaires or wireless charging circuits shall be provided with supplementary overcurrent protection. See Table 12.1. 48 Info Details (Instructions) New clause added (requirements previously described under table 12.1); 48.1 Info As required in Table 12.1 footnote (i), the instructions shall include the following information or equivalent A Furniture Power Distribution Unit provided with auxiliary lighting features is not for permanent installation. Do not remove the plug for permanent connection to the electrical system. Standards Update Notice MY/JP SUN Template 042214 Page 2 of 5

-- -- FPDUs with batteries and low voltage circuits 18 Info Spacings 18.4 18.5 18.6 18.7 18A Info All uninsulated live parts connected to different circuits shall be spaced from one another as though they were parts of opposite polarity, in accordance with the requirement in 18.6, and shall be investigated on the basis of the highest voltage involved. An electrically energized screw head or nut on the underside of an insulating base shall be prevented from loosening. In multicomponent equipment, the spacings from one component to another, from any component to the enclosure, or to other uninsulated dead metal parts excluding the component mounting surface, are based on the maximum voltage rating of the complete equipment and not on the individual component ratings. The inherent spacings within an individual component are investigated on the basis of the voltage used and controlled by the individual component. Spacings between metal oxide varistors, capacitors, and other components shall comply with the minimum spacing requirements in Table 18.1. Spacings at a fuse and fuseholder are to be measured with a fuse in place that has the maximum standard dimensions for the rating, and such spacings are to not be less than those specified in Table 18.1. Clearance and Creepage Distances Isolated Secondary Circuits 18A is an alternative approach to meeting the spacing requirements described in section 18.1 Standards Update Notice MY/JP SUN Template 042214 Page 3 of 5

20 Info Separation of Circuits Additions to existing requirements are underlined and deletions are shown lined out below. Electrical wiring of a FPDU and wiring of communication circuits shall be separated by a permanent barrier or a 2 in (50.8 mm) spacing including lead dress. A FPDU employing connection to telephone communication, data communication or incorporating isolated secondary circuits, shall be provided with a barrier, physically secured by means other than friction, that separates the ac power circuit conductors from the conductors of the other circuits. Bonding of the equipment grounding conductor and the referenced conductors of the telecommunication circuits is permissible. 20.1 Exception No. 1: A barrier is not required between conductors that are separated by a minimum spacing of 2 inches (50.8 mm), including lead dress. Exception No. 2: Conductors that are suitably insulated for the maximum AC power circuit voltage involved are not required to be separated from the AC power circuit conductors, when breakage or loosening of a conductor at a terminal in either circuit cannot result in contact between uninsulated parts of one circuit and uninsulated or inadequately insulated parts of the other circuit. 21A 21A.1 21A.2 Supplement SA SA1 Info Exception No. 3: For conductors other than AWM (traces on a printed-wiring board, terminals mounted on insulating blocks, and the like), the minimum separation between communication circuits and the AC power circuits shall be in accordance with Table 18.1. Low Voltage Charging and Isolated Secondary Output Circuits A charging circuit and/or isolated secondary output circuit provided in a FPDU, shall comply with the Standard for Class 2 Power Units, UL 1310 or the Standard for Information Technology Equipment Safety - Part 1: General Requirements, UL 60950-1 for Limited Power Circuits. A FPDU provided with a wireless charging circuit shall comply with the Standard for Induction Power Transmitters and Receivers for Use with Low Energy Products, UL 2738. FURNITURE POWER DISTRIBUTION UNITS INCORPORATING BATTERIES This new section includes new construction requirements, performance test requirements, markings, and instructions for FPDUs incorporating batteries (see standard for section details). Scope SA1.1 The requirements of this Supplement address FPDU s incorporating nonrechargeable (primary) and rechargeable (secondary) batteries not exceeding 60Vdc, 20 Ah. Standards Update Notice MY/JP SUN Template 042214 Page 4 of 5

-- -- Clarification of Requirements for Receptacle Outlets 12.1.9 Info The cord connectors that are employed in a FPDU shall be molded-on or assembled-on to the flexible cord. The cord connector shall be the grounding type and shall comply with the requirements in the Standard for Attachment Plugs and Receptacles, UL 498or the Standard for Cord Sets and Power Supply Cords, UL 817. -- -- Addition of requirements for splicing wire connectors 21 Info Grounding Additions to existing requirements are underlined; 21.1.4 Info Connections in the equipment-grounding conductor path from the receptacle grounding contact to the equipment-grounding conductor of the power-supply cord shall be welded, bolted, mechanically secured and soldered, or made by equivalent positive means. A quick-connect, or similar friction-fit connector shall not be used in the grounding conductor path. Exception: A splicing wire connector that complies with the Standard for Splicing Wire Connectors, UL 486C and the Standard for Grounding and Bonding Equipment, UL 467 is acceptable within the ground path when located within the electrical enclosure and used in accordance with its ratings. 21.2 Info Bonding Additions to existing requirements are underlined; A bonding conductor shall not be spliced. 21.2.8 Info Exception: A splicing wire connector that complies with the Standard for Splicing Wire Connectors, UL 486C and the Standard for Grounding and Bonding Equipment, UL 467 is acceptable within the bond path when located within the electrical enclosure and used in accordance with its ratings. -- -- Correction of requirement in paragraph 46.1. 46 Info Details (Ratings) A FPDU shall be rated in maximum AC current and AC voltage. The voltage rating 46.1 Info shall not be higher than 250 V. The current rating shall not be higher than 16 A 20 A, the ampacity of the power-supply cord, nor the highest rating of the overcurrent protective device that is provided. CUSTOMERS PLEASE NOTE: This Table and column Verdict can be used in determining how your current or future production is or will be in compliance with new/revised requirements. Standards Update Notice MY/JP SUN Template 042214 Page 5 of 5