cmt-g01 with OPC UA Server and Modbus Gateway

Similar documents
cmt-g04 with OPC UA Server and MQTT Sparkplug B cmt-g04 with OPC UA Server and MQTT Sparkplug B

User. Manual. cmt-3103 Wireless Network Settings Guide. Weintek USA, Inc. (425)

SQL Synchronization and SQL Query to MS SQL Database. SQL Synchronization and SQL Query to MS SQL Database

Weintek HMI to Control Techniques M400 AC Drive via Modbus TCP/IP Ethernet Module

User. Manual. cmt-hdm Startup Guide. Weintek USA, Inc. (425)

User. Manual. cmt-fhd Startup Guide. Weintek USA, Inc. (425)

19.Configure HMI as a MODBUS Server

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

We provide the most advanced and stable HMI product solutions

cmt3090 and Remote I/O Quick Start Guide

3.1 Updating Web Package Updating OS... 16

Ethernet HMi RAC and Gateway Setup Instructions Rev. 09

Easily Extend Ignition to the Edge of Your Network

We provide the most advanced and stable HMI product solutions

EasyBuilder Pro V This model is a gateway device; therefore, it is not possible to generate a

Software Version: EasyBuilder Pro V

Set HMI as a MODBUS Server

ThingsPro Software Suite Version 2 User s Manual

Brother HL-5370DW Configuration

Any device, including routers and hosts, is running an implementation of IP address Host

cmt Quick Start Guide

Lab - Connect to a Router for the First Time

UA Series IIoT Communication Server

EZ-ETHERNET APPLICATION GUIDE

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Connecting UniOP to Modbus/TCP

EM4 MODBUS TCP/IP ADDRESSING CROUZET TOUCH TUTORIAL

UCOS User-Configurable Open System

EKI-6332 & EKI-136x- MB_setup example SOP. Revision Date Revision Description Author April/2018 V1.0 Initial release ICG AE Jacky.

SCADALink IP100 SCADA Terminal Server QUICK START GUIDE Revision 1.42 June 19, 2012

ThingsPro Version 2 User s Manual

Plus-X I/O Units. Manual Supplement Configuring Units with and without DHCP

Note: This manual now is also applied to ELC-E-Ethernet module

Multitouch/BACnet Functional description UMG 604 / UMG 605 / UMG 508 / UMG 511

Ignition HMI interface to Fanuc Industrial Robots

OUTDOOR IR NETWORK CAMERA Series

WSDA User Guide

TECHNICAL NOTE TNOI38

ACC1000 QUICK NETWORKING GUIDE

We provide the most advanced and stable HMI product solutions

8.9.2 Lab: Configure an Ethernet NIC to use DHCP in Windows Vista

Title: Can I use Ethernet to read and write values to my HMI?

EasyBuilder Pro V Added the following new features to the editing window in this release:

Ethernet Network Card Installation and Operation Manual

Modicon Modbus Driver

Configuring an Omron PLC with Omron FINS Ethernet Driver

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Danfoss Enspire a web-based SCADA software application

UA-5000 Series User Manual

EGW1-IA3-MB User s Manual

In this tutorial, we are going to demonstrate how to connect the Weintek ip series HMI device with UniPi controller running Mervis.

Quick Setup Guide. for Standalone Omada Access Points. EAP110 / EAP115 / EAP225 / EAP245 / EAP320 / EAP330 / EAP115-Wall

EasyBuilder Pro V Build

B-Scada and Security

May 2016 Version 1.2.7

1. By adding [MODBUS Server] with [Ethernet] interface, the [MODBUS TCP/IP. Gateway] feature can be enabled by selecting the [Enable] checkbox.

WebNMS IoT Cloud Gate Deployment Guide

How to Build a Real-Time IIoT Application with Moxa's ThingsPro and Cirrus Link's Sparkplug

Copyright 2016 GE Multilin Inc. All rights reserved. EnerVista Integrator Quickstart Guide for version 8.0x. EnerVista, Integrator, POWER LEADER,

ETOR-4. Ethernet/Serial Gateway USER MANUAL

Site Book User s Guide

WISE-52xx Intelligent IIoT Concentrator

User Guide Part 12. Data Connector Service

Application Note Redundancy Configuration FG-110 FF

ThingsPro Software User s Manual

JNIOR Series 3 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 3.3 NOTE: JNIOR OS 3.4 or greater required

