SteelCentral Flow Gateway Appliance Installation Guide. Model SCFG Version x August 2018

Similar documents
SteelCentral Flow Gateway Software Installation Guide. Virtual Edition for VMware ESXi 5.5 and 6.0 Version x June 2017

Cascade Sensor Installation Guide. Version 8.2 March 2009

SteelCentral AppResponse 11 Virtual Edition Installation Guide

SteelCentral AppResponse 11 Virtual Edition Installation Guide

Cascade Express Installation Guide. Version 8.2 March 2009

SteelCentral AppResponse 11 Virtual Edition Installation Guide

SteelCentral AppResponse 11 Installation Guide

SteelCentral Insights for SteelConnect Users Guide

SteelCentral NetProfiler, NetExpress and Flow Gateway Appliance Installation Guide. Models xx60 Version 10.8 January 2015

SteelCentral NetProfiler Software Installation Guide. Virtual Edition for VMware ESXi 5.5 and 6.0 Version 10.9.x January 2017

SteelCentral NetExpress Software Installation Guide. Virtual Edition for VMware ESXi 5.0, 5.1 and 5.5 Version 10.8 January 2015

UPGRADE GUIDE. Riverbed SteelStore. Upgrade Guide. Version 3.1 May 2014

SteelCentral AppResponse 11 Installation Guide

SteelCentral AppResponse 11 Installation Guide

Riverbed Technology, Inc. 199 Fremont Street San Francisco, CA Phone Fax

Riverbed Central Management Console Virtual Edition Installation Guide. Version 8.5 September 2013

Sidewinder. Hardware Guide Models S1104, S2008, S3008. Revision E

SteelCentral Product Family Specifications

Cisco TelePresence Supervisor MSE 8050

SteelConnect Virtual Gateway Installation Guide

Installation and Configuration Guide

Manager Appliance Quick Start Guide

Cisco UCS C-Series IMC Emulator Quick Start Guide. Cisco IMC Emulator 2 Overview 2 Setting up Cisco IMC Emulator 3 Using Cisco IMC Emulator 9

Cascade Profiler, Express, Sensor and Gateway Appliance Installation Guide. Version 10.6 March 2014

Citrix CloudBridge CB User Manual

ForeScout CounterACT. Single CounterACT Appliance. Quick Installation Guide. Version 8.0

Installation and Configuration Guide

McAfee Network Security Platform

Recovery Guide for Cisco Digital Media Suite 5.4 Appliances

Installing and Managing the Switch

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NGFW Security Management Center Appliance. for Forcepoint Next Generation Firewall Hardware Guide. Revision B

Symantec Protection Center Getting Started Guide. Version 2.0

Cisco TelePresence Video Communication Server. Getting started

Codian IP VCR IP VCR 2200 Series

Crestron Mercury Tabletop UC Audio Conference Console for Microsoft Teams

ACE Live on RSP: Installation Instructions

Polycom RealPresence Distributed Media Application (DMA ) System

Quick Install Guide. ibypass TM I2BP-4x Rev A 11/14

Silver Peak EC-V and Microsoft Azure Deployment Guide

SteelCentral Controller for SteelHead (Virtual Edition) Installation Guide. Version 9.0 December 2014

UDP Director Virtual Edition Installation and Configuration Guide (for Stealthwatch System v6.9.0)

Oracle Enterprise Manager Ops Center. Overview. What You Need. Create Oracle Solaris 10 Zones 12c Release 3 ( )

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

Deploy the ExtraHop Trace 6150 Appliance

Cascade Installation Guide Version 9.0 February 2011

Oracle Enterprise Manager Ops Center. Introduction. Provisioning Oracle Solaris 10 Operating Systems 12c Release 2 ( )

EdgeConnect for Amazon Web Services (AWS)

SteelCentral Product Family Specifications

Configure the Cisco DNA Center Appliance

Deploy the ExtraHop Discover 3100, 6100, 8100, or 9100 Appliances

Nokia Intrusion Prevention with Sourcefire. Appliance Quick Setup Guide

Deploy the ExtraHop Discover Appliance 1100

Remote Console Manager with GSM Modem QS Guide

Deploy the ExtraHop Trace 6150 Appliance

Cisco TelePresence Video Communication Server. Getting started

Installation. Power on and initial setup. Before You Begin. Procedure

SonicWall SonicOS 5.9

Pexip Infinity and Amazon Web Services Deployment Guide

Moxa Remote Connect Server Software User s Manual

Link Gateway Initial Configuration Manual

STEELCENTRAL PRODUCT FAMILY SPECIFICATIONS

Fidelis Enterprise Collector Cluster QUICK START GUIDE. Rev-H Collector Controller2 (HP DL360-G9) and Collector XA2 (HP DL360-G9) Platforms

Deploy the ExtraHop Discover EDA 6100, EDA 8100, or EDA 9100 Appliances

On-Premise SteelConnect Manager Setup Guide

Moxa Remote Connect Gateway User s Manual

Reinstalling the Operating System on the Dell PowerVault 745N

Deploying Devices. Cisco Prime Infrastructure 3.1. Job Aid

Dell SonicWALL SonicOS 5.9 Upgrade Guide

Overview of the Plug-In. Versions Supported. Deploying the Plug-In

Configure the Cisco DNA Center Appliance

Cisco TelePresence VCS CE1000 Appliance

Oracle Enterprise Manager Ops Center. Introduction. What You Will Need

UDP Director Virtual Edition

Riverbed Central Management Console Installation Guide. Version 7.0 August 2012

CM500 High Speed Cable Modem User Manual

DX 32xx and DX 36xx Quick Start

Forescout. Quick Installation Guide. Single Appliance. Version 8.1

CounterACT 7.0 Single CounterACT Appliance

F5 WANJet 200. Quick Start Guide. Quick Start Overview

VTRAK E-Class/J-Class Quick Start Guide

Cisco Business Edition 6000 Installation Guide, Release 10.0(1)

Oracle Enterprise Manager Ops Center

SonicWall Secure Mobile Access SMA 500v Virtual Appliance 8.6. Getting Started Guide

Intel Small Business Extended Access. Deployment Guide

SteelConnect Access Point Hardware Guide. June 2016

HP integrated Citrix XenServer Online Help

Videoscape Distribution Suite Software Installation Guide

SafeConsole On-Prem Install Guide

Riverbed Central Management Console Installation Guide. Version 8.6.0c October 2014

FortiTester Handbook VERSION FortiTester Handbook Fortinet Technologies Inc.

