Hypnos. User Manual. Order code: EQLED372

Similar documents
Blitzer Strobe. User Manual. Order code: EQLED366

Crossfire. User Manual. Order code: EQLED061

UV Power Flood. User Manual. Order code: EQLED029

Microbar COB System. User Manual. Order code: EQLED137

Fusion Saber. User Manual. Order code: EQLED070

Gobo Projector XP 80W

Blitzer RGB Strobe. User Manual. Order code: EQLED365

RGB Power Batten. User Manual. Order code: EQLED032

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

UV Spectra Batten 12 x 5W UV LEDs

CS2 DMX Distribution Splitter

Microbar Multi System

PF LED Profile. User Manual

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Performer 18 RGBWA MKII

Saturn Spot. User Manual. Order code: EQLED023

ZF LED Zoom Fresnel. User Manual

Slimline CW & WW Series

DMX LED Starcloth Systems

Vortex. User Manual. Order code: EQLED073

Vector Beam White. User Manual. Order code: LEDJ265

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

CDP 405 Digital Dimmer Pack

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

MICRON DJ Booth Tri-colour Starcloth

LIGHT BRICK - 12 X 3W TRI-COLOUR

IMPACT Order code: EQLED79

Endura 1Q120 RGBW COB Exterior Fixture

MICRON DJ Booth System with Overhead Kit & CW Starcloth

EasiLED 4 DMX Controller

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

Order code: EQLED53 User manual

order code: EQLED40 user manual

LEDJ Tri LED DJ Skirt Matrix Cloth - STAR17 USER MANUAL

w w w. p r o l i g h t. c o. u k STAGE PAR 64

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

Order code: EQLED60 USER MANUAL

Colour Burst Order code: LEDJ01 USER MANUAL

Fresco 24 RGBW. Exterior Fixture User Manual. Order code: LEDJ267

Intense 9P10 RGBWA LED Slim Par

Intense 9HEX10 LED Slim Par

Slimline 12Q5 Series

Flexoled FTP3HP RGB LED DMX Driver

Professional DMX Stage Backdrop

FTP1 Single Channel LED DMX Driver

Starlit Dance Floor. User Manual

order code: EQLA04 user manual

TRANSCENSION Show Control

User Instructions. American DJ

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

SP-1500 DMX MK II Strobe

CPA 40 Two Channel Amplifier

Heavy Duty DMX Mirror Ball Rotator with Safety Eye

50W/100W LED Alu. User Manual. Code: ELUM041-50W - (5600K) Code: ELUM041A - 100W (5600K) Code: ELUM041C - 50W - (3200K) Code: ELUM041D - 100W (3200K)

PowerGlide Multicolour sweeping beam effects

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

TDC Power Derby DMX LED light effect

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Party Dimmer IEC ORDERCODE 50324

LED PAR56 Order Code: P56-151

LED W RGBA User Manual

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

FLEX BEAM V8. User Manual Please read the instruction carefully before use

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

Multidim ORDERCODE 50391

xbrick Full-Colour 16 3W LED floodlight user manual

ALO Duo Roll DMX LED barrel scanner with dual light source

LED DANCING FLOOR User Manual

Octostrip ORDERCODE 42220

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

Robot Light V2. User Manual

LED Blinder 2 COB 2 65 W blinder. user manual

U S E R M A N U A L Mini n St S udi d o o Pa P r 7 x 4W RG R B G W

1 Channel Strobe Controller ORDERCODE 40226

MATRIX LED LED User Manual Please read the instructions carefully before use

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

Mover MicroSpot CKU (US) / CKE (EU) USER MANUAL

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

Flat Par 9 LEDs. battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL. Please read over this manual before operating the light

DDS-405 LC DMX 4 Ch. Dimmer dimmer pack. user manual

TourPro RGBAW Stagebar USER MANUAL

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

LED Accu Penta 9x12W RGBWAU

imove 50SR LED-MS50A User Guide Professional Entertainment Technology

BGS 20T 100V/8Ω Background Music Loudspeakers

LED Giga Bar 4. User Manual

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

Light Brick ORDERCODE 50370

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

User Manual Please read the instructions carefully before use

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

COLOR PAR 56 COLOR PAR 64. User Manual Please read the instructions carefully before use. Широкий ассортимент оборудования ACME на

Transcription:

