-DTZ001- Stand-Alone Proximity Access Control. User Manual

Similar documents
Stand-alone Proximity Access Control

RBR-SB-KTZ001 LAR 2. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

VIDI-AC-2CS Access Controller/ Reader

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

DOLXFD1000B. Waterproof Access Control/Reader

Waterproof. Keypad/Reader/Controller

Fingerprint Access Control F1. User Manual

Single Door Standalone Access Control User Manual

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

VIS-3200 / VIS-3201 User Manual

W3-H Waterproof Keypad/Reader/Controller

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

W3-M. Metal waterproof standalone access control/reader. User Manual

BC Digital Keypad. User Manual

User Manual. Split access control with intelligent secured power supply.

Digital Keypad Introduction

User Manual. PCKeypad Wireless Keypad

DG-800 Stand-Alone Proximity Reader Instruction Manual

CC Series metal access control Manual

Installation and User Manual

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

ACCESS CONTROL SYSTEM

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

EL-ST100 KEYPAD CONTROLLER

1. Product Specification

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Metal Standalone Keypad Access Control S100

HSY-S209 EM Metal waterproof access control system User Manual

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

CV-945 Stand-Alone Biometric Reader. Installation Instructions

REX F-0-9 Standalone or Access Controller

Specifications: Features:

9212i INSTALLATION. Stand-Alone Keypad. Instructions

CM-500 SK 500 USER CODES KEYPAD

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

AS Keypad User Manual

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

RFID/Digital Access Control Keypad

Operation and Maintenance Manual

Installing Keypad and Backplate

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

PR602LCD v1.0 Installer Manual Rev. A

CP150B Vandal & Weather Resistant Keypad Security Systems

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

7612 Programming Instructions

IBA-7612 Programming Instructions

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Two Door Controller GEN-045

INSTALLATION INSTRUCTIONS. lighted and acoustic feedback. capacity to manage up to 200 users. does not require a remote unit. programmable from PC

ACTsmart2 Product Range Operating and Installation Instructions

GV-AS Controller. Installation Guide

Stand-Alone Data Chip System

212iL Rev. 1.1

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

Fingerprint Identification Proximity Reader. Quick Installation Guide

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

PXL-250 Tiger Controller

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Wireless Key fob, Key pad & Receiver Range

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

UNIVERSAL EXPANDER FOR CARD / CHIP READERS INT-R. 1. Features. 2. Installation and start-up

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

UC-2000 Installation Manual Unicorn Computers Technology Limited

TOUCHLOCK compact. Ins-182 Date code:

_ Access control SISTEMAS DE SEGURIDAD

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

GV-AS/EV Controller. User s Manual

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

FTK5 PROXIMITY KEYPAD

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

DG Series. Access Control Proximity Readers DG-160 DG-800

SK-1011-SQ Digital Access Keypad with 5A Relay Output

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

Wiring Instructions v3

Installation guide for PR302 v2.0 Rev. E

INSTALLATION INSTRUCTIONS. lighted and acoustic feedback. capacity to manage up to 200 users. does not require a remote unit. backlit touch keypad

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

Installation & Calibration Manual

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

Fingerprint Door Lock OPERATOR S MANUAL

Connecting a Cisco Reader Module

2000 Series e/em Style Keypad Installation and Programming Manual

GV-EL124S Electric Strike

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Transcription:

-DTZ001- Stand-Alone Proximity Access Control User Manual

INTRODUCTION DTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users, read both EM & HID card. It uses Atmel microcontroller assures maximum performance in any environment, and the low-power circuit makes its service life prolonged. The product unique feature is simple in design, easy to operation, and high reliability. Features Waterproof, confirm to IP66 Read 125KHz EM & HID card One programmable relay operation Pulse mode, Latch mode Remote infrared programmer 2000 users Card block enrolment Tri-colour LED status display Built in light dependent resistor (LDR) for anti tamper Buzzer for audible or silent mode Low temperature resistance(-40) Specifications: User Capacity Card Operating Voltage Idle Current Proximity Card Reader Radio Technology Read Range Wiring Connections Relay Adjustable Relay Output Time Lock Output Load Environment Operating Temperature Operating Humidity Physical Colour Dimensions Unit Weight Shipping Weight 2000 EM card and HID card 12~24V DC 40mA EM&HID 125KHz Proximity Card 3-10cm Relay Output, Exit Button One (NO, NC, Common) 1-99 Seconds (5 seconds default) 2 Amp Maximum Meets IP66-40 ~60 20%RH-98%RH ABS Shell Black L: 102* W: 48 * H:20mm 150g 250g Carton Inventory DTZ Reader: 1 Infrared Remote Control: 1 Diode IN4004 (For relay circuit protection): 1

