W3-H Waterproof Keypad/Reader/Controller

Similar documents
Waterproof. Keypad/Reader/Controller

W3-M. Metal waterproof standalone access control/reader. User Manual

BC Digital Keypad. User Manual

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

Single Door Standalone Access Control User Manual

DOLXFD1000B. Waterproof Access Control/Reader

User Manual. PCKeypad Wireless Keypad

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

VIDI-AC-2CS Access Controller/ Reader

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

-DTZ001- Stand-Alone Proximity Access Control. User Manual

Stand-alone Proximity Access Control

Fingerprint Access Control F1. User Manual

User Manual. Split access control with intelligent secured power supply.

RBR-SB-KTZ001 LAR 2. User Manual

VIS-3200 / VIS-3201 User Manual

Installation and User Manual

CC Series metal access control Manual

Digital Keypad Introduction

ACCESS CONTROL SYSTEM

DG-800 Stand-Alone Proximity Reader Instruction Manual

EL-ST100 KEYPAD CONTROLLER

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Metal Standalone Keypad Access Control S100

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

HSY-S209 EM Metal waterproof access control system User Manual

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

REX F-0-9 Standalone or Access Controller

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

ACTsmart2 Product Range Operating and Installation Instructions

CV-945 Stand-Alone Biometric Reader. Installation Instructions

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

KP2000E/EM Series Style Keypad

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

_ Access control SISTEMAS DE SEGURIDAD

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

CP150B Vandal & Weather Resistant Keypad Security Systems

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Specifications: Features:

RFID PRODUCT AND SYSTEM

1. Product Specification

2000 Series e/em Style Keypad Installation and Programming Manual

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Revision Date: 02 Mar 2018

GV-Card Reader. User s Manual

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Installing Keypad and Backplate

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

Two Door Controller GEN-045

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

AYC-F/G/M60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

CM-500 SK 500 USER CODES KEYPAD

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Proximity Card and Pin Reader Installation Manual

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

GV-AS Controller. Installation Guide

AS Keypad User Manual

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

B100-SA Standalone Biometric Reader

AYC-E/Q/T60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual

7612 Programming Instructions

IBA-7612 Programming Instructions

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

EX8. User Manual. Ver 1.0

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

Access control panel U-Prox IC E (Elevator control)

DG Series. Access Control Proximity Readers DG-160 DG-800

GV-RK1352 and GV-R1352 Card Reader

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

K44 Code lock. Technical manual

PAC2 Dual Door Access Controller

FTK5 PROXIMITY KEYPAD

MULTI-DISCIPLINE READERS. ImproX Multi-discipline Readers INSTALLATION MANUAL SPECIFICATIONS MODEL NUMBER: MDR GB-XX MDK GB-XX

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

Webpass IP Reader Installation Guide

AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange

PAC1 Door Access Controller

PAC1 Door Access Controller

Transcription:

W3-H Waterproof Keypad/Reader/Controller User Manual

1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark 6*27mm, used for fixing 4*28mm, used for fixing In4004 Manager Add Card & Manager Delete Card Please ensure that all the above contents are correct. If any are missing please notify the supplier of the W3-H. 2. Description The W3-H is a single door multifunction access control with HID card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed in a strong, sturdy and vandal proof zinc alloy electroplated case. The electronics are fully potted so the W3-H is waterproof and conforms to IP65. The W3-H supports up to 2,000 users in either a Card, 4~8 digits PIN, or a Card + PIN option and additional 10 groups Duress PIN/Card. The builtin card reader supports HID 125KHz frequency cards/tags. The W3-H has many extra features including Duress PIN/card, block enrollment, Wiegand 26~37 bits interface, and backlight keypad etc. These features make W3-H an ideal choice for door access not only for small shops and do mestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons. 3. Features > Waterproof, conforms to IP65 > Strong zinc alloy electroplated anti-vandal case > Full programming from the keypad > One programmable relay output,,, > 2,000 users, supports Card, PIN or Card, Card + PIN > 10 groups Duress PIN/Card > Card interface: HID 125KHz Card > Can be used as a standalone keypad, PIN length 4~8 digits > Pulse mode, Toggle mode > Wiegand 26~37 input & output > Adjustable door output time, alarm time, door open time > Card block enrollment > With Manager Cards for adding or deleting card user easily > Backlight keypad > Built in light dependent resistor (LDR) for anti tamper > Built in buzzer > Red, yellow and green LED display the working status > 12~24V DC/12~18V AC > Two-year warranty 4. Installation > Remove the back cover from the keypad using the supplied security screwdriver > Drill 4 holes on the wall for the screws and 1 hole for the cable > Fix the back cover firmly on the wall with 4 flat head screws > Thread the cable through the cable hole > Attach the keypad to the back cover

