AHD-RB6 Electronic Circuit Breaker (ECB) Type C

Similar documents
Accessories for Vessels

GPM500 Generator Protection Module

The LED display (1) turns green when the load is switched on.

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

VersaPoint I/O Module

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

RT4B-110V/12A RECTIFIER

QUINT-PS/ 1AC/24DC/20/CO

picture 1: Device components

RT4F-120V/20A-WAC RECTIFIER

RT4F-110V/25A RECTIFIER

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

8B0C0320HW General information. 2 Order data. 3 Technical data 8B0C0320HW

L05065 LED Driver 150W, 24-60Vdc, mA L1M1MLT400S-150E

4 CHANNEL UNIVERSAL DIMMING ACTUATOR

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

RM4JA32MW current measurement relay RM4-J - range A V AC DC

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

NMEA Expander. Operation And. Installation Manual

EthernetConnect and IP/Analog Fiber Accessories POWER SUPPLIES, RACK CHASSIS WITH INTERNAL POWER SUPPLY

Dimmers - Clipsal by Schneider Electric

QUINT-PS/ 1AC/24DC/ 5

Product and functional description

L05060 LED Driver 100W, Vdc, ma

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

QUINT-BUFFER/24DC/24DC/40

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

Product and functional description

DC POWER SUPPLIES DNX 110/220 V

DPO A4. Description. Module with 4 digital outputs. Datasheet

Communications & Networking

Bus Connection Unit 560BCU04

Non-communicating room controllers

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

RT4F-48V/50A-WAC RECTIFIER

GE Energy Connections Grid Solutions MMLZ. Technical Data Sheet Auxiliary Modules. Publication reference: MMLZ/EN TDS/B

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

RM4JA01F current measurement relay RM4-J - range ma V AC

Output Voltage* (nom.)(adjustable)

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

ATV1200A kv kva

E-Learning, DC drives DCS800 Hardware D5 D7, part 2

Contact protection relay

Non-communicating room controllers

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range

MTeC - EPT202 Digital thermometer Messko

Control different load types with one device

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Avtec, Inc. Lighting Systems

Q9 ASD LOW VOLTAGE DRIVE

Operating and mounting instructions

Communicative controller for VAV systems

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

Data sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.

RT12-240V/2.4kW Rectifier Specification

LED Dimmer LED-08T

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

12/24V LED Dimmer Remote Controllable

Manual and application description KNX/EIB LED driver V2.0

Output Voltage* (nom.)(adjustable)

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

OTi DALI 75/ /700 D LT2 UF L

Zelio Control-modular measurement and control relays 1

L05055 LED Driver 60W, Vdc, mA L05059 LED Driver 60W, Vdc, mA L1M S-60E L1M S-60E

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Overvoltage Protection

Product Overview. PowerFlex 520-Series AC Drives Feature. Modular Design. Packaging and Mounting. Optimized Performance

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ISIO 200. Binary Input/Output (I/O) terminal with IEC interface

Safety Technique. SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

MOTUS ContactronControl. Less is more.

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

ES Energy Saver Product Ranges 90Amp 6000Amp

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line

AC-DC Converter REC K10

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Wireless DMX Control. Show Performer DMX Controller. Stage Desk 48 DMX Controller

BRC SERIES 20kW High Voltage Power Supply

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

16-Channel Digital Input Termination Card 24Vdc

Rev Operating Instructions Busch-Dimmer. Potentiometer U-101

Transcription:

AHD-RB6 Electronic Circuit Breaker (ECB) Type C Nominal current up to 16 A per channel / 28 A for connected channels (Slave channel) Bipolar switching of all channels Operating voltage 24 V DC (-30%/+25%) 6 channels output; 6 channels input, e.g. for light switches, level switches or other contacts, independently configurable Free configuration with the Böning DeviceConfig tool Separate current measurement for each channel (< 50mA resolution) Visualization of all relevant data e.g. on our displays possible Dimmer function for lighting control Staus LEDs for each channel Watchdog supervision Wire break supervision, undercurrent and overcurrent detection 3-step current limit setting with rotary switches Maximum security by redundant switch circuits Protection against overvoltage, shortcircuit, overload and overheating Easy and cost-effective installation with patch cables for CAN bus Soft switching of lamps for longer durability (pulse width modulation) Grouping of channels, e.g.for lighting control Programmable lag time for outputs Operating temperature range allows installation in any location, including engine rooms Significant reduction of cabling and costs due to decentralized installation Stand-Alone device operation possible with pushbuttons / switches Connection to NMEA 2000 network (upon request) Tripping Characteristic Type C

