BLR2 A PLUS MKII User Manual Version1.0

Similar documents
BLR2 LITE MKII User Manual Version1.1

BLS2 LITE MKII User Manual Version1.0

WorkCAD3 Configurator User Manual - Version1.2

WorkCAD3 Configurator User Manual - Version1.1

Pro Audio Streamers. IP Streamers. June catalogue. Manufacturers of audio & video products for radio & TV broadcasters

Installation Guide. Stereo / Mono Audio Power Amplifier - 60 Watts AT-GAIN-60. Package Contents

IP-ZCM. PoE+ IP to Analog Gateway (Zone Controller)

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

AMP Watt Audio Amplifier with RS-232 and IR Control. User s Manual CUSTOMER SUPPORT INFORMATION

QUICKSTART GUIDE ENGLISH ( 3 9 ) MANUAL DE INICIO RÁPIDO ESPAÑOL ( ) GUIDE D UTILISATION RAPIDE FRANÇAIS ( )

MX X 250W AMPLIFIED MASTER UNIT

Voice Alarm System VX-3000 Series

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

EEG CC1260 icap Interface Card

Voice Alarm System VX-3000 Series

MU 9186R MASTER UNIT WITH ROUTER

Overview. Features. Technical Data Sheet 1 / 5. Signal Processor MRX7-D

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Specifications MLC 226 Series

ZCM-V2+T. PoE+ IP to Analog Gateway (Zone Controller) Used In the ZC1PRO+T and ZC2PRO+T

Embedded Automation, Inc. Suite #104, th Street Surrey, BC V3W 1H8 Phone: (604) Fax: (604)

EN54-16 COMPLIANT HARDWARE BYPASS MICROPHONE PORTS 12 ANALOGUE AUDIO INPUTS 12 GPIO INPUTS & 12 OUTPUTS 12 ANALOGUE AUDIO OUTPUTS

Voice Alarm System VX-3000 Series

IP Speaker System. Users Guide

AUDIO MANAGEMENT SYSTEM

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

AMP20. User Manual.

8180 LOUD RINGER USER GUIDE

Stereo / Mono. Audio Power Amplifier W. Introduction. Applications

mp3 bbox 12-24V INSTALLATION GUIDE 4.0 REALITY SYS bbox 12-24V V4.0 Installation 1

Install AV Catalog. Effective Q Attero Tech, LLC.

Quick Installation Guide

Marshall Electronics. AR-AM4-BG Analog Audio Monitor. Operating Instructions

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

USER MANUAL. RC-76R/RC-78R Room Controllers MODEL: P/N: Rev 2

N-8000 SERIES IP INTERCOM SYSTEM

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

IP-DM. IP Wall Mount LCD with Microphone

USER MANUAL. RC-74DL Master Room Controller MODEL: P/N: Rev 4

SoundwebTM. Installation Guide

Install AV Catalog. Effective Q Attero Tech, LLC.

User manual English version

USER MANUAL V/100V Power Amplifier MODEL: P/N: Rev 4

Cisco D9034-S Encoder

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

Marshall Electronics. AR-AM1 Analog Audio Monitor. Operating Instructions

Marshall Electronics. Operating Instructions. Warranty. AR-AM1 Analog Audio Monitor

User Guide. (English)

P100 Wireless Player.

Specifications VN-Matrix 250 Series

E1/10&100Base-T Bridge (VLAN)

LTD East 5th Street Superior, WI USA tel: fax:

Click-A-Tune. User Manual

TeamConnect SL TeamConnect CU1, Central Unit, SL TeamConnect CB1, Combox

User Manual Controller. Automation and Router Control.

IN-E1004 Encoder Hardware Manual

You are now the owner of the world s most high performance audio system.

