DOLXFD1000B. Waterproof Access Control/Reader

Similar documents
Waterproof. Keypad/Reader/Controller

W3-H Waterproof Keypad/Reader/Controller

W3-M. Metal waterproof standalone access control/reader. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

VIDI-AC-2CS Access Controller/ Reader

Single Door Standalone Access Control User Manual

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

CM-110SK Standalone Keypad Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

BC Digital Keypad. User Manual

-DTZ001- Stand-Alone Proximity Access Control. User Manual

Stand-alone Proximity Access Control

RBR-SB-KTZ001 LAR 2. User Manual

User Manual. PCKeypad Wireless Keypad

Fingerprint Access Control F1. User Manual

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

User Manual. Split access control with intelligent secured power supply.

CC Series metal access control Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

VIS-3200 / VIS-3201 User Manual

EL-ST100 KEYPAD CONTROLLER

ACCESS CONTROL SYSTEM

Installation and User Manual

Digital Keypad Introduction

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Metal Standalone Keypad Access Control S100

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

HSY-S209 EM Metal waterproof access control system User Manual

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

CV-945 Stand-Alone Biometric Reader. Installation Instructions

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

REX F-0-9 Standalone or Access Controller

Proximity Card and Pin Reader Installation Manual

Agility 2-Way Wireless Slim Keypad

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

232iLM Keypad Installation and Programming Instructions

GV-Card Reader. User s Manual

GSM CODELOCK ACCESS CONTROL UNIT

CP150B Vandal & Weather Resistant Keypad Security Systems

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

GV-AS Controller. Installation Guide

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

PR602LCD v1.0 Installer Manual Rev. A

_ Access control SISTEMAS DE SEGURIDAD

THE BRIDGE MANUAL WHAT S INCLUDED HOW IT WORKS... v There are two pieces that complete the Bridge system.

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

PAC1 Door Access Controller

2000 Series e/em Style Keypad Installation and Programming Manual

PAC1 Door Access Controller

KP2000E/EM Series Style Keypad

1. Product Specification

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Outdoor Stand-Alone Weatherproof Keypads

FTK5 PROXIMITY KEYPAD

: DOOR ENTRY UNIT USER MANUAL EIS-LCD. Programming Software. v

UC-2000 Installation Manual Unicorn Computers Technology Limited

212iL Rev. 1.1

PAC2 Dual Door Access Controller

Fingerprint Identification Proximity Reader. Quick Installation Guide

: DOOR ENTRY UNIT USER MANUAL. Programming Software. v

ACTsmart2 Product Range Operating and Installation Instructions

: DOOR ENTRY UNIT USER MANUAL EIS-R. Programming Software. v

Installing Keypad and Backplate

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

Access control panel U-Prox IC E (Elevator control)

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

Wireless Key fob, Key pad & Receiver Range

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

7612 Programming Instructions

IBA-7612 Programming Instructions

Enter a new user. code. Enter. Enter a 2-digit user ID. Enter a user code. (from 00~09) (from 00~09) Enter

232iLM Keypad Installation & Programming Instructions

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Specifications: Features:

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

AYC-F/G/M60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual

B100-SA Standalone Biometric Reader

GV-RK1352 and GV-R1352 Card Reader

2-Way Wireless I/O Expander Installation Guide

Transcription:

DOLXFD1000B Waterproof Access Control/Reader

INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to perform in a wide range of indoor, outdoor, and harsh environments. The DOLXFD1000B supports up to 1000 users in multiple access configurations (Card, PIN, or Card + PIN). The built in card reader supports HID 125KHz frequency cards. The relay can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for arming/disarming alarms, switching lights, machines.etc) The DOLXFD1000B offers advanced programming features like: Duress PIN/card; Block enrollment; Wiegand 26~37 bits interface. These features make it an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons. Features Waterproof(IP66) Vandal Resistant Enclosure One Programmable Relay Output Stand Alone or Pass-Through Operation 1000 Users (Card/PIN/Card+PIN) 10 Panic Card/PIN Codes Card Block enrollment Integrated Alarm Buzzer & Output Low power consumption (55mA) Anti-Tamper Alarm Backlit Keypad Multi-color LED status display Latch Mode to hold door or gate open 12-24V DC/ 12-18V AC Power input Specifications: User Capacity Normal User Panic User Operating Voltage Idle Current Active Current 1010 Cards/PINS 1000 10 12~24V DC/ 12-18V AC 55mA 80mA

