Page 1 MRK-D-0011, V1.1 Aeroqual SM50 User Guide

Similar documents
Page 1 MRK-D-0011, V2.0 Aeroqual SM50 User Guide

Contents. MRK-D-0017, V2 Aeroqual SM70 User Guide Page 2

Page 1 MRK-D-0017, V1 Aeroqual SM70 User Guide

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

ES-600 Ozone Controller Operation Manual

OZONE SWITCH Model OS-6. OS-6 Features

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

RXTH DUAL ROOM SENSOR / SWITCH

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

ZBXYAF Oxygen sensor control circuit board

RXTP ROOM TEMPERATURE

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

MOD-RI Room Interface Modules with Modbus

Model 305e OEM CO 2 concentration sensor

Carbon Monoxide Sensor - ModBus

OEM Digital NDIR CO 2

OEM Digital NDIR CO sensor

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

TOXALERT MODEL AIR 2000

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

KCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement

RТTH DUAL ROOM SWITCH

2.2 Main technical parameters. Detection range. 0~5%vol(0~100%vol optional) Warm-up time. SPAN <±500ppm Long-term drift

General. Copyright 2013 EXSEN Company. All Rights Reserved. Rev /5/2013 Page 1 of 6

Manual iaq-engine Indoor Air Quality sensor

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

Series 900 & 905 Transmitter/ Controller. User Guide

Contents. MRK-D-0009, V3 Page 2 Aeroqual Series 940 User Guide

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Aeroqual Series 900 User Guide

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

Rev 1.3, Air-Farm User Manual. CO2 / Temperature / Humidity Transmitter

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Product Specification. tsense VAV. CO 2 -, Temperature- and RH- sensor in a housing with colour touch display

LD-RTD / LD-TC Temperature Controller

RTD-W Installation Instructions

SCDM88-8x8 Serial LED Dot Matrix Display Module. Serial Interface. Serial Command Summary

Intelligent Infrared CO 2 Gas Sensor. (Model: MH-711A) Manual. Version: 3.3. Valid from: May 1st, 2014

PCD DIGITAL Differential pressure probe

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

TPE 1464 Series Pressure Transducer

Suprex RS-485 SPX-7500 Wired Reader-Extender

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

NSGV Series "90DM3" Carbon Dioxide Detector

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

SPX-7400_SPX-7410_MAN_161028

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Manual and Protocol Description

CDD Carbon Dioxide Transmitter

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR

Product Specification. CO 2 Engine ICB. Sensor module for bio applications

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

dual-line 6-dIGIt process MeteR

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

HRT-710. User s Manual Version HRT-710 User Manual (Version 1.23, Dec/2012) PAGE: 1

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Trueyes Inc. Carbon Dioxide (CO2) Module

Instruction Manual CTC-1

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

RTD-NET Installation Instructions

SC2004MBS 20x4 Characters MODBUS RTU Slave LCD

MC CO MODBUS ADDRESSABLE SENSOR

GM 500A Mifare Read/Write Module V1.0 GM 500A Mifare 13.56MHz Read/Write Protocols Interface (I2C/UART) User s Manual

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

CVX-1300 DataBender! Universal Format Converter!

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

Gas and Air Sensors. Product Specification. CO 2 Engine K30. Sensor Module and OEM Platform. Document PSP 110. Rev 4. Page 1 (11)

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

ALTA Serial Modbus (RTU/ASCII) Gateway Quick Start Guide

Temperature and humidity module DHT11 Product Manual

Model Ultima OPIR-5. Infrared Open Path Gas Detector HART Field Device Specification. Instruction Manual

DataNab it8: Intelligent Communicating Thermostat

Product Specification. CO 2 Engine K33-LP T. Sensor Module and OEM Platform. Document PSP0120. Rev 4. Page 1 (13)

T1K MODBUS Base Controller Specifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Combustion gas and odorous gases within the room (smoke, body odor, timber dope Gas detected

HMC1022 Digital Compass

Manual iaq-core Indoor Air Quality sensor module

KTA-250 Anemometer Alarm Card

DIFFERENTIAL PRESSURE TRANSMITTER with MODBUS interface Optional Input module

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Ethernet to Digital I/O +RS232 +Switch

MODEL IR5500 Infrared Open Path Gas Detector HART Field Device Specification

Multi-Point Gas Detection and Control System

OEM-ORP ORP. Reads mV mV. Range. 1 reading every 420ms. Response time. Any type & brand. Supported probes. Single point.

