PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-12V35W1A Vac 12Vdc 2.92A

Similar documents
PMT. PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A. Highlights & Features. Safety Standards. Model Number: General Description

Safety Standards. Model Number:

PMT. Model Number: CC Code PM 24V 200W 1 A Panel Mount Product Type T Enclosed L L Frame*

PMT. PMT Panel Mount Power Supply 12V 35W 1 Phase / PMT-12V35W1A. Highlights & Features. Safety Standards. Model Number: General Description

PMT. Safety Standards. Model Number:

PMC. PMC Panel Mount Power Supply 24V 50W 1 Phase / PMC-24V050W1A. Highlights & Features. Safety Standards. Model Number: General Description

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

PMT. Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-12V50W1A Vac 12Vdc 4.17A

PMT. Model Number: CC Code PM 24V 150W 1 A Panel Mount Product Type T Enclosed L L Frame*

Safety Standards. Model Number:

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-12V060W1NA Vac ( Vdc) 12Vdc 5.

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-24V100W1AX Vac ( Vdc) 24Vdc 4.17A

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

PMT. Safety Standards. Model Number:

PMC. Safety Standards. Model Number:

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-D2V100W1A. V1: 3.50A (Selectable by Switch) V2: 5Vdc

Safety Standards. Model Number:

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

PMT. Safety Standards. Model Number:

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

PMT. Safety Standards. Model Number:

PMR. PMR Panel Mount Power Supply 4.2V 252W 1 Phase / PMR-4V320WC A. Highlights & Features. Safety Standards. Model Number: General Description

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-48V150W1B Vac ( Vdc) 48Vdc 3.

Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-24V100W2AA Vac 24Vdc 4.50A

PJ Open Frame Power Supply 24V 50W 1 Phase / PJ-24V50W NA

PMR. PMR Panel Mount Power Supply 5V 300W 1 Phase / PMR-5V320WD A. Highlights & Features. Safety Standards. Model Number: General Description

PMT. Safety Standards. Model Number:

CliQ DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1AZ

PMC. Safety Standards. Model Number:

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-24V600W1BA Vac ( Vdc) 24Vdc 25.

Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-12V100W2B Vac 12Vdc 8.5A PMT-24V100W2B 24Vdc 4.

Sync DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRS-24V30W1AZ

PMH. Safety Standards. Model Number:

Safety Standards. Model Number:

PMF. Safety Standards. Model Number:

PMT. Safety Standards. Model Number:

Chrome DIN Rail Power Supply 12V 25W 1 Phase (Class II & NEC Class 2) / DRC-12V30W1A

Sync DIN Rail Power Supply 5V 15W 1 Phase (NEC Class 2) / DRS-5V30W1NZ

Chrome DIN Rail Power Supply 12V 72W 1 Phase (Class II) / DRC-12V100W1AZ

PJ Open Frame Power Supply 12V 100W 1 Phase / PJ-12V100W A

PJT Highlights & Features

LNE. LED Driver LNE-100W Series / LNE- V100W. Highlights & Features. Safety Standards. Model Number: General Description

Sync DIN Rail Power Supply 24V 30W 1 Phase (NEC Class 2) / DRS-24V30W1AZ

PJ Open Frame Power Supply 24V 100W 1 Phase / PJ-24V100W A

CliQ DIN Rail Power Supply 24V 240W 1 Phase / DRP024V240W1AA

CliQ DIN Rail Power Supply 12V 30W 1 Phase / DRP012V030W1A

Sync DIN Rail Power Supply 24V 50W 1 Phase (NEC Class 2) / DRS-24V50W1N

CliQ DIN Rail Power Supply 12V 30W 1 Phase / DRP012V030W1A

Safety Standards. Model Number:

CliQ II DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1B

Sync DIN Rail Power Supply 5V 50W Series / DRS-5V50W1A / DRS-5V50W1N

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1A

PMH. Safety Standards. Model Number:

CliQ DIN Rail Power Supply 12V 100W 1 Phase / DRP012V100W1AA

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

CliQ II DIN Rail Power Supply 24V 91.2W 1 Phase, NEC Class 2 / DRP-24V100W1NN

LYTE DIN Rail Power Supply 24V 120W 1 Phase / DRL-24V120W1A

PMU Panel Mount Power Supply with Integrated DC-UPS PMU-155W Series / PMU- V155W A PMU. Model Number:

