CB ELECTRONICS TC-4 PORTABLE LTC READER/GENERATOR

Similar documents
VS-Link. Dos Version. CB Electronics

CB ELECTRONICS. P2MMC RS422-Midi Machine Control Interface

TC-5 Generator/Reader/Converter LTC-Midi-USB

Euphonix Machine Control Systems

Q2Midi Convert Cue Lists to Midi Files

Using the ProTools PD-1 Session Template

* Option 1... High Profile Jog Wheel

Use with the TMC-1Reference

Pec - Direct Remote For DAW's (Revision 2 Software)

CB Electronics PDStem Windows/Mac Stem Definition s/w

Pec - Direct Remote For DAW's (Revision 2 Software)

USB422V. Dual RS-422 USB Interface with Video and GPO. Main Features

CLOCKIT CONTROLLER ACC501

Timecode Transcoder. Artistic Licence (UK) Ltd. Software Version V3.2 Manual Revision V1.07

Clockit Timecode ACC 501 Controller

JANUARY 2000 TS800A TS801. MicroScanner

USB-5100 Series Multi-Channel Data Loggers

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Lockit Timecode Controller

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

ACN Antenna: for wireless sync with other Lockits. Lemo Connector: TC (and metadata) interface. Status LED. Green Button Red Button Power Button

UC-2000 Installation Manual Unicorn Computers Technology Limited

DS1306. Serial Alarm Real Time Clock (RTC)

Sheet Resistance Meter. Model SRM 232 MODE SELECT STORE SURFACE RESISTIVITY METER SRM-232 POWER. Operator s Guide

TC-7530DC with BMI-10

TC100 Precision Thermocouple Calibrator

Model 8702 DP-CALC Micromanometer

MegaAVR-DEVelopment Board Progressive Resources LLC 4105 Vincennes Road Indianapolis, IN (317) (317) FAX

DN9680. I/O Interfaces. 8 Port AES50 Extender and Multiplexer with up to 1000 Metre Range

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

W0EB/W2CTX Software Operating Manual for the MicroBITX Transceiver Using A Teensy 3.6 Micro-Controller

Owner s Manual Revision 4.01 Option 1

Mega128-DEVelopment Board Progressive Resources LLC 4105 Vincennes Road Indianapolis, IN (317) (317) FAX

DS1305. Serial Alarm Real Time Clock (RTC) FEATURES PIN ASSIGNMENT ORDERING INFORMATION

DS1305 Serial Alarm Real Time Clock (RTC)

328 XD TASCAM DTRS STEREO INPUTS. 0dBFS = 18dBu. MIX dbfs RIGHT SELECT MUTE AES/EBU SOLO EXIT FUNCTION S/PDIF PARAMETER CLOCK CLOCK IN OUT IN MIDI OUT

3000 SERIES LOW PROFILE FLOOR SCALE.

DPM Digital DC Power Meter with Data logging capability. User Manual

DS1305EN. Serial Alarm Real-Time Clock

Chronomax Time Switch

DS1302. Trickle Charge Timekeeping Chip FEATURES PIN ASSIGNMENT PIN DESCRIPTION

KNJN I2C bus development boards

AANDERAA. DATALOGGERS 3634 and 3660

Display Real Time Clock (RTC) On LCD. Version 1.2. Aug Cytron Technologies Sdn. Bhd.

USB-4303 Specifications

Series 3000 User Manual and Product Features

IVC-222HPII Precision Voltage/Current Calibrator

HygroPalm 0. Portable Humidity Temperature Indicator. Instruction Manual

VIS-3200 / VIS-3201 User Manual

Surface Resistivity Meter. Model SRM 232 MODE SELECT STORE SURFACE RESISTIVITY METER SRM-232 POWER. Operator s Guide

DL6 Data Logger. Quick Start Guide Version 1.2. Delta-T Devices Ltd

BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013

USB-5100 Series Multi-Channel Data Loggers

SY021 Portable Load/Force Meter User instructions

ESS-2000 with Discharge gun TC-815P

SMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL

Introduction. Chapter 2

Specification for Portable Laptop Battery Detector

DS1215. Phantom Time Chip FEATURES PIN ASSIGNMENT PIN DESCRIPTION

SPRITE. Operations manual. VRM10 Digital Audio Variometer. Recorded alarm messages including undercarriage warning

Security Door Controls

AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS

Allen-Bradley Real Time Clock Module (Cat. No DC)

ATRT-03 S2, ATRT-03A S2, and ATRT-03B S2 THREE-PHASE TRANSFORMER TURNS-RATIO METERS

Homework 5: Circuit Design and Theory of Operation Due: Friday, February 24, at NOON

