Total Variation Regularization Method for 3-D Rotational Coronary Angiography

Similar documents
Total Variation Regularization Method for 3D Rotational Coronary Angiography

Spatial-temporal Total Variation Regularization (STTVR) for 4D-CT Reconstruction

Iterative CT Reconstruction Using Curvelet-Based Regularization

NIH Public Access Author Manuscript Med Phys. Author manuscript; available in PMC 2009 March 13.

Scaling Calibration in the ATRACT Algorithm

The Near Future in Cardiac CT Image Reconstruction

Make the Most of Time

2D Vessel Segmentation Using Local Adaptive Contrast Enhancement

Portability of TV-Regularized Reconstruction Parameters to Varying Data Sets

Reconstruction of CT Images from Sparse-View Polyenergetic Data Using Total Variation Minimization

Respiratory Motion Compensation for C-arm CT Liver Imaging

Depth-Layer-Based Patient Motion Compensation for the Overlay of 3D Volumes onto X-Ray Sequences

Respiratory Motion Estimation using a 3D Diaphragm Model

Gradient-Based Differential Approach for Patient Motion Compensation in 2D/3D Overlay

GPU-based Fast Cone Beam CT Reconstruction from Undersampled and Noisy Projection Data via Total Variation

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Compressed Sensing for Rapid MR Imaging

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset

Automatic Removal of Externally Attached Fiducial Markers in Cone Beam C-arm CT

Quality Guided Image Denoising for Low-Cost Fundus Imaging

Motion Compensation from Short-Scan Data in Cardiac CT

Penalized-Likelihood Reconstruction for Sparse Data Acquisitions with Unregistered Prior Images and Compressed Sensing Penalties

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

Separate CT-Reconstruction for Orientation and Position Adaptive Wavelet Denoising

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT

Image registration for motion estimation in cardiac CT

Dynamic Cone Beam Reconstruction Using a New Level Set Formulation

Intensity-Based 3D-Reconstruction of Non-Rigid Moving Stenosis From Many Angiographies erschienen in

High Performance GPU-Based Preprocessing for Time-of-Flight Imaging in Medical Applications

Geometry-Based Optic Disk Tracking in Retinal Fundus Videos

Cardiac C-arm CT: Efficient Motion Correction for 4D-FBP

An Efficient Technique For Multi-Phase Model Based Iterative Reconstruction

Respiratory Motion Compensation for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data

4D Computed Tomography Reconstruction from Few-Projection Data via Temporal Non-local Regularization

Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation

DUE to beam polychromacity in CT and the energy dependence

EM+TV Based Reconstruction for Cone-Beam CT with Reduced Radiation

Residual Motion Compensation in ECG-Gated Interventional Cardiac Vasculature Reconstruction

MOTION of a patient induces artifacts such as streaks

Single Breath-hold Abdominal T 1 Mapping using 3-D Cartesian Sampling and Spatiotemporally Constrained Reconstruction

Automatic Extraction of 3D Dynamic Left Ventricle Model from 2D Rotational Angiocardiogram

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Constrained Reconstruction of Sparse Cardiac MR DTI Data

A Simulation Study and Experimental Verification of Hand-Eye-Calibration using Monocular X-Ray

A new calibration-free beam hardening reduction method for industrial CT

Detecting Burnscar from Hyperspectral Imagery via Sparse Representation with Low-Rank Interference

Image-based Compensation for Involuntary Motion in Weight-bearing C-arm Cone-beam CT Scanning of Knees

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection

Cardiac C-arm computed tomography

Estimating 3D Respiratory Motion from Orbiting Views

Improvement and Evaluation of a Time-of-Flight-based Patient Positioning System

Automatic Extraction of quasi-synchronous Views from Rotational Angiographic Sequence without ECG-Data

Top-level Design and Pilot Analysis of Low-end CT Scanners Based on Linear Scanning for Developing Countries

On the Characteristics of Helical 3-D X-ray Dark-field Imaging

Edge-Preserving Denoising for Segmentation in CT-Images

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

Non-Stationary CT Image Noise Spectrum Analysis

Accelerated C-arm Reconstruction by Out-of-Projection Prediction

Efficient MR Image Reconstruction for Compressed MR Imaging

Introduction. Wavelets, Curvelets [4], Surfacelets [5].

Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004

Research Article Iterative Image Reconstruction for Limited-Angle CT Using Optimized Initial Image

Guided Image Super-Resolution: A New Technique for Photogeometric Super-Resolution in Hybrid 3-D Range Imaging

Advanced phase retrieval: maximum likelihood technique with sparse regularization of phase and amplitude

ONE of the issues in radiology today is how to reduce the. Efficient 2D Filtering for Cone-beam VOI Reconstruction

DOWNWARD SPATIALLY-SCALABLE IMAGE RECONSTRUCTION BASED ON COMPRESSED SENSING

P257 Transform-domain Sparsity Regularization in Reconstruction of Channelized Facies

Comparison of Default Patient Surface Model Estimation Methods

Towards full-body X-ray images

Quantitative Study on Exact Reconstruction Sampling Condition by Verifying Solution Uniqueness in Limited-view CT

A Curvelet based Sinogram Correction Method for Metal Artifact Reduction

Tomographic Reconstruction

Cardiac Dual Energy CT: Technique

Learning Splines for Sparse Tomographic Reconstruction. Elham Sakhaee and Alireza Entezari University of Florida

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Automatic Ascending Aorta Detection in CTA Datasets

Financial disclosure. Onboard imaging modality for IGRT

Few-View CT Reconstruction with Group-Sparsity Regularization

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

A Novel Image Super-resolution Reconstruction Algorithm based on Modified Sparse Representation

7/31/ D Cone-Beam CT: Developments and Applications. Disclosure. Outline. I have received research funding from NIH and Varian Medical System.

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

ECE 8201: Low-dimensional Signal Models for High-dimensional Data Analysis

Self-Calibration of Cone-Beam CT Using 3D-2D Image Registration

A comprehensive study on the relationship between image quality and imaging dose in low-dose cone beam CT

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Automatic Intrinsic Cardiac and Respiratory Gating from Cone-Beam CT Scans of the Thorax Region

Model-Based Respiratory Motion Compensation for Image-Guided Cardiac Interventions

Guided Noise Reduction with Streak Removal for High Speed Flat Detector CT Perfusion

Band-Pass Filter Design by Segmentation in Frequency Domain for Detection of Epithelial Cells in Endomicroscope Images

Sparse Principal Axes Statistical Deformation Models for Respiration Analysis and Classification

Signal Reconstruction from Sparse Representations: An Introdu. Sensing

G Practical Magnetic Resonance Imaging II Sackler Institute of Biomedical Sciences New York University School of Medicine. Compressed Sensing

Free-Breathing Whole-Heart Coronary MRA: Motion Compensation Integrated into 3D Cartesian Compressed Sensing Reconstruction

Utilizing Salient Region Features for 3D Multi-Modality Medical Image Registration

Main Menu. Summary. sampled) f has a sparse representation transform domain S with. in certain. f S x, the relation becomes

Multiscale Blood Vessel Segmentation in Retinal Fundus Images

Compressed Sensing Algorithm for Real-Time Doppler Ultrasound Image Reconstruction

Improvement of Efficiency and Flexibility in Multi-slice Helical CT

Transcription:

Total Variation Regularization Method for 3-D Rotational Coronary Angiography Haibo Wu 1,2, Christopher Rohkohl 1,3, Joachim Hornegger 1,2 1 Pattern Recognition Lab (LME), Department of Computer Science, Friedrich-Aleander-University Erlangen-Nuremberg, Martensstr. 3, 91058 Erlangen, Germany 2 Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Aleander-University Erlangen-Nuremberg, Am Weichselgarten 8, 91058 Erlangen, Germany 3 Siemens AG, Healthcare Sector, Siemensstr. 1, 91301 Forchheim, Germany haibo.wu@informatik.uni-erlangen.de Abstract. 3-D rotational coronary angiography plays an important role in the field of diagnosis and treatment planning of coronary artery disease. Due to the cardiac motion, only limited number of projections can be used to reconstruct coronary arteries for each heart phase, which makes the reconstruction problem ill-posed. To reduce the undersampling artifacts, we apply an iterative method that makes use of total variation regularization. Some different reconstruction algorithms are compared and our method outperforms the others in the eperiments. 1 Introduction Coronary X-ray angiography is a very important imaging method in the field of diagnosis and treatment planning of coronary artery disease. 3-D image information offers great advantage for quantitative analysis of vessel properties. Moreover, the successive 3-D reconstructions can be used to detere the temporal dynamics of the arteries [1]. The projection data for 3-D reconstruction of the coronary arteries reconstruction is acquired on an X-ray C-arm system. Simultaneously, the electrocardiogram (ECG) is recorded. After the ECG gating only few number of projections are available for each cardiac phase, which leads to severe angular undersampling and renders the reconstruction problem ill-posed. In addition, several heart beats occur during the data acquisition which causes the data inconsistency. As a result, the standard reconstruction methods like filtered back projection yield unsatisfactory results with many artifacts. One way of tackling this problem is to first estimate the motion of the arteries and then perform a motion-compensated reconstruction. But it is still a challenging problem to get an accurate motion model, especially for the non-periodic case [2]. According to the theory of compressed sensing [3][4], one can solve the illposed problem by first finding a sparse representation for the images and then applying the L1 norm imization method in the transformed domain. Pan s

2 H. Wu et al. group [5] adopted total variation as the sparsifying transform for reconstruction of static objects. Their method can reduce the undersampling artifacts but they did not investigate the performance of the algorithm for moving objects, e. g. coronary arteries. We apply the total variation regularization method for 3-D rotational coronary angiography. The scheme appears to be robust against both undersampling artifacts and motion artifacts. 2 Materials and Methods In tomography, the goal is to reconstruct an object from line-integral projection data. A discrete version of the projection process can be represented as A = b. (1) here A = (a ij ) is a real m n system matri representing the projection operator, = ( 1,..., n ) is a real vector representing the object, and b = (b 1,..., b m ) is the corresponding projection data. Then the optimization problem can be described as T V s.t. A b 2 2 < α. (2) The inequality constrain is used to describe the data inconsistency which can come from many factors, including the heart motion, system noise, X-ray scatting. Thus, it is impossible to always find an image that is perfectly consistency with the data. As a result, we only require that the image yields the projection data that are within the L2 distance of the actual projection data. T V is the total variation norm, which is the L1 norm of the image gradient [6]. It is well known that the constrained optimization problem (2) can be transformed to an easier unconstrained optimization problem T V + β A b 2 2. (3) The unconstrained optimization problem (3) is still hard to solve due to the high dimensions. The size of the system matri A is usually very large. Large memory should be used to store the matri and a lot of time is needed for computation. To overcome these problems, we apply the forward backward splitting method [6]. The objective function of (3) consists of two conve functions. The idea of the forward backward splitting method is to optimize the two parts of the objective function individually. The algorithm can be described as: Step 1) Do N ART iteration steps of the standard ART. Step 2) Do N T V iteration steps of the gradient descent update for imizing µ T V + v 2 2, (v is calculated from step 1) Step 3) Repeat step1 and step 2 until (t) (t+1) 2 2 is less than a certain value or the maimum iteration number is reached.