IP PUBLIC ADDRESS INTERFACE

MPS10 - MPS50. Modular Paging and Emergency Microphones

Q-SYS NV-32-H Preliminary Specifications Q-SYS NV-32-H. Features. Native integration and control for the Q-SYS Ecosystem

PRELIMINARY DATA SHEET AM 1 AUTOMIXER SHIPS APRIL 2010

MPS01. Paging and Emergency Microphone

AUD-220 Installation Guide

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-74DL Master Room Controller. P/N: Rev 5

Industrial PoE Plus Outdoor IR IP Camera ICA-2250VT

INSTRUCTIONS FOR USE Pro-Ject Pre Box RS digital

USER MANUAL. SL-10 Master Room Controller MODEL: P/N: Rev 4

ACCESS LINK DETAILED SPECIFICATIONS

VPort P16-2MR Series Quick Installation Guide

Professional Audio Conferencing Products - CONVERGE Pro 2 Series

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

INSTALLATION INSTRUCTIONS. Table of Contents

Install AV Catalog. Effective Q Attero Tech, LLC.

1 master and 8 independent stereo subgroup Flexible architecture including a modular control surface, outputs

APC100. User Manual.

You are now the owner of the world s most high performance audio system.

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

SMC 7.1. User Manual. Surround Monitor Controller SMC 7.1. This User Manual is optimized for Acrobat Reader.

Azimut. Minimalist design, maximum connectivity

USER MANUAL RC-76M/RC-712M MODEL: P/N: Rev 3

BLUE LOG XM / XC. Quick Start Guide. Version

HP4 headphone amplifier. user manual

SNC-DF40P High Resolution Minidome Color Camera with 10/100 Base T Ethernet

Azimut. Minimalist design, maximum connectivity

Network audio encoder / decoder with I/O for professional and broadcast applications

FreeSpace Amplifiers. Premium commercial amplifiers designed to enhance audio installations using Bose FreeSpace loudspeakers.

6 Controlling the Technomad Encoder

Ares. Modular Audiophile System. by Thrax Audio. Operating Manual. Manual issued 15/03/2018 CAUTION

2M Outdoor Motorized Bullet Camera

IP-HVP. PoE+ Vandal and Weather Resistant Wall Mount IP Speaker

Marshall Electronics. Operating Instructions. Warranty. AR-AM4 Analog Audio Monitor

Specifications PVS 200, PVS 300, PVS 400 Systems

IP Audiocast Terminal. User Manual V1.06

Audio Interface. User s Manual 14HP. Eurorack Synthesizer Modules

VS-88UT All in One Presentation System with 8x8 4K60 4:2:0 HDMI/HDBaseT 2.0 Matrix Switching, Master Room Controller, PoE & Power Amplifier

4K/UHD Five-Input Universal Switcher with Wireless Presentation Link

ex 800A Series ematrix System

TCM-1 Beamtracking Ceiling Microphone TCM-1A Beamtracking Ceiling Microphone with Amplifier TCM-1EX Beamtracking Expansion Ceiling Microphone

Transcription:

User Manual Version1.0

SAFETY INSTRUCTIONS 1. Read this manual carefully. 2. Follow all instructions and warnings. 3. Only use accessories specified by WORK PRO. 4. Follow the safety instructions of your country. 5. Be careful with sound levels. SYMBOLS The following symbols are used in this document: This symbol indicates a potential risk of harm to a person or damage to the product. You can also notify the user of the instructions that must be followed strictly to ensure the installation or safe operation of the product. This symbol notifies the user about the instructions that must be followed strictly to ensure the correct installation or operation of the product. This symbol notifies the user about additional information or optional instructions. WELCOME TO WORK PRO Thank you for choosing the WORK PRO BLR2 A PLUS MKII system. This document contains essential information on the use of the system. Read this document carefully to become familiar with the system. Please check the WORK PRO website regularly to download the latest version of the document and software updates: https://www.workpro.es/ BLUELINE DIGITAL MKII SERIES www.workpro.es 1

CONTENT 1. INTRODUCTION... 3 2. Components of the BlueLine Digital MKII System... 4 3. RECEIVERS... 4 Audio extracting methods... 5 3.1.1. DUAL... 5 3.1.2. SINGLE... 5 3.1.3. MONO... 6 3.1.4. INVERT OUT... 6 4. BLR2 A PLUS MKII... 7 Features... 8 Device description... 9 4.2.1. Display... 9 4.2.2. Analog audio output... 11 4.2.3. GPIOs... 12 4.2.4. LAN port... 12 4.2.5. Control... 12 4.2.6. Main supply input... 12 4.2.7. Amplified audio output... 13 Device setup... 14 4.3.1. Setup through WorkCAD3 Configurator... 14 Accessories... 16 BLUELINE DIGITAL MKII SERIES www.workpro.es 2

