HCC-F Software. Honigmann Computer Control - Precision Friction Meter

Similar documents
DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A...

DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A...

u TESTER 6-C800 The quality testing system Technical Data

User Manual. Recorder of environmental conditions THBR. Version: 2.0.2

Hand-Held Thermometer Model CTH 6200

Logger Pro 3. Quick Reference

SL-10 Laboratory Hot Tack / Seal Tester. TMI Group of Companies

Spectrometer Visible Light Spectrometer V4.4

USTER TESTER 5-C800. The filament yarn inspection system. Technical Data

Acquisition and Evaluation, 2825A... TEL: Measuring Instrument Control and Configuration via Communication Interfaces RS-232C 501

Overview DT Measure Foundry is a drag-anddrop test and measurement application builder designed to give you top performance

Soft-Engine - Data store software: Version 8

3 CLIO INSTALLATION 3.1 MINIMUM PC CONFIGURATION 3.2 FW-01 DRIVERS INSTALLATION UNDER WINDOWS 8 OR 10

TABLE OF CONTENTS PRODUCT DESCRIPTION VISUALIZATION OPTIONS MEASUREMENT OPTIONS SINGLE MEASUREMENT / TIME SERIES BEAM STABILITY POINTING STABILITY

DataFlow. DataFlow. Electronics & Software. Quality Monitoring System. DataFlow Statistics. Type 2805A...

Small Tensile Testers for universal usage Z3, Z5 Z10 Z20, Z50. page 1

Operating Instructions / User manual. IRSoft. Version 2.0. Documentation software for ERSA Rework Systems. ERSA GmbH

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

SCTMWEXL. Manual. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

WIRELESS OFFICE DESKTOP SL DESIGN

INTERACTIVE WHITEBOARDS: SMART Board Overview

USTER ZWEIGLE TWIST TESTER 5-SA

CENTAUR S REAL-TIME GRAPHIC INTERFACE V4.0 OPERATOR S MANUAL

User Manual (Vers. 1.03)

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151

Fischerscope X Ray CIRCULARS 07/01

HDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual

Peregrine Technology CO.,LTD. DSO Oscilloscope. User Menu. V1.1 Date: 2014/07/11

motcom loganalyser User Manual

L.D.S. Laser Diffraction Sensor USER S PC SOFTWARE MANUAL V6.2 CERSA-MCI

SONOFLOW Monitor Short Instructions. For SONOFLOW Sensors of the Series CO.55 V2.0

Screen Designer. The Power of Ultimate Design. 43-TV GLO Issue 2 01/01 UK

BoxCar Pro 4.3 for Windows

VarioAnalyze. User Manual. JENOPTIK Group.

5/2 HMI Brilliant Displays of Processing Sequences

Quick Start Guide. v1.1. Copyright 2011 AVID Technologies, Inc. Twinsburg, Ohio USA All Rights Reserved

Horizon Software. Bulletin 200A

Note: You must already be enrolled and issued with a Username and Password

C-322. Model. Instruction Manual. Datalogging Sound Level Meter. reedinstruments. www. com. Tripod sold separately (Model BS-6)

1 Marks: 1 Which of the following connectors is used with fiber cables? Choose one answer. BNC IEEE-1394 RJ-45

Homeschool Enrichment. The System Unit: Processing & Memory

USER S MANUAL. Data Logger SOUND LEVEL METER.

SI-100 Digital Microscope. User Manual

Product: ST-Win Basic

EXPLORER. Industrial Panel PC - Flexible Modular Design

RS-200-RPS-E 2U Rackmount System with Dual Intel

testo EasyClimate Software Instruction manual

Introduction.

DAQ-System for DynoWare

A+ Suite Software. User Manual

SD Card CopyStation. The Ultimate High-Speed Solution

PowerView for the EnergyPro

User s Manual. CW500Viewer IM CW500-61EN. 2nd Edition

m+p Analyzer ereporter

15/09/15. Introduction to Computers & The Internet. Contents. Computer hardware and software. Input and output devices CPU. Memory.

