G 1/2 30,5 A Brass NBR 0,8 3,

Similar documents
6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Operating pressure (bar) kv factor (m 3 /h) *3)

Flow. Flow. N/en

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

V88 series Redundant valve manifold systems - Semi modular 2oo2 Availability

Operating pressure (bar)

Flow. (l/min) (ms) N/en

V88 series Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Operating pressure. N/en/en

26230, Inline 3/2, 5/2 and 5/3 way soft seal spool valves electromagnetic actuated, indirectly controlled G 1/4, G 1/2

Material pressure (bar) (Cv (US) kv x 1,2 Seat

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface

21023, 21025, 2/2 Direct solenoid actuated poppet valves

80265 series, 3/2 Indirect solenoid actuated poppet valve

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

Operating pressure. N/en/en

Material Seat seal. N/en

Series 95000, 2/2 Direct solenoid actuated poppet valve

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Technical features. N/en

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97105 Inline, 3/2 & 5/2 Direct pneumatically actuated spool valves

97105 Inline direct pneumatically actuated 3/2 and 5/2 spool valves G 1/4.G1/2, 1/4 NPT 1/2 NPT

24011 series, 3/2 Direct solenoid actuated poppet valve

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

Technical features. 12/ f. N/en

98015 series, 3/2 Direct solenoid actuated poppet valve

60 series, 2/2 or 3/2 Ball valve

21D Allfluid pressure switch, electromechanically actuated

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

26360, NAMUR. Technical data

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

SCVA08, SCVA10, SCVA20 & SCVA32, 3/2 Solenoid actuated safety valve

ICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves

SPCH/ Big bottle blowing block

15 and 16 Series BSP and hose fittings

M/60100/M, Slide units Magnet piston, double acting

BSP & HOSE Fittings M5, 1/8... 1

V87 series - Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

ISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

RM/28000/M, ISO cylinder Magnetic piston, single acting

R./57100/M, R./57300/M, Roundline cylinder Magnetic piston, single acting

LB74G - EXCELON Modular System General purpose filter/regulator

RM/92000/M, Short stroke cylinder Magnetic piston, double acting

V03, V04 and V05 Series

10 series (Pneufit) Push-in fittings Ø mm O/D tube, BSP threads

PNEUFIT 10 series Push-in fittings

10 series (Pneufit) Push-in fittings Ø mm tube size, BSP threads

B64G - Olympian Plus plug-in system Filter/regulator

HERION SERIES Indirect solenoid actuated spool valves

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

VCB22, 5/2 Solenoid actuated In-line spool valves

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

Motorised butterfly valve DMK Nominal Diameters DN 40 to DN 125

Pneumatic Control/Feedback

Pneumatic Control/Feedback

Old documentation - Only for your information! Product is not available anymore!

RT2E Compact temperature switch Explosion proof

Motorised Butterfly Valve DMK

3/2 5/2 SERIES 362/562

Double piston cylinder, Series TWC Ø6-32 mm double-acting with magnetic piston cushioning: elastic

Compression Fittings 34 Series Inch

Block diagram MB-VEF

Flowtronic D 607 Series

Motorised Butterfly Valve DMK Nominal Diameter Rp 3/4 - Rp 2

RT2Y Compact temperature switch intrinsic safety

Pneumatic Control/Feedback

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Control Head for the integrated mounting on process valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

Nickel Plated BSP & Hose Fittings

Compact pressure switch for multiple actuators

I ntroduction. RA Fast Running Electric Actuator. Features and Benefits

Pilot operated 2 port solenoid valve (general purpose valve) 100 VAC 50/60Hz 110 VAC 60Hz 200 VAC 50/60Hz 220 VAC 60Hz 12 VDC 24 VDC 48 VDC 100 VDC

3-PORT SEAT VALVES PN16 WITH EXTERNALLY THREADED CONNECTIONS STAZ-16, STBZ-16, STCZ-53 DATASHEET

M3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems

Series P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Digital electropneumatic Positioner for the integrated mounting on process control valves

Technical Data. General specifications. Rated operating distance s n 3 mm

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Control Head for the integrated mounting on process valves

Control head for hygienic process valves

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

PGS10 Series Pressroom Gripper System

Series 3730 Type Electropneumatic Positioner

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Direct solenoid and solenoid pilot operated valves

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Standard enclosure for Remote I/O Series 8150

Double solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN 65 - DN 100

2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET

UPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps

Transcription:

4/2 way poppet valves electromagnetic actuated, directly controlled /4 & /2 Working from 0 bar up Suitable for vacuum range down.33 0-2 mbar l/s Protection class : IP 65, Ex em, Ex d TEX approved (see solenoid table) Suited for outdoor installation pproval depends on magnetic system, see page 2! Technical features Medium: For neutral gaseous and liquid fluids Operation: Solenoid, directly controlled Operating pressure: 25 bar max. Nominal size: 8... 2 mm Port size: /4... /2 Mounting position: Optional, preferably vertical Flow direction: Fixed : M20x,5, /2 NPT Fluid/ambient temperature: -25... +80 Solenoid operators: see table epending on solenoid system ir supply must be dry enough to avoid ice formation at temperatures below +2. For outdoor installations must be protected all s against the penetration of moisture and a solenoid with IP66 protection must be used! Materials: Housing: rass 2.040 (Ms 58) Inner parts: rass or stainless steel.404 (430 F) Seat seal: NR Technical data Symbol Port size Solenoid Nominal Operating pressure Materials kv-value s *) group Size min. max. Valve- (v (US) = kv x,2 (kg) (mm) (bar) (bar) Housing Seat seal 2 3 /4 30,5 8 0 0 rass NR 0,5 2,4 250050 /2 30,5 2 0 0 rass NR 0,8 3, 2 2502250 4 /2 38,5 2 0 25 rass NR 0,9 4,0 3 2502550 *) When ordering please indicate solenoid, voltage and current type (frequency). 5/4 2004-533d without notice, the specifications given in this document. 204 Norgren mbh N/en 5.4.340.0