QSTD Series Port Forwarding Instructions

Features. Support XV-board

Software Version:EasyBuilder Pro V

INSTALLATION INSTRUCTION MANUAL

ST-HD-CVR4CH ST-HD-CVR8CH ST-HD-CVR16CH. Professional Digital Video Recorders QUICK START GUIDE

USER MANUAL Z-KEY MODBUS ETHERNET SERIAL GATEWAY AND SERIAL DEVICE SERVER. Via Austria, PADOVA ITALY

Configuring the UMTS router. Application for the Web-IO Digital: Configuring a UR 5 UMTS router for connecting the Web-IO over the cell phone network

Expansion Module MAC00-FB4 (Bluetooth),FZ4 (IEEE ) and EW4 (WLAN) overall description

Software Version:EasyBuilder Pro V

BMS-Ethernet-Gateway COM460IP

FOR IMMEDIATE RELEASE

Modbus TCP Server Driver for JMobile

USING THE XPERT2 / 9210B ON A TCP/IP NETWORK

MBX Network Browser Help 2010 Kepware Technologies

All configuration in this document refers to the EZ Setup section.

Please refer to application note AN00129 for further details on HCP2 configuration in ABB motion control products.

EasyBuilder Pro V screen and editing the project with the Work Space window open.

A. Insert CD and wait until the installation wizard comes up on your screen

datafeed OPC Suite The All-in-one Data Integration Solution Haar,

How to Build an IoT Application with Moxa's ThingsPro and AWS IoT Service

Using Modbus TCP with Brainboxes products

Custom IP Address Setup / Configuration

Industrial 1-port RS422/485 Modbus Gateway IMG-110T

4-1. This chapter explains HMI settings.

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide

Configuring the network clients

What s New in Ignition v7.9

ETOR-4 Ethernet/Serial Gateway ETOR-4. Ethernet/Serial Gateway USER MANUAL

PRELIMINARY DESCRIPTION

X Series Application Note 34 Using Acromag 967 Modbus/TCP module as Remote I-O with the X-Series Recorder

PMAC770 LAN Module User Manual V1.0

User Manual. cmt-svr Startup Guide

IntesisBox Modbus Server - Honeywell XLS 80

Industrial 2-port RS422/485 Modbus Gateway IMG-120T

Transcription:

Introduction: Weintek USA, Inc. Rev. Oct 31 2018 www.weintekusa.com (425) 488-1100 cmt-g01 with OPC UA Server and Modbus Gateway Industrial IT Technology has quickly advanced with the integration of plantfloor data, supervisory control demand, ERP, and even new cloud-based applications. Integrating legacy and different brands of factory machines has never been an easy task since the controllers in a factory use different communication protocols. To facilitate integration of numerous proprietary protocols, Weintek has developed the first Gateway protocol converter: cmt- G01. The cmt-g01 gateway provides the necessary IIoT connectivity to retrofit existing machines into a single protocol. This document discusses how to utilize the cmt-g01 to build an OPC UA server, which is a standard protocol for IIoT systems, and allows OPC UA client to access data. Benefits of cmt-g01 Supports OPC UA for Integration of SCADA or ERP systems Supports MQTT and has built-in broker for publish-subscribe messaging protocol Connectivity to AWS, Azure, and IBM IoT platforms via MQTT Supports MQTT Sparkplug B specification Supports Modbus gateway Supports Protocol conversion Additional Data logger and event detector SQL synchronization capability to MySQL and MS SQL database server for data log and event log EasyAccess2.0(Optional) Remote access factory equipment Page 1 of 15

Equipment & software: 1. HMI 2. Arduino board 3. ir-etn remote IO 4. cmt-g01 Note: In this demonstration, Easybuilder pro version 6.01.02 is used. Wiring diagram: Before configuration- The HMI communicates with the Arduino board via Modbus RTU protocol. The HMI communicates with the ir-etn remote IO via Modbus TCP protocol. After configuration- In this way, the HMI program is changed because the HMI uses Modbus TCP Master protocol to query the cmt-g01. The cmt-g01 acts as a ModbusTCPto-ModbusRTU bridge, which is a Modbus gateway. It saves the cost of purchasing an extra communication module of the PLC. Page 2 of 15

Hardware configuration: I/O ports of cmt-g01 - Software configuration: Launch Easybuilder Pro and select cmt-g01 Gateway. Page 3 of 15

The popup window will be displayed as shown. Click [New Device] to select drivers of the controllers. Add this driver Modbus TCP/IP into [Device list]. Enter the IP address of the ir-etn. Page 4 of 15