Safety Standards. Model Number:

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

CliQ II DIN Rail Power Supply 24V 120W 3 Phase / DRP024V120W3B

LYTE DIN Rail Power Supply 24V 480W 1 Phase / DRL-24V480W1A

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

LNE. LED Driver LNE-185W Series / LNE- V185W. Highlights & Features. Safety Standards. Model Number: General Description

CliQ II DIN Rail Power Supply 24V 480W 3 Phase / DRP024V480W3B

Safety Standards. Model Number:

CliQ DIN Rail Power Supply 24V 240W 3 Phase / DRP024V240W3AA

PJ Open Frame Power Supply 12V 150W 1 Phase / PJ-12V150W

Safety Standards. Model Number:

Safety Standards. Model Number: Unit Weight:

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

CliQ DIN Rail Power Supply 24V 480W 1 Phase / DRP024V480W1AA

CliQ II DIN Rail Power Supply 48V 480W 1 Phase / DRP048V480W1B

CliQ DIN Rail Power Supply 24V 240W 1 Phase / DRP024V240W1AA

CliQ DIN Rail Power Supply 24V 480W 1 Phase / DRP024V480W1AA

Safety Standards. Model Number:

CliQ DIN Rail Power Supply 24V 240W 3 Phase / DRP024V240W3AA

CliQ II Buffer Module 24V 20A / DRB-24V020AB

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

CliQ II DIN Rail Power Supply 24V 480W 1 Phase / DRP024V480W1B

CliQ II Buffer Module 24V 40A / DRB-24V040ABN

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

LNV. Safety Standards. Model Number:

CliQ II DIN Rail Power Supply 24V 60W 1 Phase, NEC Class 2 / DRP024V060W1N

CliQ II DIN Rail Power Supply 24V 60W 1 Phase / DRP024V060W1B

CliQ II DIN Rail Power Supply 24V 120W 2 Phase / DRP-24V120W2BN

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

CliQ II Buffer Module 24V 20A / DRB-24V020AB

Safety Standards. Model Number:

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

Transcription:

PMT Highlights & Features Universal AC input range Power will not de-rate from input voltage 90Vac to 264Vac High MTBF > 700,000 hrs. per Telcordia SR-332 Short Circuit / Overvoltage / Overload / Over Temperature Protections Versatile connector options (Terminal Block, Front Face, Harness) Safety Standards CB Certified for worldwide use General Description Model Number: PMT-12V35W1A Unit Weight: 0.22 kg Dimensions (L x W x D): 98 x 98 x 38 mm The new PMT series of panel mount power supplies is the latest offering from one of the world s largest power supply manufacturers and solution providers - Delta. The first range of PMT products will offer a nominal output voltage of 12V with a wide operating temperature range from -10 C to +70 C and can withstand shock and vibration requirements (in accordance to IEC 60068-2-27 and IEC 60068-2-6 respectively). In addition to features like overvoltage and overload protections, Delta s PMT series of panel mount power supplies is unlike many other brands in the same price level. The PMT series is designed for cost competitive markets without compromising the quality of the components and product specifications. The series of products has an expected life time of 10 years and will have no output power de-rating from 90Vac to 264Vac. This versatile series has three different connector options (Terminal Block, Front Face and Harness) and can also be converted into L Frame (PML) or Open Frame (PMB) type of power supplies to satisfy different application needs. Model Information Model Number Input Voltage Range Output Voltage Output Current PMT-12V35W1A 85-264Vac 12Vdc 2.92A Model Numbering CC Code** PM 12V 35W 1 A Panel Mount Product Type T Enclosed L L Frame* B Open Frame* *Options **For Terminal Block Output Voltage Output Power Single Phase No PFC Connector Type A Terminal Block G Front Face* H Harness* Blank Without connector cover A With connector cover 1