Hypnos User Manual Order code: EQLED372

Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make sure that there is no damage caused during transportation. Should there be any damage, consult your dealer and do not use the equipment. To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual. Please note that damages caused by user modifications to this equipment are not subject to warranty. CAUTION! KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS CAUTION! TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!! IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment. Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution! Never remove warning or informative labels from the unit. Do not open the equipment and do not modify the unit. Do not connect this equipment to a dimmer pack. Do not switch the equipment on and off in short intervals, as this will reduce the system s life. Only use the equipment indoors. Do not expose to flammable sources, liquids or gases. Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable. Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz. Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically. If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again. WARRANTY: One year from date of purchase. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and/or property. If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not connect power or switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature. If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service. Only use fuses of same type and rating. Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. This lighting fixture is for professional use only - it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls. Warning! Risk Group 2 LED product according to EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam. www.prolight.co.uk Hypnos User Manual 2

Product overview & technical specifications Hypnos The Hypnos is a unique projection effect and is perfect for any function, event or venue. Fitted with different textured glasses it outputs several exciting illusions. When the glasses are mixed with the high output quad-colour LED your venue or event is bathed in colour changing hypnotic effects which can be controlled in several different modes as well as a choice of speed settings from slow mellow changes to fast effects via sound activation. 6 x 15W quad-colour LEDs (RGBW) DMX channels: 10 or 34 selectable Auto, sound active and master/slave modes plus built-in programs 0-100% dimming and variable strobe Optional CA 8 controller Supplied with hanging bracket 4 push button menu with LED display IEC power input/output 3-Pin XLR input/output Fan cooled Specifications Power consumption Power supply Fuse Dimensions Weight Order code 90W 100~240V, 50/60Hz F1A 250V 246 x 246 x 185mm 3.4kg EQLED372 246mm 185mm 246mm www.prolight.co.uk Hypnos User Manual 3

Technical specifications 11 02 MIC 03 MENU UP DOWN ENTER 04 13 12 12 HYPNOS www.prolight.co.uk DMX OUTPUT 06 01 REMOTE CONTROL INPUT 10 05 08 DMX INPUT 07 09 14 SAFETY EYE POWER OUTPUT: 100-240V~50/60Hz POWER CONSUMPTION: 90W POWER INPUT: 100-240V~50/60Hz FUSE: F1A 250V 01 - Earth point 02 - LED display 03 - Function buttons 04 - Microphone 05-3-Pin DMX input 06-3-Pin DMX output 07 - IEC power input 08 - IEC power output 09 - Fuse F1A 250V 10 - CA 8 control input 11 - Hanging bracket 12 - Hanging bracket adjustment knobs 13 - Fan cooling vents 14 - Safety eye In the box: 1 x fixture, 1 x power cable, & 1 x user manual www.prolight.co.uk Hypnos User Manual 4

Operating instructions A d d r C H N d S L N d N A s t d 0 0 1 d 5 1 2 1 0 C H 3 4 C H S L 1 S L 2 O F F O N DMX address setting Channel modes Slave mode Master mode S H N d S H 0 S H 1 3 S P 0 0 S P 9 9 Show modes MENU S O U N O N O F F Sound active S E N S 1 0 0 Sound sensitivity N A S t d N S t L A S t No DMX signal b L N d L E d O N O F F LED backlight d I S P d I S P d S I p Display invert www.prolight.co.uk Hypnos User Manual 5

Operating instructions r E d 2 5 5 g r E E 2 5 5 b L U E 2 5 5 MENU N A N U U H I t d I N N 2 5 5 2 5 5 Manual mode S t r 0 2 5 5 r O t A 2 5 5 P A t t 2 5 5 t E N p F H r s U E r t - - - - - - - U - - - Fixture temperature Fixture hours Software version www.prolight.co.uk Hypnos User Manual 6

Operating instructions DMX mode: Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customising or creating a show. In this mode you will be able to control each individual trait of the fixture and each fixture independently. To access the DMX address mode, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show Addr on the LED display. Now press the ENTER button and use the UP and DOWN buttons to set the required DMX address. Press the ENTER button to confirm the setting. DMX channel mode: To access the DMX channel mode, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show CHNd on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose one of the 10 or 34 DMX channel modes. Press the ENTER button to confirm the setting. 10 channel mode: Channel Value Function CH1 000-255 Red dimmer (0-100%) CH2 000-255 Green dimmer (0-100%) CH3 000-255 Blue dimmer (0-100%) CH4 000-255 White dimmer (0-100%) CH5 000-255 Master dimmer (0-100%) 000-063 No function 064-095 Strobe (slow-fast) 096-127 No function CH6 128-159 Strobe ramp up (slow-fast) 160-191 No function 192-223 Random strobe 224-255 No function 000-003 No function 004-021 Show 0 CH7 022-039 Show 1 040-057 Show 2 058-075 Show 3 076-093 Show 4 Channel Value Function CH7 cont. 094-111 Show 5 112-129 Show 6 130-147 Show 7 148-165 Show 8 166-183 Show 9 184-201 Show 10 202-219 Show 11 220-237 Show 12 238-255 Show 13 CH8 000-255 Show mode motor speed (slow-fast) CH9 CH10 000-127 Rotation index 128-191 Clockwise rotation (fast-slow) 192-255 Anti-clockwise rotation (fast-slow) 000-063 Pattern 1 (water effect) 064-127 Pattern 2 (dot effect) 128-191 Clockwise rotation (fast-slow) 192-255 Anti-clockwise rotation (slow-fast) www.prolight.co.uk Hypnos User Manual 7