EXCELL PRECISION CO., LTD.

Instruction and Operation Manual

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

Transcription:

Page 1

Table of Contents 1. Description... 3 2. Operating Instructions... 3 2.1. Power... 3 2.2. Warm Up... 3 2.3. Input and Output signals... 3 2.3.1. ZERO CAL... 4 2.3.2. RESET... 4 2.3.3. SPAN... 4 2.4. Using the Relay Output... 4 2.4.1. Setting the Relay and Alarm Set Point... 5 2.4.2. Connecting to the Relay Outputs... 6 2.5. Status LED (Normal and Failure modes)... 6 2.5.1. Relay LED... 6 2.6. Using the Analog 0-5V Output... 7 2.7. Using the Serial Digital Communications... 7 3. Specifications... 8 4. Mounting Dimensions... 9 5. Appendix... 10 5.1. RS232 Protocol... 10 5.2. RS485 Protocol... 13 Page 2

1. Description The Aeroqual SM50 range of gas sensor modules provides state of the art gas measurement in a flexible cost effective package. They utilise Aeroqual s GSS Technology to provide reliable and sensitive measurement for a wide range of gases. There are two gas response specifications available - Standard for industrial process control or leak detection applications and High Spec for low level ambient gas measurements. Furthermore the modules are available in diffusion, fan and pump sampling versions. Please consult your Aeroqual Business Development Manager for further information. Each SM50 module is calibrated to give a linear output with gas concentration. There are multiple outputs fitted as standard including diagnostic LEDS, 0-5V signal, relay, RS232, and RS485 digital communications. I2C is available as an option. Standard inputs include dipswitch settings for the relay and calibration buttons. Optional inputs include two analog voltages. MICROMATCH CONNECTORS (SCREW TERMINALS AVAILABLE ON UNDERSIDE) ZERO CAL BUTTON RESET BUTTON SPAN CAL BUTTON* RELAY LED STATUS LED OPTIONAL INPUTS GSS SENSOR RELAY SET POINT DIP SWITCHES * This button will change the span calibration of the SM70 and should not be activated for any reason 2. Operating Instructions 2.1. Power The SM50 module will run off a DC input voltage in the range 11-24 VDC. Connect power to the V+ and GND screw terminal connectors or to the VIN and GND pins on the micromatch connectors. Power consumption varies depending on the SM50 sensor in the range 2.5 to 6W. 2.2. Warm Up The SM50 module is designed to run continuously. On first time use or after a period of non-use the SM50 module should be run for a couple of hours to burn off contaminants on the sensor. When power is switched on the SM50 will warm up for 3-10 minutes before full operation. 2.3. Input and Output signals The SM70 sensor board contains a number of buttons, LEDs and a dipswitch. Page 3

2.3.1. ZERO CAL This button activates a zero calibration routine on the sensor. It should only be pushed when you are performing a zero calibration. 2.3.2. RESET This button resets the SM50 without needing to remove the power from the SM50. 2.3.3. SPAN This button will change the span calibration of the SM70 and should not be activated for any reason. 2.4. Using the Relay Output The SM50 sensor module can be used as a simple gas sensitive relay switch to control devices or activate alarms using the on board relay. Three relay control software options are available: AA, AB, C10. The user should specify the software prior to delivery. The relay logic of the three software versions is described below. External equipment connected to the on-board relay should be wired appropriately to the normally open or normally closed contacts AA Alarm-Above: the relay is programmed to energise or activate above the selected set point. Typical applications are health and safety alarm/warning systems or switching external equipment on and off. This is the default software. Relay closed (energised) Set Point Relay open (de-energised) When gas concentration is rising from below the Set Point, relay de-energised (relay NO=open, NC=closed) When gas concentration rises and reaches the Set Point, relay is energised (relay NO= closed, NC = open) When gas concentration drops and reaches the Set Point, relay de-energised (relay NO=open, NC=closed) AB Alarm-Below: the relay is programmed to energise or activate below the selected set point. Typical applications are fail safe warning systems or controlling a gas generator. Relay open (de-energised) Set Point Relay closed (energised) Page 4

