Keysight M9393A PXIe Vector Signal Analyzer

Similar documents
Keysight M9381A PXIe VSG, M9380A PXIe CW Source, and M9391A PXIe VSA

86100 Series Infiniium DCA Oscilloscope

Keysight N5191A/93A UXG X-Series Agile Signal Generator

Firmware Guide. Keysight PXIe Chassis Family

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

Agilent CSV Export Utility

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Keysight E7515A UXM Firmware Update Tool

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

87421/22A Power Supply. Operating and Service Manual

Agilent OpenLAB Data Analysis Upload Download Tool. User s Guide

Agilent OpenLAB Chromatography Data System (CDS)

BenchCel Workstations Software

Agilent OpenLAB. Data Store. Backup and Restore Guide

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Agilent 1260 Infinity Purification Solution

Agilent Series Logic Analysis System

Agilent OpenLAB. Data Store. Maintenance Guide

Keysight N108xA-Series IEEE Ethernet KR/CR Compliance and Debug Application

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Chromatography Data System

Agilent Technologies E5385A 100-Pin Probe

Agilent OBSAI Protocol Tester

Agilent Lab Advisor. IT Administrator's Guide. Agilent Technologies

Agilent EZChrom SI. Startup Guide

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Agilent W2100 Antenna Modeling Design System

Agilent OpenLAB Chromatography Data System (CDS)

Setting Up Probes. Online Help

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Agilent E2094M IO Libraries

Agilent OpenLAB Chromatography Data System

Agilent ChemStation Plus

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Firmware Updates Model 24 / 44 / 42 Cryogenic Temperature Controllers

Agilent OpenLAB Chromatography Data System (CDS)

Agilent InfiniiMax II 1168A/1169A Probes

PSA-Series Spectrum Analyzers

BIT-3000 Dynamic Sequencing Generator and Analyzer. Datasheet 1.11

Nimsoft Monitor. proxy Guide. v3.1 series

Microscan Barcode Reader

Agilent 89600B VSA. Software Installation Guide

Agilent OpenLAB Data Store. Maintenance Guide

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect

Agilent Gb/s Serial BERT

Agilent OpenLAB Chromatography Data System (CDS)

Agilent Technologies. Connectivity Guide. USB/LAN/GPIB Interfaces. Agilent Technologies

Agilent ChemStation Plus

Agilent OpenLAB Data Store Administration. Guide for Administrators

Keysight Add Source and Receiver Attenuators Upgrade Kit

Agilent CytoGenomics 2.5

Automated Plate Labeling

Operations and Installation Manual. Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

DDR/LPDDR Custom Configuration Creator Tool. User s Guide

Quick Start/Installation Guide

Agilent Dissolution Tester Driver

Agilent Protocol Analyzer and Jammer for USB. Quick Start Guide

Agilent G2721AA/G2733AA

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Agilent ChemStation for UV-visible Spectroscopy

Agilent N5410A Fibre Channel Automated Test Application

Agilent ChemStation. ECM Interface Guide. Agilent Technologies

Agilent OpenLAB ECM Intelligent Reporter

Agilent Genomic Workbench 6.0

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide

Keysight Software

Nimsoft Monitor. xendesktop Release Notes. All series

Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter

Nimsoft Monitor. sysstat Guide. v1.1 series

Keysight N5990A Test Automation Software Platform

U85026A Detector 40 to 60 GHz

Errata. Agilent References in this manual. About this manual. Support for your product

G5584A Labware MiniHub

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Unified Infrastructure Management Compatibility Matrix June 26, 2015

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

PlateLoc ActiveX v3.1

Security Features and Volatility Documentation

Nimsoft Monitor. ntp_response Guide. v1.2 series

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

4287A Security Features Rev. 1.0

Nimsoft Service Desk. Single Sign-On Configuration Guide. [assign the version number for your book]

Keysight N5990A DisplayPort Extended Tests Embedded DisplayPort

Programming Note. Agilent Technologies Quick Reference Guide For the 8757D/E Scalar Network Analyzer

Agilent OpenLAB CDS Waters Alliance HPLC Instrument Control Add-On. Installation, Upgrade and Migration Guide

Agilent MassHunter Metabolite ID Software. Installation and Getting Started Guide

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Notices. DFARS/Restricted Rights Notice. Warranty. Technology Licenses. Document History

Automated Plate Centrifugation

Unified Infrastructure Management Compatibility Matrix September 05, 2017

Nimsoft Unified Management Portal

8560E/EC-Series Spectrum Analyzers. Security Features and Volatility

Agilent Genomic Workbench 7.0

Nimsoft Monitor. cluster Guide. v2.6 series

CA Nimsoft Monitor for Flow Analysis

Transcription:

Security Guide Keysight M9393A PXIe Vector Signal Analyzer. Notice: This document contains references to Agilent. Please note that Agilent s Test and Measurement business has become Keysight Technologies. For more information, go to www.keysight.com.

