FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS:

Similar documents
212iL Rev. 1.1

9212i INSTALLATION. Stand-Alone Keypad. Instructions

232iLM Keypad Installation and Programming Instructions

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

232iLM Keypad Installation & Programming Instructions

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

2000 Series e/em Style Keypad Installation and Programming Manual

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

Outdoor Stand-Alone Weatherproof Keypads

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

Digital Keypad Introduction

SK-1011-SQ Digital Access Keypad with 5A Relay Output

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

Enter a new user. code. Enter. Enter a 2-digit user ID. Enter a user code. (from 00~09) (from 00~09) Enter

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

PAC1 Door Access Controller

PAC1 Door Access Controller

KP2000E/EM Series Style Keypad

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

DOLXFD1000B. Waterproof Access Control/Reader

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

PAC2 Dual Door Access Controller

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

AS Keypad User Manual

CP150B Vandal & Weather Resistant Keypad Security Systems

DG-800 Stand-Alone Proximity Reader Instruction Manual

SK-1011-SDQ Access Control Keypad. Manual

Installation Instructions 4291 and 4292 Keypads

SKE Series. 12-Pad. Installation & Instruction Manual. Essex Electronics, Inc KEY-LESS fax keyless.

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

CM-110SK Standalone Keypad Installation Instructions

AirTest Model CN9000 Series Sensor Controller

Stand-Alone Data Chip System

User/Installation Manual

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

K-PROX Series INSTALLATION & INSTRUCTION MANUAL. Essex Electronics, Inc KEY-LESS fax keyless.com

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

A-100 INDOOR STAINLESS STEEL KEYPAD WIRING & PROGRAMMING INSTRUCTIONS

ENTRACOMP 26SA With Remote Open Input. User/Installation Manual

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

HID EntryProx TM Keypad Reader/Door Access Control

Two Door Controller GEN-045

SECURITRON TIMEMASTER MODEL TM-2 MULTI FUNCTION TIMER INSTALLATION AND OPERATING INSTRUCTIONS

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

DSK-XXXXC DSK-XXXXP. Telephone Entry Door Intercom

Kodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

Waterproof. Keypad/Reader/Controller

EL-ST100 KEYPAD CONTROLLER

MR52 READER INTERFACE

TDM TDM. FIGURE 1 TDM Layout & Wiring Connections. Commander. Input Actions. Input Connections. Output Connections. Wet/Dry Contact Option.

TDM TDM-HC. Standard and High Current Universal Time Delay Modules INSTALLATION INSTRUCTIONS

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Proximity Card and Pin Reader Installation Manual

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

PWRguard PLUS Spring City Drive Waukesha, WI

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

eforce 150 Keyless Entry Owner s manual & User s guide For Model 3090

AP41 / AP81 SERIES TIME SWITCHES

MR51e Reader Interface

DTMF-4HC. DTMF decoder board with four high current relays. Copyright 2004 Intuitive Circuits, LLC

DTMF-8 Plus. Configurable DTMF decoder with eight high-current relays. Copyright 2002 Intuitive Circuits, LLC

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

W3-H Waterproof Keypad/Reader/Controller

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

REX F-0-9 Standalone or Access Controller

Series 803 LED Product Price Display

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

Plus-X 300. Installation and Operation Manual

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Telephone Line Monitor USER GUIDE

Single Door Standalone Access Control User Manual

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

INTELLIGENT DOCKING STATION USERS MANUAL

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Copy Machine Reader. Installation and Setup Guide

MAXIMA + Series ROTARY LEVEL CONTROL

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

Installation & Operation

CA-A480-A Elevator Controller. Reference & Installation Manual

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

CM-500 SK 500 USER CODES KEYPAD

Stand-alone Proximity Access Control

Transcription:

FEATURES AND PROGRAMMING GUIDE SELF-CONTAINED ACCESS CONTROL SYSTEMS: 233CARDREADER DOOR-GARD SELF-CONTAINED ACCESS CONTROL SYSTEMS offer field proven reliability and cost effective solutions for residential, commercial and industrial installations. Elegant yet durable, Door Gard systems blend with virtually any decor. Designed for compatibility with virtually any electric locking device, Door Gards accept power from a 12 or 24V AC/DC supply. No separate programmer is ever necessary. FEATURES: LOCK RELEASE RELAY LOCK RELEASE TIMER FORCED DOOR ALARM RELAY PROPPED DOOR ALARM RELAY ALARM ZONE SHUNTING RELAY TIMED EGRESS INPUT 120 USERS FRONT PROGRAMMING USES ANY ABA STANDARDTRACK II ENCODED MAG- NETIC STRIPE CARD MEMORY Non-volatile EEPROM memory means your users and instructions will be there whether you remove power for 5 minutes or 5 years. CARDS/MASTER CODE The Door-Gard 233 Self-Contained Access Control System allows up to 120 individual users to be valid. Any ABA standard Track II encoded magnetic stripe card may be programmed as a user. The Master Code(used to enter the programming mode) is always a code and always user one (1). FORCED DOOR RELAY Assisted by the Door Positition Sensor Loop, this 1 Amp Form-C relay will energize if the door is opened without a valid user entry or egress input. This output can be programmed to energize for up to 15 minutes or latch. It can be reset by a valid code/card entry. PROPPED DOOR RELAY Programming a 1 to 15 minute open door time allows the Door-Gard to alert you to a propped door by energizing a 1 Amp Form-C relay. Assisted by the Door Positition Sensor Loop, this relay will deenergize upon closure of the door. LOCK RELEASE RELAY This is an 8 Amp (10 Amp surge) Form-C relay which can be toggled (by code) or timed from 1 to 90 seconds. ALARM ZONE SHUNT RELAY Assisted by the Door Positition Sensor Loop, this 1 Amp Form-C relay is energized simultaneously with the Lock Release relay providing an easy means of shunting existing door contacts. The relay will continue shunting until the Door Gard sees the door close; preventing nuisance alarms (use the propped door relay instead). DOOR POSITION SENSOR INPUT By simple adding a normally closed magnetic door switch, the Door Gard system will monitor the position of the door and immediately relock it after valid access has been gained, preventing unwanted tailgate entries. PROGRAMMING Programming is accomplished by entering instructions at the front of the programming keypad and swiping cards at the reader. Multiple users may be added sequentially at the reader without returning to the keypad. LED guidance makes programming easy, and changing cards a matter of seconds for an authorized user. TIMED EGRESS INPUT Upon a momentary closure, this normally open loop will trigger the Lock Release relay for the same time period as the Master Code. KEYPRESS FEEDBACK / AUDIBLE KEYPRESS The Door-Gard 233 Self Contained Access Control System will acknowledge a keypress by momentarily sounding the sounder. This can be turned off through programming. VESTIBULE/ATM MODE This mode allows any Track II encoded magnetic stripe card to energize either the Propped Door relay, the Forced Door relay, or both. This function is especially useful when allowing access to a vestibule or automatic teller machine. A new command has been added that will energize the selected relay even if the card is not swiped properly. This is referred to as Vestibule/ATM Mode even on read error (see programming option 12). 605-3334 Rev 1.02

