BC Digital Keypad. User Manual

Similar documents
W3-H Waterproof Keypad/Reader/Controller

W3-M. Metal waterproof standalone access control/reader. User Manual

Waterproof. Keypad/Reader/Controller

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Single Door Standalone Access Control User Manual

CM-110SK Standalone Keypad Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

User Manual. PCKeypad Wireless Keypad

DOLXFD1000B. Waterproof Access Control/Reader

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Fingerprint Access Control F1. User Manual

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

VIDI-AC-2CS Access Controller/ Reader

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

-DTZ001- Stand-Alone Proximity Access Control. User Manual

Digital Keypad Introduction

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

VIS-3200 / VIS-3201 User Manual

Stand-alone Proximity Access Control

User Manual. Split access control with intelligent secured power supply.

RBR-SB-KTZ001 LAR 2. User Manual

Installation and User Manual

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

CC Series metal access control Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

EL-ST100 KEYPAD CONTROLLER

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

HSY-S209 EM Metal waterproof access control system User Manual

Installing Keypad and Backplate

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

Specifications: Features:

CP150B Vandal & Weather Resistant Keypad Security Systems

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

FTK5 PROXIMITY KEYPAD

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

REX F-0-9 Standalone or Access Controller

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

DG Series. Access Control Proximity Readers DG-160 DG-800

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

AS Keypad User Manual

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

Metal Standalone Keypad Access Control S100

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

CM-500 SK 500 USER CODES KEYPAD

PAC2 Dual Door Access Controller

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

Security at Fingertips.

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

HL100 Fingerprint Lock User Manual

TOUCHLOCK compact. Ins-182 Date code:

1. Product Specification

E-Access ANXELL TECHNOLOGY CORPORATION E3AK4 E3AK2. Specifications Voltage (Input): 12 to 24 VDC

Installers & User guide Deadbolt 2S.

ACTsmart2 Product Range Operating and Installation Instructions

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

Wireless Key fob, Key pad & Receiver Range

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

K44 Code lock. Technical manual

CV-945 Stand-Alone Biometric Reader. Installation Instructions

INSTALLATION INSTRUCTIONS 920P EntryCheck TM


Intelligent Security & Fire Ltd

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

212iL Rev. 1.1

ACCESS CONTROL SYSTEM

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

PAC1 Door Access Controller

PAC1 Door Access Controller

MANUAL PIN CODE KEYPAD February 2013

9212i INSTALLATION. Stand-Alone Keypad. Instructions

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Stand-Alone Data Chip System

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

Installers & User guide Smart Mortise.

Installers & User guide Smart Mortise.

TOUCHLOCK compact keypad Stainless Steel

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

Revision Date: 02 Mar 2018

Security Door Controls

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

SK-1011-SQ Digital Access Keypad with 5A Relay Output

GV-RK1352 and GV-R1352 Card Reader

GV-Card Reader. User s Manual

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

KP2000E/EM Series Style Keypad

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

2000 Series e/em Style Keypad Installation and Programming Manual

ECI1. COMPASS display. ECI1-REV For latest update: Electronic Compass Indicator ECS1

Fingerprint Door Lock OPERATOR S MANUAL

Transcription:

BC2200 Digital Keypad User Manual

Name Digital Keypad BC2200 User manual Screw driver Rubber bungs Self tapping screws Diode 1. Packing List Quantity Remarks 1 1 1 4 Φ6mm 28 mm, used for fixing 4 Φ4mm 25 mm, used for fixing 1 1N4004 Please ensure that all the above contents are correct. If any are missing please notify the supplier of the BC2200 2. Description BC2200 is a digital keypad for single door; it is housed in a strong, sturdy and vandal proof zinc alloy electroplated structure. The BC2200 use the American Atmel MCU, can be easily programmed with 200 PIN users, PIN length 4~6 digits. And it has many extra features includes Pulse mode & Toggle mode, Safe mode ect. These features make the BC2200 an ideal choice for door access not only for small shops and domestic household but also commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons. 3. Features > Strong zinc alloy electroplated antivandal structure > Full programming from the keypad > 200 PIN users, PIN length: 4~6 digits > Backlight keypad > One programming relay output,,, > Pulse mode, Toggle mode >, yellow, green LED display the working status > Built in Buzzer > Adjusted door output time, alarm time, door open time > Operating Temperature: 40~60 > Twoyear warranty 4. Specification Operating Voltage 12V DC User Capacity 200 Keypad 12 keys, 3 x 4 digits Active Current <80mA Idle Current <15mA Lock Output Load Max 3A