PROGRAMMABLE POWER SUPPLY

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

DS1305EN. Serial Alarm Real-Time Clock

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

For Powerful Digital Marketing and Total Multimedia Solution DV-6664 & DV-6664T. User s Guide version 1.0

Introduction 1. Liquid crystal display (16 characters by 2 rows) Contrast dial: turn the dial to adjust the contrast of the display (see page 5)

DS1216 SmartWatch RAM DS1216B/C/D/H SmartWatch ROM DS1216E/F

user s guide Basic Instructions

Hello, and welcome to this presentation of the STM32 Real- Time Clock. It covers the main features of this peripheral, which is used to provide a

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual

AXE033 SERIAL/I2C LCD & CLOCK

Shack Clock kit. U3S Rev 2 PCB 1. Introduction

Electronics. CB Electronics Specialists in Timecode, Bi-Phase & Serial Control

Model 305e OEM CO 2 concentration sensor

PAC1 Door Access Controller

PAC1 Door Access Controller

Strain Gage Measuring Amplifier GSV-1

HPM Series - Sensor Recognition

KNJN I2C bus development boards

Bale Wrapper Controller (RA)

AWA6223S Sound Level Calibrator. Instruction Manual HANGZHOU AIHUA INSTRUMENTS CO., LTD

SYRDBT. SYRIS Handheld bluetooth RFID Reader

Broadcast A/V Division V-SG4K-3G. HDMI / SDI Portable Signal Generator. Operation Guide

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

CORI-GPS GPS CURRENT INTERRUPTER USER S MANUAL RCS PN MANUAL REV B

TC200 Operation & Installation Guide. Revision 1.0

Full Color Digital Scouting Camera. User s Manual HCO ScoutGuard SG560C

TeamConnect SL TeamConnect CU1, Central Unit, SL TeamConnect CB1, Combox

NS1 Connection Unit Guide

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Digital Room Thermostat

USB-500/600 Series Low-Cost Data Loggers and Accessories

Transcription:

CB Electronics TC-4 CB Electronics Loddonside, Lands End House, Beggars Hill Road, Charvil, Berks RG10 0UD, UK Tel: +44 (0)118 9320345, Fax: +44 (0)118 9320346 URL: www.colinbroad.com E-mail: support@colinbroad.com

CB ELECTRONICS Loddonside, Lands End House, Beggars Hill Road, Charvil, Berks RG10 0UD, UK Tel: +44 (0)118 9320345, Fax: +44 (0)118 9320346, www.colinbroad.com TC-4 PORTABLE LTC READER/GENERATOR * TEMPERATURE COMPENSATED CRYSTAL. Accuracy approx. 1 frame a Day * MULTI-STANDARD GENERATOR... EBU, SMPTE, DROP, FILM * INTERNAL IN REAL TIME CLOCK... Time of Day on Switch on * AMPS. RECOMMENDED USER BIT ASSIGNMENT... Date, Month, Unit, Reel * AATON FORMAT... Date, Month, Year, Production * BURST MODE... 1..99 Frame Timecode Burst on Record Command * JAM GENERATOR FROM READER... Accurate to 1/80th Frame * LCD DISPLAY... 16 Character Display * LONG BATTERY LIFE... 50+Hours on a 9 volt Alkaline battery * 5 PIN LEMO IN/OUT CONNECTOR... Aaton/Nagra Compatible * ADDITIONAL OUTPUT CONNECTOR... Phono * LIGHT WEIGHT... 100gms Including Battery * SMALL SIZE... 125x65x25mm * EXTERNAL 12 Volt INPUT... Via the Lemo connector OPTIONS * VIDEO SYNC OUTPUT... 5vComposite Black The TC-4 is designed as a Master/Slave location timecode Generator, When switched on the generator is preset with the current Time, Month, Date, Reel number and Unit number. A 16 character LCD display enables the user to check all parameters easily. CB Electronics TC-4 Reader Generator TC-4/ 1