1 2 TESTING THE SYSTEM PROGRAMMING 1. Connect the positive (+) lead of your power supply to the terminal strip (TS1) +V input. 2. Connect the negative (-) lead of your power supply to the terminal strip (TS1) -V input. 3. Turn on your power supply. 4. Press 7890#123456*. If all 12 keypresses have been verfied, the 233 Card Reader will enter self test mode. The LED s will flash and the sounder will beep 3 times,.then sound continuously for 3 seconds (LED s on swipe will flash). If these responses do not happen, try the test mode again and then call tech support. Note: self test mode can be used whe trouble shooting a keypad in the field. If you do not get the continuous sound then the memory has been corrupt and should be re-programmed with the 46 command (see option #16). 5. Enter the master code of 1234*. The relay will energize. Refer to programming section to program your system. NOTES: The system may be programmed in your shop or at the installation site. Programmed information is stored in nonvolatile memory so it will not be lost if power is removed. ACCESS CONTROL DEFAULTS Door-Gard Self-Contained Access Control Systems are designed for easy installation in a minimum amount of time. The following defaults have been factory programmed. Master Code (user 1) 1234 * Main Relay will energize for Keypress Feedback Propped door relay will energize after Forced door relay will energize for 5 secs. On 30 secs. 10 secs. If defaults must be changed or additional functions are desired, please refer to the PROGRAMMING OPTIONS CHART after you are familiar with the PROGRAMMING section. 1. Enter programming mode Note 1 Yellow LED Press 99 # (master code) * 2. To Change master code Note 2 Press 1 # (new master code) * Press (new master code) * If main relay time must be changed, substitute option 2 from Programming Options chart for step 2 above. 3. To Add/change second user Press 2 # ** Swipe card 4. To Add/change third user Press 3 # ** Swipe card Flashes fast 5. Up to 120 users may be added in this fashion 6. Exit programming mode Press * Out NOTES: 1. Door Gard Self-Contained Access Control Systems are factory programmed with a master code of 1234 *. 2. The master code is always user 1. 3. The master code allows access to the programming mode & activates the main relay. 4. The Master Code must be followed by the *. 5. The Master Code may be from 1-6 digits in length, and digits may be repeated. 6 If the master code is forgotten or does not seem to be working, momentarily push SW1 (see wiring diagram for location) to enter programming mode and go to option #16 and default keypad. 7. If the yellow LED lights solid while in programming mode an error has occurred. Press * to clear (yellow LED should flash) and start over from step 2 or 3 above. 8. To add multiple users without returning to the keypad, refer to the Programming Options Chart: Option 17

3 PROGRAMMING OPTIONS CHART If the pre-programmed default values must be changed or additional functions are desired, the following options may be programmed. 1. Enter programming mode Press 99 # (master code) * 2. Change master code/set main relay time Note 9 Press (time) # 1 # (new code) * (new code) * Example: Master code of 4321/relay time of 10 seconds Press 10 # 1 # 4321 * 4321 * 3. Add/change user Press (user number) # * * (Swipe card) 4. Add/change user to toggle main relay Press (00) # (user number) # * *(Swipe card) 5. Delete users Press (user number) # * * 6. Turn keypress feedback/audible keypress on Press 30 # 0 # 1 # * * 7. Turn keypress feedback/audible keypress off Press 30 # 0 # 0 # * * 8. Energize Propped Door relay with any Press 31 # 0 # 1 # * * Track II card (ATM) 9. Turn above option (number 8) off Press 31 # 0 # 0 # * * 10. Energize Forced Door relay with any Press 31 # 1 # 1 # * * Track II card (ATM) 11. Turn above option (number 10) off Press 31 # 1 # 0 # * * 12. Energize Vestibule/ATM mode even on Press 31 # 2 # 1 # * * read error 13. Turn above option (number 12) off Press 31 # 2 # 0 # * * 14. Set propped door time Note 10 Press 44 # (time) # 0 # * * 15. Set forced door relay time Note 10 Press 45 # (time) # 0 # * * 16. Erase keypad memory/reset defaults Press 46 # 00000 # 00000 # * * 17. Sequentially add users Note 11 Press 53 # 1 # (starting user number) # * * (swipe first card) (swipe second card) (swipe third card) etc... NOTES: 9. Time must always be represented by 2 digits. Example: 5 seconds = 05. Latching /toggle is accomplished by entering a time of 00 10. Propped Door and Forced Door times must be programmed in intervals of 10 seconds. ie. 10, 30, 60,... up to 900 seconds. Forced door time of 00 will latch output, until reset by code/card. 11. Example: If the starting user number is (2) the first card swiped will be user (2),the next card swiped will be user (3), the next card swiped will be user (4) etc...this option cancels upon any keypress.