6. Wiring J1 W3-H Colour Green White Grey Yellow Brown Red Black Blue Purple Orange Pink Function Alarm - 12~24V DC/12~18V AC 12~24V DC/12~18V AC Description Wiegand Output Wiegand Output Alarm Negative Request to Exit Button Door Contact 12~24V DC/12~18V AC Regulated Power Input 12~24V DC/12~18V AC Regulated Power Input Relay Relay Relay W3-H Negative Anti-demolition alarm J1 Connection Giagram Operating Voltage User Capacity Keypad Card Type Card Reading Distance Active Current Idle Current Lock Output Load Alarm Output Load Operating Temperature Operating Humidity Environment Adjustable Door Relay Time Adjustable Alarm Time Wiegand Interface Wiring Connections Dimensions Net Weight Gross Weight PCB Connect Diagram 5. Specifications 12~24V DC/1 2~18V AC 2,000 (Additional10 groups Duress PIN/Card) 12 keys: 3 X 4 digits HID 125KHz card 3~6 cm 65mA 35mA Max 2A Max 20A -20~50 10%~90% RH Conforms to IP65 1~99 seconds 0~3 minutes Wiegand 26~37 input & output Electric Lock, Exit Button, DOTL, External Alarm L128 X W82 X H28mm 600 g 700 g W3-H Pink Green White Grey Yellow Brown Red Black Blue Purple Orange Wiegand Wiegand Door detecting switch Exit button + - Power DC 12V/3A +12V + - - + Fail-Safe lock Fail-Secure lock Alarm - Special Power Supply Alarm

Pink Green White Grey Yellow Brown Red Black Blue Purple Orange Door detecting switch Exit button Power + Electric bolt: Electric strike: Power + Alarm - In4004 + - Power - Alarm 12~24V DC/ 12~18V AC/3A + Lock 9. Relay Operation (Pulse mode and Toggle mode) The relay on board can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for arming/disarming alarms, switching lights, machines.etc) Every time a valid tag/card or PIN is read/input in Pulse Mode, the relay will operate, for the pre-set relay pulse time. Every time a valid tag/card or PIN is read/input in Toggle Mode, the relay changes state, which will not turn back until read card or input PIN again. W3-H Common Power Supply Notes: Connect the negative pole of the lock to is for Fail safe lock. Connect the negative pole of the lock to is for Fail-secure lock. 7. Anti Tamper Alarm The W3-H uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the cover then the tamper alarm will operate. 10. Sound and Light Indication Operation Status Power on Stand by Press keypad Red Light Green Light Yellow Light Buzzer Operation successful Operation failed Enter into programming mode 3 In the programming mode Exit from the programming mode Open the door Alarm Alarm 8. To Reset to Factory Default To reset to factory default, power off, press, * hold it and power on, release it until hear two beeps and the LED shines in orange, then read any two HID cards, the LED will turn in red, means reset to factory default setting successfully. Of the two HID cards read, the first one is Manager Add Card, the second one is Manager Delete Card. Remarks: Reset to factory default, the user's information is still retained.

11.1 User Settings 11. W3-H Detailed Programming Guide To enter the programming mode To exit from the programming mode * Master code # 888888 is the default factory master code Note that to undertake the following programming the master user must be logged in * To change the master code Setting the working mode: set valid card only users set valid card and PIN users set valid card or PIN users 0 New code # New code # The master code is any 6 digits 3 0 # Entry by Card only 3 1 # Entry by Card and PIN together 3 2 # Entry by either Card or PIN (default) To set a user in either card or PIN mode ( 3 2 # ) (Default setting) To add a PIN user To delete a PIN user To change the PIN of a PIN user (This step must be done out of programming mode) To add a card user (Method 1)This is a fastest way to add cards using ID number auto generation To add a card user (Method 2)This is the optional way to add cards using User ID Allocation. In this method a User ID is allocatedto a card. Only one user ID can be allocated to a single card 1 User ID number # PIN # The ID number is any number between 1~ 2000. The PIN is any 4~8 digits between 0000 ~99999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting from programming mode as follows: 1 User ID No 1 # PIN # User ID No 2 # PIN # 2 User ID number # Users can be deleted continuously without exiting programming mode * ID number # Old PIN # New PIN # New PIN # 1 Read Card # Cards can be added continuously without exitingprogramming mode 1 ID number # Card #

To add a card user (Method 3) Add a series cards users - Block Enrollment To delete card user by card(note users can be deleted continuously without exiting from programming mode) To delete a card user by user ID( This option can be used when a user has lost their card) To delete a card user by card number (Users can be deleted continuously without exiting from programming mode) To set a card and PIN user in card and PIN mode ( 3 1 # ) To Add a card and PIN user (The PIN is any 4~8 digits between 0000 ~ 99999999 with the exception of 1234 which is reserved) To change a PIN in card and PIN mode (Method 1) Note that this is done outside programming mode so the user can undertake this themselves To change a PIN in card and PIN mode (Method 2) Note that this is done out side programming mode so the user can undertake this themselves To delete a Card and PIN user just delete the card To set a card user in card mode ( 3 0 # ) 5 ID number # The 1st Card number # Card quantity # Note that cards must be consecutive, and card quantity is between 1~2000 Maximum 2,000 cards can be enrolled at a stretch within 2 minutes 2 Read Card # 2 User ID # 2 Card number # Add the card as for a card user Press * to exit from the programming mode Then allocate the card a PIN as follows: * Read Card 1234 # PIN # PIN # * Read Card Old PIN # New PIN # New PIN # * ID number # Old PIN # New PIN # New PIN # 2 Read card # or 2 User ID # To Add and Delete a card user To delete All users To delete ALL users Note that this is a dangerous option so use with care The operating is the same as adding and deleting a card user in 3 2 # 2 0000 # To set card users by Manager card To add Card User by Manager Add Card To delete Card User by Manager Delete Card Manager add card Read User card Manager add card Cards can be added continuously Manager delete card Read User Card Manager delete card Cards can be deleted continuously

