F1000 User's Manual. (Version: V1.01)

Similar documents
MT-8000 series. MT-8056T/ MT-6056T Installation Instruction. 1.0 Installation and Startup Guide. 2.0 Installation Instructions

MMI8000 Series. MMI8056, MMI8070, MMI8080, MMI8100, MMI8104, MMI8121 Installation Instructions

MT-600/8000 series. MT-607i MT-8070iH / MT-6070iH Installation Instruction Installation and Startup Guide. Where Used

emt3000 series emt-3070a Installation Instruction 1.0 Installation and Startup Guide 2.0 Installation Instructions 2.1 Mounting Instructions

MT8050iE series. Installation Instruction (1) (2)

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

MMI-1500 Series. MMI-1500T and MMI-1500M. Installation Instruction. 1.0 Environmental Considerations See Specifications for environmental constraints.

See instructions to download and install the latest version of LinkBoxMB and the user's manual at


See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

1. Safety Precautions (Read these precautions before use.)

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

HEC. General Operating, Maintenance and Installation Manual

Machine TV Interface. mtv-100. Memory Processor. I/O Port RTC. Power. Specification. Certificate Software

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

EX-RC1 Remote I/O Adapter

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

PanelView Plus/VersaView CE Terminals and Display Modules

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

EX-RC1 Remote I/O Adapter

8806 Series. 15 Multi-functional Touch Panel PC. Quick Reference Guide

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

T1K MODBUS Base Controller Specifications

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.


Features. Intel 45nm Atom Processor N270: 1.6 GHz

MC 11 EB-2 Power supply cabinet with external bus, AC version

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

EZ864 UMTS Terminal Telit Cellular GSM Engine

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

Package Contents. GP Options (Made by Digital)

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.

EX-RC1 Remote I/O Adapter

SoundwebTM. Installation Guide

PWS6500. Installation and Operation manual. English MAEN

User Manual. cmt-iv5 Startup Guide

2 Mesa Ethernet Dock User s Manual

COGNEX. Checker SensorView. Quick Reference Guide

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

PWS3260 Installation Guide

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Evo2. Free programmable room controller. Summary

GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2

SCC-RLY01 Relay Module

Performance, Design, and Versatility MT8000iE XE mtv ip Series

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

User Manual. cmt-svr Startup Guide

MGate 4101-MB-PBS Series

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

FEATURES FEATURES. Macro Function Usage Supports strong Visual Basic script language which includes more than 500 built-in functions.

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

1. Safety Precautions (Read these precautions before use.)

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

TRC-190 User s Manual

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

Features and Benefits. Certifications

H-T60. Installation and Operation Manual. English MA

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

LED W RGBA User Manual

SCC-AO10 Isolated Analog Output Module

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

User safety and equipment protection guidelines

PWS6300. Installation and Operation manual. English MAEN

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

MT-6000/8000 series. MT-6050i & MT-8050i Installation Instruction Installation and Startup Guide. Where Used

GT- IRDM-9603 Product description Rev. 2 17/06/2014

V E2B Snap-in I/O Module

User Manual. cmt-iv5 Startup Guide

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

CP420. Installation and Operation Manual. English ABB, 1SBC159102M

Installation Instructions for UL Rev A

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

V E1B Snap-in I/O Module

General Operating, Maintenance and Installation Manual

AX3000 Platine Terminal Ethernet TCP/IP

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

TM221CE40R controller M IO relay Ethernet

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

AX3000 Platine Terminal Ethernet TCP/IP

Features and Benefits. Certifications

Installation Requirements for Conformance to Standards

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

UniStream HMI Panel. CPU-for-Panel

QTERM -A7 TERMINAL HARDWARE MANUAL

FEATURES DESCRIPTION GENERAL SPECIFICATIONS

Thermocouple Input Module Product Specifications and Installation Data

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

Transcription:

(Version: V1.01)

Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions... 3 2.2 Power connection... 4 2.2.1 Power requirements... 4 2.2.2 Grounding requirement... 5 2.2.3 CE Requirement... 5 2.2.4 Safety Guide... 5 2.3 Communication connection... 7 2.3.1 Connection with external device... 7 2.3.2 USB interface... 8 2.3.3 Cable... 8 2.4 Requirement... 9 Chapter 3 Specification... 10 3.1 Hardware Specification... 10 3.1.1 Hardware Specification for F1070... 10 3.1.2 Hardware Specification for F1100... 11 3.2 Common Specification... 12 3.2.1 Common Specification for F1070... 12 3.2.2 Common Specification for F1100... 12 Chapter 4 Dimension... 13 4.1 Dimension for F1070... 13 4.2 Dimension for F1100... 14 1

Environment Chapter 1 Overview F1000 series is designed according to the application environment of industrial products. It can stably work in the most industrial environment. However, it may not be used in some specific environment, if you need to use special occasions in the outdoor, please be sure to ask your provider! NEMA The front panels of F1000 series products meet the NEMA4 protection regulations. When the product is properly installed in accordance with the panel on NEMA4 protection regulations, the cabinet still remain in compliance with the provisions of NEMA4, that to say, when the panel surface spray liquid, the liquid can t penetrate into the inner of disk cabinet. Electrical environment The products have passed the test to demonstrate compliance with European CE Electrical Certification Standard, that to say, the interference circuit design of products can resist electrical noise, but this is no guarantee that it may be exempted from all cases. The correct wiring and grounding mode can ensure the use. Mechanical environment To ensure that your correct use, please avoid installing the product in the presence of strong mechanical vibration environment. 2

Chapter 2 Installation 2.1 Installation guide 2.1.1 Installation position Please keep distance between the product and the interface of electric equipment, such as AC power cord, the PLC output module, contactor, starter, relay, and so on. Please especially caution that keep distance with the variable frequency speed governor and switching power supply. Because this kind of devices input and output cable must be shielded cable, and the shielding net access to system s star ground. 2.1.2 NEMA4 standard installation Cabinet details F1000 series product can be installed at a depth of more than 105 mm, we recommend you install the product at the front panel of the cabinet. To ensure that normally open the front panel of the cabinet, please keep at least 25 mm distance around the installation products. NEMA-4 installation Puts the product into the mounting holes, and then respectively screw the 4 screws into the screw fixing hole from the back of panel, then tighten the screws one by one, till the product is firmly fixed on the panel. [Caution] Do not be too hard to screw the screws! Installation standard To ensure compliance with the seal specification of NEMA4, all mounting screws is provides with the product must be used, and the installation panel bending cannot be over 0.010. 2.1.3 Environment precautions Because the built-in LCD display panel, F1000 series product are restricted to indoor use. Please ensure that the product is installed correctly, and the environment is in accordance with the constraints of hardware specification (for details, please refer to the hardware specification). Do not use in hazardous situations, such the flammable gas, the steam, the dust. Do not use in great changes of temperature or humidity, it may lead to internal device condensed water, resulting in damage to the device. 3

2.2 Power Before installing the product, please ensure the power supply is consistent with the electrical standard of the local and the country, for the details please consult the local suppliers. 2.2.1 Power requirements Power To be compatible with most DC power supply, F1000 series product can only use DC power supply, the regulations range of DC voltage is19.2 V ~28.8 V. The product internal power conditioning circuit is completed by the switch power supply, the peak of starting current can achieve 700mA. High voltage the internal of products have the power supply isolation protection function, it works when the power voltage is too high, but this doesn t ensure that the internal electronic components are not damaged. DC power supply must be correctly isolated from AC main power supply. Emergency stop switch to meet the ICS security recommendations, you must install the emergency stop switch in any control system of F1000 series product. Power status never use the same power with perceptual load or the input circuit of the controller. [Note] Some controller provide 24V output DC power, cannot provide normal current for F1000 series product. Wiring DC power supply lines should be as short as possible: Shielded cable is not more than 500 meters; the common twisted pair is not more than 300 meters. The power cables suggest using the twisted pair cable. If the power cable will be exposed to lighting environment, please use the lighting protection measures appropriate or proper installation lightning protection device. Please be sure to AC power cable and high energy with fast switching away from the communication signal cable. To provide relief channel to static electricity and high frequency interference, please parallel connect a resistance or a capacitance between no grounding DC power and the earth. Generally, the resistance value is 1MΩ, the capacitor capacity is 4700pF. 4