Specifications Input Ratings / Characteristics Nominal Input Voltage Input Voltage Range Nominal Input Frequency Input Frequency Range Input Current Efficiency at 100% Load Max Inrush Current (Cold Start) Leakage Current 100-240Vac 85-264Vac 50-60Hz 47-63Hz < 0.75A @ 115Vac, < 0.50A @ 230Vac > 84.0% @ 115Vac & 230Vac < 30A @ 115Vac, < 60A @ 230Vac < 1mA @ 240Vac Output Ratings / Characteristics Nominal Output Voltage 12Vdc Output Voltage Tolerance ± 2% (initial set point tolerance from factory) Output Voltage Adjustment Range 11-14Vdc Output Current 2.92A Output Power 35W Line Regulation < 0.5% typ. (@ 85-264Vac input, 100% load) Load Regulation < 1% typ. (@ 85-264Vac input, 0-100% load) PARD (20MHz) < 100mVpp @ 0 C to 50 C, < 150mVpp @ -10 C to 0 C Rise Time Start-up Time Hold-up Time Dynamic Response (Overshoot & Undershoot O/P Voltage) Start-up with Capacitive Loads < 30ms @ nominal input (100% load) < 2500ms @ nominal input (100% load) > 16.7ms @ 115Vac ± 5% @ 0-100% load (Slew Rate: 0.1A/µS) 8,000µF Max 2

Mechanical Case Chassis Case Cover Dimensions (L x W x D) Unit Weight Aluminium SGCC 98 x 98 x 38 mm 0.22 kg Indicator Green LED (DC OK) Cooling System Convection Terminal PM -12V35W1AA M3.5 x 5 Pins (Rated 300V/15A) PM -12V35W1AG M3.5 x 5 Pins (Rated 300V/20A) PM -12V35W1AH I/P (JST): B3P5-VH(LF)(SN) O/P (JST): B2P3-VH(LF)(SN) Wire PM -12V35W1AA AWG 22-12 PM -12V35W1AG AWG 22-12 PM -12V35W1AH AWG 22-18 (For the recommended Housing and Terminal, please refer to the Table on Page 8) Noise (1 Meter from power supply) Sound Pressure Level (SPL) < 25dBA Environment Surrounding Air Temperature Operating -10 C to +70 C Storage -25 C to +85 C Power De-rating > 50 C de-rate power by 2.5% / C Operating Humidity Operating Altitude Shock Test (Non-Operating) 5 to 95% RH (Non-Condensing) 0 to 5,000 Meters IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions Vibration (Non-Operating) IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction Pollution Degree 2 Protections Overvoltage Overload / Overcurrent Over Temperature Short Circuit Protection Against Shock 16V, +10% / -5%, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery) > 120% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) Non-Latching (Auto-Recovery) Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Class I with PE* connection *PE: Primary Earth 3

Reliability Data MTBF Expected Cap Life Time > 700,000 hrs. as per Telcordia SR-332 I/P: 100Vac, O/P: 100% Load, Ta: 35 C) 10 years (115Vac & 230Vac, 50% load @ 40 C) Safety Standards / Directives Electrical Safety TUV Bauart to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1, CB scheme to IEC 60950-1, CCC to GB4943 ITE IEC/EN/UL 60950-1 CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 3.0KVac Input to Ground 1.5KVac Output to Ground 0.5KVac EMC EMC / Emissions CISPR 22, EN 55022, FCC Title 47: Class B Immunity to EN 55024 Electrostatic Discharge IEC 61000-4-2 Level 4 Criteria A 1) Air Discharge: 15kV Contact Discharge: 8kV Radiated Field IEC 61000-4-3 Level 3 Criteria A 1) 80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A 1) 2kV Surge IEC 61000-4-5 Level 3 Criteria A 1) Common Mode 2) : 2kV Differential Mode 3) : 1kV Conducted IEC 61000-4-6 Level 3 Criteria A 1) 150kHz-80MHz, 10Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A 1) 10A/Meter Voltage Dips IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable Low Energy Pulse Test (Ring Wave) IEC 61000-4-12 Level 3 Criteria A 1) Common Mode 2) : 2kV Differential Mode 3) : 1kV 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line) 4

Block Diagram Device Descriptions PMT-12V35W1AA : Terminal Block PMT-12V35W1AG: Front Face PMT-12V35W1AH: Harness 1) Input & Output terminal block connector 2) DC voltage adjustment potentiometer 3) DC OK control LED (Green) 5