NetApp Cloud Volumes Service for AWS

ECDS MDE 100XVB Installation Guide on ISR G2 UCS-E and VMWare vsphere Hypervisor (ESXi)

Netwrix Auditor. Virtual Appliance and Cloud Deployment Guide. Version: /25/2017

Stealthwatch Flow Sensor Virtual Edition Installation and Configuration Guide (for Stealthwatch System v6.9.0)

Juniper Secure Analytics Quick Start Guide

Manual Version: V1.00. Video Decoder User Manual

Initial Configuration for the Switch

User Manual A08. User Manual

Quick Start Guide. Remote Console Manager Quick Start Guide

Transcription:

SteelCentral Flow Gateway Appliance Installation Guide Model SCFG-02270 Version 10.14.x August 2018

2018 Riverbed Technology, Inc. All rights reserved. Riverbed, SteelConnect, SteelCentral, SteelHead, and SteelFusion are all trademarks or registered trademarks of Riverbed Technology, Inc. (Riverbed) in the United States and other countries. Riverbed and any Riverbed product or service name or logo used herein are trademarks of Riverbed. All other trademarks used herein belong to their respective owners. The trademarks and logos displayed herein cannot be used without the prior written consent of Riverbed or their respective owners. This document is furnished "AS IS" and is subject to change without notice and should not be construed as a commitment by Riverbed. Riverbed does not provide any warranties for any information contained herein and specifically disclaims any liability for damages, including without limitation direct, indirect, consequential, and special damages in connection with this document. This document may not be copied, modified or distributed without the express authorization of Riverbed and may be used only in connection with Riverbed products and services. Use, duplication, reproduction, release, modification, disclosure or transfer of this document is restricted in accordance with the Federal Acquisition Regulations as applied to civilian agencies and the Defense Federal Acquisition Regulation Supplement as applied to military agencies. This document qualifies as "commercial computer software documentation" and any use by the government shall be governed solely by these terms. All other use is prohibited. Riverbed assumes no responsibility or liability for any errors or inaccuracies that may appear herein. Individual license agreements can be viewed at the following location: https://<appliance_name>/license.php This manual is for informational purposes only. Addresses shown in screen captures were generated by simulation software and are for illustrative purposes only. They are not intended to represent any real traffic or any registered IP or MAC addresses. Riverbed Technology 680 Folsom Street San Francisco, CA 94107 Phone: 415.247.8800 Fax: 415.247.8801 Web: http://www.riverbed.com Part Number 712-00268-09

Contents Chapter 1 - Introduction...1 Additional Resources...1 Safety Guidelines...2 Contacting Riverbed...2 Chapter 2 - Preparation...3 Requirements...3 Data sources...4 Cable connections...4 Power...4 Console port...4 Primary port...4 Auxiliary port...5 Access to the network...5 Configuration information...5 Licensing strategy...7 Downloading and adding license keys...8 Chapter 3 - Cabling...9 Cabling to the console port...9 Cabling to the management network...10 Primary port...10 Auxiliary port...10 Power cabling...10 Chapter 4 - Configuration... 11 Installation time considerations...11 Step 1 - Run the configuration wizard...11 Step 2 - Log in to the web user interface...12 SteelCentral Flow Gateway Appliance Installation Guide iii

Contents Chapter 5 - Installing new software...15 Overview...15 Checklist...16 Step 1 - Download the software...17 Step 2 - Create bootable USB memory sticks...17 Step 3 - Insert the bootable USB memory stick into the system...17 Step 4 - Connect to the console port...17 Step 5 - Configure the BIOS...17 Step 6 - Install the software...18 Step 7 - Remove the USB memory stick...18 Step 8 - Run the configuration wizard...18 Step 9 - Log into the web user interface...19 Chapter 6 - Licensing...21 Automatic licensing...21 Manual licensing...22 Licensing multiple products...23 Next steps...24 Chapter 7 - Installation verification...25 Chapter 8 - Cloud flow data sources...27 SteelCentral AppResponse Cloud...27 SteelCentral Agent...27 Amazon Web Services VPC network...27 Appendix A - Specifications...29 Console cable wiring...29 Controls and indicators...30 Front panel...30 Disk fault indicators...31 Mechanical and electrical specifications...31 iv SteelCentral Flow Gateway Appliance Installation Guide

CHAPTER 1 Introduction This guide describes installing the Riverbed SteelCentral Flow Gateway. It assumes that the product has already been mounted in the rack as described for SteelCentral model xx70 series products in the Rack Installation Guide. It describes preparations, cabling the product, configuring it on your network, activating the licenses, and verifying that the appliance is receiving and processing traffic data. When these tasks are completed, Flow Gateway is ready to configure operationally. Operational configuration is described in the online help system of each product. This guide also describes downloading new software from the Riverbed Support site and installing it, in case you choose to do that instead of running the factory-installed software. Command Line Interface access to Flow Gateway is supported for only initial setup and maintenance purposes. Installing additional software or modifying configurations via the command line interface are not supported and may cause unexpected behavior or stability issues. This guide includes: Chapter 1, Introduction Chapter 2, Preparation Chapter 3, Cabling Chapter 4, Configuration Chapter 5, Installing new software Chapter 6, Licensing Chapter 7, Installation verification Appendix A, Specifications. Additional Resources The primary source of product information is the online help system. Additional information is available from the Riverbed Support site at https://support.riverbed.com. This includes: Release Notes - posted in the software section of the page for your product. Users Guides - posted in the documentation section of the page for your product. Knowledge Base - a database of known issues and how-to documents. You can browse titles or search for key words and strings. Choose Search the Knowledge Base from the Knowledge Base menu. SteelCentral Flow Gateway Appliance Installation Guide 1