ELECTRICAL: VOLTAGE: 12 to 24 volts AC or DC (selected by jumper) CURRENT: @12VDC 20ma typical 50ma worst case @24VDC 25ma typical 70ma worst case Note: keypads using additional relays require an additional 15ma for each relay energized. OUTPUTS: Main relay: 8 Amp, Form-C @24VDC 10 Amp surge Alarm Zone Shunting Relay: 1 Amp, Form-C @24VDC Forced Door Relay: 1 Amp, Form-C @24VDC Propped Door Relay: 1 Amp, Form-C @24VDC 606-3334 Rev. 1.04 DOOR-GARD SELF-CONTAINED ACCESS CONTROL SYSTEMS 233 Wiring Diagrams and Specifications SPECIFICATIONS: MECHANICAL: CASE DIMENSIONS: 1.75 w x 4.50 h x 1.55 d TECHNICAL NOTES To avoid ESD (electro-static discharge) from interfering with the operation of the Door Gard, ground the negative terminal of the keypad to earth ground. If the power supply can not be grounded, then the case should be grounded. When using this device to operate an electric locking device you must install either the diode for DC voltage or the MOV for AC voltage (as shown in diagrams). They should be installed as close to the lock as possible. Installation of these devices will prevent the electrical kick back voltage generated by the locking device from damaging the keypad. If you are using AC voltage to power your Door Gard you mustinstall the MOV and appropriate resistor across your input voltage. Installation of these devices will help filter any surges or transients from the AC voltage source (as shown in diagrams) which could damage the keypad. The bi-color LED provided with this Door Gard will illuminate red when the Lock Release Relay is off, and green when the relay is energized. When mounting this unit outside, apply silicone to the area where wires enter the case. This will help prevent warm air from condensing on the circuit board. For use in extreme weather conditions, please consult the factory for additional methods of protecting your Door Gard from the environment. ENVIRONMENTAL: TEMPERATURE: -20 F to 130 F (-28 C to 54 C) To speed installation, holes have been spotted on the inside back of the housing for mounting to a wall or single-gang electrical box. Holes have been spotted on inside front of the housing for the addition of extra LED s (not included). If a door position sensor input is not used, it must by jumpered closed. PACKING CHECKLIST 233 CARD READER 233 PROGRAMMING KEYPAD THREE CONDUCTOR WIRING HARNESS (4) FOUR CONDUCTOR WIRING HARNESS (2) SLOTTED SCREWS (2) ALLEN HEAD WRENCH (1) M.O.V. (2) 100ž Resistor (1) 10ž Resistor (1) IN4004 diode (1) FEATURES AND PROGRAMMING GUIDE WARRANTY CARD

Basic Access Control with an Electromagnetic Lock Basic Access Control with an Electric Door Strike Integrated Access Control with an Electromagnetic Lock Integrated Access Control with an Electric Door Strike

Addendum: IEI 233 Card Reader for an ATM Vestibule The 233 self-contained access control card reader system can be used for an ATM Vestibule. When set up in this fashion any magnetic striped card that is ABA Standard Track II encoded (ATM cards, Debit cards, Credit Cards, etc.) will energize the main relay on the control board and unlock the door. splice 233 Control Board blue wire green wire to reader head white with orange stripe gray wire is not used white wire + - nc c no P5 brown wire SW1 Programming Notes Enter the following commands on the 233 Control Pad: 1) To enter the Programming Mode press 99 # (Master Code) * The yellow LED should now be flashing 2) 31 # 0 # 1 # * * 3) 31 # 2 # 1 # * * 4) To exit the Programming Mode press the * + - Filtered and Regulated DC Power Supply (Recommended) + - Electric Strike (fail secure) 3 2 1 P5 The IEI 233 Control Board is capable of running on 12 to 24 volts AC or DC. Because of the unreliable nature of AC voltage it is recommended that you use filtered and regulated DC voltage whenever possible. Whichever voltage you do apply to this unit make sure that the P5 jumper is set accordingly. The configuration is as follows: For 12-15 VDC the P5 jumper MUST be on pins 2 & 3 For 12-24 VAC or 16-24 VDC the P5 jumper MUST be on pins 1 & 2 Page 1 of 1 6063340 rev 1.0 FAX DOC# 2869