1. INTRODUCTION The devices of the BlueLine Digital MKII series allow the streaming of audio over IP through Ethernet, complying with the TCP / IP protocol stack. Using the BlueLine Digital MKII system it is possible to perform from a simple point-to-point audio transmission to a complex multichannel system with alarm control and management. BlueLine Digital MKII can make use of the existing physical network infrastructure in the installation, due to its low bandwidth consumption. On the other hand, it is compatible with commonly used low or high impedance amplification systems. Thanks to the modular design of the system, BlueLine Digital MKII adapts perfectly to the features of each installation, being able to expand the system in the future if the characteristics of the installation require it. Features: Management of audio strteamers and receivers. Different types of coding (PCM, MP3). Different audio extraction modes (Dual, Single, Mono). Control by OSC commands. Control by GPIO. Complement with the family of Light Mouse devices. Real-time system monitoring. Configuration by software. External power supply or PoE. BLUELINE DIGITAL MKII SERIES www.workpro.es 3

2. Components of the BlueLine Digital MKII System In this chapter you will find information about the different devices that make up the BlueLine Digital MKII system. The BlueLine Digital MKII system has four kinds of devices: BLS2 LITE MKII One stereo channel sender STREAMERS BLS2 SD MKII One stereo channel sender with SD player BLR2 LITE MKII One stereo channel receiver BLR2 MKII One stereo channel receiver with 2xGPIs/2xGPOs RECEIVERS One stereo channel receiver with BLR2 A plus MKII 2xGPIs/2xGPOs and low impedance amplifier PAGING SPS 8 Paging station BLC 1 Wallmount controller for local receiver WALLMOUNT WNC 1 Wallmount controller through the network CONTROLLERS WAC 7 Customizable wallmount controller Note: The BlueLine Digital MKII series is compatible with the previous series of devices, so you can include devices of both series in your installation. 3. RECEIVERS The BlueLine MKII receivers are devices that are responsible for extracting one stereo audio channel from the network. There are three types of receivers: BLR2 LITE MKII: Receiver of one stereo channel. BLR2 MKII: Receiver of one stereo channel with 2GPIs / 2GPOs. BLR2 A PLUS MKII: Receiver of one stereo channel with amplification module and 2xGPIs / 2xGPOs. BlueLine receivers do not consume bandwidth by audio transmission. Its consumption is associated with UDP / OSC state packets and OSC control packets. This consumption will be disregarded, since it is minimal and it will depends on each specific use. BLUELINE DIGITAL MKII SERIES www.workpro.es 4

Audio extracting methods It is important to emphasize that each audio receiver is only capable of extracting one stereo audio channel from the network. The extraction of this channel can be done in different ways, that can be select in the configuration interface of WorkCAD3 Configurator. 3.1.1. DUAL Stereo extraction mode. Each input is assigned to its output. 3.1.2. SINGLE Individual extraction mode. Of the two parts that one stereo channel is conformed (1-L or 2- R), we choose one of them, to extract it by both outputs of the receiver. In this example we select 1-L BLUELINE DIGITAL MKII SERIES www.workpro.es 5

3.1.3. MONO Mono extraction mode. The two input channels (1-L and 2-R), are summed to extract them by both outputs of the receiver. 6 db are subtracted from each output to compensate for the electrical sum of two input channels. 3.1.4. INVERT OUT Inversion of the polarity for output 2, in order to create a balanced output. This option is only available for SINGLE and MONO modes. In this case, we select MONO mode. BLUELINE DIGITAL MKII SERIES www.workpro.es 6

4. BLR2 A PLUS MKII The BLR2 A PLUS MKII is an audio over IP receiver, that can extract one of the channels transmitted by the Blueline MKII senders with a built-in amplifier. Also, the BLR2 MKII includes 2xGPIs (pull-up) and 2xGPOs (open collector). The device can be powered by either PoE or an external power supply. It is important to stress, that one receiver cannot mix channels from different senders. BLUELINE DIGITAL MKII SERIES www.workpro.es 7