Introduction Safety Guidelines Safety Guidelines Follow the safety precautions outlined in the Safety and Compliance Guide when installing and setting up your equipment. Important: Failure to follow these safety guidelines can result in injury or damage to the equipment. Mishandling of the equipment voids all warranties. Please read and follow safety guidelines and installation instructions carefully. Many countries require the safety information to be presented in their national languages. If this requirement applies to your country, consult the Safety and Compliance Guide. Before you install, operate, or service the Riverbed product, you must be familiar with the safety information. Refer to the Safety and Compliance Guide if you do not clearly understand the safety information provided in this guide. Contacting Riverbed Options for contacting Riverbed include: Internet - Find out about Riverbed products at http://www.riverbed.com. Support - If you have problems installing, using, or replacing Riverbed products, contact Riverbed Technical Support or your channel partner who provides support. To contact Riverbed Technical Support, please open a trouble ticket at https://support.riverbed.com or call 1-888-RVBD-TAC (1-888-782-3822) in the United States and Canada or +1 415 247 7381 outside the United States. Professional Services - Riverbed has a staff of engineers who can help you with installation, provisioning, network redesign, project management, custom designs, consolidation project design, and custom-coded solutions. To contact Riverbed Professional Services, go to http://www.riverbed.com or email proserve@riverbed.com. Documentation - Riverbed continually strives to improve the quality and usability of its documentation. We appreciate any suggestions you may have about our online documentation or printed materials. Send documentation comments to techpubs@riverbed.com. 2 SteelCentral Flow Gateway Appliance Installation Guide

CHAPTER 2 Preparation This chapter describes equipment, network access, and configuration information that is necessary for installing Flow Gateway. The topics include: Requirements on page 3 Data sources on page 4 Cable connections on page 4 Configuration information on page 5 Licensing strategy on page 7 Requirements Data sources Cable for connection to management network Access to the management network Terminal emulator set to 9600 baud, 8 data bits, 1 stop bit, no parity and no flow-control Console cable provided in the accessory kit shipped with the chassis. This cable has a 9-pin D-subminiature connector on one end and an RJ45 connector on the other end for connecting to the console port. The cable wiring is listed in Appendix A, Specifications. Configuration information for placing Flow Gateway on your network Customer account on the Riverbed Support site Licensing strategy If you will be downloading new software from the Riverbed Support site instead of running the factory-installed software, you will also need: USB memory sticks with at least 1 GB capacity Universal USB installer utility SteelCentral Flow Gateway Appliance Installation Guide 3

Preparation Data sources Data sources Flow Gateway obtains traffic information from NetFlow, IPFIX, sflow or compatible Packeteer FDR sources. It also receives SteelFlow Net information from SteelHead (formerly called CascadeFlow). This includes application identification, QoS configuration and flow data. SteelFlow Net is a standards-compliant variant of NetFlow v9 that uses a custom Riverbed template to send standard NetFlow data as well as more specialized metrics. If Flow Gateway is to receive flow data from NetFlow-enabled devices, enable the SNMP ifindex persistence feature of the NetFlow source to ensure consistency of interface reporting. Additionally, Riverbed SteelCentral Agent and Amazon Web Services Virtual Private Cloud networks can be configured to send cloud flow data to Flow Gateway. There are two approaches to setting up data sources: Set up the available data sources and point them to the IP address of Flow Gateway before you install it. Install Flow Gateway up to the point of verification, then install or configure the data sources, and then return to Flow Gateway to complete the installation verification. It is preferable to configure all the data sources that are available at the time you install Flow Gateway. However, product operation can be confirmed with just one data source. Cable connections Ensure that cables for the following connections are available at the location where the product is installed. Power Flow Gateway has two power supplies. It is recommended that these be plugged into two different circuits, if they are available. Console port The initial setup is performed using the console port. Ensure that you have a terminal server or a system running a terminal emulation program and a cable for connecting to the console port, such as the cable supplied in the accessory kit shipped with the chassis. This cable has a 9-pin D-subminiature connector on one end and an RJ45 connector on the other end for connecting to the console port. The cable wiring is listed in Appendix A, Specifications. Primary port Flow Gateway is equipped with a 100/1000baseTX primary management port that must connect to a hub or switch on the management network. The primary port is set by default for auto-negotiation. Ensure that: The management network has a switch port for Flow Gateway. A straight-through cable is available at the rack location for connecting Flow Gateway to the switch. The management network switch port is set to establish a connection at 1000 Mb/s and full duplex. 4 SteelCentral Flow Gateway Appliance Installation Guide

Configuration information Preparation A terminal device (laptop, KVM, etc.) is available on the management network for logging in to the Flow Gateway user interface. Auxiliary port Optionally, the AUX port can be configured. This is useful if you what to keep network data and network control traffic on separate networks. Additionally, the AUX port can be configured for access to the remote management features for performing chassis-level functions. Ensure that: A straight-through cable to a hub or switch port on the network is available at the rack location. The network switch port is set to establish a connection at 100 or 1000 Mb/s and full duplex. Access to the network Flow Gateway uses the management network to access network services to provide access to its user interface. Communication between SteelCentral products If you lock down your network on a port-by-port basis, ensure that the following ports are open between SteelCentral products: TCP/22 (ssh) Flow Gateway uses this port to download and synchronize update packages from the SteelCentral Standard or Enterprise NetProfiler to which it is connected. TCP/443 Packet Analyzer communicates with the web interface of the NetShark over this port. TCP/8443 Exchange of encryption certificates between SteelCentral products. TCP/41017 Encrypted communication between Flow Gateway and NetProfiler or NetExpress appliances. UDP/123 (ntp) Synchronization of time between Flow Gateway and Flow Gateway. Access to and from network access services TCP/22 (ssh) This is needed for secure shell access to SteelCentral software components and for the appliance to obtain information from servers via scripts. TCP/443 (https) Secure web-based management interfaces. Configuration information When you configure Flow Gateway, you will be asked to provide configuration information. Information that is required to complete the installation is listed in the table that follows with an asterisk (*). Items not marked with an asterisk are optional during installation and can be specified afterwards on the Flow Gateway Configuration > General Settings page if necessary. It may be useful to write the configuration values in the blank column of the checklist below so that you can refer to them during the configuration step or afterward. Flow Gateway host name:* Flow Gateway IP address:* Netmask:* SteelCentral Flow Gateway Appliance Installation Guide 5