Add this driver Modbus RTU,RTU over TCP into [Device list]. Enter the communication parameters of COM port. [Device List] includes two drivers to communicate with the ir-etn and the Arduino board. Double [Local HMI] to change the name of the cmt-g01. Page 5 of 15

Click [OK] to close [System Parameter Settings]. You can see the three main steps on the main screen to complete this project. Step 1. Step 2. Step 3. Add a driver into Device List in the project. (This step is completed) Enable OPC UA Server and designate PLC addresses. Download this project to cmt-g01. Step2. - Click [OPC UA] button on the main screen or go to [IIoT/Energy]» [OPC UA Server] on the toolbar, and check [Enable] checkbox to enable OPC UA server. Page 6 of 15

Click [Tags] within [IR-ETN remoteio](controller name) and then click [New Tag] to add OPC UA tags. For example, add a tag for the output of the ir-etn. [Name]: Enter a tag name. [Type]: Data type is Bit. [Address]: Enter Modbus function code + register number (Decimal). [Type]: data is readable and writable. Click [OK] to exit. Page 7 of 15

Click [Tags] within [Arduino board](controller name) and then click [New Tag] to add OPC UA tags. For example, add a tag for the analog input of the Arduino board. [Name]: Enter a tag name. [Type]: Data type is Word. [Address]: Enter Modbus function code + register number (Decimal). [Type]: data is readable. Click [OK] to exit. The window as shown includes all tags created in the OPC UA server. Page 8 of 15

Modbus gateway configuration - Click [Settings] button on the main screen or go to [Home]» [System Parameters] on the toolbar, add this driver Modbus Server into [Device list]. Check the checkbox within [Modbus TCP/IP Gateway] and go to [Address Mapping Tables]. The window Address Mapping table will be displayed as shown below. Click [Add] to open table settings for register mapping. Page 9 of 15

[Address mode]: Data type is Word. [Type]: Select Read/Write. [Modbus address]: Enter Modbus TCP function code + register number (Decimal). [Mapped device address]: Enter Modbus RTU function code + register number (Decimal). [Table size]: Total memory size. (Unit: words) The Modbus gateway is added to [Device list] as shown. Page 10 of 15

Change the HMI program to read and write Modbus TCP registers. The following Modbus function codes are supported. Modbus Function Code Definition 1 Read Coil Status 2 Read Input Status 3 Read Holding Registers 4 Read Input Registers 5 Force Single Coil 6 Preset Single Register 16 Preset Multiple Registers Step3. - Connect the LAN1 port of the cmt-g01 and the PC to a router with an Ethernet cable. Click [Download] button on the main screen or go to [Project]» [Download] on the toolbar. Find the cmt-g01 and click [Download]. Page 11 of 15

You can change the LAN1 IP address of the cmt-g01 by going to [Search and Change IP]. Disable DHCP and then enter IP address as well as subnet mask according to the company/ factory network. Click on [Apply] to finish. The popup window will show Successfully updated Ethernet settings. Change the IP address of the LAN2 Connect the LAN1 port of the cmt-g01 and the PC to a router with an Ethernet cable. Open a web browser (IE, Chrome, or Firefox) on a PC, and make sure the IP address of the PC has a same subnet IP. Enter the IP address of cmt-g01. For example, 192.168.0.133. Select an identity and enter its password. The default password is 111111. Go to [Network] tab. The IP address of the Ethernet1 is the IP address of LAN1 port, and it is changed by the earlier step. Page 12 of 15

Click [Ethernet2] and then enter the IP address as well as mask for the communication of the machine network. Page 13 of 15

Testing: Launch the OPC UA client software UAExpert on a PC to monitor OPC UA tags data. You can drag and drop tags configured in the OPC UA server to [Data Access View]. Page 14 of 15

The data will be displayed as shown. Reference Link: Weintek Labs website: http://www.weintek.com Founded in 1996, WEINTEK LABS is a global-leading HMI manufacturer and is dedicated to the development, design, and manufacturing of practical HMI solutions. WEINTEK LAB s mission is to provide quality, customizable HMI-solutions that meet the needs of all industrial automation requirements while maintaining customer satisfaction by providing on-demand customer service. WEINTEK LABS brought their innovative technology to the United States in 2016, WEINTEK USA, INC., to provide quality and expedient solutions to the North American industrial market. 6219 NE 181s Street STE 120 Kenmore, WA 98028 425-488-1100 Page 15 of 15