Ignitron Driver Manual (N = cable length in meters -example IG5F2-10 = unit with a 10 meter cable length)

Similar documents
PDD-300 pulsed diode driver

MV SERIES MACHINE VISION STROBOSCOPE. Operating Manual

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

LPI SG + SST Spark Gap Surge Filter

LPI SG + SS480 Spark Gap Surge Filters

CCPF-3500-XX OPERATION MANUAL. Lumina P/N

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Rugged MediaConverter

DIN Molded Cable Assemblies

********SERVICE MANUAL******** MODELS:

AIR COOLED MODULAR RECTIFIER

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

CUS150M1 Instruction Manual

EFE300 / EFE400 EFE300M / EFE400M

EFE300 / EFE400 EFE300M / EFE400M

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Technical Data Sheet Medium Current Power Surge Filters

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION

Series Watt DC Power Supplies

CCPF-500 OPERATION MANUAL. Lumina P/N

RT4F-120V/20A-WAC RECTIFIER

ADVANCED MICRO SYSTEMS

DP-PS Laboratory Diode Driver (For use with MK-11, 81, 82, 85, & 88 lasers)

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

SAMPLE. MOVs are sometimes referred

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

HV-CS kv Edge Mount Triaxial Jack

Redundancy unit CP-A RU

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Safety Standards. Model Number:

LPI SST Surge Filters

PRODUCT. Battery Charger

DIRECTED ENERGY, INC. PCX AMP PULSED CURRENT SOURCE OPERATION MANUAL VERSION February 2010

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Copyright 2014, R. Eckweiler & OCARC, Inc. Page 1 of 6

RT12-240V/2.4kW Rectifier Specification

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Line Impedance Stabilization Network (LISN)

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Safety Standards. Model Number:

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Safety Standards. Model Number:

LAMBDA EMI 405 ESSEX ROAD, NEPTUNE, NJ 07753

SureTest Model ST 1D Instructions

Features. Applications and Benefits TRC ELECTRONICS, INC

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

ATE QUICK START GUIDE. KEPCO An ISO 9001 Company. VOLTAGE/CURRENT STABILIZED POWER SUPPLY I INTRODUCTION

PHOENIX CONTACT - 07/2006

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Mini Digital Multimeter

WORLD LEADING PRODUCTS FOR LASER SCIENTISTS AND ENGINEERS

Technical Manual SMART TRAC PS Card

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

SIRIUS 200 U1X200A SRS U1X200A SRS USER S MANUAL

Power Supply (48Vdc, 2.5A)

Model 500 Series Laser Diode Driver User's Manual

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

RT4B-110V/12A RECTIFIER

Safety Standards. Model Number:

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Mini Digital Multimeter

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

G SERIES ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS

700 Series 200 Amp Clamp Meters

A. Advanced Features. Configurable High Power Solution

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

Data Sheet 1SD536F2-MG1200FXF1US53 Single-Channel SCALE Plug-and-Play IGBT Driver

Residual overvoltage relay

OPERATING INSTRUCTION

Safety Standards. Model Number: Unit Weight:

Gelo LED Driver 100W, Single output RGLD100-24

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

RClamp TM 0504M RailClamp Low Capacitance TVS Diode Array PRELIMINARY Features

C1U-W Tx Series

INSTRUCTION MANUAL MODEL 8515D DEMAGNETIZER

LED Driver Linear / area fixed output

Instruction leaflet for the VPAK DC TO HVDC CONVERTER (1kV to 10kV)

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

RT4F-48V/50A-WAC RECTIFIER

BIPOLAR OPERATIONAL POWER SUPPLY

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

LED Driver Linear / area fixed output

PRO-1250D CT MID DIN rail three phase four wire energy meter.