SELF CONTAINED ACCESS CONTROL SYSTEM STYLES: 232i-INDOOR STYLE Flushmount indoor design. 232w-WEATHER RESISTANT STYLE Flushmount outdoor design. 232r-RUGGEDIZED STYLE Weatherproof self-contained metal housing. Vandal resistant. Cast metal housing suitable for wall, post or gooseneck mounting. Available in White or Black. 232se-SEALED ENVIRONMENTAL STYLE Weatherproof self-contained metal housing. Vandal resistant. Small design suitable for residential, commercial and industrial applications. 232m-MULLION STYLE Weather resistant metal housing. Two-piece design with secured electronics. Narrow housing suitable for aluminum door frame mounting. Available in Bronze or Satin Aluminum. 234 KEYPAD CARD READER SYSTEM Weatherproof metal housing. Uses any ABA standard track II magstripe card. Access via card, keypad or both. 60 users. ACCESSORIES: DATA LOGGING IEI-250 PRINTER INTERFACE provides power, communication inputs and outputs for up to 8 Door Gard Keypads (except 233/234). Interfaces with any parallel printer for user/door activity logging. INSTALLATION IEI-280 WEATHERPROOF SURFACE BACK BOX. IEI-281 FLUSH MOUNT BACK BOX. IEI-290 12 VDC PLUG-IN POWER SUPPLY. 300MA. IEI-293 THREE RELAY PLUG--IN BOARD with FORM C, 1 Amp relays. Converts transistor outputs to dry contacts (for use with Command and Control indoor, weather resistant and mullion styles). MAGNETIC STRIPE CARDS Track II encoded, low coercivity cards. IEI-2010 Pack of 10 cards. IEI-2025 Pack of 25 cards. TAMPER PROTECTION IEI-282 TAMPER SWITCH detects faceplate removal. IEI-283 SECURITY MODULE responds to tamper switch (included) and cuts all in/out power to the door lock. Wires can t be crossed to unlock door. Must be reset from inside the protected area. IEI-289 TAMPER SCREWS - TRI-HEAD. IEI-267 1/4 DRIVER. IEI-270 ADAPTER SOCKET - TRI-HEAD. IEI-288 TAMPER SCREWS - ALLEN WITH PIN. IEI-271 TAMPER WRENCH - ALLEN WITH PIN. OTHER DOOR-GARD PRODUCTS FROM IEI CONTROL PANEL INTERFACE SERIES COMMAND & CONTROL SERIES Please call to request more information. LIMITED WARRANTY International Electronics, Inc. (IEI) warrants its products to be free from defects in material and workmanship, when they have been installed in accordance with the manufacturer s instructions, and have not been modified or tampered with. IEI does not assume any responsibility for damage or injury to person or property due to improper care, storage, handling, abuse, misuse, normal wear and tear, or an act of God. IEI s sole liability is limited to the repair or (at IEI s option) the replacement of the defective product or part when sent to IEI s facility (freight and insurance charges prepaid), after first obtaining IEI s Return Merchandise Authorization. IEI will not be liable to the purchaser or anyone else for incidental or consequential damages arising from any defect in, or malfunction of, its products. This warranty shall expire two years after shipping date for DOOR-GARD keypads. Except as stated above, IEI makes no warranties, either express or implied, as to any matter whatsoever, including, without limitation to, the condition of its products, their merchantability, or fitness for any particular purpose. INTERNATIONAL ELECTRONICS, INC. 427 TURNPIKE STREET, CANTON, MA 02021 U.S.A. 800-343-9502, 617-821-5566 617-821-4443 (FAX) FAX INFORMATION CENTER 617-821-0734 (FROM YOUR FAX MACHINE) MADE IN U.S.A. 605-3334 REV. 1.02