Preparation Configuration information Default gateway:* DNS name resolution for hosts (enable or disable): Primary DNS server IP address: Secondary DNS server IP address: DNS search domain: Management (Primary) port settings: (10/100/1000 Mb/s, half- or full-duplex, or auto-negotiate) Switch port settings: The settings of the switch port or hub that the NetProfiler primary port connects to. (Auto-negotiate is recommended.) Aux interface IP address Aux interface netmask Aux interface switch port settings Time Zone: Flow encryption certificate (default or new certificate): For faster installation, use the default encryption certificate shipped with Flow Gateway and then generate a new certificate later. NetFlow port: Applies only if NetExpress is receiving NetFlow data (versions 1, 5, 7 or 9), IPFIX data, or SteelFlow Net data. Do not send more than one type of flow data to the same port. sflow port: Applies only if NetExpress is receiving sflow data (versions 2, 4 or 5). Do not send more than one type of flow data to the same port. Packeteer port: Applies only if NetExpress is receiving Packeteer Flow Detail Records (versions 1 or 2). Do not send more than one type of flow data to the same port. SNMP information: Flow Gateway is set by default to use SNMP Version 1 and to allow MIB browsing. If you are configuring SNMP at this time, obtain the necessary V1 or V3 information. First NetProfiler data input address. The address of the NetProfiler to which the Flow Gateway will send traffic data. This is the IP address of the management interface (Primary port) of an NetExpress or Standard NetProfiler or the address of the first Analysis Module of an Enterprise NetProfiler. If data sent to this NetProfiler is to be limited to only data received from certain flow sources, then specify those sources. NetProfiler IP Address: Flow sources: 6 SteelCentral Flow Gateway Appliance Installation Guide

Licensing strategy Preparation Second NetProfiler data input address. If the Flow Gateway will be sending traffic data to more than one NetProfiler, this is the IP address of the second NetProfiler. It is the management interface (Primary port) of an NetExpress or Standard NetProfiler or the address of the Analysis Module of an Enterprise NetProfiler. If flow forwarding to this NetProfiler is to be limited to only data received from certain flow sources, then specify those sources Data Forward - Destination 1 IP address and port number of the first destination to which the Flow Gateway is to forward flow data, the type of data (e.g., NetFlow) to be forwarded, and whether or not the source address of the forwarded packets should be overwritten with the source address from which they were received. If flow forwarding to this destination is to be limited to data received from only certain flow sources, then specify those sources. Data Forward - Destination 2 IP address and port number of the second destination to which the Flow Gateway is to forward flow data, the type of data (e.g., NetFlow) to be forwarded, and whether or not the source address of the forwarded packets should be overwritten with the source address from which they were received. If flow forwarding to this destination is to be limited to data received from only certain flow sources, then specify those sources. NetProfiler IP Address: Flow sources: IP address: Port: Type: Source: Overwrite source address? Yes/No: IP address: Port: Type: Source: Overwrite source address? Yes/No: Password to use for your initial Flow Gateway login:* The default password admin. New password to enter when prompted to change the initial Flow Gateway password:* Applies only to systems not previously configured. Licensing strategy Capacity and feature licenses must be activated on the Riverbed Support site. SteelCentral products that have been configured and have access to Internet automatically download the license keys that have been assigned to their serial numbers in the Licenses section of the Support site. If the appliance does not have Internet access, then you must add its license keys manually. The Riverbed Support site licensing pages provide the flexibility to assign different feature and capacity licenses to different appliances. You can ship appliances to remote locations without concern for which appliance is to have which license. When you have the serial numbers and know where the appliances are deployed in the network, you can make the license assignments on the Support site. When all the appliances are to be licensed for the same features and capacities, the Support site handles this automatically. The appliances can automatically download their licenses without your needing to visit the Support site. SteelCentral Flow Gateway Appliance Installation Guide 7

Preparation Licensing strategy Downloading and adding license keys If Flow Gateway is configured and has Internet connectivity, it can download its license keys automatically. Otherwise, someone must email the keys from the Licenses section of the Riverbed Support site and then copy them from the email, or else copy them directly from the Support site, and then someone must add them to Flow Gateway manually. Determine which strategy you are using. Will you activate the licenses on the Riverbed Support site yourself? Or will someone else do that? If the Flow Gateway you are installing does not have Internet access, how will you ensure that it gets its assigned license keys? Will you email them to yourself from the Riverbed Support site? Will you copy them from the Support site? Or will someone else provide the license keys for you to add to the Flow Gateway manually? Typically the installer: 1. Mounts, cables and configures this appliance and the other SteelCentral products that were ordered with it. 2. Records the product serial number from the chassis of each appliance. The number identified as SN is the product serial number for the chassis. It is located on the pull-out tab near the upper-left corner of the front of the chassis. 3. Sends the serial number for each appliance, along with the appliance location on the network, to the network manager. Then the network manager: 1. Logs in to the Riverbed Support site and goes to the Licenses section. 2. Enters the product serial number of the first SteelCentral product to gain access to the licensing page. The Riverbed licensing page lists the serial numbers of all SteelCentral products that were included in the same purchase order. 3. For each serial number, activates the licenses that apply to that serial number. Using the Licenses section of the Riverbed Support site is described in Chapter 6, Licensing. After the licenses have been activated on the Riverbed Support site, the license keys can be added to the Flow Gateway either automatically or manually. If only one appliance is being installed, or if all the appliances are to be licensed for the same features and capacities, the Support site handles this automatically. The appliances can automatically download their licenses without your needing to visit the Support site. Licensing is described in Chapter 6, Licensing. 8 SteelCentral Flow Gateway Appliance Installation Guide