C10 When gas concentration is rising from below the Set Point, relay energised (relay NO= closed, NC = open) When gas concentration rises and reaches the Set Point, relay is de-energised (relay NO= open, NC = closed) When gas concentration drops and reaches the Set Point, relay energised (relay NO=closed, NC=open) The relay is programmed to open and close around the selected control set point ±10% to create a control band. Typical application is for maintaining a specific gas concentration between user defined levels through the control of an external device e.g. ozone generator. Upper Limit 110% 100% Relay closed (energised) Relay open (de-energised) Set Point Software Control Band ±10% of set point 90% Lower Limit When the gas level is rising from below Lower Limit to Upper Limit, relay is energised, (NO=closed, NC = open) When gas level is falling from above Upper Limit to Lower Limit, relay is de-energised (NO=open, NC = closed) 2.4.1. Setting the Relay and Alarm Set Point The Relay Set Point can be altered by adjusting the set-point dip-switches as shown below. The Relay Set Point is factory set (unless otherwise specified) to OFF-ON-OFF-ON. The set point levels for different dipswitch settings are provided below for some sensors. Contact Aeroqual if your sensor is not listed. Note: The relay and sensor diagnostics are inactive during the warm up period. Relay dipswitch (1 2 3 4) O3 0-0.150 (ppm) O3 0-0.500 (ppm) O3 0-10 (ppm) VOC Isobutylene (ppm) on on on on 0.000 0.000 0.00 0 off on on on 0.010 0.025 0.50 1 on off on on 0.020 0.050 1.00 2 off off on on 0.030 0.075 1.50 3 on on off on 0.040 0.100 2.00 4 off on off on * 0.050 0.125 2.50 5 on off off on 0.060 0.150 3.00 6 off off off on 0.070 0.175 3.50 7 on on on off 0.080 0.200 4.00 8 off on on off 0.090 0.225 4.50 9 on off on off 0.100 0.250 5.00 10 off off on off 0.110 0.300 6.00 12 on on off off 0.120 0.350 7.00 14 off on off off 0.130 0.400 8.00 16 on off off off 0.140 0.450 9.00 20 off off off off 0.150 0.500 10.00 25 * Factory default setting Page 5

2.4.2. Connecting to the Relay Outputs The relay output is a set of volt-free contacts that can be used to trigger an external device directly (max. 24V @ 2A) or for a higher voltage and current loads via a secondary relay. A typical external device is an alarm bell, siren, extractor fan, etc. When the relay is energised (the red relay LED will light up) the normally open (NO) will short to common (COM) and the normally closed (NC) will be open with respect to COM. Connect the desired external device to the normally open (NO), normally closed (NC) and COM contacts on the screw terminal as shown below. EXTERNAL DEVICE e.g. O3 generator Insert jumper wire between Com and GND Com NO GND V+ Insert diode in circuit to suppress back EMF Diode IN4004 External relay must be suitably rated to switch the external load Operating voltage of relay coil must be 12 VDC L N E 240 VAC 2.5. Status LED (Normal and Failure modes) The status LED glows green and is located on the Sensor board. At start up, the Status LED will flash 2 to 6 times at an interval of 0.5 seconds. During the 3 to 10 minute warm-up time, the Status LED will flash at an interval of 2 seconds. Normal status: Constant on Sensor Failure: Flashes quickly at an interval of 0.3 seconds. 2.5.1. Relay LED The relay LED glows red and is also located on the Sensor board. This LED comes on when the relay is energised. Page 6

2.6. Using the Analog 0-5V Output The gas concentration is available as a 0-5V signal at the 0-5V and AGND connectors on the screw terminal block. 0 volts = zero ppm and 5 V = designated range of sensor (for example, a 0-0.5 ppm O3 SM70 module would output 5V at 0.500 ppm ozone). The resolution of the analog signal is 8 bit. Note: The 0-0.150ppm O3 sensor analogue output is 1.5V at 0.150ppm (full scale). All other sensors output 5.0V at full scale. 2.7. Using the Serial Digital Communications Gas concentration data is available on the RS232 and RS485 digital communication channels. The RS485 channel is 2-wire, the RS232 is 2-wire plus GND. Connection is via the screw terminal connectors on the sensor board. The communication protocols for these serial interfaces are provided in the Appendix. Please note: the RS232 serial protocol is a proprietary format and is not ASCII. Hence a terminal program cannot be used to communicate with the SM50. Program Connector Communication Connector Display Connector 10 1 8 1 4 1 Program Connector PIN 1 2 3 4 5 6 7 8 9 10 CONFIG. VCC (5V) BUSY Communication Connector CLK R x D RS485 GND RESET CNV T x D RS485 N/A VIN (11-24V) PIN 1 2 3 4 5 6 7 8 CONFIG. VIN GND METER_TX METER_RX (11-24V) (RS232) (RS232) Display Connector PIN 1 2 3 4 CONFIG. GND VCC (5V) SCL (clock) SDA (data) SPAN ZERO 0-5V OUT (analog) AGND (analog GND) Page 7

