Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Similar documents
Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

T EN TROVIS Electropneumatic Positioner

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Electric Actuators with Process Controllers

Series 3730 Type Electropneumatic Positioner

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Automation System TROVIS 5400 District Heating Controller TROVIS 5476

TROVIS-VIEW software TROVIS 6661

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Series 3730 Electropneumatic Positioner Type

Indicomp 4 Bargraph Indicator

JUMO Quantum PID100/PID200/PID300

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

T 9510 EN Media 7 Differential Pressure Meter with remote data transmission

Automation System TROVIS 5400 District Heating Controller TROVIS 5475

Compact Universal Controllers

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Configuration Manual KH EN. TROVIS Electric Actuator with Process Controller. for heating and cooling applications

Precision thermometer Model CTR5000

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Safety Temperature Limiter TT-STL 50

I/O module, universal, digital, S0 inputs, modu533

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

PROFIBUS-PA Positioner Type 3785

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Compact universal controllers

Published by and copyright 2015 Siemens AG Energy Management Freyeslebenstr Erlangen, Germany

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Electronic Control Unit RC

MINI MCR-SL-PT100-UI(-SP)(-NC)

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

02/11/2015

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

itemp TMT180 Technical information

DIGITAL INDICATING CONTROLLER

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

I/O module, digital and universal inputs, modu530

Alarm Unit DG 3200 Control And Monitor Standard Signals

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Display and Monitoing Units

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Universal counter UZ 9648 Counting - length measurement - metering - positioning

VariTrans P Standard-Signal Isolators

AI531 Analog Input Module

SX90 Process Controller

JUMO diraview 104/108/116/132

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Super universal modules

Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

DC561, digital input/output module,

JUMO ctron 04/08/16 Compact controller with timer and ramp function

Series 3730 Type Electropneumatic Positioner

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

Controller. Application Example Climate chambers, dryer, heat threating plants, sterilisers, packing machines, food application, laboratory

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Portable Multi-Function Calibrator Model CEP6000

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

Zelio Control-modular measurement and control relays 1

MINI MCR-SL-UI-2I(-SP)(-NC)

DRTS 33. The new generation of advanced three phase relay test set

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

DC562, digital input/output module,

MCX08M2 Programmable controller

Datasheet - SRB 301LC/B-24V

Product data sheet accessories control and regulation Accessories AIRWIN

Programmable Relay ZEN V2 Units

LineMaster 200. Continuous-line Recorder. ABB Instrumentation 10/ EN

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

QUINT-PS/ 1AC/24DC/ 5

LAUREL ELECTRONICS, INC.

LineMaster 100 Continuous-line Recorder

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

Limit switches for Dial Thermometers and Pressure gauges

Operating instructions. Speed monitor D / / 2014

Data Sheet T EN

IST ULTRASTAB Power Supply for high precision transducers

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

MIC-2 Multi-instrument DATA SHEET

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

PHOENIX CONTACT - 01/2007

Contact protection relay

Transcription:

Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general and more complex control tasks. Suitable for control of continuous, on/off or pulsing final control elements (pneumatic actuators with i/p positioners, additional electric actuators, electric heating systems, refrigerating machines etc.) By setting the functions and parameters, the controller can be adapted to a control task quickly. The controller settings are saved in a non-volatile memory, even when the power supply fails. Electronics from SAMSON Special features Configuration using the controller keys or the TROVIS- VIEW 4 software Two analog inputs with filtering, root extraction, function generation and signal monitoring One binary input with selectable function Two relay s for on/off or three-step or limit alarms One transistor for fault alarms Infrared interface for configuration Plug-on screw terminals Degree of protection (front) IP 65 Two internal set points and one external set point (fixed set point control and follow-up control) Set point ramp and ramp Control signal limitation Linking of input variables (addition, subtraction) Operation with code number or control key locking by binary input Fig. 1: TROVIS 6493 Compact Controller SAMSON AKTIENGESELLSCHAFT Weismüllerstraße 3 60314 Frankfurt am Main, Germany Phone: 49 69 4009-0 Fax: 49 69 4009-1507 samson@samson.de www.samson.de Edition July 2015

Inputs and s (Fig. 2) Two analog inputs One input is used for the controlled variable. The second input can be used for the external set point, disturbance variable, position feedback of an actuator or as an input for differential control. Both inputs can be configured as: 0 to 20 ma, 4 to 20 ma 0 to 10 V, 2 to 10 V Resistance thermometers Pt 100, Pt 1000, Ni 100, Ni 1000 Potentiometer 1 kω One binary input The binary input is activated by a voltage signal (4 to 31 V DC) and can be used as follows: Activation of the constant value (e.g. for enabling control) Set point switchover Start the set point ramp or ramp Manual/automatic switchover Locking the control signal Activatation of the relay s Control key locking One analog The controller is issued at the analog by default. Optionally, an input signal (e.g. controlled variable, external set point) or error signal can be issued. The can be configured as: 0 to 20 ma, 4 to 20 ma 0 to 10 V, 2 to 10 V Two relay s The relays are double-throw contacts and can be used either as on/off s, three-step s or for status and limit alarms. One transistor The isolated transistor issues the collective fault alarm. If an internal fault exists or the configured signal monitoring of the inputs responds, the externally connected voltage signal (3 to 50 V DC, max. 30 ma) is generated. One supply The supply can be used to supply a voltage (20 V DC, max. 45 ma) to either a two-wire transmittter or the binary input. Analog inputs Binary input ma, V Pt 100 Pt 1000 Ni 100 Ni 1000 Pot. 1 k IN 1 IN 2 BI 1 TROVIS 6493 Y ma, V BO 1 BO 2 ON/OFF Analog Relay s PWM Limit alarms 3-step 3-step PWM On/off or three-step Interface TROVIS- VIEW IR Transistor BO 3 Fault alarm Supply voltage Supply Fig. 2: Wiring diagram (inputs and s) 2 T 6493 EN