Connection The end of the cable crimping terminal is used to 3/8 insulation when connect the power cable (recommend to use the forked terminal). Counterclockwise screw the screwing in the product back, insert the power cable with the crimped terminal, and then clockwise screw the screws. The power positive must connect to the terminal marked with 24V, the DC grounding connect to the terminal marked with 0V. 2.2.2 Grounding requirement Product shell must be grounded. The DC grounding is not connected to the earth in the product internal. To avoid the virtual point grounding caused by external noise into the system, it is best not to the DC grounding and shell connect to the earth, but if must grounding to the star ground, it is ensure that the conductor grounding as a short length, cross-sectional area as large as possible. The conductor must be able to withstand the maximum short-circuit current, and it must be directly connected to star ground, so that, the grounding conductor will not bear the other branch current. 2.2.3 CE Requirement To comply with the EMC specification, and reduce the electrical noise interference, the grounding terminal at the product shell must be ground cable with a separate #14 AWG specifications, it should directly connected to the system ground star follow the installation introduction. 2.2.4 Safety Guide This section introduces the recommended installation practices and procedures. Although no two-application cases are same, please carefully read the following suggestions before installation. 5

Hardware System designers must understand that there may be some unsafe factors from the failure of the control system device, and the electrical conflict in the operation interface could cause the device to start, this may lead to a certain degree of damage to the operator. If you or your company needs the operation interface when use a programmable control system, you must understand the potential security risks and take some appropriate preventive measures. Although your detailed design steps are constituted according to your specific application, you need to pay attention to the general prevention matters about installing programmed control firmware. These precautions meet NEMA ICS 3-304 control standard. Program Attention To meet the security proposed of ICS, you must check whether the program exist safety constraints about the can-write register of hazardous parts. Moreover, to ensure personal safety, the device must be equipped with an emergency stop. ICS 3-304.81 safety recommendations: Carefully consider the function of the emergency stop; it must be independent of the programmable controller outside. In the operator can directly contact mechanical position, such as loading and unloading machine tool position or the machine automatic-run position, you must carefully consider the function of the manual device or the other alternate method. It needs to be independent of the programmable controller outside, can automatic start or stop the system. If you need to modify the program in the system-running situation, you should take measures to ensure the modification is the necessary. *These suggestions are to prevent the risk of device failure. ICS3-304.81 safety recommendations is in the permission of the NEMA, and copy from NEMA ICS 3-304 standard. 6

2.3 Communication You can see the communication port on the back of the shell, can be used to connect such as PLC or external devices. 2.3.1 Connected with external device Cable requirements With different external devices should be connected different communication cables. [WARNING] Never plug communication cable when the device power on. Attention To avoid the problem of communication, please pay attention to that: the length of communication cable with the connection of RS485 is no more than 150meters; the length of communication cable with the connection of RS232 is no more than 15meters. When the communication cable is too long or the communication cable needs to through the electrical noise environment, you must make the communication cable by the shielding cable. Do not wire the communication cable and AC power cable together or wire the communication cable near the position of electrical noise source. Please ensure that both ends of the connector communication cable and communication port is connected closely and fixation. Pin configuration There are two DB9 ports on the F1000 series product, one is D-type male port, and the other is D-type female port. The male port is COM1 and COM3 of the RS232, as shown in the following table. Pin COM1[RS232] COM3[RS232] 1 Not used 2 RxD 3 TxD 4 TxD 5 GND 6 RxD 7 RTS 7