3. Specifications Power Input Consumption 11-24 VDC 2.5-6 W max Outputs 0-5V analog 8 bit Relay Onboard 24VDC / 2A, NO, NC, COM 2 x LED indicators Relay status Red = activated Sensor status Green = normal Green slow flash (2 seconds) = warming up Green fast flash (0.3 seconds) = failure RS232 2-wire proprietary protocol (not ASCII) RS485 2-wire proprietary protocol (not networkable) Inputs Relay set points Zero calibration Reset Span calibration Analog inputs 4-way dip switch Auto-calibration zero button Microprocessor reset button Factory use only 2 Voltage (optional) Diagnostics If sensor failure then:- Status LED fast green flash Relay AA version (energised) LED red AB version (de-energised) LED off C10 version (de-energised) LED off 0-5V analog output 5V Mechanical Board Size Mounting Fan (if required) Sensor filter 60 mm x 75 mm Screw or extrusion slot On-board ball-bearing 50,000 hours On-board Environmental Operating temperature Operating humidity 0ºC to 50ºC (-20ºC to 50ºC if enclosed) 5% to 95% RH (non-condensating) Approvals Page 8

14mm 4mm 67mm 4mm 75mm 4. Mounting Dimensions The mounting points and dimensions are given below for an SM50 ozone sensor. Individual SM50 modules may differ slightly to that shown. HOLES 4mm Ø 15mm 15mm TEFLON TUBE 16mm Ø ID 19mm Ø OD 30mm long 30mm 30mm 10-14mm 16-20mm TEFLON TUBE 16mm (min) 20mm (max) protrusion outside the enclosure 5.5mm 49mm 60mm 5.5mm 1.5mm Page 9

5. Appendix 5.1. RS232 Protocol The Aeroqual OEM sensor s digital information output is based on the following RS232 protocol. These command protocols are specified by Aeroqual Limited, all rights reserved. Aeroqual reserves the right to change the protocol without notification. Version 2.2 Date: 23-09-2009 * Added zero calibration function. * Combined with temperature and relative humidity sensor data. Section 1. Descriptions of communication commands (for data format and representations please refer to section 3). Comma and spaces are not applied for every command and reply data stream, they are just used for clearly specifying data stream: 1. OEM sensor regular data report command; the data report interval varies with sensor. It is 15 bytes data stream: SENSOR, DATA_REPORT, DATA1, DATA2, DATA3, RESERVED2, STATUS1, STATUS2, CHECKSUM * SENSOR - 1 byte monitor reply data stream header, see section 2 for its value. * DATA_REPORT - 1 byte data report command, see section 2 for its value. * DATA1-4 bytes floating point data, gas concentration value. * DATA2-2 bytes unsigned int used for optional sensors of temperature reading, its value scaled up by 10. that means if the reported value is 256, then the actual reading is 25.6 Celsius degree. * DATA3-2 bytes unsigned int used for optional sensors of relative humidity reading, its value scaled up by 10. that means if the reported value is 515, then the actual reading is 51.5%. * RESERVED2 - is 2 bytes reserved. * STATUS1-1 byte sensor status indication, refer section 3 for details. * STATUS2-1 byte sensor status indication, refer section 3 for details. * CHECKSUM - 1 byte the data stream's check sum - that makes the command stream total sum is zero. 2. OEM sensor information request command: Command RECEIVER, SENSOR_INFO, RESERVED1, CHECKSUM Reply SENSOR, SENSOR_INFO, VERSION_NO, DISPLAY, NMAE_LENGTH, SENSOR_NAME, RESERVED2, CHECKSUM * RECEIVER - 1 byte information request command header, see section 2 for its value. * SENSOR - 1 byte monitor reply data stream header, see section 2 for its value. * SENSOR_INFO - 1 byte command see section 2 for its value * VERSION_NO - 1 byte sensor version number, see section 2 for its value. * DISPLAY - 1 byte, gas concentration value display format type, see section 2 for its value. * NAME_LENGTH - 1 byte specify the sensor name byte length * SENSOR_NAME - 7 bytes, the gas sensor name ASCII code, its valid bytes are specified by NMAE_LENGTH * RESERVED1-1 bytes reserved use value 0x00. * RESERVED2-2 bytes not used. Page 10