M9393A Security Guide (M9393-90021), page 2 of 17

Notices Keysight Technologies, Inc. 2013-2014 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technologies, Inc. as governed by United States and international copyright laws. Trademark Acknowledgements N/A Manual Part Number M9393-90021 Print Date October 2014 Supersedes: July 2013 Published in USA Keysight Technologies Inc. 1400 Fountaingrove Parkway Santa Rosa, CA 95403 Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED AS IS, AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. Restricted Rights Legend If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as Commercial computer software as defined in DFAR 252.227-7014 (June 1995), or as a commercial item as defined in FAR 2.101(a) or as Restricted computer software as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Keysight Technologies standard commercial license terms, and non-dod Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data. Safety Notices M9393A Security Guide (M9393-90021), page 3 of 17 A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.

Warranty This Keysight technologies instrument product is warranted against defects in material and workmanship for a period of one year from the date of shipment. During the warranty period, Keysight Technologies will, at its option, either repair or replace products that prove to be defective. For warranty service or repair, this product must be returned to a service facility designated by Keysight Technologies. Buyer shall prepay shipping charges to Keysight Technologies, and Keysight Technologies shall pay shipping charges to return the product to Buyer. For products returned to Keysight Technologies from another country, Buyer shall pay all shipping charges, duties, and taxes. Where to Find the Latest Information Documentation is updated periodically. For the latest information about these products, including instrument software upgrades, application information, and product information, see the following URLs: http://www.keysight.com/find/pxa http://www.keysight.com/find/mxa http://www.keysight.com/find/exa http://www.keysight.com/find/cxa To receive the latest updates by email, subscribe to Keysight Email Updates: http://www.keysight.com/find/mykeysight Information on preventing instrument damage can be found at: Is your product software up-to-date? Periodically, Keysight releases software updates to fix known defects and incorporate product enhancements. To search for software updates for your product, go to the Keysight Technical Support website at: http://www.keysight.com/find/techsupport M9393A Security Guide (M9393-90021), page 4 of 17

M9393A Security Guide (M9393-90021), page 5 of 17

Table of Contents Notices... 3 Trademark Acknowledgements... 3 Manual Part Number... 3 Print Date... 3 Warranty... 3 Technology Licenses... 3 Restricted Rights Legend... 3 Safety Notices... 3 Warranty... 4 Where to Find the Latest Information... 4 Is your product software up-to-date?... 4 Product Memory Sanitization... 7 M9393A PXIe Vector Signal Analyzer Drivers... 8 M9300A PXIe Frequency Reference... 9 M9308A PXIe Synthesizer: 187.5 MHz to 3 GHz or 6 GHz... 10 M9365A PXIe Downconverter... 11 M9214A PXIe IF Digitizer... 12 M9393A Memory Clear Code... 13 Contacting Keysight Sales and Service Offices... 15 Security Terms and Definitions... 16 References... 17 M9393A Security Guide (M9393-90021), page 6 of 17

Product Memory Sanitization Sanitization processes for the following Keysight product models are covered by this document: Multi-module instrument: o M9381A PXIe Vector Signal Analyzer drivers PXIe modules: o M9300A PXIe Frequency Reference o M9308A PXIe Synthesizer o M9365A PXIe Downconverter o M9214A PXIe IF Digitizer M9393A Security Guide (M9393-90021), page 7 of 17

M9393A PXIe Vector Signal Analyzer Drivers This product uses the same AgM9393 driver. The driver installs the IVI-C, IVI-COM, and MATLAB driver components, as well as the soft front panel and kernel device driver on your controller. Memory Type: Controller Hard Drive Memory Size: unknown Memory Function: Stores device drivers, example programs, example waveforms, help system, user documentation, and customer-specific frequency alignment data. Memory Erase Processes: To uninstall the AgM9393 instrument driver from the controller, perform the relevant procedure below. Windows 7: 1. Select Start > Control Panel > Programs and Features 2. Select Keysight M9393 3. Select Uninstall To remove customer-specific frequency alignment data: Navigate to C:\ProgramData\Keysight\<Model#>\FieldAlignment and delete the contents. Where <Model#> is: M9393A M9308A M9214A M9365A To clear all information from the controller used with the M9393A PXIe Vector Signal Analyzer, follow the memory erase procedure for the controller as recommended by the manufacturer. M9393A Security Guide (M9393-90021), page 8 of 17