Keypad PIN length Proximity Card Reader Radio Technology Read Range Wiring Connections Relay Adjustable Relay Output Time Adjustable Alarm Output Time Lock Output Load Alarm Output Load Environment Operating Temperature Operating Humidity Physical Surface Finish Dimensions Unit Weight Shipping Weight Package Contents: 12 Key (3*4) 4-6 digits HID 125KHz Industry Standard Proximity Card 3-6cm Electric Lock, Exit Button, DOTL, External Alarm, Wiegand ONE (NO, NC, COM) 1-99 Seconds (5 seconds default) 0-99 minutes (1 minute default) 5 Amp Maximum 3 Amp Maximum Meets IP66-30 C~60 C, or -22 F ~ 140 F 10% ~ 90% Non-Condensing Zinc-Alloy Enclosure Powder Coat L: 4 ¾* W: 3 * H: 1 (inches) 21 oz. 24 ¾ oz. Diode IN4004 (For relay circuit protection) Self Tapping Screws Wall Anchors DOLXFD1000B Access Controller Screw Driver Manager Cards

INSTALLATION Install Remove the back cover from the unit Drill 2 holes(a,c) on the wall for the screws and one hole for the cable Knock the supplied rubber bungs to the screw holes(a,c) Thread the cable through the cable hole (B) Attach the unit to the back cover. Wiring Wire Insulation Color Function Notes Basic Standalone Wiring Red AC&DC 12~24V DC / 12-18V AC Regulated Power Input Black AC&DC 12~24 Volts AC/DC Regulated Pink GND Negative Pole Blue NO Normally Open Relay 1 Output Purple COM Common Connection for Relay 1 Output Orange NC Normally closed Relay 1 Output Yellow OPEN Request to Exit Button

Advanced Input and Output Features Green D0 Wiegand Input/Output D0 White D1 Wiegand Input/Output D1 Grey Alarm - Alarm Negative Brown D_IN Door status detecting CONNECTION DIAGRAM Common Power Supply DOLXFD1000B

Access Control Power Supply DOLXFD1000B To Reset to Factory Default To reset to factory default, power off, press *, hold it and power on, release it until hear two beeps and the LED shines in orange, then read any two HID cards, the LED will turn in red, means reset to factory default setting Add Card, the second one becomes the Manager Delete Card. NOTE: Reset to factory default, the user s information is still retained. Anti Tamper Alarm The DOLXFD1000B uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the cover then the tamper alarm will operate. Sound and Light Indication Operation Status Red Light Green Light Yellow Light Buzzer Power on Bright - - Short Ring Stand by Bright - - -

Press keypad - - - Short Ring Operation successful - Bright - Short Ring Operation failed - - - 3 Short Rings Enter into programming Bright - - Short Ring In the programming - - Bright - Exit from the programming Bright - - Short Ring Open the door - Bright - Short Ring Alarm Bright - - Alarm PROGRAMMING COMMANDS PROGRAMMING MODE (IMPTANT!) All of the following commands require the keypad to be in programming. Make sure that the light is blinking red before proceeding. If not, press * until it blinks red IMPTANT! if at any time the reader gives 3 beeps - the programming command is invalid, try again. *, MASTERCODE, # The keypad s light should be a solid red indicating that it is in Default Master Code: 666666 Programming Mode. * To exit Programming. The light will be blinking red to indicate that Programming has ended CHANGING MASTER CODE 0, New Code, #, New Code, # Master code needs to be 6 digits long

COMMANDS TO ADD PIN/CARDS CARD PIN MODE (default) All of the following commands are for CARD PIN MODE 30# Card or PIN, Otherwise continue programming ADD A PIN USER 1, User ID, #, PIN, # Repeat this step to add more Users User Number Range: 1-1000 PIN Range: 4 6 digits PIN: 1234 is reserved and cannot be used ADD MANAGER CARD 1, Read Card, # Repeat this step if necessary. User ID will automatically be assigned 1, User ID, #, Read Card, # Repeat this step if necessary. User ID may be defined after this step. ADD CARDS (BLOCK ENROLLMENT) 5, User ID (or memory space # 1-1000), #, The number of the first card (8 digits, both facility code and serial number), #, Quantity of cards to enroll, # Cards must be consecutive and card quantity is between 1-1000. Use this command to add specific card numbers.