Solenoid operators Solenoids group 30,5 (W) (V) (m ) (m ) (TEX-ategory) ( ) (kg) 2,4 89 IP65 (with cable gland) -25...+60 M20x,5,35 2 2 300 ircuit 22,8 99 IP65 (with cable gland) -25...+60 M20x,5,35 2 6 30 2,4 89 II2 II3 Ex e mb II T4 b Ex tb III T20 b IP 65 (with cable gland) -20...+80 T4-40...+60 T5 M20x,5 2,0 22 4 440 22,8 99 II2 II3 Ex e mb II T4 b Ex tb III T20 b I IP 65 (with cable gland) -20...+80 T4-40...+60 T5 M20x,5 2,0 22 7 44 IP 66 version on request Solenoids group 30,5 (W) (V) Solenoids group 38,5 2,4 89 II2 II2 22,8 99 II2 II2 *6) able gland not supplied, see table»ccessories«(w) (V) (m ) (m ) (m ) (m ) (TEX-ategory) Ex d II T4 b Ex tb III T90 b IP 66 (with cable gland) Ex d II T4 b Ex tb III T90 b IP 66 (with cable gland) (TEX-ategory) 38,7 64 IP 65 (with cable gland) -25...+60 Fluid max. +80 ( ) (kg) -40...+60 /2 NPT *6) 3,3 29 2 480-40...+60 /2 NPT *6) 3,3 29 6 48 ( ) ircuit ircuit (kg) M20x,5 2,5 23 2 500 42, 69 IP 65 (with cable gland) -25...+60 Fluid max. +80 M20x,5 2,5 23 6 50 38,7 64 II2 II2 Ex e mb II T4 b IP65 (with cable gland) -20...+40 M20x,5 *6) 3,6 24 2 570 42, 69 II2 II2 Ex e mb II T4 b IP65 (with cable gland) -20...+40 M20x,5 *6) 3,6 24 6 57 *6) able gland not supplied, see table»ccessories«ip 66 version on request pprovals pprovals atasheet TEX IEEx FM 43x, 44x KEM 03 TEX 06 X IEEx EK.0066X N/en 7..50 48x, 68x VS 2 TEX E 068 X N/en 7..55 5xx, 57x EKR VS 08 TEX E 7 N/en 7..520 N/en 5.4.340.02 without notice, the specifications given in this document. 204 Norgren mbh 2004-533d 5/4

ccessories able gland protection class IP65 Ms nickel plated brass able gland protection class (TEX) Ms nickel plated brass Port size able Ø Protection class able Ø M 20x,5 6,5...9,5 mm 058924 II2 Ex e 5...8 mm 058889 M 20x,5 9,0...3 mm 0589242 II2 Ex d 0...4 mm 058885 /2-4-NPT II2 Ex d 7,5...,9 mm 0588925 Silencer *) Exhaust guard *2) Page 5 Page 5 M/S4 /2 063423 (/2, /2 NPT) /S4 /2 NPT *) For indoors use only *2) For outdoors use, opening pressure ~ 0,2 bar s for valves 3... 40 3 56 T 4 2 3 ø 6,5 N E M ø P s solenoids see page 4 2 For port size, see technical data F 2 K L R S s E F J K L M N Ø P R S T 62 24 63 35 49 77 59 20 40 33 46 7 7 4 30 2 83 45 8 4 52 92 59 22 44 34 66 7 20 48 37 3 83 49 8 4 52 92 62 22 44 34 66 7 20 48 37 5/4 2004-533d without notice, the specifications given in this document. N/en 5.4.340.03

s for solenoid operators 2 22 29 ø 86 4,5 50 ø 86 25 ø 30,5 78 6 ø 30,5 3 55 00 /2-4 NPT 3 65 23 24 ø 92 ø 92 ~ 43 82 34 83 + 66 M 8 2 85 54 ~ Solenoid 48x Ø 30,5 mm ø 38,7 ø 38,7 ircuit s 2 4 6 7 N/en 5.4.340.04 without notice, the specifications given in this document. 204 Norgren mbh 2004-533d 5/4

able gland 0588925 only ø M20 x,5 6 26 6,5... 9,5 22 058924 M20 x,5 6,5 26 9... 3 22 0589242 M20 x,5 9 36 5... 8 22 058889 M20 x,5 4 39 0... 4 24 058885 /2-4 NPT 5 58 7,5...,9 24 0588925 Silencer : M/S2, M/S4, /S2, /S4 Exhaust guard : 063422, 06323 ø ø Ø (g) /4 7 35,5 5,5 2,9 M/S2 /4 NPT 7 35,5 5,5 2,9 /S2 /2 2 67 23,5 M/S4 /2 NPT 2 67 23,5 /S4 Suitable for Ø (g) /4 /4, /4 NPT 0 26,5 2 5 063422 /2 /2, /2 NPT 2 33,5 29 063423 Warning These products are intended for use in industrial compressed air and fluid systems only. o not use these products where values can exceed those listed under Technical features/data. efore using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. 5/4 2004-533d without notice, the specifications given in this document. N/en 5.4.340.05