2 in 1 LAN Tester and Multimeter Model:

Autoranging True RMS Multimeter User Manual

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Power supply CP-C 24/5.0

RTU500 series Data Sheet Power Supply CP-E 24/2.5

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

LED Driver Linear / area fixed output

Transcription:

North Star High Voltage 12604 N New Reflection Dr, Marana, AZ 85653 520 780 9030; (206)219-4205 FAX www.highvoltageprobes.com DANGER - Voltages of up to 2.5 kv are generated by this unit Ignitron circuits to which this is connnected my have even higher voltages. Disconnect from ignitron and external HV before servicing. IG5F2- N Ignitron Driver Manual (N = cable length in meters -example IG5F2-10 = unit with a 10 meter cable length) Serial Number Test V open Test I short w/protection: Test I Short w/o protection: Life Test start Life Test finish Serial Number Phone 520 615 4856 FAX 206 219 4856 e-mail: Radler2@Compuserve.com web www.highvoltageprobes.com

1. General The IG5F2-10 Ignitron driver is designed to meet the specifications for triggering all ignitrons. It also provides a trigger isolation capability of 25 kv. It s specifications are: Stored Energy: Open Circuit Voltage: Current: AC Input Voltage: Input Pulse: Input Pulse Duration: Output Voltage Isolation: Fuse: 3.6 Joule at 1.0 Hz.; 3 J at 2 Hz. 1.80 kv at 1.0 Hz. 370 A output into typical ignitron ignitor (1 Hz.) (Protection network not in use) 100-125 VAC input or 200-250 VAC input using internal slide switch. Failure to set the unit properly when using the higher voltage will destroy the unit. 5 V/20 ma if fiber optic transmitter accessory board is used Note that most 10 ma sources will drive a 3 m cable. 3-100 usec (Triggers on rising edge) 25 kv to the input voltage 1/8 A internal - 220 VAC; 1/4A internal 110 VAC Supplied Fiber: 10 m. standard HP/Agilent Versatile Fiber Type Trigger Delay: Status Indicators: Storage Temperature: Operating Temperature 1200 ns. Typical TRIG TEST (See figures for TRIG TEST output characteristics) PS STATUS -20 C - 45 C 5C - 40 C 2

2.0 Installation Connect a versatile fiber trigger signal to the input fiber optic. The BNC/fiber adapter may be used to supply the trigger to the unit by applying a 5-15 V pulse to the BNC. TTL signals which meet typical TTL requirements will trigger the unit (5 V, 5 ma). Connect the output marked Ignitor to the Ignitor pin, and connect the output marked Cathode to the cathode. These connections should be secure and capable of conducting 400 A pulsed. The accessory board has components which help protect the unit against certain failures of the ignitron itself. The accessory board should be placed near the cathode, and it should not be grounded. Open the unit and check the internal switch to assure that the power is set to the type of power line you plan to use. If the internal power switch is not set correctly the unit may fail. The factory setting is always for 220 VAC. Connect the input power (220 VAC nominal or 110 VAC nominal) to the AC receptacle once the settings of both switches are assured. If a powered trigger module has been supplied, check the settings of that unit before use. Pulse the unit. Check the connections without HV applied to the ignitron to make sure that the contacts are not arcing. The unit will make an audible ticking noise when triggered. 2.1 Fiber optic cable Do not kink the fiber optic cable - try to keep the fiber optic cable radius of curvature >7 cm if possible. 1 mm plastic fiber is used so there is attenuation. 3.0 Mounting A diagram for mounting the unit is appended. Studs used are Metric system M8. The unit may be mounted in any orientation, and the unit itself should be grounded. The accessory board on the fly leads should not be grounded. 4.0 Applications The IG5-F is an ignitron driver supplied with the capability for isolation of the output. For circuits where the cathode is floating, such as series ignitron applications, the circuit can derive power from the external circuit: Circuit A Recommended Wherever Possible In circuit A, the cathode of the ignitron is grounded. If this circuit can be used, cooling of the ignitron jacket is simplified, along with triggering and monitoring. The unit power 3