Features Analog audio Line output Number of channels 1 stereo channel (unbalanced) or 1 single/mono channel (balanced) Audio connector Euroblock, 3 pin 5.08mm Output sensitivity -1.15 dbu (640mV rms) Amplified audio output Power output, dual mode (24Vdc) Power output, bridge mode (24Vdc) Power output, dual mode (PoE) Power output, bridge mode (PoE) Audio connector GPIO Connector GPIs GPOs Network Connector Audio over IP Ethernet Main supply External power supply PoE Class Consumption General Control protocol Audio extraction modes Dimensions Weight 2x 15W @ 4 Ω 1x 30W @ 8 Ω 2x 5W @ 4 Ω 1x 10W @ 8 Ω Euroblock, 3 pin 5.08mm 2X Euroblock, 3 pin 3.81 mm Pull-up resistor, 5 Vdc max. Open collector, 12Vdc max, 1A max. RJ-45 BlueLine UDP datagrams 100 Base TX 12/24 Vdc (Not included) Class 0 802.3af 1.5 W OSC Stereo/Single/Mono 109mm 133.75mm 40.45 mm 360 g BLUELINE DIGITAL MKII SERIES www.workpro.es 8

Device description 1. Reset button. Take the device to its factory configuration 2. Next button. It allows to advance between and through the different screens of the display. 3. Display. It shows different features of the device. 4. Set button. It allows access to a certain display screen and set the digits of the different screens. 5. GPIOs: GPIOs connection ports. 3-pin Euroblock connector with 2x GPO plus GND and 3-pin Euroblock connector with 2x GPI plus GND. 6. LAN port. Connection port to the local network, RJ45. 7. Main supply input. 12/24 Vdc 8. Control. Connection port for the BLC 1wallmount controller (RJ 45) 9. Analog audio output. Unbalanced or balanced audio output, (depending on the extraction method), 3-pin Euroblock of 5.08 mm. 10. Power amplifier output: Dual and Bridge modes, depending on the chosen extraction method. 3-pin connector. 4.2.1. Display On the front of the device you will find a display through which you can view or modify different parameters of the unit. To navigate between the different parameters press the NEXT button if you want to edit any of these parameters, press the SET button to access it. Next, specify which parameters are editable and which are not: BLUELINE DIGITAL MKII SERIES www.workpro.es 9

- STATIC IP, editable. - DYNAMIC IP, not editable. - MAC, not editable - SRC, editable. - VOL, editable STATIC IP, this is the static IP address. The device has a static IP address by default in the subnet 10.0.0.0/8. For editing, use the SET (to select and set the digit) and NEXT (for editing upwards) buttons. NOTE: After a change, the device restarts to confirm the value. DYNAMIC IP, this is the dynamic IP address of the device, which is assigned by a DHCP server. MAC, this is the physical address of the device. SRC, it refers to the channel (Source) in which the device transmits. For editing, use SET (to select and set the digit) and NEXT (for editing upwards) buttons. VOL, It refers to the master volume of the device, and can be modified between the values [- 40dB, 3dB]. For editing, use SET (to access and set the volume) and NEXT (for editing upwards) buttons. BLUELINE DIGITAL MKII SERIES www.workpro.es 10

4.2.2. Analog audio output The analog audio output of the device can be balanced or unbalanced according to the selected extraction mode. keep in mind the following types of connection: STEREO UNBALANCED MONO UNBALANCED MONO BALANCED BLUELINE DIGITAL MKII SERIES www.workpro.es 11

4.2.3. GPIOs General Purpose Inputs Outputs, the device includes 2xGPIs and 2xGPOs. - GPIs: Inputs that senses logic voltage variations, in order to send UDP/OSC control commands when a variation occurs. A typical configuration would be the connection of a push button between one GPI and GND, so when the push button is pressed the UDP/OSC commands programmed are sent to the network. - GPOs: Outputs in open collector configuration, which once activated let flow current through them. A typical configuration would be the interconnection of the coil of a relay. 4.2.4. LAN port RJ45 port for LAN connection. Allows PoE power (Class 0 802.3af). Next to the RJ45 connector you will find two LEDs indicating the status of the device: LINK (green) ACT (orange) Indicates that the BLS2 Lite MKII is connected to the LAN Indicates that packets are being sent or received 4.2.5. Control This port allows the connection of a BLC 1 wall controller acting as a local controller. In this way, it is possible to select the audio source to be extracted and its volume. 4.2.6. Main supply input Power input for external source. The admitted voltage can be between 12/24 Vdc, with a minimum current of 500 ma. BLUELINE DIGITAL MKII SERIES www.workpro.es 12