CARD PIN MODE (continued) DELETE PIN USER 2, User ID (or memory space # 0-999), # Repeat this step if necessary DELETE CARD 2, Read card, # Repeat this step if necessary DELETE CARD BY USER ID 2, User ID (or memory space # 0-999), # Repeat this step if necessary DELETE CARD BY CARD NUMBER 2, Card Number # Repeat this step if necessary

CARD AND PIN MODE All of the following commands are for CARD AND PIN MODE 31# Card and PIN, Otherwise continue programming ADD CARD AND PIN USER 1, Read Card, # Repeat this step if necessary. User ID will automatically be assigned 1, User ID (or memory space # 0-999), #, Read Card, # Repeat this step if necessary. User ID may be defined after this step. 5, User ID (or memory space # 0-999), #, The number of the first card (8 digits, both facility code and serial number), #, Quantity of cards to enroll, # Cards must be consecutive and card quantity is between 1 1000. Use this command to add specific card numbers. *, * Exit programming. Make sure that the light is blinking red before proceeding. If not, press * until it blinks red *, Read card, 1234, #, PIN, #, PIN, # The PIN can be 4-6 digits. 1234 is reserved. DELETE CARD AND PIN USER 2, Read card, # Simply delete the card 2, User ID (or memory space # 0-999), # 2, Card Number #

CARD ONLY MODE All of the following commands are for CARD ONLY 32# Card only, Otherwise continue programming ADD CARD 1, Read Card, # Repeat this step if necessary. User ID will automatically be assigned 1, User ID (or memory space # 0-999), #, Read Card, # Repeat this step if necessary. User ID may be defined after this step. 5, User ID (or memory space # 0-999), #, The number of the first card (8 digits, both facility code and serial number), #, Quantity of cards to enroll, # Cards must be consecutive and card quantity is between 1-1000. Use this command to add specific card numbers. DELETE CARD USER 2, Read card, # Repeat this step if necessary 2, User ID (or memory space # 0-999), # Repeat this step if necessary 2, Card Number # Repeat this step if necessary GENERAL COMMANDS DELETE ALL USERS 2, 0000, #

USING MANAGER ADD/DELETE CARDS Read Manager Add Card, Read Card, Read Manager Add Card Cards may be added continuously before reading the Manager Add Card a second time. Read Manager Delete Card, Read Card, Read Manager Delete Card Cards may be added continuously before reading the Manager Delete Card a second time. HOW TO UNLOCK DO IN DIFFERENT MODES PIN, # Read Card Read Card, PIN, # For PIN CARD For PIN CARD, and CARD ONLY For PIN AND CARD PULSE MODE 4, Seconds, # Seconds = 1-99. Default is 5 seconds. TOGGLE LATCH MODE 4, 0, # KEYPAD BACKLIGHT 74, # Disable keypad's backlight 75, # Enable keypad's backlight (Default)

RED LED 76, # Disable keypad's red LED 77, # Enable keypad's red LED (Default) SOUND 78, # Disable the sound 79, # Enable the sound OPEN DO ALARM With a door detecting switch, a door open for longer than 1 minute will sound an alarm. If the door is forced open, the alarm will activate for a defined 0-3 minutes. Disable: 60, # Enable: 61, # Default ALARM OUTPUT TIME Use this if OPEN DO ALARM is enabled 9, Minutes, # Minutes: 0-3. Default is 1 minute.