A) Cathode Grounded B) Anode Grounded +V In Ignitron Ignitron Cathode IG5-F In. Volt Switches Cathode IG5-F In. Volt Switches Ignitor 3 IEC 2 1 -V In Limited to 25 kv Ignitor 3 IEC 2 1 Fiber in BNC/Fiber Adapter Fiber in BNC/Fiber Adapter C) No Ground - PowerFromACLines -V In Limited to 25 kv Ignitron Cathode IG5-F Ignitor In. Volt Switches 3 IEC 2 1 +V In Limited to 25 kv BNC/Fiber Adapter Fiber in Figure 1 Application scenarios. The metal box should always be grounded. is connected to line voltage, the fiber is inserted into the driver, and the unit triggers with each light pulse. The input power ground should be grounded (IEC plug and chassis ground). Circuit B Lower Value Biases In circuit B, the cathode of the ignitron is at some potential up to 25 kv from ground. If this circuit can be used, heating of the anode insulator is simplified, along with triggering and monitoring. The unit power is connected to line voltage, the fiber is inserted into the driver, and the unit triggers with each light pulse. An MOV of appropriate voltage connected from either of the line voltages (preferably neutral if such exists) to the preferred earth ground may be desirable. No voltage can exceed 25 kv relative to ground. The input power ground should be grounded (IEC plug and chassis ground). Circuit C Floating Ignitron Powered by AC In circuit C the circuit derives it s power from AC voltage, but neither the cathode or anode is grounded. The voltage difference between the cathode/ignitor and anode must not exceed the 25 kv including during transients. No voltage can exceed 25 kv relative to ground. 4

5.0 Grounding The box is designed for grounded operation. If floating operation is necessary, the signal source and power source must be floated to the same potential. The difference between the power voltage and the box voltage should not exceed 700 V peak. 6.0 Power Supply Voltage Monitor The monitor labeled PS Status has an output when the power supply driving the SCR is ready. This will fail to light if the 600 V internal power supply or SCR fails. 7.0 Output Protection Board An accessory consisting of an 8 kv diode, and 3 kv spark gap is provided on all boards. This accessory prevents positive voltages of greater than 3 kv from being applied to the trigger unit. Negative voltages are protected by diodes in the unit itself. Such voltages are sometimes applied to the ignitor during a ringing discharge. The current output is reduced by about 50 A when this board is in use. If this is undesirable for a given application, then the board need not be used. The fly leads can be cut and stripped for use without this board. Use of this board is optional, but removing this board will make the unit more sensitive to certain failures of the ignitron itself. Removal of the board may void the warranty if certain types of failures occur. The board should either be floating or at the same potential as the Ignitron Cathode. The board only protects against fault modes associated with positive anode/negative cathode (standard) operation of the ignitron. In the non-standard oscillatory mode which is sometimes used, the driver can be subjected to the full power of the capacitor bank. The driver is not protected against an arc between anode and the ignitor. 5

8.0 Warranty The unit is warrantied for 1 year against defects in manufacturing and most failures. If warranty service is requested the type of ignitron, ignitron/capacitor bank circuit schematic, and any other relevant information must be supplied. The unit is not warrantied for oscillatory current applications where the current through the ignitron reverses. 6

Figure of TRIG TEST output characteristic Fig. 2 Short Circuit Monitor and Current. Figure 2 shows the current in the output along with the monitor output for the case where the ignitron ignitor fires immediately. The monitor is on for 10-15 microseconds and it s main pulse starts within 2 microseconds of trigger initiation. This corresponds to nominally good performance. Figure 3 shows the open circuit/open ignitor case. A pulse after saturation of the transformer, delayed by approximately 5 microseconds. In most situations, the pulse should appear in 4 microseconds or less time after initiation of the pulse from the fiber. Fig. 3 monitor and open circuit voltage 7

SPECIFICATIONS IG5F2-10 The IG5F2-10 Ignitron driver is designed to meet the specifications for triggering all ignitrons. It also provides a trigger isolation capability of 25 kv. It s specifications are: Stored Energy: Open Circuit Voltage: Current: AC Input Voltage: Input Pulse: Input Pulse Duration: Output Voltage Isolation: Fuse: 3.6 Joule at 1.0 Hz.; 3 J at 2 Hz. 1.80 kv at 1.0 Hz. 370 A output into typical ignitron ignitor (1 Hz.) (Protection network not in use) 100-125 VAC input or 200-250 VAC input using internal slide switch. Failure to set the unit properly when using the higher voltage will destroy the unit. 5 V/20 ma if fiber optic transmitter accessory board is used Note that most 10 ma sources will drive a 3 m cable. 3-100 usec (Triggers on rising edge) 25 kv to the input voltage 1/8 A internal - 220 VAC; 1/4A internal 110 VAC Supplied Fiber: 10 m. standard HP/Agilent Versatile Fiber Type Trigger Delay: Status Indicators: Storage Temperature: Operating Temperature 1200 ns. Typical TRIG TEST (See figures for TRIG TEST output characteristics) PS STATUS -20 C - 45 C 5C - 40 C 8