Protection Switching - Dimming The switches can be set into the following positions (see also Device Overview): Pos. 1: ON (Override function, the controller is switched to bypass; the output is switched on (hardware), even with failure of the electronic system). The AHD-RB6 is an electronic circuit breaker (ECB) for six channels with CAN-Bus connection for connecting, controlling and monitoring of electrical loads up to 16 A / 24 V DC per channel. The device switches all load circuits bipolar. If required, four channels on each card can be connected to two channels increasing the nominal current to 28 A for each double channel. The maximum current can be separately adjusted for each channel to 6.3 A, 10 A or 16 A, providing according protection for all cables with corresponding dimensioning. The terminals for the power input can handle a current of 125 A. The current of each channel is measured separately, enabling the AHD-RB6 to be used for example as a power management device.the recorded current values can be evaluated over CAN bus and visualized for example on our displays and monitors. In case of a CAN system or processor failure each channel can be manually set with the built-in switches without affecting the safety function. Pos. 2: AUTO (the output is switched and supervised by the controller). Pos. 3: OFF (Override function, the controller is switched to bypass, the output is switched off and secured from being switched on over the CAN bus). The switches 2 and 6 incorporate an additional switching position (SL 1 / SL 5) for connecting channels 1 / 2 and 5 / 6 for increased output currents (Slave operation). Each channel can separately be configured for dimming of lighting, where a different diming value can be assigned to each channel over CAN bus (display) or by pushbutton. If a pushbutton is used for dimming, a short pressing of the button switches the lighting on or off, while pressing and holding the button activates the dimming function (dimming from bright to dark or from dark to bright, respectively). Two AHD-RB6 in a row can serve as security switches: This is best explained in a short example. Channel 1 of the first AHD-RB6 controls a cooler fan. If this channel is switched off, channel 1 of the second circuit breaker, controlling the backup cooler fan, is automatically switched on, ensuring a constant cooling.

Tripping Characteristics of the AHD-RB6 Type C X axis: multiples of nominal current. Y axis: Tripping time without prior charge, that is the current was 0.0 Ampere. The limit values according to IEC 60898-1 for type C circuit breakers are marked with red spots. The AHD-RB6 limits the short-circuit current to a maximum value of 180A for each channel (typically 120A) with a release time of 1.4 milliseconds. Fuses in the incoming circuit therefore will never have to handle a load of more than 180A. According to IEC 60898-1 the AHD-RB6 shows the characteristics C for direct current voltage (DC).

Device Overview Overview: 1 Power LED Mains 2 Power LED Logic 3 Rj45-Interface (CAN) 4 Terminal block (pluggable) 5 Rotary switch device address 6 Rotary switch current limit (see also table below) 7 Function Selector 8 Status LED (separately for each channel) 9 Terminal block output 10 Power supply input terminal block The rotary switch for the current limits has three positions: Rotary Switch configuration: 1 10 A 2 6,3 A 3 16 A

Dimensions

Technical Information Art.-No. 14708 Operation voltage Current consumption (Device electronics) 24VDC (+30% / -25%) max. 220mA Installation: Circuit breaker resolution Module housing, installation directly on mounting rail TS 35 < 50mA Dimensions W x H x D: 219 x 125 x 70mm Switching voltage = power supply Weight: 1,6kg Nominal current 16A per channel Operating temperature: -30 C +70 C Maximum load 6 x 16A = 96A / 24VDC Storage temperature: -50 C +85 C Cable cross section Terminal block 4mm² Degree of protection: IP 20 Cable cross section main power supply 35mm² Interfaces - RJ45 - Terminal block Böning Automationstechnologie GmbH & Co. KG Am Steenöver 4 D-27777 Ganderkesee E-Mail:info@boening.com www.boening.com PaB-1087 V9 Rev. Apr. 8 th, 2014 Texts and Illustrations not binding. Changes may be made due to technical improvements.