Operation (Fig. 3) The controller is operated using six keys whose functions depend on the selected level. 1 Operating level After the compact controller is switched on, it runs in automatic mode. The display shows the operating level with the controlled variable and set point readings. The selector key (8) can be used to switch the reading on the bottom row of the display (2): internal set point W or W2, external set point WE, manipulated variable Y or error signal Xd%. The internal set points W and W2 can be changed by pressing the cursor keys (4 and 5). Xd% W 2 Setup and parameter levels Press the enter key (7) to access the setup and parameter levels. In these levels, the compact controller is adapted to its control task by configuring the functions and setting the parameters. The functions are arranged in hierarchical levels. The cursor keys (4 and 5) are used to navigate to levels, sublevels, functions and parameters and the enter key (7) to open them. Changes to settings are confirmed by pressing the enter key (7). The user can return at any time to the next level by pressing the escape key (6). The functions blocks, parameters and calibration values can be protected by a key code against unauthorized access. TROVIS-VIEW 4 Software The infrared interface (Fig. 4) at the front allows the compact controller to be configured and operated using SAMSON's TROVIS-VIEW 4 software installed on a computer. The TROVIS-VIEW software can be downloaded free of charge from our website (u www.samson.de > Services > Software > TROVIS-VIEW). The software can also be supplied on a CD-ROM on request (order no. 6661, configuration ID 2938759). Refer to the Data Sheet u T 6661 for details on the system requirements. The compact controller can communicate with a PC over its infrared interface on the front of the controller next to the yellow enter key. An infrared adapter (order no. 8864-0900) is required for data transmission between the serial RS-232 interface on the PC and infrared interface on the controller. A bracket (order no. 1400-9769) ensures that the adapter is properly aligned in front of the controller. The infrared adapter can be connected to the USB port of the computer using the USB/RS-232 adapter (order no. 8812-2001). 8 9 7 6 1 Label (exchangeable) 2 Display 3 Manual/automatic key 4 Cursor key (increase, scroll forwards) Fig. 3: Operation 5 Cursor key (decrease, scroll backwards) 6 Escape key 7 Enter key 8 Selector key 9 Infrared interface 3 4 5 Bracket (order no. 1400-9769) Infrared adapter (order no. 8864-0900) Connector to RS- 232 port of a PC Fig. 4: Connecting an infrared adapter Technical data T 6493 EN 3

Inputs Analog input IN1 Analog input IN2 Two analog inputs, optionally for controlled variable X or external set point WE 0/4 to 20 ma or 0/2 to 10 V, resistance thermometer Pt 100, Pt 1000, Ni 100, Ni 1000 or potentiometer 1 kω Input for current and Signal range 0/4 to 20 ma or 0/2 to 10 V voltage Maximum permissible values Current ±50 ma, voltage ±25 V Internal resistance Current R i = 50 Ω, voltage R i = 20 kω Permissible common mode 0 to 5 V voltage Error Zero < 0.2 %, span < 0.2 %, linearity < 0.2 % Temperature influence < 0.1 %/10 K for zero and span (based on 20 C) Resolution < 0.0024 ma (< 0.012 % with 0 to 20 ma) (< 0.015 % with 4 to 20 ma) < 1.2 mv (< 0.012 % with 0 to 10 V) Transmitter supply Acc. to DIN IEC 381 (NAMUR NE 06) 20 V DC, max. 45 ma, resistant to short circuiting Resistance thermometer For sensor Pt 100, Pt 1000 acc. to DIN EN 60751 Ni 100, Ni 1000 acc. to DIN 43760 Nominal measuring range Pt 100, Pt 1000: 100 to 500 C Ni 100, Ni 1000: 60 to 250 C Wire resistance Three-wire R L1 = R L2 = R L3 < 15 Ω Error Zero < 0.2 %, span < 0.2 %, linearity < 0.2 % Pt 100, Pt 1000 (in the range Zero < 0.1 %, span < 0.1 %, linearity < 0.1 % between 40 and 150 C) Temperature influence < 0.2 %/10 K for zero and span (based on 20 C) Resolution < 0.04 C (< 0.007 % at 100 to 500 C) Potentiometer Nominal value 1 kω, three-wire Wire resistance R L < 15 Ω per wire Error Zero < 0.2 %, span < 0.2 % Temperature influence Zero < 0.1%/10 K, span < 0.2 %/10 K (based on 20 C) Resolution < 0.07 (< 0.007 %) Binary input Switching contact with external supply 24 V DC (4 to 31 V DC) or powered by the controller over terminals 14, 15 (20 V DC) Signal state OFF with 0 to 2 V Signal state ON with 4 to 31 V Current consumption < 6.0 ma with 24 V DC < 5.5 ma with 20 V DC Outputs Continuous-action, on/off or three-step Analog Signal range 0(4) to 20 ma; load < 740 Ω 0(2) to 10 V; load > 3 kω Maximum modulation range 0 to 22 ma, 0 to 11 V Error < 0.2 % Temperature influence Zero < 0.1%/10 K, span < 0.1 %/10 K Resolution < 0.0015 ma (< 0.0075 % with 0 to 20 ma) (< 0.0094 % with 4 to 20 ma) < 0.75 mv (< 0.0075 % with 0 to 10 V) Binary BO1 Binary BO2 Two relays with floating switching contact, max. 250 V AC, max. 250 V DC, max. 1 A AC, max. 0.1 A DC, cos Q = 1 Spark suppression Connected in series C = 2.2 nf and varistor 300 V AC, in parallel to each relay contact Binary BO3 for fault alarms Isolated transistor, external supply 3 to 50 V DC, max. 30 ma 4 T 6493 EN

