DRI. VARIZON Displacement unit with adjustable spread pattern

Similar documents
DKC. VARIZON Displacement unit with adjustable spread pattern

GTH. Rectangular double deflection grille QUICK FACTS

IBISTM. Duct diffuser with discs for supply air

VIREO Ceiling with ALX

IBIS. Duct diffuser with discs for supply air QUICK FACTS

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS

Floormaster DVQA, quarter-cylindrical terminals

SIRI. Measurement and control damper QUICK FACTS

Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser

Ceiling diffusers - visible

Adjustable swirl diffuser PDZA TECHNICAL DATA

SLOT DIFFUSERS ALS SERIES SLOT DIFFUSER ALS37. The Airvector exclusive UNIFLEX pattern and volume controller Deflector-damper

Ventilation grille. Dimensions

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

NORDgrille Internal grilles

Circular and semi-circular displacement outlet Q-Z...

ROL and ROL-S. climecon.fi

Grilles Type AR. AE for return air 1 / 1.3 / B / 1

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage

diffusers F24 PERFORMANCE DATA PERFORMANCE DATA ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Throw correction multiplier for length

LOOK hidden linear diffusers

Catalogue. Swirl 5. Ceiling Swirl Diffuser Fixed Air Pattern.

Grille. Min. - max. dimensions

Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA

LOCAL EXTRACTORS Pure advantages. The ideal extractor for industrial environments.

AIR CONDITIONING PRODUCTS COMPANY

Jet nozzle, type DW-N2 Swivel jet nozzle, type DW-V2 Twist nozzle, type DW-V2-...-DR

SYSTEM 25 SYSTEM 50 AS SYSTEM 63 SYSTEM 75 SYSTEM 100. Alsident System 50. Antistatic (AS) Product Information

Square swirl diffuser PZK(A,B), PWK(A,B)

HOMESCREEN DELUXE Fixed frame projection screen for wall installations

HOMESCREEN DELUXE Fixed frame projection screen for wall installations

Linear Luminaire with LED Series 6012/5

LDK Slot Diffusers. Description. Throw directions. 2

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Multitronic. Technical data

Linear Luminaire with LED Series 6412/5

Incorporating V2.2. Product spec >>> > Series CD - Ceiling diffusers

Filter Fan Unit LIGHT

Rectangular straight silencer

DIRECT DRIVE VANEAXIAL FIXED PITCH FANS

SYSTEM WORLD PRODUCT INFO

S u p p l y a i r h o o d J S I

Swirl diffusers, Variable swirl diffusers Swirl diffusers

CEILING SWIRL DIFFUSER MLD

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

Hudevad Plan XV. technical datasheet

INSTALLATION INSTRUCTIONS

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

89SV80/R1200. Mechanical Components. Marshalling rack cubicle with double-sided MTP-Elements. Application. Description. Cubicle

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

BAR GRILLE TYPE: A-600

1450 First Ave. Page 1 of 7 Chippewa Falls, WI (800) or (715) Fax: (715)

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

TILBURY STEEL SERVICE CENTRE

Model R3001. Instruction Manual. Anemometer/Manometer. reedinstruments. www. com

EVOTEK ADVANCED CEILING TECHNOLOGY

Starnet Access Flooring. Low-Profile Wire Management System

Variable Flow Rate Control Unit

Vertiv VR Rack 1.0 GENERAL

Floor Standing Rack Cabinet

Air Gauges are ideally suited to both harsh and controlled environments, as the Air Flow disperses coolants, oil, dust, etc., from the measuring area

Index. E Expanded Metal Raised Flattened Grating... 93

CONTROLLING ROOFTOP UNIT (RTU) NOISE

Limanda. Technical data

Elabo TaMo. Mobile carrier system for industrial use

CONDUCTOR W4. Installation instruction for W4.1 and W To mount the controller. Controller. Mounting on a DIN rail

BPL SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Standard Construction. Options and Accessories

DCV-SP DCV-SP. DCV-SP Pressure control SPL Version B03 with actuator DA4/8 SMART DAMPERS & MEASURING UNITS. Product description AIN DIN AOUT DCV-SP

PD2.5 PROJECTOR DROP MECHANISM TECHNICAL SHEET ISSUE 005 SHEET 1 UK +44 (0) US +1 (603)