To unlock the door For a PIN user Enter the PIN then press # For a card user Read card For a card and PIN user Read card then enter PIN # 11.2 Relay Setting (Pulse mode,toggle mode) Pulse mode (Factory default) Pulse mode (Door relay time setting) Toggle mode 4 1~99 # The door relay time is between 1~99 seconds, the factory default setting is 5 seconds. Toggle mode 4 0 # 11.3 Door Detection, Alarm, Sound and Light Settings Door Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically. Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is open by force, or if the door is opened after 120 seconds of the electro-mechanical lock not closed properly, the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0~3 minutes with the default being 1 minute. To disable door open detection To enable door open detection Alarm output time To set the alarm output time (0~3 minutes). Factory default is 1 minute 6 0 # (Factory default ) 6 1 # 9 0~3 # Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or the alarm will operate, depending on the option selected below.

Normal status: No keypad lockout or alarm Keypad Lockout Alarm Output Light and Sound Setting To set keypad backlight To set LED To set keypad tone 7 0 # (Factory default ) 7 1 # 7 2 # 7 4 # To disable keypad backlight 7 5 # To enable keypad backlight(factory default) 7 6 # To disable the red LED 7 7 # To enable the red LED(Factory default) 7 8 # To disable the keypad tone 7 9 # To enable the keypad tone(factory default) To remove the alarm To remove the Door Forced Open warning Read Valid Card or Master Code # To remove the Door Open Too Long warning Close the door or Read Valid Card or Master Code # 12. Duress User Settings There are 10 groups Duress PIN/card available. When input Duress PIN/card,the door will open, at the same time,the output alarm operates.(note:all the setting are under programming mode) To set Duress PIN user To add a PIN user To delete a PIN user To set Duress card user To add a card user 8 User ID number # PIN # (The ID number is any number between 2001~2010) 2 User ID number # 8 User ID number # card # (The ID number is any number between 2001~2010) To delete a card user 2 User ID number # Note: 1 User ID number must be any 4digits between 2001~ 2010 2 Duress PIN/card must be unique, should be distinguished from common PIN and card (When the Duress PIN/card is the same with common PIN and card, they will become invalid in Duress, and worked as common user function)

13. Wiegand Mode Setting W3-H supports Wiegand 26~37, both input and output. It can be used as a reader or controller. To set Wiegand format: 9 26~37 # (Default setting: Wiegand 26) 14.1 W3-H operating as a Wiegand Output Reader 14. Interconnecting Two Devices In this mode the W3-H supports a Wiegand 26~37 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26~37 bit input. See figure 1. Pink Green White Grey V+ Yellow Brown Red Power V+ Controller Black Blue Purple Orange Transmission Format: Figure 1 W3-H 1: Keypad Transmission The Reader will transmit the PIN data when it receives the last key (#) press after PIN code. Format: PIN Code ( any 4~8 digits between 0000~99999999) Example: PIN code:111111 Press 111111 #, then the output format will be: 0000111111 (Note: if press an invalid PIN (any 4~8 digits), the data will be also transmitted.)

2: Proximity Card Transmission The Reader will transmit the card data when it reads the Card. Format: Card Number (Note: No matter the card is valid or invalid, the data will be transmitted) 14.2 W3-H operating as a Controller In this mode the W3-H supports a Wiegand 26~37 bit input so an external Wiegand device with a 26~37 bit output can be connected to the Wiegand input terminals on the W3-H. Either an ID card reader (125KHz) or an IC card reader (13.56MHz) can be connected to the W3-H. Cards are required to be added at the external reader, except where an external HID reader is used, in this case cards can be added at either reader or controller. See figure 2. Pink Green White Grey Yellow Brown Red Black Blue Purple Orange Exit button Door detecting switch Wiegand reader V+ Special Power Supply DC 12V/3A +12V + - - + Fail-Safe lock Fail-Secure lock + - Alarm W3-H Figure 2

To enter the programming mode W3-H Quick Reference Programming Guide To exit from the programming mode * Note that to undertake the following programming the master user must be logged in * Master code # 888888 is the default factory master code To change the master code To add a PIN user To add a Card user To delete a PIN or a Card user To unlock the door To unlock the door for a PIN user To unlock the door for a card user 0 New code # New code # The master code can be 6 digits long 1 User ID number # PIN # The ID number is any number between 1~2,000. The PIN is any 4~8 digits between 0000 ~ 99999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting programming mode 1 Read Card # Cards can be added continuously without exiting from programming mode 2 User ID number # for a PIN user or 2 Read Card # for a card user Enter the PIN then press # Present the card