Dimensions L x W x D: 98 x 98 x 38 mm (PMT-12V35W1AA : Terminal Block) 6

Engineering Data De-rating Note Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation > 50 C de-rate power by 2.5% / C 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature >50 C, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3. In order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm with adjacent units while the device is in operation. 4. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5. If the device has to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details. Output De-rating VS. Input Voltage No output power de-rating for the input voltage from 90Vac to 264Vac 7

Assembly & Installation A B C Mounting holes for power supply (device). The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5mm length. This surface belongs to customer s end system or panel where the power supply is mounted. Connector Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal) Fig. 2 Recommended Mounting Orientations PM -12V35W1AA / PM -12V35W1AG: Use flexible cable (stranded or solid) of AWG No. 22-12. User should calculate and select the suitable wire specification (type/quantity/diameter) according to actual output current. The torque at the Connector shall not exceed 13Kgf.cm. The insulation stripping length should not exceed 0.275 or 7mm (Refer to Fig. 3). PM -12V35W1AH: Use flexible cable (stranded or solid) of AWG No. 22-18. Please refer to Table 1 for the recommended Housing and Terminal. Table 1 Connector (Board Mounting) Housing Terminal Input (JST) B3P5-VH(LF)(SN) VHR-5N Output (JST) B2P3-VH(LF)(SN) VHR-3N SVH-21T-P1.1 Safety Distance D1 = 4.0mm Min. D2 = 6.0 mm Min. (For PMB Series) Fig. 3 Assembly Reference Ensure the mounted device is kept at 4mm safety distance at all sides from other components and equipments. In addition, to ensure sufficient convection cooling, always maintain a distance of 20mm from ventilated surfaces while the device is in operation. 8

For PMT and PML Series (Refer to Fig. 4): Only use M3 screw 3mm through the base mounting holes. This is to keep a safe distance between the screw and internal components. Recommended mounting tightening torque: 4~7Kgf.cm. For PMB Series: (Refer to Fig. 3): The mounting holes on any mounting accessories for the device should be kept at a diameter of < 6.5mm. This is to ensure sufficient safety distance between the mounting screw and the components around the mounting holes on the PCBA. Therefore, the diameter of the mounting screw should be kept at < 6.5mm. Fig. 4 Mounting Screw Safety Instructions If user s mounting orientation is not according to the recommended mounting orientations, please consult Delta for further information. L frame (PML) and Open frame (PMB) options are to be manufactured by Delta and not to be reconfigured by users from the standard enclosed configuration. The device is not recommended to be placed on low thermal conductive surface. For example, plastics. The enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! Do not touch the terminals while power is being supplied. Risk of electric shock. Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause electric shock, safety hazard, fire and/or product failure. The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended that the Earth terminal on the connector be connected to the grounded surface. Warning (For Standard Terminal Block and Front Face Terminal Block products): When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. Accessories L-01: Latch P-03: Bracket These accessories are used to mount the panel mount power supply onto a DIN rail. 9

Functions Start-up Time The time required for the output voltage to reach 90% of its set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its set value. Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 95% of its set value, after the input voltage is removed. Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. Dynamic Response The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 0 to 100% of its rated current. 10

Overload & Overcurrent Protections The power supply s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds 120% of I O (Max load). In such occurrence, the V O will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into Hiccup mode (Auto-Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and I O is back within the specifications. Overvoltage Protection The power supply s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under Protections. Additionally, if the I O is <120% but >100% for a prolong period of time (depending on the load), the Over Temperature Protection (OTP) will be activated due to high temperature on critical components. The power supply will then go into Hiccup mode until the fault is removed. Over Temperature Protection As mentioned above, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating graph. Short Circuit Protection The power supply s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in Hiccup mode, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. Others Delta RoHS Compliant Restriction of the usage of hazardous substances The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation for Restriction of the use of certain hazardous substances in electrical and electronic equipment. This product conforms to this standard. 11

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Delta Electronics: PMT-12V35W1AA PMB-12V35W1AA PMT-12V35W1AG PMT-12V35W1AH PMB-12V35W1AH PML-12V35W1AH