Pin COM1[RS232] COM3[RS232] 8 CTS 9 Not used The male port is COM2 of the RS232 and RS485; it supports 2-pin RS485 and 4-pin RS485, as shown in the following table: Pin COM2[RS485]2w COM2[RS485]4w 1 Data- 2 3 4 Data+ 5 6 Rx- 7 Rx+ 8 Tx- 9 Tx+ 2.3.2 USB interface Standard USB 2.0 interface can connect many devices, such as the mouse, the flash memory disk, USB HUB. Moreover, Mini USB can be used for downloading. 2.3.3 Cable F1000 Ethernet RJ45 1TX+ 2TX- 3RX+ 6RX- PC RJ45 3RX+ 6RX- 1TX+ 2TX+ 8

2.4 Requirement CE criterion The provisions of EMC about counteracting the electromagnetic radiation: 89/336/EEC, 92/31/EEC, 93/68/EEC. The provisions of the mechanical structure about machinery safety: 89/392/EEC, 91/368/EEC, 93/44/EEC, 93/ 68/EEC. F1000 series product use CE markers to conform to EMC. The design of the F1000 series product can work well in the electromagnetic noise environment without electromagnetic radiation noise. The products meet the European standard for electrical safety by the correct installation. Compatibility The design of the F1000 series product meet the electromagnetic compatibility in the industry environment, the items are as follows: CISPR (EN 55011) Group 1, Class A Radiation levels EN50081-2 industrial environment common radiation standard (be equivalent to USA FCC Class A Standard) EN50082-2 industrial environment common resistance standard 9

3.1 Hardware Specification 3.1.1 Hardware Specification for F1070 Chapter 3 Specification Display Lightness Color 7 TFT LCD 300 cd/m2 65536 colors Contrast ratio 500:1 Resolving power (WxH dots) Backlight Backlight life (Average) Touch panel Touch accuracy I/O Communication port Ethernet port 800x480 LED 30,000 hr 4 pin analog resistive touch screen Active Area Length(X)±2%,Width(Y)±2%, COM1(RS232), COM2(RS485/2W,RS485/4W), COM3(RS232) 1 Ethernet port(10/100 Base/T) USB USB Host port x 1,USB Client port x 1 CPU Flash Memory DRAM SD Card Slot Real-time clock 32bit RISC CPU 400MHz 128M 64M DDR2 on board YES Built-in 10

3.1.2 Hardware Specification for F1100 Display Lightness Color 10 TFT LCD 300 cd/m2 65536 colors Contrast ratio 500: 1 Resolving power (WxH dots) Backlight Backlight life time(average) Touchscreen Touch accuracy I/O Communication port Ethernet port 800x480 LED 30,000 hr 4 wire, analog resistive Active Area Length(X)±2%,Width(Y)±2%, COM1(RS232), COM2(RS485/2W,RS485/4W), COM3(RS232) 1 Ethernet port(10/100 Base/T) USB USB Host port x 1,USB Client port x 1 CPU Flash Memory DRAM SD Card Slot Real-time clock 32bit RISC CPU 400MHz 128M 64M DDR2 on board YES Built-in 11

3.2 Common Specification 3.2.1 Common Specification for F1070 Input power CE Protection levels Temperature Humidity Shell material Overall dimensions Open hole dimensions Weight 24 ±20%VDC EN61000-6-2:2005, EN61000-6-4:2007 IP65, the front panel is circular sealing ring 0 ~45 10-90% RH (no condensation) Engineering plastics ABS + PC WxHxD 202x148x43mm WxH 192 x 138 mm About 0.7kg 3.2.2 Common Specification for F1100 Input power Power waste CE Protection levels Temperature Humidity Shell material Overall dimensions Open hole dimensions Weight 24 ±20%VDC 300 ma@24vdc EN61000-6-2:2005, EN61000-6-4:2007 IP65, the front panel is circular sealing ring 0 ~45 10-90% RH (no condensation) Engineering plastics ABS + PC WxHxD 270.5x212.5x52mm WxH 259 x 201 mm About1.3 kg 12

4.1 Dimension for F1070 Unit: mm Chapter 4 Dimension 13

4.2 Dimension for F1100 Unit: mm 14