TEMPERATURE COMPENSATED CRYSTAL The Monolithic Digital Temperature Compensated Crystal Oscillator (DTCXO) is accurate to 1 part per million over a temperature range of -30 C to +85 C. This translates to multiple TC-4 units maintaining a relative accuracy of 1 frame per day providing that all units are left ON! For multiple TC-4 to keep the same time, one should be designated master and be used to set the others. REAL TIME CLOCK The internal real time clock is powered by a separate ni-cad battery and uses a standard 32KHz watch XTAL. The clock chip is designed to consume very low power and will run for several months without the unit being switched on. When the unit is switched on the current TIME and DATE are read from the clock chip and the generator is set to the nearest second. To preserve battery life this is not run from the temperature compensated crystal and does not have the same accuracy. USER BIT ALLOCATION Timecode USER bits are split into eight 4 bit groups. The generator user bit groups are allocated as follows:- AMPS DAY User Groups 1&2(Hours) MONTH User Groups 3&4(Minutes) UNIT User Group 5 (Seconds Tens) REEL User Group 6, 7 & 8 (Seconds Units & Frames) All data except the UNIT number is stored as BCD so that it can be read on a standard reader display. AATON DAY User Groups 1&2(Hours) MONTH User Groups 3&4(Minutes) YEAR User Group 5&6(Seconds Tens) PRODUCTION User Group 7&8(Frames) BURST When Burst is enabled (Set BURST to a non-zero Value) a 0v input on the Record Switch input will enable the timecode output for BURST frames. Whist the Timecode burst is output the BURST RELAY DRIVE output is taken to +5v. JAM Jam will be enabled when the TC-4 is Switched to Reader or after 8 frames without code. The Generator phase and data will be updated from the next reader timecode frame, JAM will then be disabled. At this point the generator TIME, MONTH, and DATE will be set from the reader data. The Unit number and Reel Number will not be changed! The Generator phase is set to an accuracy of 1/160th of a frame. By setting Multiple TC-4 s from a single unit an initial accuracy of 1/80th of a frame may be obtained. LCD DISPLAY The user may select and display any of the following :- READER/GENERATOR RANGE:- GEN DISPLAY DATE & TIME GYYMMDD HH:MM:SS REEL NUMBER & TIME 0-999 GRL-??? HH:MM:SS UNIT NUMBER & TIME 0-F GUNIT-? HH:MM:SS CB Electronics TC-4 Reader Generator TC-4/ 2

STANDARD & TIME 24, 25, 29, 30 GSTD-25 HH:MM:SS The Left hand key selects Reader or Generator as designated by the first letter on the Display (R=Reader, G=Generator). The Right hand key selects the display mode. STANDARDS The TC-4 may be set to any of the following timecode standards:- GSTD-25 25 frame per second EBU timecode. GSTD-30 30 frame per second SMPTE NON-DROP timecode. GSTD-24 24 frame per second FILM timecode. GSTD-29 29.97 frame per second SMPTE NON-DROP timecode. GST-29D 29.97 frame per second SMPTE DROP FRAME timecode. Note: GSTD-29 will not keep real time, but will drift by 108 frames per hour. Entering and leaving setup will set the clock incorrectly. BATTERY LIFE The TC-4 consumes approximately 10mA, when the battery voltage drops below 5.5 volts the LCD contrast will change. At this point we recommend that the battery is changed at the next convenient time. However the unit will continue to generate timecode even when the LCD display is no longer visible. The following table shows nominal battery performance, battery life is dependant on load and frequency of usage, a Zinc/Carbon or Zinc Chloride battery will last longer used for 4 hours a day than if used for continuously.:- TYPE CAPACITY LIFE COST /HOUR Ni-Cad 0.11Ah 10 Hours 5.00 Rechargeable Zinc Carbon 0.27Ah 22 Hours 0.90 0.040 Zinc Chloride 0.38Ah 32 Hours 1.30 0.041 Alkaline 0.53Ah 50 Hours 2.60 0.052 Zinc Air 1.50Ah 136 Hours 7.50 0.055 Use Zinc Air batteries for longest battery life and Zinc Chloride for best cost performance. The TC-4 is supplied with a Zinc Chloride battery. If the video output option is fitted then the battery life will be reduced by approximately 20%. CB Electronics TC-4 Reader Generator TC-4/ 3

LEMO CONNECTIONS 1 Ground 2 Timecode Input 3 Not used 4 12 volt input, the TC-4 will operate between 6& 30 volts 5 Timecode Output SETUP 1) In the normal mode select the display to setup, Time and Date, Reel Number, Unit Number or Standard. 2) Depress both keys simultaneously (Left Key, followed by Right key) to enter setup, then release both keys. 3) Use the Left hand key to move the cursor (time, date or reel). 4) Use the Right hand key to increment the selected number. 5) Depress both keys simultaneously (Left key, followed by Right key) to leave Setup, then release both keys. Note: On leaving setup there will be a 1 bit drop-out on the timecode output. APPLICATION TIPS 1) When you have to set the time on more than one TC-4, first set up one unit and then use that unit to Jam the other TC-4 units. By entering and leaving setup on the TC-4 the data from the generator is transferred to the real time clock. To set the clock after JAM enter and then exit the SETUP mode by depressing both keys simultaneously. 2) If you enter setup and wish to leave without setting the clock then turn the TC-4 off and then on. 3) To reset the unit to the current time of day after jam: turn switch the unit off and then on. CB Electronics TC-4 Reader Generator TC-4/ 4