FUNCTIONS OF THE GSW PROGRAM

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro

Complete Control Software for Bitrode Laboratory Test Equipment LAB CLIENT

TAI Indicator Database User Instructions for Version 1.0

System Requirements Operating System Windows XP, Windows Vista >512 MB RAM CPU speed >2,5 GHz CD-ROM drive USB or parallel interface Important

This is a learning module for a specific Learning Outcome as stipulated in the HSP that is :

INFORMATION AND COMMUNICATION TECHNOLOGY

PSA-Manager Version 3 User Manual

Portable Data Recorder HMG 1000

1 Technical Specification IM10R-10

FUTEK USB Software Version User s Manual

Intel /100Mbps Ethernet Controller 32bit PCI Slot x2. ATI Rage XL Video Chip with 4MB Video RAM onboard 64bit PCI Slot x4

TPEditor User Manual

METALLURGICAL MICROSCOPE

INSPECTpro. Electronics & Software. Mobile measuring and evaluation unit for process inspection and quality monitoring. Type /..

Hand-held thermometer Model CTH6200

TEMPERATURE AND HUMIDITY REGISTERING DEVICE MANUAL

SPRECON-E Display Editor

RS-232. ital Measurement Metrology, Inc ECISION IS OUR VISION LEVEL REC SETUP MAX MIN FAST SLOW INTV CLOCK.

SUMMARY. Minimum required configuration... Software installation... User logo customisation... Software Un-installation... Launching application...

PowerBrick-CV User s Manual Edition 2.0

Kraus Messtechnik GmbH Gewerbering 9, D Otterfing, , Fax Germany Web:

Hand-Held Pressure Indicator

SCT 3000 Smartline Configuration Toolkit Model SCT 101 Specifications

IML-RESI F-Series. Electronic. F-Tools F-Tools Pro. Manual. Issued

MODEL.6715 DATA ACQUISITION SOFTWARE INSTRUCTION MANUAL

USB 3.0 Docking Station

USB Instruments EasyLogger for PS40M10 "Swordfish" Help

CLAMP-ON Graphic Power Quality Analyzer. Software Users Manual v3.4

DT Measure Foundry TM is a powerful software package designed for test and measurement,

Said the program supports UT330 A, B, C three models

Lab Determining Data Storage Capacity

Monitor Application for Panasonic TDA

Introduction to Computers

Compaq Evo D310 Micro Desktop

PC Software R&S FS300-K1

Installation Guide. Version 4.2. NextView 4. Installation of the software components Server, Workstation and Client API

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

Chapter 2: Installation

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

Digital Micro-measure Camera BW1008 Series. User Manual. BW1008 Series Digital Micro-measure camera is a slim type

Welcome In this chapter

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

INDEX PART 1. BASICS...

SPECIAL SPECIFICATION 1432 Computer Equipment

Transcription:

HCC-F Software Honigmann Computer Control - Precision Friction Meter The HCC-F software, used in conjunction with the Honigmann µ-meter, provides automated, precision measurement of the coefficients of friction at fibers and yarns. Running on the Windows platform, the HCC-F offers complete, high-level functionality for Controlling the Honigmann HCC µ-meter, the FAG 478 thread take-off device and other peripheral units, Online measurement data capture and evaluation, Automatic documentation and output of the results. HCC-F makes available to the operator all the advantages of a graphic user interface. Thanks to automatic sequencing the control functions, measurement processing and, ultimately, the presentation of the results can be handled quickly and efficiently, with a minimum of operator effort. The concept behind the overall system is consistently targeted on working to the specific testing standards (e.g. ASTM) and quality standards (e.g. DIN/ISO 900x). When recording the individual measurements not only the final results will be stored but all the peripheral parameters, as well, such as the F 1 and F 2 tensile forces, take-off speed, measurement period, date, operator identification, temperature, relative humidity etc. Honigmann Industrielle Elektronik GmbH Krebsstraße 2-8 D-42889 Wuppertal / Germany +49-202-622026 +49-202-63568 info@honigmann.com www.honigmann.com

Controls Before any measurement routine is started, the set-point values and other control parameters are loaded from files already on hand, edited if necessary, and then displayed in the Set points screen. These parameters remain visible during the entire measurement process (left-hand edge of the enclosed screenshot). The adjustment ranges: Tension Input F 1 5... 37 cn Thread take-off speed 0... 200 (... 800 ) m/min Measuring time 30... 900 s Angle of contact 30... 3x180 Pre take-off speed 0... 200 (... 800 ) m/min Pre take-off length 0... m Pre take-off time 0... s Speed for stick-slipmeasurement* 0.01... 60 mm/min Temperature of friction 30... 200 C body * Spin finish pump 0... 60 1/min rotation speed * Digital buttons signal the momentary operating status and make it possible even online and while measurement cycle is running to switch individual devices and functions on and off. Several sets of parameters can be stored in a queue, one behind another. They are then executed automatically as a measurement series. Thus it is possible to run a series of tests using differing speed, temperature and tensile force profiles. An individual comment can be added to each parameter (and to each measurement). Whenever the program is launched, pre-defined comments will be loaded; these comments contain the guideline values recommended in the ASTM standard. * Provided that the appropriate functional module is installed at the HCC µ-meter TDE HCC-F 06-05 www.honigmann.com 2