KEYPAD LOCKOUT If 10 invalid cards/pins in a 10 minute window are presented, the keypad will lock for 10 minutes or sound activate the alarm depending on the settings Disable: 70, # Lock keypad: 71, # Alarm activation: 72, # Default ADD DURESS PIN 8, User ID (or memory space # 0-999), #, PIN, # Entering a Duress code will open the door and activate alarm. User ID: 1001-1010 DELETE DURESS PIN 2, User ID (or memory space # 0-999), # * Press * again to exit programming ADD DURESS CARD 8, User ID (or memory space # 0-999), #, Read card, # * Press * again to exit programming DELETE DURESS CARD 2, User ID (or memory space # 0-999), # * Press * again to exit programming WIEGAND MODE 9, Bit, # Bit: 26-37. Default: 26

PASS-THROUGH OPERATION DOLXFD1000B operating as a Wiegand Output Reader In this the DOLXFD1000B supports a Wiegand 26~37 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26~37 bit input. DOLXFD1000B Transmission Format: 1) Keypad Transmission: The Reader will transmit the PIN data when it receives the last key (#) press after PIN code. Format: PIN Code (any 4~8 digits between 0000~999999) Example: PIN code: 111111 Press 111111 #, then the output format will be: 0000111111 (Note: if press an invalid PIN (any 4~6 digits), the data will be also transmitted.) 2) Proximity Card Transmission The Reader will transmit the card data when it reads the Card. Format: Card Number (Note: no matter the card is valid or invalid, the data will be transmitted)

DOLXFD1000B operating as a Controller DOLXFD1000B supports a Wiegand 26~37 bit input so an external Wiegand device with a 26~37 bit output can be connected to the Wiegand input terminals on the DOLXFD1000B. Either an ID card reader (125 KHz) or an IC card reader (13.56MHz) can be connected to the DOLXFD1000B. Cards are required to be added at the external reader, except where an external HID reader is used, in this case cards can be added at either reader or controller. See figure 2. DOLXFD1000B Figure 2

DOLXFD1000B Simplified Instruction Function Description Enter the Programming Mode Operation * Master Code # (666666 is the default factory master code) Change the Master Code 0 New Master Code # Repeat New Master Code # (code: 6 digits) Add Card User 1 Read Card # Add PIN User 1 User ID # PIN # The ID number is any memory space between 0 ~ 999.The PIN is any 4-6 digits between 0000 ~ 999999 Delete User 2 Read Card # 2 User ID # Exit from the programming * How to be granted access. Card User Read card PIN User Enter PIN #

TRANSMITTER SOLUTIONS WARRANTY The warranty period of Transmitter Solutions keypad is twenty-four (24) months. This warranty shall begin on the date the keypad is manufactured. During the warranty period, the product will be repaired or replaced (at the sole discretion of Transmitter Solutions) if the product does not operate correctly due to a defective component. This warranty does not extend to (a) the keypad case, which can be damaged by conditions outside the control of Transmitter Solutions, or (b) battery life of the keypad. This warranty is further limited by the following disclaimer of warranty and liability: EXCEPT AS SET FTH ABOVE, TRANSMITTER SOLUTIONS MAKES NO WARRANTIES REGARD- ING THE GOODS, EXPRESS IMPLIED, INCLUDING WARRANTY OF MERCHANTABILITY WARRANTY OF FITNESS F A PARTICULAR PURPOSE. BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS, EXPRESS IMPLIED, WITH REGARD TO THE GOODS AND ACCEPTS THEM AS-IS/WHERE-IS. TRANSMITTER SOLUTIONS SELLS THE GOODS TO BUYER ON CONDITION THAT TRANSMITTER SOLUTIONS WILL HAVE NO LIABILITY OF ANY KIND AS A RESULT OF THE SALE. BUYER AGREES THAT TRANSMITTER SOLUTIONS SHALL HAVE NO LIABILITY F DAMAGES OF ANY KIND, WHETHER DIRECT, INCIDENTAL CONSEQUENTIAL DAMAGES, INCLUDING INJURIES TO PERSONS PROPERTY, TO BUYER, ITS EMPLOYEES AGENTS, AS A RESULT OF THE SALE. BUYER ALSO AGREES TO HOLD TRANSMITTER SOLUTIONS HARMLESS FROM ANY CLAIMS BUYER, ANY THIRD PARTY, MAY HAVE AS A RESULT OF BUYER S USE DISPOSAL OF THE GOODS. BUYER HAS READ THIS DISCLAIMER AND AGREES WITH ITS TERMS IN CONSIDERATION OF RECEIVING THE GOODS.