Self Tapping Screws 2 x Φ3*25mm Rubber Bungs2 Screw Driver 1 INSTALLATION Remove the back cover from the unit Drill 2 holes(a,c) on the wall for the screws and one hole for the cable Knock the supplied rubber bungs to the screw holes(a,c) Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole(b) Attach the unit to the back cover. Wiring Wire Insulation Colour Function Notes Red Power + 12~24 Votes DC Regulated Power Input Black GND Ground White NO Normally Open Relay Output Brown COM Common Connection for Relay Output Green NC Normally closed Relay Output Yellow OPEN Request to Exit input(rex)

Connection Diagram Common power supply: Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1N4004 is included in the packing) Access Control Power Supply:

PROGRAMMING Programming will vary depending on access confirguratio. Follow the instructions according to your access configuration. General Programming Information Remote Control: Please use the Infrared Remote Control to program the Reader. User ID number:assign a user ID to the access card in order to track it. The user ID number can be any number from 1~2000. IMPTANT: User IDs do not have to be proceeded with any leading zeros. Recording of User ID is crical. Modifications to the user require the User ID be available. Proximity Card: Any 125KHz industry standard 26 bit EM and HID Proximity card or Tag. Enter and Exit Program mode Enter Program Mode (Master Code) # Factory default is 123456 Exit Program Mode * Set Master Code 1. Enter Program Mode (Master Code) # 2. Update Master Code 0New Master Code#Repeat New Master Code# 3. Exit Program Mode * Add User Cards 1. Enter Program Mode (Master Code) # 2. Add Card: Using Auto ID 1 (Read Card) # (Allows DTZ001 to assign Card to next Repeat Step 2 for additional user cards available User ID number) 2. Add Card: Select Specific ID 1 (User ID) # (Read Card) # (Allows manager to define a specific User The user ID is any number from 1-2000. ID to associate the card to) 2. Add Card: by Card Number 1 (Input 8/10 digits Card number) # 2. Add Card: Block Learn 1 ( User ID number) # (Card quantity) (Allows manager to add up to 2000 cards #(The first card number) # to the Reader in a single step.) Takes 3 Cards number must be consecutive; minutes to program. Card quantity = number of card to be enrolled. 3. Exit Delete User Cards 1. Enter Program Mode (Master Code) #

2. Delete Card: By read card 2. Delete Card: Select Specific ID 2. Delete Card: by Card Number 2 (Read Card) # Repeat Step 2 for additional user cards 2 (User ID) # The user ID is any number from 1-2000. 2 (Input 8/10 digits Card number) # Set Relay Configuration The relay configuration sets the behaviour of the output relay on activation. 1. Enter Program Mode (Master Code) # 2. Pulse Mode 3 (1-99) # The relay time is 1-99 seconds(default is 5 seconds) 3 0 # 2. Latch Mode Sets the relay to ON/OFF Latch mode 3. Exit Set Strike-out Alarm The strike-our alarm will engage after 10 failed card attempts. Factory is OFF. The strike-our alarm ca be set to deny access for 30 minutes after engaging or it can be set disengage only after entering a valid card or Master code. 1. Enter Program Mode (Master Code) # 2. Strike-Out OFF 4 0 # (factory default) 2. Strike-Out ON 4 1 # Access will be denied for 10 minutes 2. Strike-Out ON (Alarm) 4 2 # Set alarm time 5 (0 ~ 30) #, factory default is 1 minute Enter Master code # or valid user card to silence 3. Exit Set Audible and Visual Response 1. Enter Program Mode (Master Code) # 2. Control LED 2. Control Sounds OFF = 6 1 # OFF = 6 3 # ON = 6 2 # ON = 6 4 # (Factory defaults are ON) 3. Exit Others

Users Operation: Open the door: Read the valiad user card, the door will open. Remove Alarm: Read valid user card, or Input Master code # Reset to Factory Default: To reset to factory default, power off, press Exit door button, hold it and power on, release it after hear two beeps, the LED light will turn into yellow, after 10 seconds, it will turn into red after one beep, mean reset to factory default successfully. Remarks: Reset to factory default, the user s information is still retained. Erase all Cards This will delete ALL User data. 1, Enter Program Mode by press: *(Master Code) #. 2, Press 2 and Master code again 3, Exit: * All configuration data is retained. Sound and Light indication Operation Status LED Buzzer Stand by Red light bright - Enter into programming mode Red light shines One beep In the programming mode Yellow light bright One beep Operation error - Three beeps Exit from the programming mode Red light bright One beep Open lock Green light bright One beep Alarm Red light Shines quickly Beeps DTZ001- Simplified Instruction Function description Choose from the relevant functions below and input Enter the programming mode *- 123456 - # then you can do the programming (123456 is the default factory master code) change the master code 0 new code - # - repeat the new code - # (code: 6 digits) Add card user 1- Read Card - # (can add Cards continuously) Delete card user 2 Read Card -# (can delete Cards continuously) Exit from the programming mode * How do release the door Card User Read card