CHAPTER 3 Cabling Installation requires connecting to the console port for initial software configuration and connecting to the primary port for operations. Cabling to the console port on page 9 Cabling to the management network on page 10 Power cabling on page 10 Cabling to the console port If there is to be a permanent connection from the console port to a terminal server, make the connections now. Refer to Appendix A, Specifications for console port pin assignments. If you will temporarily connect to the console for configuring the software, ensure that you have: Laptop or other device running a terminal emulation program. Set the device s terminal emulator to 9600 Baud, 8 data bits, 1 stop bit, no parity bit, and no flow control. A cable for connecting to the console port, such as the cable supplied in the accessory kit shipped with the chassis. This cable has a 9-pin D-subminiature connector on one end and an RJ45 connector on the other end for connecting to the console port. The cable wiring is listed in Appendix A, Specifications. Connect the cable to the console connector on the back of the chassis. SteelCentral Flow Gateway Appliance Installation Guide 9

Cabling Cabling to the management network Cabling to the management network Primary port Connect a straight-through cable from the management network to the Primary (PRI) connector on back of the Flow Gateway chassis. Auxiliary port If the Auxiliary port is to be used for receiving data or for remote management of chassis-level functions, connect a straight-through cable from the management network to the to the AUX connector. The Auxiliary port does not need to be on the same network as the Primary port. When the remote management feature is used, the network address and login credentials for remote access to the BMC (baseboard management controller) web user interface are usually configured by a system administrator as part of the operational configuration after Flow Gateway has been installed. For additional information, complete the installation and then consult the online help for the Configuration > General Settings page of the web user interface. Power cabling If the power cables were not installed when the chassis were mounted in the racks, install them at this time. If possible, plug the two power supplies into two different power sources. The chassis is configured to initialize when power is connected. 10 SteelCentral Flow Gateway Appliance Installation Guide

CHAPTER 4 Configuration The Flow Gateway is shipped from the factory with its software already installed. This chapter describes configuring the factory-installed software. If instead you want to install and configure new software downloaded from the Riverbed Support site, refer to Chapter 5, Installing new software. This chapter includes: Installation time considerations on page 11 Step 1 - Run the configuration wizard on page 11 Step 2 - Log in to the web user interface on page 12 Installation time considerations The time required for installing the Flow Gateway is shortest if you configure and run the factory-installed software. If you will be running a version of the software later than the version that was installed at the factory, then there are two approaches to installing that version: Configure the factory-installed software as described in this chapter and then update it to the latest version. Perform a full installation of new software downloaded from the Riverbed Support site. This replaces the factoryinstalled software. If the software version on the Support site is only one or two versions later than the factory-installed version, it may be faster to configure the factory-installed software and then update it to the latest version. If the software on the Support site is several versions later than the factory-installed version, it may be faster to download the latest version from the Support site and perform a full installation. This is described in Chapter 5, Installing new software. To configure and run the factory-installed software, follow the steps below. Step 1 - Run the configuration wizard 1. On the system that has the cable connected to the Flow Gateway console connector, use your terminal emulator to log in through the console port. The default login credentials are: User name: admin Password: admin SteelCentral Flow Gateway Appliance Installation Guide 11

Configuration Step 2 - Log in to the web user interface 2. When the configuration wizard starts, it displays the product model and serial number. If you will be activating the licenses manually, record this information to use during license activation. 3. Enter the required information at the prompts. Use your keyboard s Up Arrow to choose an IPv4 address or an IPv6 network to pre-populate the Management address field. For IPv6, add the host address before the prefix length. A typical configuration dialog proceeds as follows: Welcome to SteelCentral Setup! Configuring SCFG-02270 with serial number 0000000000000 Press up arrow to access these addresses or ctrl+c to restart Discovered IPv4 address 10.38.136.55/18 Discovered IPv6 network 2600:809:200:1a02:/64 Please enter the MGMT IP ADDRESS ip/prefixlen: 2600:809:200:1a02:100:0:a26:8837/64 Please enter the GATEWAY IP ADDRESS ip: 2600:809:200:1a02::1 Please enter the password for the mazu, dhcp, root, and admin shell users: ******** Please re-enter the password: ******** New Settings: Product: IP Address: Gateway: SCFG-02270 2600:809:200:1a02:100:0:a26:8837/64 2600:809:200:1a02::1 NOTE: Setup will conclude with a reboot of this SteelCentral device. After all modules have rebooted, setup can be completed by logging into the UI at https://[2600:809:200:1a02:100:0:a26:8837]/ Login as admin/admin. NOTICE: All existing settings and logs will be lost. Finish Setup and Reboot? (yes/no): yes Working... 4. When the wizard completes and exits, the system reboots. Wait until the system finishes rebooting before continuing with the next step. Step 2 - Log in to the web user interface 1. Using a system that is connected to the management network, point your web browser to the IP address you specified in the configuration wizard in the previous step. https://<flow_gateway_ip_address> 2. Log in to the Flow Gateway user interface. The default credentials are: User name: admin Password: admin The first time you log in to the Flow Gateway user interface, it displays the Setup page. 3. On the Setup page, ensure that all the required fields (marked with an asterisk) are filled in. 12 SteelCentral Flow Gateway Appliance Installation Guide

Step 2 - Log in to the web user interface Configuration 4. At the bottom of the Setup page, click Configure Now. 5. When prompted, enter a new password for the web user interface. If Flow Gateway has an Internet connection, it will attempt to download licenses from the Riverbed Support site. Alternatively, you can either add or download applicable licenses using the Flow Gateway Configuration > Licenses page. Refer to Chapter 6, Licensing. SteelCentral Flow Gateway Appliance Installation Guide 13

Configuration Step 2 - Log in to the web user interface 14 SteelCentral Flow Gateway Appliance Installation Guide