Measurement data capture and online depiction The measured data are captured at a sampling rate of 200 measurements per second, at resolution of 12 bits. Shown in parallel, during the measurement, are the set-point value and The actual value for tensile forces F 1, F 2 and electrostatic buildup - In analog form as a y(t) chart ( upper display area ) and - Digitally as a mean value over the previous 300 ms The friction value µ calculated online - In analog form as a y(t) chart ( lower display area ) and - Digitally as a floating mean value over 300 ms The actual values for the following parameters ( shown digitally, in the right hand frame within the screen ) - Thread take-off speed - Stick-slip speed * - Temperature of the friction body * - Finishing pump rotation speed * - Room atmosphere * ( ambient temperature and relative humidity ) Status information on the switching states for the devices Information on the momentary software operation status All the measured values are stored as the original values, without data compression, together with the associated measurement parameters, the comments and the statistical values. This makes it possible to call these data once again, whenever it may be required, and to carry out further assessments in accordance with the state of the art valid at any given date. In addition, this makes for simple reconstruction of the measurements at any time. * Provided that the appropriate functional module is installed at the HCC µ-meter TDE HCC-F 06-05 www.honigmann.com 3

Analysis capabilities and statistical evaluations Once a measurement has run to completion the data captured for tensile forces F 1 and F 2, for the electrostatic charge* and for the calculated friction value will be evaluated statistically: Mean value Maximum Minimum Standard deviation or coefficient for standard deviation c v In addition to the evaluations described above, the HCC-F software offers further outstanding analysis options. Parameterization within the limits imposed by values which make good mathematical and physical sense can be specified as desired. Zoom function for both display areas, in the t and y directions Recalculation of the mean value across the zoomed sector Recalculation of the peak values across the zoomed sector Cursor functions with the current cursor position displayed Complex evaluation of the stick-slip signal* Exact calculation of all the individual stick-slip maximum and minimum values Calculation of the envelope curve for maximum and minimum values as a 3rddegree spline function Automatic cursor function for maximums and minimums Maximum, mean and minimum values for all extreme values Calculation of the envelope curves as spline functions Separate display for selected charts FFT analysis** Filter functions with adjustable cut-off frequencies Each measurement can be provided with an individual comment. * Provided that the appropriate functional module is installed at the HCC µ-meter ** FFT: Fourier transformation depiction of the frequency and amplitude spectrum TDE HCC-F 06-05 www.honigmann.com 4

Output options for measurement and analysis values The following output options are available for documentation purposes and to export the results: Direct output of the analysis screen content (color or B/W) to an ink-jet or laser printer Generating bitmap files (*.bmp) for post-editing using MS Paint or MS PowerPoint, for example Label printing, at present with 10 user-selectable measurement and analysis values in 5 lines header / free text for each line 2 free editable texts Measurement: Material Test 0235 friction mean 0.2034 cn F2 mean 35.987 cn µ max/min 0.307 / 0.105 cn speed 80.0 m/min F2 Std. dev. 1.245 cn 12.10.2002 User: demo TDE HCC-F 06-05 www.honigmann.com 5

Generating files (*.xls, *.txt) for editing and further processing of the data with other programs, such as MS Excel TDE HCC-F 06-05 www.honigmann.com 6

Minimum PC system requirements computer: Pentium III, 500 MHz, 128MB-RAM hard disk 4GB monitor and graphic card: min. 768 x 1024, 256 colours keyboard and mouse required plug-in space: 2 PCI-slots CD-ROM housing: standard desktop or miditower housing (no slim-line housing) inclusive original operating system: Windows 2000, Windows XP, German or English version inclusive installation programs for all accompanying drivers (i.e. for monitor, graphic card etc.) other periphery: usual Windows standard Note: Our equipment is normally designed for power supply 230 V AC / 50 Hz. Should you require 115 V AC / 60 Hz, please state so explicitly in your order. TDE HCC-F 06-05 www.honigmann.com 7