* CHECKSUM - 1 byte the data stream's check sum - that makes the command stream total sum is zero. 3. OEM sensor concentration ppm to mg/m3 conversion factor request command: Command Reply RECEIVER, CONVERT_FACTOR, RESERVED1, CHECKSUM SENSOR, CONVERT_FACTOR, FACTOR, RESERVED8, CHECKSUM * SENSOR - 1 byte monitor reply data stream header, see section 2 for its value. * CONVERT_FACTOR - 1 byte command see section 2 for its value * FACTOR - 4 bytes floating point conversion factor value, see section 3 for details. * RESERVED1-1 bytes reserved use value 0x00. * RESERVED8-8 bytes reserved. * CHECKSUM - 1 byte the data stream's check sum - that makes the command stream total sum is zero. 4. OEM sensor zero calibration command, 4 bytes: Command RECEIVER, ZERO_CAL, RESERVED1, CHECKSUM * ZERO_CAL - 1 byte (0x12) command to start zero calibration for the sensor, see section 2 for its value. * RESERVED1-1 bytes reserved use 0x00. * CHECKSUM - 1 byte the data stream's check sum - that makes the command stream total sum is zero. * During zero calibration OEM status LED will slowly flash, once the flash finished, zero calibration * finished too. Section 2. Protocol command values: RECEIVER = 0x55 //header command used for receiver command SENSOR = 0xAA //header command used for monitor reply DATA_REPORT = 0x10 //regular data report command ZERO_CAL = 0x12 //zero calibration command SENSOR_INFO = 0xFB //parameters upload command CONVERT_FACTOR = 0x2A //update monitor real time clock RESERVED = 0x00 //the byte not been used for information transfer CHECKSUM a data stream's check sum - that makes the command stream total sum is zero. DISPLAY display format can be following: = 0x01-1 digit int, 3 decimal points, eg. 0.500 ppm = 0x02-2 digits int, 2 decimal points, eg. 12.20 ppm = 0x03-3 digits int, 1 decimal point, eg. 126.8 ppm = 0x04-4 digits int, no decimal point, eg. 2888 ppm STATUS1 8 bits monitor and sensor status information SS0 * b0 \ 00 sensor working fine, SS1 * b1 / 01 sensor failure, 11 sensor aging (for O3 LOW sensor only). Reserved1 Reserved2 Reserved3 Reserved4 * b2 Reserved not been used * b3 Reserved not been used * b4 Reserved not been used * b5 Reserved not been used Page 11

Reserved5 Reserved6 * b6 Reserved not been used * b7 Reserved not been used STATUS2 8 bits monitor and sensor status information Reserved0 * b0 Reserved not been used Reserved1 * b1 Reserved not been used Zeroing * b2 = 0 sensor normal working mode * b2 = 1 sensor zeroing Reserved2 * b3 Reserved not been used Reserved3 * b4 Reserved not been used Reserved4 * b5 Reserved not been used Reserved5 * b6 Reserved not been used Reserved6 * b7 Reserved not been used Section 3. Data value format representation: The floating point data values use IEEE754 32 bits floating point little ending representation. They are: DATA1 and FACTOR Section 4. Data transfer mechanism 1. Due to the monitor main chips feature, 4 bytes floating point data and 2 bytes int data send sequence are low byte first, high byte last, such as section 3 data DATA1, DATA2, ADAT3 and FACTOR. 2. For regular data report: The OEM sensor will automatically send out a measured data result to the RS232 serial port according to sensor type. The data report interval will vary with different sensors. The longest report interval is about 2 minutes, the shortest one is only 2 seconds. Please ask Aeroqual for this information when needed. Section 5. RS232 communication port settings: Baud rate: 9600 Data bits: 8 Stop bits: 1 Parity: none Flow control: none Page 12