M9300A PXIe Frequency Reference Memory Function: Stores module model number, serial number, manufacturing number, PCB part and version numbers, cal verify date, max module temperature, and calibration data. User Modifiable? No Memory Erase Processes: None, this is not user accessible Memory Function: Device firmware. Images can be changed using the Keysight Soft Front Panel firmware update utility. User Modifiable? No Memory Erase Processes: None, this is not user accessible Memory Function: Stores calibration preferences: due date subject to periodic cal, module cal warnings, cal due reminder, module cal reminder and passphrase Memory Erase Processes: You can clear the passphrase by using the relevant IVI driver code: If the module is used in an M9393A instrument, see M9393A Memory Clear Code (page 13). Memory Type: FPGA Memory Size: Memory Function: Reference output selections, external reference and frequency selections, time shift and self test results Volatile? Yes Memory Erase Processes: Cycle power Memory Function: Stores User Customizable Asset Number and System Identification Memory Erase Processes: You can clear the asset number and system identification values by using the relevant IVI driver code: If the module is used in an M9393A instrument, see M9393A Memory Clear Code (page 13). M9393A Security Guide (M9393-90021), page 9 of 17

M9308A PXIe Synthesizer: 187.5 MHz to 3 GHz or 6 GHz (NOTE: The M9308A PXIe Synthesizer is only used with M9393A PXIe Vector Signal Analyzer.) Memory Function: Stores Module Model Number, Serial Number, Manufacturing Number, Options, PCB Part and Version Numbers, Cal Verify Date, Max Module Temperature, and Calibration and Alignment Data. User Modifiable? No Memory Erase Processes: None, this is not user accessible Memory Function: Device firmware. Images can be changed using the Keysight soft front panel firmware update utility. User Modifiable? No Memory Erase Processes: None, this is not user accessible Memory Function: Stores calibration preferences: due date subject to periodic cal, module cal warnings, cal due reminder, module cal reminder and passphrase Memory Erase Processes: You can clear the passphrase by using the relevant IVI driver code: If the module is used in an M9393A instrument, see M9393A Memory Clear Code (page 13). Memory Type: FPGA Memory Size: Memory Function: Frequency start/stop/step, power, waveform, and impairments. Volatile? Yes Memory Erase Processes: Cycle power Memory Function: Stores user customizable asset number and system identification Memory Erase Processes: You can clear the asset number and system identification values by using the relevant IVI driver code: If the module is used in an M9393A instrument, see M9393A Memory Clear Code (page 13). M9393A Security Guide (M9393-90021), page 10 of 17

M9365A PXIe Downconverter (NOTE: The M9365A PXIe Downconverter is only used with M9393A PXIe Vector Signal Analyzer.) Memory Function: Stores module model number, serial number, manufacturing number, options, PCB part and version numbers, cal verify date, max module temperature, and calibration and alignment data. User Modifiable? No Memory Erase Processes: None, this is not user accessible Memory Function: Device firmware. Images can be changed using the Keysight Soft Front Panel firmware update utility. User Modifiable? No Memory Erase Processes: None, this is not user accessible Memory Function: Stores calibration preferences: due date subject to periodic cal, module cal warnings, cal due reminder, module cal reminder and passphrase Memory Erase Processes: To clear the passphrase, use the IVI driver code provided in M9393A Memory Clear Code (page 13). Memory Type: FPGA Memory Size: Memory Function: Stores: IQ, spectrum and power settings; advanced options; dither; alignments. Volatile? Yes Memory Erase Processes: Cycle power Memory Function: Stores User Customizable Asset Number and System Identification Memory Erase Processes: To clear the asset number and system identification values, use the IVI driver code provided in M9393A Memory Clear Code (page 13). M9393A Security Guide (M9393-90021), page 11 of 17