CHAPTER 5 Installing new software This chapter describes how to download the software from the Riverbed Support site and install it in Flow Gateway. It provides a checklist section that can be used as a guide for those familiar with installing software from a USB memory stick, and more detailed step-by-step instructions explaining items on the checklist. Overview on page 15 Checklist on page 16 Step 1 - Download the software on page 17 Step 2 - Create bootable USB memory sticks on page 17 Step 3 - Insert the bootable USB memory stick into the system on page 17 Step 4 - Connect to the console port on page 17 Step 5 - Configure the BIOS on page 17 Step 6 - Install the software on page 18 Step 7 - Remove the USB memory stick on page 18 Step 8 - Run the configuration wizard on page 18 Step 9 - Log into the web user interface on page 19 Overview Flow Gateway is shipped from the factory with its software already installed. You can configure the factory-installed software and begin using the product, or you can perform a complete installation of software downloaded from the Riverbed Support site. To configure and run the factory-installed software, refer to Chapter 4, Configuration. To download a new copy of the software from the Riverbed Support site, follow the instructions in this chapter. SteelCentral Flow Gateway Appliance Installation Guide 15

Installing new software Checklist Checklist Briefly, the installation procedure involves the following tasks: 1. Download the software installation image file from the Riverbed Support site. 2. Create a bootable (live) USB memory stick. 3. Plug the bootable USB memory stick into a USB connector on the front of the chassis. 4. Use a terminal emulator and the cable supplied in the accessory kit to connect to the console port connector on the back of the chassis. 5. Switch on or power-cycle the Flow Gateway. During the power-on self-test (POST) sequence, configure the BIOS to boot from an external USB device. The power switch is in the upper right corner of the front of the chassis. 6. When the system boots from your USB stick and displays the boot prompt, enter install and wait for the system to install the software. This requires approximately 20 minutes. After the installation process completes, the localhost.localdomain login prompt is displayed. 7. When the software installation has completed and the boot prompt is displayed, remove the USB memory stick and power-cycle the appliance. After the system reboots, the login prompt is displayed. 8. Run the configuration wizard. To start the wizard, log in using admin for your user name and admin for your password. Enter the required information when prompted by the configuration wizard. The system reboots when you exit from the configuration wizard. Wait for it to finish rebooting before continuing to the next step. 9. Log into the web user interface from a management system on the network. 10. The first time you log in, the initial Setup page is displayed. Enter the required information in all the fields marked with an asterisk (*). 11. At the bottom of the Setup page, click Configure Now to complete the configuration. 12. When prompted, enter a new password for the web user interface. If the Flow Gateway has an Internet connection, it will attempt to download licenses from the Riverbed Support site. Alternatively, you can either add or download applicable licenses using the Flow Gateway Configuration > Licenses page. Refer to Chapter 6, Licensing. With no external USB memory stick installed, the product will boot off its internal disks if it loses power or is powercycled. However, it may be preferable to reconfigure the BIOS to exclude external USB sticks from the boot order. The sections that follow describe the installation process in greater detail. 16 SteelCentral Flow Gateway Appliance Installation Guide

Step 1 - Download the software Installing new software Step 1 - Download the software Download the installation software from the Riverbed Support site: https://support.riverbed.com This requires an account on the Support site. If you do not have an account, follow the directions on the Support site to set one up. The Support site provides both.usb and.iso versions of the installation file. Step 2 - Create bootable USB memory sticks Flow Gateway software can be loaded on to a USB memory stick using standard procedures. For example, on a Linux system you can create a bootable (live) USB stick from the downloaded.usb file by mounting the USB stick and entering: sudo dd if=/<path_to_download_location> of=/dev/usb bs=1m Or you can use a universal USB installer tool to transfer the.iso file to a USB memory stick in a Microsoft Windows environment. Step 3 - Insert the bootable USB memory stick into the system USB connectors are located on the front and back of the chassis. Insert the memory stick into any USB connector. Step 4 - Connect to the console port If you have not already connected to the console port as part of cabling, 1. Connect a laptop or other device to the console connector using the RJ45 to 9-pin D-subminiature cable supplied in the accessory kit and any necessary connector converter. The cable wiring is listed in Appendix A, Specifications. 2. Set the device s terminal emulator to 9600 Baud, 8 data bits, 1 stop bit, no parity bit, and no flow control. Step 5 - Configure the BIOS The default BIOS configuration causes the product to boot the factory-installed software from an internal disk. To boot from an external USB memory stick, you must change the BIOS configuration as follows: 1. Use the power switch to power-cycle the system. The power switch is in the upper right corner of the front of the chassis. 2. During the POST (power-on self-test) sequence, press F2 to start the BIOS configuration tool. SteelCentral Flow Gateway Appliance Installation Guide 17

Installing new software Step 6 - Install the software 3. On the Advanced menu: Select USB Configuration and press Enter. Select Make USB Devices Non-bootable and press Enter. Select Disabled and press Enter. Press Esc to go back to the previous menu. 4. From the EXIT menu, select Save Changes and Exit and press Enter. 5. Select OK in the resulting screen to save the changes and exit the BIOS configuration tool. Step 6 - Install the software When the system finishes booting from your USB memory stick, enter install at the prompt. Software installation requires approximately 20 minutes. After the installation process completes, the USB memory stick can be removed. If it is not removed, the system boots from the USB and presents the boot prompt again. Step 7 - Remove the USB memory stick When the software installation has completed and the boot prompt is displayed, remove the USB memory stick and power-cycle the appliance. After the system reboots, the login prompt is displayed. Step 8 - Run the configuration wizard 1. On the system that has the cable connected to the Flow Gateway console connector, use your terminal emulator to log in through the console port. The default login credentials are: User name: admin Password: admin 2. When the configuration wizard starts, it displays the product model and serial number. If you will be activating the licenses manually, record this information to use during license activation. 3. Enter the required information at the prompts. Use your keyboard s Up Arrow to choose an IPv4 address or an IPv6 network to pre-populate the Management address field. For IPv6, add the host address before the prefix length. A typical configuration dialog proceeds as follows: Welcome to SteelCentral Setup! Configuring SCFG-02270 with serial number 0000000000000 Press up arrow to access these addresses or ctrl+c to restart Discovered IPv4 address 10.38.136.55/18 Discovered IPv6 network 2600:809:200:1a02:/64 18 SteelCentral Flow Gateway Appliance Installation Guide

