USER GUIDE PEL / PEL-M

Similar documents
USER GUIDE PEL 8K / PEL 8K-M

USER GUIDE TEx LU / TEx-M

USER GUIDE TEHR LU / TEHR-M

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Carbon Monoxide Sensor - ModBus

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

HLS34 Modbus FCU/VAV Controllers installation instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

MOD-RI Room Interface Modules with Modbus

BQ & BQ370-01N MODBUS ANALOG INPUT DEVICE USER MANUAL

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

PCD DIGITAL Differential pressure probe

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

Version 1.0c May 6, 2010 ATK3

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

Gastrack Gas Analyser

FCU-MULTI Modbus Fan Coil Unit Controller

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

KTA-250 Anemometer Alarm Card

Trident and Trident X2 Digital Process and Temperature Panel Meter

USER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26

T2314, T2414. Instruction Manual

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

Golander Peristaltic Pump MODBUS Communication Instruction

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 2 Art. no.:

DIFFERENTIAL PRESSURE TRANSMITTER with MODBUS interface Optional Input module

DP DP2500 DP0250

ATK3 I/O Module (Modbus Slave)

CDD ModBus Carbon Dioxide Detector

RXTP ROOM TEMPERATURE

Communicative controller for VAV systems

RS485 MODBUS Module 8AO

DPA+ LCD. Application. Types Available. Differential Pressure Transmitter. Datasheet

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

TOTALFLOW Technical Bulletin 113

Uponor Smatrix Move PRO Controller X-159 Modbus RTU interface

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

EE160 - Humidity and Temperature Transmitter for HVAC Applications

Modbus Communications Board

Installation Guide. Section 1 - Room... pg 03. Section 2 - Duct... pg 23. I-CDD3_Modbus Installation. Modbus Gas Transmitters I-CDD3 Series

Modbus Communications Board

Gas and Air Sensors. Product Specification. CO 2 Engine K30. Sensor Module and OEM Platform. Document PSP 110. Rev 4. Page 1 (11)

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Wireless Transducer MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

19.Configure HMI as a MODBUS Server

Hydrostatic filling level sensor HFB C4 / R / MD

T2314, T2414. Instruction Manual

RS-FS-N01 Wind speed transmitter user's Guide (485type)

CuteLine AIN8 UI - Voltage Current. Manual

Product Specification for SAB-S-MODBUS

Tango. alpha nea. Thermometers and controllers with digital communication - Series AM

HRT-710. User s Manual Version HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1

HART 710. User s Manual Version HART-710 User Manual (Version 1.00, July/2010) PAGE: 1

RTD-W Installation Instructions

Installation manual CF8-W-Disp-AL

Signal Isolators & Conditioners

Supply Voltage V dc Supply is fully isolated internally, and protected against transients. Internal power modules are CE certified.

Specification Sheet For electronically commutated motors

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

H7625A, H7635A Humidity/Temperature Sensors

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

TRANSDUCER T4311, T4411

The benefits are ease of set-up, more data available for the user from the drive, fast control, and state of the art technology.

asense m III in industrial wall mounted housing / CO sensor with built-in general purpose controller

Level monitoring system NT 3500 Technical information / Instruction manual

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

RTD-NET Installation Instructions

lindab we simplify construction UltraLink Technical information

Technical Specificaions. kwh Energy Meter

Modbus Manual Version Modbus Manual for PF4/5

USER S GUIDE. EE211 - Heatead Humidity and Temperature Transmitter for High Humidity Applications GENERAL ASSEMBLY SCOPE OF SUPPLY CAUTION

FT2 View Instruction Manual

CuteLine AIN8 Temperature. Manual

Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD

SC2004MBS 20x4 Characters MODBUS RTU Slave LCD

Rev 1.3, Air-Farm User Manual. CO2 / Temperature / Humidity Transmitter

HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR

High Voltage DC Meter

0-25% (O 2 % version) 0-300mbar (ppo 2 version) 0.01% / 0.1mbar (Digital Outputs) 0.01V (0-5V Analogue Output) Please follow all safety instructions

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Modbus Protocol For FTS/FTM 3x&8x

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

Warranty. Warning. Copyright. Contact Us

F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide

RXTH DUAL ROOM SENSOR / SWITCH

CDD4 Duct Carbon Dioxide Transmitter

VAT series controller and transmitter. Manual

HIGH-VOLTAGE DC METER

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Transcription:

V2.0.0 (05.09.2014) 1 (6) COMMISSIONING Mounting - The transmitter should be installed above the measuring point to avoid condensation problems. - The duct overpressure is detected by connecting the measuring point to + connector and by leaving the - connection open (surrounding space pressure). Accordingly, the duct under-pressure is detected by connecting the measuring point to - connector and by leaving the + connection open. - Install the measuring hoses carefully so that the hoses don't bend too tightly. Too tight curves may prevent the air flow to the sensor. - The hose length doesn't effect on the measuring accuracy. However, long hoses generate delay on the measurement. Wiring Device wiring and commissioning can only be carried out by qualified professionals. Always make the wirings while the power is switched off.