Call to Order! 1

Webb Core Cleanroom Wall System

F O R U M S E R I E S

U V-Tu r b o h o o d s

North US 290 US 183. MLK Blvd. FM 969. ASERO Steel Sales. Ben White TX 71 IH-35 US 183

Heavy Duty Hot Wire CFM Thermo-Anemometer

Featured Products - RU Marking Standard on Hoffman brand

Product Library and ISO 16757

TENSIONED DESCENDERPRO

TECHNICAL DATA SHEET -

OPERATION AND MAINTENANCE INSTRUCTIONS FOR THE SILVER C RX/PX/CX/SD

Technical Information DAMPA TILES Decorative Marine Ceiling System

TYPE 4/12 PREMIER SERIES

Cabinet. DT-NCW NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT

Ravenna TM. Fixture Options: Ordered Separately from Fixture. See page 2. Mounting Options: Ordered Separately from Fixture.

Ravenna TM. Fixture Options: Ordered Separately from Fixture See page 2. Mounting Options: Ordered Separately from Fixture See pages 3-5

ORLANDO BERLIN. High quality and elegance à from the doorplate to the outdoor stand the lightly

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

PD1 Projector Drop Mechanism FUTUREAUTOMATION. Technical Sheet FUNCTION

Vertiv Knürr MIR2 One system with Infinite Possibilities

Heavy Industrial Shock Absorbers ECA 2 to ECA 4 Self-Compensating

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

Kully Reference Book

Common grade: ASTM A36..min. 36,000 yield / min. 58,000 tensile. Size Weight (lbs.) Weight (lbs.)

2019 Data Center Solutions

Knürr Synergy The New Product Family For Uniform Equipment In Your Control Room. Knürr Technical Furniture

Product information 19" 1U UniRack2 24xLC-Duplex G.652.D, PC, ceramic, C/2 R819330

CATALOG NUMBER PROJECT W2 TRACK AND COMPONENTS

Transcription:

VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of rooms Cleanable Air volume measuring point Very simple to install in suspended ceilings or in walls Concealed fastening Available in alternative colors Quick guide A I R F L O W S O U N D L E V E L Cubic feet per minute NC NC NC 0 3 0 47 0 0 6 70 31 770 900 0 0 190 170 0-600 90 0-800 1800 Sound level is valid at 16 ft 2 equivalent sound absorption area at distance of 6 ft from terminal. All values are valid without disturbance on straight duct section. 1

Technical description Design The is a complete, rectangular displacement unit for placing on a floor, in a wall or ceiling. The body consists of a rear section with side, top, and bottom plates and an air distribution plate equipped with a number of adjustable discs. The top plate has a circular inlet socket for 0 up to 0. 0-600 and 0-800 have a rectangular inlet spigot. The diffusion plate has an access hatch for access to the duct system. There are one or more perforated front plates attached to the front of the body. 0 and 0 have one front plate. 31, 0, 0-600, and 0-800 have two front plates which are screwed to the body of the displacement unit. The screws are concealed by an aluminum strip. White painted angle profiles are supplied with the unit and are used when surface mounted or flush mounted. Materials and surface treatment The displacement unit is manufactured in galvanized sheet steel and aluminum profiles. It is coated with our pure white standard paint, RAL 90. The unit is also available in other standard colors; Dusty grey RAL 7037, White aluminum RAL 9006, jet black RAL 900, grey aluminum RAL 9007, and signal white RAL 9003 (NCS 000). Customization In addition to the standard sizes, these displacement units are available in special dimensions, with reinforced front plates etc. Please, contact your nearest sales representative for further information. Planning It is possible to modify the affected area by adjusting the discs behind the front plates. This does not affect the air flow, pressure drop or sound level. This flexibility simplifies any future changes in the furnishing of the room etc. Note: The sound level in the engineering diagrams is valid at 16 sq ft equivalent sound absorption area. This fact makes it important to check the air velocities in the connecting ducts to the terminals. Extra consideration has to be taken on how the ducts can be connected to the terminals. See figure 3. Installation The unit is mounted on the wall using angle mounting profiles. In the case of ceiling mounting, either drop rod or perforated band is used to attach the unit to the framework of the building. When flush mounted, the angle profiles are used as a frame around the unit to cover the edges of the hole cut for it. For ceiling mounting, the front plates should be secured with screws. This applies to 0 and 0 only. See figure 1. Commissioning The measuring point is located on the upper edge of the displacement unit, above the front panel. The k-factor of the unit is stated on the product label, and can also be found in the relevant k-factor guide at www.swegon.com. It is recommended that a measuring and commissioning damper is used to regulate the air flow. It should be placed at least 3-4 duct diameters away from the displacement unit inlet. See figure 2. Maintenance The displacement unit can be cleaned when necessary using lukewarm water with detergent added. The duct system is accessible by removing the perforated front plate and the access hatch. See figure 2. 2 Swegon reserves the right to alter specifications. 14 www.swegon.com