Step 9 - Log into the web user interface Installing new software Please enter the MGMT IP ADDRESS ip/prefixlen: 2600:809:200:1a02:100:0:a26:8837/64 Please enter the GATEWAY IP ADDRESS ip: 2600:809:200:1a02::1 Please enter the password for the mazu, dhcp, root, and admin shell users: ******** Please re-enter the password: ******** New Settings: Product: IP Address: Gateway: SCFG-02270 2600:809:200:1a02:100:0:a26:8837/64 2600:809:200:1a02::1 NOTE: Setup will conclude with a reboot of this SteelCentral device. After all modules have rebooted, setup can be completed by logging into the UI at https://[2600:809:200:1a02:100:0:a26:8837]/ Login as admin/admin. NOTICE: All existing settings and logs will be lost. Finish Setup and Reboot? (yes/no): yes Working... 4. When the wizard completes and exits, the system reboots. Wait until the system finishes rebooting before continuing with the next step. Step 9 - Log into the web user interface 1. Using a system that is connected to the management network, point your web browser to the IP address you specified in the configuration wizard in the previous step. https://<flow_gateway_ip_address> 2. Log in to the Flow Gateway user interface. The default credentials are: User name: admin Password: admin The first time you log in to the Flow Gateway user interface, it displays the Setup page. 3. On the Setup page, ensure that all the required fields (marked with an asterisk) are filled in. 4. At the bottom of the Setup page, click Configure Now. 5. When prompted, enter a new password for the web user interface. If Flow Gateway has an Internet connection, it will attempt to download licenses from the Riverbed Support site. Alternatively, you can either add or download applicable licenses using the Flow Gateway Configuration > Licenses page. Refer to Chapter 6, Licensing. SteelCentral Flow Gateway Appliance Installation Guide 19

Installing new software Step 9 - Log into the web user interface 20 SteelCentral Flow Gateway Appliance Installation Guide

CHAPTER 6 Licensing After Flow Gateway has been installed and configured to be reachable on the management network, the licenses must be set up. This chapter describes: Automatic licensing on page 21 Manual licensing on page 22 Licensing multiple products on page 23 Next steps on page 24 Automatic licensing Licensing can be performed automatically if Flow Gateway has Internet access and: You are licensing only one Flow Gateway, or You are licensing multiple Flow Gateway appliances that all have the same features and capacities. If you are licensing multiple Flow Gateway appliances to run with different features or capacities, then it is necessary to go to the Licenses section of the Riverbed Support site and assign the licenses to the serial numbers of the products. See Licensing multiple products on page 23. To license a single Flow Gateway that has Internet access, it is not necessary to go to the Support site. Instead, just confirm that the licenses are active as follows: 1. Log in to the Flow Gateway web user interface admin account. 2. Go to the Configuration > Licenses page and check the License Key column. If the License Key column lists an MSPEC license key, then Flow Gateway has downloaded its licenses from the Support site and you can proceed with installation verification. See Chapter 7, Installation verification. If no MSPEC license key is listed, then Flow Gateway has not downloaded its license keys. 3. If the license keys have not been downloaded, click Fetch Updates Now. The license keys will be listed within a few minutes. SteelCentral Flow Gateway Appliance Installation Guide 21

Licensing Manual licensing 4. Confirm that the licenses are listed on the Configuration > Licenses page and that the status of each is green. If you select the Enable automatic license download from Riverbed option on the Configuration > Licenses page, the appliance checks for any additional licenses once per day. When the license key for flow capacity is listed, the product is ready for operation and you can proceed with installation verification. See Chapter 7, Installation verification. Manual licensing If Flow Gateway does not have access to the Internet, then it is necessary to add the license keys manually, as follows: 1. Obtain the serial number for the appliance to be licensed. It is located on the pull-out tab near the upper-left corner of the front of the chassis. 2. Go to the Riverbed Support site at support.riverbed.com and click the Licenses link. 3. Enter the product serial number. This displays a table listing the serial numbers of all the SteelCentral products purchased on the same purchase order as the appliance whose serial numbers you entered. 4. Follow the instructions of the licensing wizard to generate the license keys. 5. Either choose the option to email the license keys to yourself, or else copy the keys from the Activated License Key column of the table. 6. Place the keys in a file that is accessible to the machine you are using for configuring Flow Gateway. 7. Log in to the Flow Gateway web user interface admin account. 8. On the Flow Gateway, navigate to the Configuration > Licenses page and click Add License(s). 9. Paste or type the license keys into the Licenses page. When entering more than one license key, use a commaseparated list. 22 SteelCentral Flow Gateway Appliance Installation Guide

Licensing multiple products Licensing 10. Confirm that the licenses are listed on the Configuration > Licenses page and that the status of each is green. When the license keys have been added, Flow Gateway is ready for installation verification. See Chapter 7, Installation verification. Licensing multiple products If you are licensing multiple Flow Gateway appliances with different features or capacities, ensure that the correct capacity licenses are assigned to the correct appliance as follows: 1. Obtain the serial number for each appliance to be licensed. 2. Go to the Riverbed Support site at support.riverbed.com and click the Licenses link. 3. Enter the product serial number. This displays a table listing the serial numbers of all the SteelCentral products purchased on the same purchase order as the appliance whose serial numbers you entered. 4. Use the drop-down list boxes in the Software column for each serial number to assign the correct licenses to each appliance. Select or multi-select the licenses you want to activate for each Flow Gateway or other SteelCentral product. 5. Follow the instructions of the licensing wizard to continue the process and generate the license keys. 6. For products that do not have Internet access, email the license keys to yourself or copy and paste them into a text file for manually loading them. 7. Log in to the Flow Gateway web user interface admin account. 8. Go to the Configuration > Licenses page. 9. Click Add License(s) and paste or type the license keys into the Licenses page. When entering more than one license key, use a comma-separated list. 10. Confirm that the licenses are listed on the Configuration > Licenses page and that the status of each is green. When the license keys have been added, Flow Gateway is ready for installation verification. See Chapter 7, Installation verification. SteelCentral Flow Gateway Appliance Installation Guide 23