M9214A PXIe IF Digitizer (NOTE: The M9214A PXIe IF Digitizer is only used with M9393A and M9391A PXIe Vector Signal Analyzers.) Memory Function: Stores module model number, serial number, manufacturing number, options, PCB part and version numbers, cal verify date, max module temperature, and calibration and alignment data. User Modifiable? No Memory Erase Processes: None, this is not user accessible Memory Function: Device firmware. Images can be changed using the Keysight Soft Front Panel firmware update utility. User Modifiable? No Memory Erase Processes: None, this is not user accessible Memory Function: Stores calibration preferences: due date subject to periodic cal, module cal warnings, cal due reminder, module cal reminder and passphrase Memory Erase Processes: To clear the passphrase, use the IVI driver code provided in M9393A Memory Clear Code (page 13). Memory Type: FPGA Memory Size: Memory Function: Stores: IQ, spectrum and power settings; advanced options; dither; alignments. Volatile? Yes Memory Erase Processes: Cycle power Memory Function: Stores User Customizable Asset Number and System Identification Memory Erase Processes: To clear the asset number and system identification values, use the IVI driver code provided in M9393A Memory Clear Code (page 13). M9393A Security Guide (M9393-90021), page 12 of 17

M9393A Memory Clear Code Below is the IVI code to clear the memory from the M9393A PXIe Vector Signal Analyzer and its modular components (M9300A Reference, M9308A Synthesizer, M9365A Downconverter, and M9214A Digitizer). The procedures in this code sample clear the Asset Number, System ID, and Cal passphrase from the flash memory. All you need to do is copy and paste the code into a console application and include the correct driver references see inset picture (right). using System; using System.Collections.Generic; using System.Linq; using System.Text; using Ivi.Driver.Interop; using Agilent.AgM9393.Interop; namespace M9393A_Security_Erase { class Program { static void Main(string[] args) { //Running this program will clear the flash memory of the M9393A Vector Signal Analyzer multi-module instrument. //The flash memory cleared is the Asset Number, System ID, and the passphrase protecting the calibration preferences. //ONLY run this program if you are sure you want to clear this information. //initialize the driver IAgM9393 m9393a = new AgM9393(); string resource = ""; //enter in the VISA resource between the quotes for the instrument getting cleared string options = "QueryInstrStatus=true, Simulate=false, DriverSetup=Trace=false"; bool idquery = true; bool reset = true; m9393a.initialize(resource, idquery, reset, options); Console.WriteLine("Driver Initialized.\n Press enter to continue\n"); Console.ReadLine(); //Test to write to modules. It is commented out because it does not need to be run to clear the memory. //m9393awrite(m9393a.modules.get_item("m9300a")); //m9393awrite(m9393a.modules.get_item("m9308a")); //m9393awrite(m9393a.modules.get_item("m9365a")); //m9393awrite(m9393a.modules.get_item("m9214a")); //Read back asset numbers and system ID from each module string refasset = m9393a.modules.get_item("m9300a").nonvolatile.assetnumber; string refid = m9393a.modules.get_item("m9300a").nonvolatile.systemidentification; string synthasset = m9393a.modules.get_item("m9308a").nonvolatile.assetnumber; string synthid = m9393a.modules.get_item("m9308a").nonvolatile.systemidentification; string DCAsset = m9393a.modules.get_item("m9365a").nonvolatile.assetnumber; string DCID = m9393a.modules.get_item("m9365a").nonvolatile.systemidentification; string digasset = m9393a.modules.get_item("m9214a").nonvolatile.assetnumber; string digid = m9393a.modules.get_item("m9214a").nonvolatile.systemidentification; Console.WriteLine("Reference Asset is:" + refasset + "\n"); Console.WriteLine("Reference System ID is:" + refid + "\n"); Console.WriteLine("Synthesizer Asset is:" + synthasset + "\n"); Console.WriteLine("Synthesizer System ID is:" + synthid + "\n"); Console.WriteLine("DownConverter Asset is:" + DCAsset + "\n"); Console.WriteLine("DownConverter System ID is:" + DCID + "\n"); Console.WriteLine("Digitizer Asset is:" + digasset + "\n"); Console.WriteLine("Digitzer System ID is:" + digid + "\n\n"); //Begin clear Console.WriteLine("Press Enter to Clear asset number and system ID"); Console.ReadLine(); M9393A Security Guide (M9393-90021), page 13 of 17