5.2. RS485 Protocol The Aeroqual OEM sensors digital information output is available on RS485. These command protocols are specified by Aeroqual Limited, all rights reserved. Aeroqual keep the rights to change the protocol without notification. Version 1.0 Date: 05-12-2008 Section 1. Descriptions of communication commands (for data format and representations please refer to section 3). Comma and spaces are not applied for every command and reply data stream, they are just used for clearly specifying data stream: Aeroqual OEM sensor module RS485 protocol is a slave mode. Master receivers need send request command to get response. 1. OEM sensor data request command, it is 4 bytes data stream: BASE, DATA_REQUEST, RESERVED, CHECKSUM example: 0x55, 0x1A, 0x00, 0x91 Reply data stream is 15 byte. SENSOR, DATA_REPORT, DATA1, DATA2, RESERVED, STATUS1, STATUS2, CHECKSUM The second byte (DATA REPORT) will be either 0x1A or 0x0F or 0x10. Only if DATA REPORT = 0x10 will DATA1 be a valid concentration reading. * SENSOR - 1 byte monitor reply data stream header, see section 2 for its value. * DATA_REQUEST - 1 byte heater data report, see section 2 for its value. * DATA_REPORT - 1 byte gas concentration data report command, see section 2 for its value. * DATA1-4 bytes floating point data, when command reply is DATA_REPORT, this value is gas concentration in ppm, * DATA2 - reserved * RESERVED - is 2 bytes data space reserved. * STATUS1-1 byte monitor and sensor status indication, refer section 3 for details. * STATUS2-1 byte reserved. * CHECKSUM - 1 byte the data stream's check sum - that makes the command stream total sum is zero. 2. OEM sensor information request command: Command BASE, SENSOR_INFO, RESERVED, CHECKSUM Reply SENSOR, SENSOR_INFO, VERSION_NO, DISPLAY, NMAE_LENGTH, SENSOR_NAME, RESERVED, CHECKSUM * BASE - 1 byte information request command header, see section 2 for its value. * SENSOR - 1 byte monitor reply data stream header, see section 2 for its value. * SENSOR_INFO - 1 byte command see section 2 for its value * VERSION_NO - 1 byte sensor version number, see section 2 for its value. * DISPLAY - 1 byte, gas concentration value display format type, see section 2 for its value. * NAME_LENGTH - 1 byte specify the sensor name byte length Page 13

* SENSOR_NAME - 7 bytes, the gas sensor name ASCII code, its valid bytes are specified by NMAE_LENGTH * RESERVED - 1 byte * CHECKSUM - 1 byte the data stream's check sum - that makes the command stream total sum is zero. Section 2. Protocol command values are in hexdecimals not ASCII: BASE = 0x55 //header command used for receiver command SENSOR = 0xAA //header command used for monitor reply DATA_REPORT = 0x10 //regular data report command DATA_REQUEST = 0x1A //heater data request/report command SENSOR_INFO = 0xFB //parameters upload command RESERVED = 0x00 //the byte not been used for information transfer CHECKSUM * a data stream's check sum - that makes the command stream total sum is zero. DISPLAY * display format can be following: = 0x01-1 digit int, 3 decimal points, eg. 0.500 ppm = 0x02-2 digits int, 2 decimal points, eg. 12.20 ppm = 0x03-3 digits int, 1 decimal point, eg. 126.8 ppm = 0x04-4 digits int, no decimal point, eg. 2888 ppm STATUS1 * 8 bits monitor and sensor status information SS0 * b0 \ 00 sensor working fine, SS1 * b1 / 01 sensor failure, 11 sensor aging. Reserved1 Reserved2 Reserved3 Reserved4 Reserved5 Reserved6 * b2 Reserved not been used * b3 eserved not been used * b4 Reserved not been used * b5 Reserved not been used * b6 Reserved not been used * b7 Reserved not been used Section 3. Data value format representation: The floating point data values use IEEE754 32 bits floating point little ending representation. They are: DATA1, DATA2 Section 4. Data transfer mechanism Due to the monitor main chips feature, 4 bytes floating point data and 2 bytes int data send sequence are low byte first, high byte last, such as section 3 data DATA1 and FACTOR. Section 5. RS485 communication port settings: Baud rate: 4800 Data bits: 8 Stop bits: 1 Parity: none Flow control: none Page 14