Figure 2. Commissioning. Maintenance. Technical data Sound level NC applies to a room attenuation of 16 db, measured 6.6 ft from the displacement unit, installed with a straight section of duct before the unit. Obstructions in the connecting duct will have a negative effect on the sound level, see figure 3. Recommended maximum under temperature is - F. To calculate the width of the spread pattern, air velocities in the zone of occupation or sound levels in rooms with other dimensions, please refer to our calculation software, ProAir web, available for download at www.swegon.com. 0 0 Table Duct connections Effects on sound levels (db) for different duct connections and different air velocities in straight duct sections. Velocity (FPM) Duct connections (db) A B C D 78-98 +2 +6 +3 +3 1180-180 +4 + +6 +6 31 0 Figure 3. E.g. of how different duct connections affect the sound level of the terminal. Figure 1. Installation. Swegon reserves the right to alter specifications. 14 www.swegon.com 3

Engineering graphs Air flow Pressure drop Sound level Affected area Sound level NC applies to a room attenuation of 16 db. Maximum recommended temperature difference is - F. Graphs refer to a displacement unit installed on a wall, 4" above floor level. The affected area refers to the distance to the isovel limit of FPM at t - F. In this case, t signifies the difference between the room air temperature and the supply air temperature, measured at 4 ft above floor level. It does not refer to the difference between the extract air and the supply air temperatures. The graphs are not to be used for commissioning. = min air flow to obtain sufficient commissioning pressure. Figure 4. Affected area. 0 0 1 1 0 0 0 0 00 00 0 0 0 00 00 00 a FPM b FPM 2 3 4 3 4 a FPM b FPM 4 31 0 0 0 00 00 00 00 00 00 00 00 00 a FPM b FPM 0 a FPM b FPM 0 0 4 Swegon reserves the right to alter specifications. 14 www.swegon.com

0-600 0-800 0.01 0 a FPM 0 00 00 b FPM 00 4 0.01 00 00 a FPM b FPM 00 00 00 00 0 Dimensions and weights Dimensions (in) Weight (lbs) A B C ØD*) E FxG H 0 23.28 11.81 7.87 4.3 0.6 0 23.28 13.78 9.84.1 9 31 16.39 12. 6.81 171.6 0 19.68 1.7 8.46 178.2 0-600 11.81 7.87 x 23.62 2.17 160.6 0-800 13.78 9.84 x 31.0 2.9 16.0 Size**) The models with circular duct connections have an internal socket connection. The unit of the size column is in millimeters and should be primaraly considered as a denomination when referring to products or placing orders. Corresponding measurements in inches can be seen in the "ØD" (DIR, circular connection) and "F x G" (DIR, rectangular connection) columns. *) **) A ± 1/16 (± 2 mm) A ± 1/16 (± 2 mm) 3/16 ( B ± 1/16 (± 2 mm ) B ± 1/16 (± 2 mm ) Figure. 0 to 0. Swegon reserves the right to alter specifications. ) mm Figure 6. 0-600, 0-800. 14 www.swegon.com

Ordering key Product designation Rectangular displacement unit with circular connection Version: Size (mm): 0, 0, 31, 0 Rectangular displacement unit with rectangular connection Version: Size (mm): 0-600, 0-800 f -aaa f -aaa - bbb Specification example SD XX Swegon VARIZON rectangular displacement unit, with the following functions: Adjustable spread pattern and affected area Interchangeable front sections Non-fouling Air volume measuring point Cleanable Cover strips for flush mounting Powder painted in white, RAL 90 Size: f aaa - bbb xx items 6 Swegon reserves the right to alter specifications. 14 www.swegon.com