Operating instructions 34 channel mode: Channel Value Function CH1 000-255 Red dimmer (0-100%) CH2 000-255 Green dimmer (0-100%) CH3 000-255 Blue dimmer (0-100%) CH4 000-255 White dimmer (0-100%) CH5 000-255 Master dimmer (0-100%) 000-063 No function 064-095 Strobe (slow-fast) 096-127 No function CH6 128-159 Strobe ramp up (slow-fast) 160-191 No function 192-223 Random strobe 224-255 No function CH7 000-127 Red 1 off 128-255 Red 1 on CH8 000-127 Green 1 off 128-255 Green 1 on CH9 000-127 Blue 1 off 128-255 Blue 1 on CH10 000-127 White 1 off 128-255 White 1 on CH11 000-127 Red 2 off 128-255 Red 2 on CH12 000-127 Green 2 off 128-255 Green 2 on CH13 000-127 Blue 2 off 128-255 Blue 2 on CH14 000-127 White 2 off 128-255 White 2 on CH15 000-127 Red 3 off 128-255 Red 3 on CH16 000-127 Green 3 off 128-255 Green 3 on CH17 000-127 Blue 3 off 128-255 Blue 3 on CH18 000-127 White 3 off 128-255 White 3 on CH19 000-127 Red 4 off 128-255 Red 4 on CH20 000-127 Green 4 off 128-255 Green 4 on CH21 000-127 Blue 4 off Channel Value Function CH21 128-255 Blue 4 on CH22 000-127 White 4 off 128-255 White 4 on CH23 000-127 Red 5 off 128-255 Red 5 on CH24 000-127 Green 5 off 128-255 Green 5 on CH25 000-127 Blue 5 off 128-255 Blue 5 on CH26 000-127 White 5 off 128-255 White 5 on CH27 000-127 Red 6 off 128-255 Red 6 on CH28 000-127 Green 6 off 128-255 Green 6 on CH29 000-127 Blue 6 off 128-255 Blue 6 on CH30 000-127 White 6 off 128-255 White 6 on 000-003 No function 004-021 Show 0 022-039 Show 1 040-057 Show 2 058-075 Show 3 076-093 Show 4 094-111 Show 5 CH31 112-129 Show 6 130-147 Show 7 148-165 Show 8 166-183 Show 9 184-201 Show 10 202-219 Show 11 220-237 Show 12 238-255 Show 13 CH32 000-255 Show mode motor speed (slow-fast) 000-127 Rotation index CH33 128-191 Clockwise rotation (fast-slow) 192-255 Anti-clockwise rotation (fast-slow) 000-063 Pattern 1 (water effect) CH34 064-127 Pattern 2 (dot effect) 128-191 Clockwise rotation (fast-slow) 192-255 Anti-clockwise rotation (slow-fast) www.prolight.co.uk Hypnos User Manual 8

Operating instructions Master/slave mode: To set the master unit, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show NASt on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose ON choose OFF. Press the ENTER button to confirm the setting. Then select your desired program. To set the other units in slave mode, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show SLNd on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose either SL 1~ SL 2. Press the ENTER button to confirm the setting. The unit will now run in sequence with the master unit. Please ensure that all slave units are set to the same DMX channel mode as the master unit. Show mode: To access the show modes, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show SHNd on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose between SH 0 ~ SH 13. Now press the ENTER button and use the UP and DOWN buttons to select the speed between SP00 ~ SP99. Press the ENTER button to confirm the setting. Show 0 Runs through all other show modes Show 1 Inwards program, both patterns Show 2 Outwards program, both patterns Show 3 Inwards/outwards program, both patterns Show 4 Inwards/outwards program, pattern 1 Show 5 Inwards/outwards program, pattern 2 Show 6 Inwards/outwards program, both patterns (2 colour segments 3/3) Show 7 Outwards program, both patterns (2 colour segments 5/1) Show 8 Inwards program, both patterns (3 colour segments) Show 9 Inwards/outwards program, both patterns (6 colour segments) Show 10 Inwards/outwards program, both patterns, red only (not reactive to sound) Show 11 Inwards/outwards program, both patterns, green only (not reactive to sound) Show 12 Inwards/outwards program, both patterns, blue only (not reactive to sound) Show 13 Inwards/outwards program, both patterns, white only (not reactive to sound) Sound active: To access the sound active setting, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show SOUN on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose between ON or OfF. Press the ENTER button to confirm the setting. www.prolight.co.uk Hypnos User Manual 9