Bildverarbeitung fuer die Medizin 2011 3 In order to do a reproducible scientific research, we adopted a dataset with periodic cardiac motion from CAVAREV [7] in our eperiments. The dataset can be downloaded for free. CAVAREV offers an evaluation method but does not provide the ground truth. Thus classical evaluation schemes like MSE (mean squared error) can not be used to evaluate the results. But since the main goal of C-arm CT imaging of highly contrasted cardiac vasculature is to find the size and location of vessels, the evaluation method offered by CAVAREV seems to be more suitable. The method is based on the spatial overlap of the vasculature reconstruction with the ground truth. The Dice similarity coefficient (DSC) is calculated at each projection image with different parameter for the quality assessment [7]. The measure for the reconstruction is the ma value of DSC at all projection images. The DSC value ranges from 0 to 1. The value 0 stands for no spatial overlap while the value 1 stands for a perfect match. To further evaluate, we compared our method to some other reconstruction algorithms: standard ART, ECG-gated FDK, PICCS [8] and L1 imization methods [9]. In the eperiments, we set the gating window to 0.06 s that only 15 projection images were used to do the reconstruction. N ART and N T V was 4 and 10 respectively. µ was chosen as 0.005 and the maimum iteration number was 200. The parameters for the other methods were set as in the referenced paper. 3 Results The reconstructed transaial slices from different methods are listed in Fig. 1. The ma DSC values of the reconstructions from different methods at different heart phases are in Table 1. Due to the angular undersampling, the reconstructions from standard ART and ECG-gated FDK include many streak artifacts. PICCS and L1 imization method reduce the artifacts dramatically. The streak artifacts are nearly invisible in the results of TVR. Table 1 shows that TVR outperforms the other methods at all three different heart phases, since the ma DSC value of TVR is larger than the one of the others. 4 Discussion The PICCS, L1 imization and TVR are optimization based reconstruction methods. The differences between those methods are the regularization terms. From the view of compressed sensing, the regularization terms can be seen as a sparsifying transform. The algorithms just apply the L1 imization method in different domains. A more sparse representation can reduce the number of unknowns (more coefficients are zero or very small.), making the ill-posed problem easier to solve. For coronary arteries, the total variation norm can give a more sparse representation than L1 norm. In the eperiments, the reconstruction results from ECG-gated FDK are used as the prior image which contain many streak artifacts. Thus PICCS may not offer a more sparse representation than

4 H. Wu et al. Table 1. Ma DSC values of different reconstruction methods at different heart phases. High DSC value indicates a high overlap between the ground truth and the reconstruction result. Heart Phase 0% 40% 90% TVR 0.721 0.772 0.785 PICCS 0.595 0.613 0.726 ART 0.510 0.545 0.554 L1 Minimization 0.684 0.723 0.730 ECG-gated FDK 0.484 0.534 0.555 total variation norm. As total variation norm gives the most sparse representation for coronary arteries in the eperiments, our method outperforms the others. Since a more sparse representation of the image can increase the reconstruction quality. Some other representations (wavelet, DCT) will be investigated. 5 Acknowledgments The first and third authors gratefully acknowledge funding of the Erlangen Graduate School in Advanced Optical Technologies (SAOT) by the German Research Foundation (DFG) in the framework of the German ecellence initiative. The first author is financed by Chinese Scholarship Council (CSC). References 1. Hansis E, Schaefer D, Doessel O, Grass M. Evaluation of iterative sparse object reconstruction from few projections for 3-D rotational coronary angiography. IEEE Trans Med Imag. 2008;27(11):1548 55. 2. Schaefer D, Borgert J, Rasche V, Grass M. Motion-compensated and gated cone beam filtered back-projection for 3-D rotational X-ray angiography. IEEE Trans Med Imag. 2006;25(7):898 906. 3. Donoho D. Compressed sensing. IEEE Trans Inf Theory. 2006;52:1289 1306. 4. Candes E, Romberg J, Tao T. Robust uncertainty principles: Eact signal reconstruction from highly incomplete frequency information. IEEE Trans Inf Theory. 2006;52:489 509. 5. Sidky EY, Pan X. Image reconstruction in circular cone-beam computed tomography by constrained, total-variation imization. Phys Med Bio. 2008;53:4777 4807. 6. Jia X, Lou Y, Li R, Song W, Jiang S. GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variation. Med Phys. 2010;37:3441 3447. 7. Rohkohl C, Lauritsch G, Keil A, Hornegger J. CAVAREV - An open platform for evaluating 3D and 4D cardiac vasculature reconstruction. Med Phys. 2010;55:2905 2915. 8. Chen G, Tang J, Leng S. Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. Phys Med Bio. 2008;55:660 663.

Bildverarbeitung fuer die Medizin 2011 5 9. Li M, Kudo H, Hu J, Johnson R. Improved iterative algorithm for sparse object reconstruction and its performance evaluation with micro-ct data. IEEE Trans Nucl Sci. 2004;51:659 666. Fig. 1. Reconstructed transaial slices from different methods. The streak artifacts are nearly invisible in the slices from TVR.