//Clear asset number and system ID and Calibration Preferences passphrase. m9393aclear(m9393a.modules.get_item("m9300a")); m9393aclear(m9393a.modules.get_item("m9308a")); m9393aclear(m9393a.modules.get_item("m9365a")); m9393aclear(m9393a.modules.get_item("m9214a")); //Read back module asset numbers and ID to verify memory clear. Console.WriteLine("press enter to verify clear"); Console.ReadLine(); refasset = m9393a.modules.get_item("m9300a").nonvolatile.assetnumber; refid = m9393a.modules.get_item("m9300a").nonvolatile.systemidentification; synthasset = m9393a.modules.get_item("m9308a").nonvolatile.assetnumber; synthid = m9393a.modules.get_item("m9308a").nonvolatile.systemidentification; DCAsset = m9393a.modules.get_item("m9365a").nonvolatile.assetnumber; DCID = m9393a.modules.get_item("m9365a").nonvolatile.systemidentification; digasset = m9393a.modules.get_item("m9214a").nonvolatile.assetnumber; digid = m9393a.modules.get_item("m9214a").nonvolatile.systemidentification; Console.WriteLine("Reference Asset No is:" + refasset + "\n"); Console.WriteLine("Reference System ID is:" + refid + "\n"); Console.WriteLine("Synthesizer Asset No is:" + synthasset + "\n"); Console.WriteLine("Synthesizer System ID is:" + synthid + "\n"); Console.WriteLine("DownConverter Asset No is:" + DCAsset + "\n"); Console.WriteLine("DownConverter System ID is:" + DCID + "\n"); Console.WriteLine("Digitizer Asset is:" + digasset + "\n"); Console.WriteLine("Digitzer System ID is:" + digid + "\n\n"); Console.WriteLine("\n Memory clear complete, press enter to exit program"); Console.ReadLine(); } //Close the driver session. m9393a.close(); } } //Test method to write to the modules. It is commented out because it does not need to be run to clear the memory. //static void m9393awrite(iagm9393module module) //{ // module.nonvolatile.clear(); // module.nonvolatile.systemidentification = "system ID"; // module.nonvolatile.assetnumber = "123456789"; // string oldpassphrase = module.nonvolatile.passphrase; // module.nonvolatile.write(oldpassphrase); //} //Method to clear the Passphrase and Asset Number/System ID of each module. static void m9393aclear(iagm9393module module) { module.nonvolatile.clear(); module.nonvolatile.systemidentification = ""; module.nonvolatile.assetnumber = ""; string newpassphrase = ""; string oldpassphrase = module.nonvolatile.passphrase; module.nonvolatile.passphrase = newpassphrase; module.nonvolatile.write(oldpassphrase); } M9393A Security Guide (M9393-90021), page 14 of 17

Contacting Keysight Sales and Service Offices Assistance with test and measurement needs, and information on finding a local Keysight office, is available on the Internet at: http://www.keysight.com/find/assist If you do not have access to the Internet, please contact your field engineer. In any correspondence or telephone conversation, refer to the instrument by its model number and full serial number. With this information, the Keysight representative can determine whether your unit is still within its warranty period. M9393A Security Guide (M9393-90021), page 15 of 17

Security Terms and Definitions Term Clearing Instrument Declassification Sanitization Secure Erase Definition As defined in Section 8-301a of DoD 5220.22-M, clearing is the process of eradicating the data on media before reusing the media so that the data can no longer be retrieved using the standard interfaces on the instrument. Clearing is typically used when the instrument is to remain in an environment with an acceptable level of protection. A term that refers to procedures that must be undertaken before an instrument can be removed from a secure environment, such as is the case when the instrument is returned for calibration. Declassification procedures include memory sanitization or memory removal, or both. Keysight declassification procedures are designed to meet the requirements specified in DoD 5220.22-M, Chapter 8. As defined in Section 8-301b of DoD 5220.22-M, sanitization is the process of removing or eradicating stored data so that the data cannot be recovered using any known technology. Instrument sanitization is typically required when an instrument is moved from a secure to a nonsecure environment, such as when it is returned to the factory for calibration. Keysight memory sanitization procedures are designed for customers who need to meet the requirements specified by the US Defense Security Service (DSS). These requirements are specified in the Clearing and Sanitization Matrix in Section 5.2.5.5.5 of the ISFO Process Manual. Secure Erase is a term that is used to refer to either the clearing or sanitization features of Keysight instruments. M9393A Security Guide (M9393-90021), page 16 of 17

References Check references and hyperlinks whenever this document is revised! 1. DoD 5220.22-M, National Industrial Security Program Operating Manual (NISPOM) United States Department of Defense. Revised February 28, 2006. May be downloaded in Acrobat (PDF) format from: http://www.dss.mil/isp/fac_clear/download_nispom.html 2. ISFO Process Manual for the Certification and Accreditation of Classified Systems under the NISPOM Defense Security Service. DSS-cleared industries may request a copy of this document via email, by following the instructions at: http://www.dss.mil/isp/odaa/request.html 3. Add further references here M9393A Security Guide (M9393-90021), page 17 of 17