Operating instructions Sound sensitivity: To adjust the sound sensitivity, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show SENs on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose between 000 ~ 100. Press the ENTER button to confirm the setting. Value: 0-100 (0 = low, 100 = high) DMX signal lost: To change what the unit does when the DMX signal is lost, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show dnst on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose between NASt (Master/Slave), LAst (Hold the last DMX command) or blnd (Blackout). Press the ENTER button to confirm the setting. LED backlight: To access the LED backlight setting, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show LEd on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose between ON or OfF. Press the ENTER button to confirm the setting. Display invert setting: To access the display invert setting, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show disp on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose between disp or dsip. Press the ENTER button to confirm the setting. Manual mode: To access manual mode, press the MENU button on the front of the unit to show NANU on the LED display. Now press the ENTER button and use the UP and DOWN buttons to choose between red (Red), gree (Green), blue (Blue), UHIt (White), dinn (Master dimmer), Str0 (Strobe), rota (Rotation) or Patt (Pattern). Press the ENTER button and use the UP and DOWN buttons to choose between 000 ~ 255. Press the ENTER button to confirm the setting. Fixture temperature: To access the fixtures temperature, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show tenp on the LED display. Now press the ENTER button. The unit will now display the fixtures temperature. www.prolight.co.uk Hypnos User Manual 10

Operating instructions Fixture hours: To access the fixtures usage time, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show FHrS on the LED display. Now press the ENTER button. The unit will now display the fixtures usage time (hours). Software version: To access the fixtures software version, press the MENU button and use the UP and DOWN buttons on the rear of the unit to show VEr on the LED display. Now press the ENTER button. The unit will now display the fixtures software version. CA 8 function: The unit has a CA 8 remote control input on the rear. This may be used with the CA 8 hand controller (sold separately) to control the unit. Please see functions below. Blackout - By pressing the Stand By button the fixture will blackout. Mode - Use this button to put the fixture into auto, show or motor speed modes. Auto mode (Show 0) - LED off Motor speed (1-9) - LED on Show modes (Shows 1-13) - LED flashing Function - Once you have chosen the mode you require use this button to set the motor speed or show mode. Speed (1-9) Show modes (Shows 1-13) www.prolight.co.uk Hypnos User Manual 11

DMX setup Setting the DMX address: The DMX mode enables the use of a universal DMX controller. Each fixture requires a start address from 1-512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the chain starts at 107. DMX 512: DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures (most controllers only have a data out terminal). DMX linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain. DATA cable (DMX cable) requirements (for DMX operation): This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output, see image below. Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers. Please quote: CABL10 2m CABL11 5m CABL12 10m Also remember that DMX cable must be daisy chained and cannot be split. www.prolight.co.uk Hypnos User Manual 12

DMX setup Notice: Be sure to follow the diagrams below when making your own cables. Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing. Grounding the shield could cause a short circuit and erratic behaviour. Special note: Line termination: When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour. Using a cable terminator will decrease the possibilities of erratic behaviour. (3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89) Termination reduces signal transmission problems and interference. it is always advisable to connect a DMX terminal, (resistance 120 Ohm 1/4 W) between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture. 5-pin XLR DMX connectors: Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used. The diagram below details the correct cable conversion. 5-pin XLR (female) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C 3-pin XLR (male) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) 3-pin XLR (female) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) 5-pin XLR (male) Pin 1: GND (screen) Pin 2: Signal (-) Pin 3: Signal (+) Pin 4: N/C Pin 5: N/C www.prolight.co.uk Hypnos User Manual 13

WEEE notice Correct Disposal of this Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. www.prolight.co.uk Hypnos User Manual 14

www.prolight.co.uk Hypnos User Manual 15

www.prolight.co.uk Hypnos User Manual 16