Output Load Max 3A Operating Temperature 40~60 Adjustable Door Relay time 1 ~ 99 seconds Adjustable Time 0 ~ 3 minutes Wiring Connections Electric Lock, Exit Button, DOTL, External Dimensions L128 x W82 x H28 mm Net Weight 300 g Gross Weight 450 g 5. Installation > Remove the back cover from the keypad using the supplied security screwdriver > Drill 4 holes on the wall for the screws and 1 hole for the cable > Fix the back cover firmly on the wall with 4 flat head screws > Thread the cable through the cable hole > Attach the keypad to the back cover 12V D_IN ALARM J3 K13 6. Wiring Color Function Description Orange Purple Brown Yellow Grey D_In Relay Relay Relay Door Contact 12V power input Request to Exit Button Negative

Connection Diagram Special Power Supply: Special Power Supply PUSH Electric Bolt Green Door Button Yellow Door Contact Brown Grey D_IN ALARM BC2200 Here are some lock wirings based on different locks Special Power Supply EM lock Special Power Supply Electric Controlling Lock Common Power Supply: Power In4004 Electric Bolt Green Door Button Yellow Door Contact Brown Grey D_IN ALARM BC2200 Here are some lock wirings based on different locks EM lock In4004 Green BC2200 Electric Controlling Lock In4004 BC2200

7. Relay Operation (Pulse mode and Toggle mode) Relay can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for arming/disarming alarms, switching lights, machines.etc) Everything time read a valid tag/card or input a valid PIN in Pulse Mode, the relay will operate, for the preset relay pulse time. Everything time read a valid tag/card or input a valid PIN in Toggle Mode, the relay changes state, which will not turn back until read card or input PIN again. 8. Reset to Factory Default To reset to factory default, power off, press, hold it and power on, release it until hear two beeps, and the LED will turn into red, means reset to factory default successfully. Remarks: Reset to factory default, the user's information is still retained. 9. Sound and Light Indication Operation status Power on Stand by Press keypad Operation successful Operation failed Enter into programming mode In the programming mode Exit from the programming mode Open the door Light Green Light Buzzer 3 s Long Ring 10.1 User Settings 10. Detailed Programming Guide To enter the programming mode * Master code # 9999 is the default factory master code To exit from the programming mode Note that to undertake the following programming the master user must be logged in To change the master code To add a PIN user 0 New code # New code # The master code is any 48 digits 1 User ID number # PIN # The ID number is any number between 0 ~ 199. The PIN is any 4~6 digits between 0000 ~ 999999. Users can be added continuously without exiting from programming mode as follows: 1 User ID number 1 # PIN # User ID number 2 # PIN #

To delete a PIN user To change the PIN of a PIN user (Note: This step must be done out of programming mode) To delete ALL users 10.2 Relay Setting (Pulse mode, Toggle mode) Pulse mode Door relay time setting Toggle mode 10.3 Door,, LED Settings output time To set the alarm output time (03 minutes) Factory default is 1 minute 2 User ID number # Users can be deleted continuously without exiting programming mode * User ID number # Old PIN # New PIN # New PIN # 2 0000 # Note that this is a dangerous option so use with care To unlock the door Enter the PIN then press # 4 1~99 # 4 0 # 5 0~3 # (Factory default setting: 5s) Door Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or builtin magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically. Door Forced Open warning. When used with an optional magnetic contact or builtin magnetic contact of the lock, if the door is forced open, or if the door is opened after 120 seconds of the electromechanical lock not closed properly, the inside buzzer and alarm output will both operate. To disable door open detection (Factory default setting) 6 0 # To enable door open detection 6 1 # Keypad Lockout & Output Options. If there are 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or the alarm will operate, depending on the option selected below. Normal status: No keypad lockout or alarm 7 0 # (Factory default setting) Keypad Lockout 7 1 # Output 7 2 # LED light The red LED light can be set on or off. OFF 8 0 # Normal status: On 8 1 # (Factory default setting) To remove the alarm To reset the Door Forced Open warning Input Valid PIN or Master Code # To reset the Door Open Too Long Close the door or Input Valid PIN or warning Master Code #