2 (6) Selecting the measuring range The measuring range can be selected with the jumpers S2, S3 and S4. A. Pressure selection jumpers S2 S3 S4 ±50 ±100 ±250 ±500 0 100 0 200 0 500 0 1000 * ) * ) Factory setting. The 0 1000 Pa range is also used for the custom range setting. The custom range is 0 1000 Pa as a default. The range can be changed by using ML-SER tool or by defining the limits to the Modbus registers 40001 40002. Selecting the time constant The time constant can be selected with the jumper S1. A. Time constant selection jumper S1 * ) Factory setting. ZERO POINT CALIBRATION 2 s 8 s* ) The purpose of the zero point calibration is to remove the possible long term drift. The zero point is calibrated automatically every five minutes. NOTE: The zero point calibration is also executed on the start-up and a minute after the start-up.

3 (6) ML-SER TOOL With the ML-SER tool you can change the device settings, Modbus settings for example. Connecting ML-SER tool to the device 1. Remove the cover. 2. Disconnect the display cable (N models). 3. Connect the ML-SER tool cable to the display connector. ML-SER menu A. Display connector When the ML-SER is successfully connected, the pressure measurement value is displayed on the ML-SER tool display. The connecting can take few seconds. The device settings can be changed by using ML-SER tool. You can proceed in the menu by pressing the M and OK buttons. The values can be changed with the + and - buttons. The value is accepted with the OK button. The settings are saved when returning the main menu. The following menu structure contains the factory settings. The Modbus and analogue outputs are disabled when entering the menu for the measuring mode. In addition the analogue outputs maintain the same voltage, as they were before entering the menu.

4 (6) Communications menu (M models only) The Modbus settings can be changed through the COMMUNICATIONS menu. Custom range menu Output menu The CUSTOM RANGE menu is for setting the custom pressure range limits. The custom range is in use when all the pressure range selection jumpers are placed. Info menu You can change the measurement output scales through the OUTPUT menu. The INFO menu can be used for checking the software version and resetting to the factory settings. Resetting to the factory settings 1. Press the - button for five seconds in the software version display. 2. Change the resetting dialog answer to yes. 3. Press OK button. The factory settings are now reset.

5 (6) MODBUS Bus properties Protocol RS-485 Modbus RTU Bus speed 9600/19200/38400/57600 bit/s Data bits 8 Parity none/odd/even Stop bits 1 Network size up to 127 devices per segment NOTE: The memory durability is 10000 write cycles. Bus termination The Modbus can be terminated by placing the Modbus termination jumper. A. Modbus termination jumper Supported Modbus functions 0x01 0x02 0x03 0x04 0x05 0x06 0x0F 0x10 0x17 Read Coils Read Discrete Inputs Read Holding Registers Read Input Registers Write Single Coil Write Single Register Write Multiple Coils Write Multiple Registers Read/Write Multiple Registers

6 (6) Modbus registers Data type: bit = 0 or 1 unsigned = unsigned integer (0 65535) signed = integer (-32768 32767) Input registers (read only) Register Parameter description Data type Value Range 30001 Pressure measurement signed -32768 32768-32768 32768 Pa 30002 Time constant unsigned 0 60 0 60 s 30003 Selected pressure range unsigned 0 7 0 = -50 50 Pa 1 = -100 100 Pa 2 = -250 250 Pa 3 = -500 500 Pa 4 = 0 100 Pa 5 = 0 200 Pa 6 = 0 500 Pa 7 = 0 1000 Pa / custom *) 30004 Measurement output signed 0 1000 0 100,0 % *) The custom range is 0 1000 Pa as a default. The range can be changed by using ML-SER tool or by defining the limits to the Modbus registers 40001 40002. Holding registers (read / write) Register Parameter description Data type Value Range Default 40001 Custom scale low limit signed -10 0-1000 0 Pa 0 40002 Custom scale high limit signed 1 10 100 1000 Pa 10 40003 Voltage output scale unsigned 0-1 - 2 0 = 0 10 V 1 = 2 10 V 2 = 0 5 V 40004 Current output scale unsigned 0-1 0 = 4 20 ma 1 = 0 20 ma 0 0