Licensing Next steps Next steps After the Flow Gateway has been licensed, you can log in to the web user interface and perform additional configuration on the Configuration > General Settings page, such as: Auxiliary (AUX) port - Flow Gateway can receive flow data on both the Primary and Auxiliary ports. Static Routes - If there are multiple subnets on the Aux interface network, or if you need to use a gateway router other than the default gateway, it may be necessary to define static routes. Data Sources - Flow Gateway does not require flow data to use particular ports. However, you must identify the port that the sending device is configured to send to. NetProfiler destinations - The IP addresses of additional NetProfiler or NetExpress appliances that are to receive data from Flow Gateway. Additionally, you can specify flow data forwarding destinations on the Configuration > Flow Forwarding page. Flow data is forwarded in the format in which it is received. For instructions, look in the Configuration section of the online help system. 24 SteelCentral Flow Gateway Appliance Installation Guide

CHAPTER 7 Installation verification Installation verification requires Flow Gateway to be receiving traffic data from at least one source. Verify that the appliance has been successfully installed and configured by logging in and checking the Overview page. The Overview page identifies all traffic information sources that are currently sending data to Flow Gateway. Also, it identifies destinations to which Flow Gateway forwards traffic information. Check the Overview page to confirm that Flow Gateway is receiving traffic flow data. This completes the installation process. Flow Gateway can now be turned over to those who are responsible for setting up user accounts and operational parameters. Refer to the on line help system for further configuration procedures. SteelCentral Flow Gateway Appliance Installation Guide 25

Installation verification 26 SteelCentral Flow Gateway Appliance Installation Guide

CHAPTER 8 Cloud flow data sources To provide cloud visibility, Flow Gateway receives flow data from the cloud and sends it to NetProfiler for analysis and reporting. The sources of cloud flow data include: SteelCentral AppResponse Cloud, which is the cloud version of the AppResponse 11 product. SteelCentral Agent, which is managed by SteelCentral SaaS. Amazon Web Services Virtual Private Cloud (AWS VPC) networks, via the Riverbed plug-in for the AWS CloudWatch service. SteelCentral AppResponse Cloud For instructions on configuring AppResponse Cloud to send flow data to Flow Gateway, refer to the AppResponse Cloud user documentation. SteelCentral Agent Flow Gateway can receive flow data from SteelCentral Agent to provide visibility into the cloud. This requires deploying the agent and using the SteelCentral AppInternals product to configure it. Refer to Deploying the Agent as an NPM Data Source in the AppInternals user documentation for instructions on how to deploy and configure the agent. https://doc.steelcentral.net/help/wwhelp/wwhimpl/js/html/ wwhelp.htm?context=config_reference&topic=agentnpmdatasource Amazon Web Services VPC network To configure an AWS VPC to send flow data to Flow Gateway, you must deploy an AWS Lambda script that is provided by Riverbed. Refer to the Riverbed AWS Lambda script deployment instructions on the NetProfiler page of the Riverbed Support site. SteelCentral Flow Gateway Appliance Installation Guide 27

Cloud flow data sources Amazon Web Services VPC network 28 SteelCentral Flow Gateway Appliance Installation Guide

APPENDIX A Specifications This chapter describes: Console cable wiring on page 29 Controls and indicators on page 30 Mechanical and electrical specifications on page 31 Console cable wiring The console cable provided in the accessory kit has an RJ45 connector on one end and a 9-pin D-subminiature connector on the other end. The connectors are wired as follows: RJ45 Connector 9-pin D-subminiature Connector Signal Name Description 1 8 RTS Request to send 2 6 DTR Data terminal ready 3 2 SOUT (TxD) Serial output (Transmit data) 4 5 GND Ground 5 5 RI Ring indicator 6 3 SIN (RxD) Serial input (Receive data) 7 4 DCD or DSR Data carrier detect or Data set ready 8 7 CTS Clear to send RJ45 D-subminiature SteelCentral Flow Gateway Appliance Installation Guide 29

Specifications Controls and indicators Controls and indicators Front panel The panel near the upper right corner of the front of the chassis includes the following controls and indicators: Callout Name Description A System ID button Press this button to light a blue LED in the button and on the back of the chassis. This makes it easier to identify the chassis from the front and back of the rack. B Non-maskable Interrupt This button is recessed and is not for customer use. C Primary port activity indicator When a connection is detected on the Primary (PRI) port, this green LED lights. When there is activity on the connection, the LED blinks. D Not used. E Reset button Press this button to reboot the system. F System status indicator Described below. G Power button Switches power on and off. Lights green to indicate the chassis is powered on. Lights amber to indicate a problem in the chassis. H Hard drive activity indicator Indicates hard drive activity in the chassis. I Not used. J Auxiliary port activity indicator When a connection is detected on the Auxiliary (AUX) port, this green LED lights. When there is activity on the connection, the LED blinks. System status indicator The hardware system status indicator is located on the panel near the upper right corner of the front of the chassis. It indicates the overall health of the power supplies, fans, CPU and memory chips, BMC firmware, storage devices and chassis temperature as follows: Off - the product is not operating. Green Continuously on - Normal operation. Blinking - Minor alarm. Degraded operation. The hardware platform is operating, but is not fully functional. Amber 30 SteelCentral Flow Gateway Appliance Installation Guide

Mechanical and electrical specifications Specifications Blinking - Major alarm. Non-fatal failure. The hardware platform is still operating in a degraded condition, but is likely to soon halt. Continuously on - Critical alarm. The hardware platform has failed or shut down. Disk fault indicators Each disk drive has an amber fault indicator. It is necessary to remove the bezel to see the fault indicators. Pull the left end of the bezel to remove it. To reinstall it, hook the right end on to the chassis first. The fault indicator on a disk drive lights amber continuously if the disk has failed or if it has not yet been added to the RAID configuration. Mechanical and electrical specifications The Flow Gateway requires one rack unit (1U). Regulatory compliance code: 1UACA Product model: SCFG-02270 Dimensions Height: 43.2 mm, 1.7 in. Width 438 mm, 17.2 in. Depth: 640.4 mm, 25.2 in. Weight: 11.8 kg, 26 lbs. Power: 90V-132V, 47-63 Hz 180V-264V, 47-63 Hz 117W Cooling: SteelCentral Flow Gateway Appliance Installation Guide 31