Check the current polarity before connecting the main supply The external power supply is not provided with the device. 4.2.7. Amplified audio output The power output of the device will depend on the type of main supply used. If we want to obtain the maximum power, we must supply it with an external source of 24Vdc, then the different powers offered are detailed according to the power and mode of use: Amplified audio output Power output, dual mode (24Vdc) Power output, bridge mode (24Vdc) Power output, dual mode (PoE) Power output, bridge mode (PoE) 2x 15W @ 4 Ω 1x 30W @ 8 Ω 2x 5W @ 4 Ω 1x 10W @ 8 Ω As can be seen in the table, we can make a BRIDGE configuration so that the device will deliver all its power in a single output. Remember that the minimum load in this mode of use will be 8 Ω. We will choose the audio extraction mode using WorkCAD3 Configurator. Next, the different types of connection are detailed according to the audio extraction mode. DUAL BRIDGE BLUELINE DIGITAL MKII SERIES www.workpro.es 13

Device setup The configuration of the device can be done by software (WorkCAD3 configurator) or through display. The most comfortable way for the user is through WorkCAD3 configurator, since he will have access to all the functionalities of the device and he can also see the interaction of the device with the rest of the BlueLine Digital MKII network elements. 4.3.1. Setup through WorkCAD3 Configurator After making the IP level configuration of the device and updating it if would be necessary (see WorkCAD3 Configurator manual), proceed with its setup. If you click on the device with the left mouse button, the configuration interface will be opened and the following parameters will appear: - Zone: This field refers to the zone to which the device belongs, in order to receive OSC control commands. By default, all BlueLine receivers are in zone 1. - Generate Ding Dong: Button to execute a Ding Dong signal in the receiver. It is useful to recognize/check the speakers connected to this receiver. - Channel: Number of the stereo audio channel that we want to extract. - Controller s offset: Field to enter an offset in the wallmount controller (BLC 1 or WNC 1) that manage the device. For example, if we enter "1" in this field, the minimum channel that can be chosen in the wall-control will be "1", so if we have a reserved source in channel "0", the user will not be able to access it. BLUELINE DIGITAL MKII SERIES www.workpro.es 14

- Output mode: Dual: Stereo audio extraction. Single: Audio extraction in individual mode. Mono: Extraction of audio in mono mode, adding the two channels and extracting it for both outputs with an attenuation of -6 db. Channel: Selection of the channel to be extracted in individual mode.1 (L) or 2 (R). Invert Out 2: Polarity inversion of output 2 to obtain an unbalanced output. Only available in Single and Mono modes. See section 3.1 (Audio extraction methods), for more details. - Volume: Field dedicated to control the volume and mute of channels 1, 2 and Master. - Banks: Field dedicated to the programming of the GPIs of the device. Bank: Selection of GPI. Event: Selection of the command event mode, according to the GPI state. On Activate/GPI is closed, On deactivated/gpi is opened. OSC Methods: Field dedicated to the inclusion of UDP / OSC commands, review OSC Editor in the WorkCAD3 configurator manual. - GPIOs: Field dedicated to reporting on the status of GPIOs, light on-activated / ligth off-deactivated. In the case of GPOs you can click on the buttons manually to test them. BLUELINE DIGITAL MKII SERIES www.workpro.es 15

Accessories The BLR 2 A PLUS MKII includes a series of accessories for mounting on a wall or with the rack accessory BL AR 19 (not included): - 2x Wings for mounting in a wall. - 4 screws. - 1x Bar to joint two devices. - Optional BL AR 19 Fixing accessory for standard rack 19" 1 HU to accommodate up to 4 devices of the Blueline MKII series. BLUELINE DIGITAL MKII SERIES www.workpro.es 16

BLUELINE DIGITAL MKII SERIES www.workpro.es 17