Infrared interface Transmission protocol Transmission rate Angle of reflected beam 50 Distance IR adapter controller General specifications Display Reading range Configuration Supply voltage Power consumption Temperature Mechanical environmental testing for storage, transportation and operation Sinusoidal vibrations acc. to IEC 60068-2-6 Random vibrations acc. to IEC 60068-2-64 Shocks acc. to IEC 60068-2- 27 SAMSON-specific protocol (SSP) 9600 bit/s Max. 0.7 m Backlit LCD 999 to 9999; start value, end value and decimal separator can be adjusted Functions saved in read-only memory for fixed set point and follow-up control, one control circuit 90 to 250 V AC; 47 to 63 Hz 24 V AC/DC (20 to 30 V AC/DC), 47 to 63 Hz 13 VA (90 to 250 V AC), external fuse > 630 ma (slow) 7 VA (24 V AC/DC), external fuse > 1.25 A (slow) 0 to 50 C (ambient) 20 C to 70 C (storage and transport) 2 to 9 Hz; amplitude 3.5 mm 9 to 200 Hz; acceleration 10 m/s² 200 to 500 Hz; acceleration 15 m/s² 1.0 m²/s³; 10 to 200 Hz 0.3 m²/s³; 200 to 2000 Hz Acceleration 100 m/s²; duration 11 ms Degree of protection IP 65 (front), IP 30 (housing), IP 00 (terminals) according to EN 60529 Device safety Acc. to EN 61010-1: Protection class II Overvoltage category II Degree of contamination 2 Design and testing according to EN 61010 Electromagnetic compatibility Requirements according to EN 61000-6-2, EN 61000-6-3 and EN 61326-1 Electrical connection 1.5 mm² screw terminals Scanning time 80 ms Weight Approx. 0.5 kg Compliance Dimensions in mm (inch) Panel cut-out 45 0.6 x 92 0.8 (1.77 0.023 x 3.622 0.0315 ) 48 (1.89) 10 158 (6.18) 142 (5.59) 96 (3.78) 91,5 (3.60) Fig. 5: Dimensions in mm (inch) T 6493 EN 5

Electrical connection Analog input IN1 Supply 20 V, max. 45 ma Analog input IN2 Analog Binary input BI1 Binary BO3 11 12 13 14 15 17 19 20 31 32 81 82 83 84 Current 0/4...20 ma 24 V DC Current Two-wire transmitter 4...20 ma 3...50 V DC, max. 30 ma Voltage 0/2...10 V Resistance thermometer Pt 100/Pt 1000 Ni 100/Ni 1000 Three-wire Two-wire ϑ ϑ ϑ ϑ Potentiometer 1000 Ω Three-wire 100 % 0 % 100 % 0 % Two-wire 100 % 0 % 100 % 0 % Supply voltage L N L L/ (90...250 V AC) 24 V AC/DC (20...30 V) N N/ Three-step for electric actuator On/off Binary Limit relay Binary BO1 41 42 43 L L L'() BO1 LIM 1 Binary BO2 51 52 53 N BO2 LIM 2 Fig. 6: Electrical connection Article code Accessories Compact controller TROVIS 6493-032 x Accessories Order no. Supply voltage 90 to 250 V AC 4 24 V AC/DC 5 CD-ROM with TROVIS-VIEW 4 software... 6661, Var.-ID 2938759 Infrared adapter (RS-232)... 8864-0900 Bracket for infrared adapter... 1400-9769 USB/RS-232 adapter... 8812-2001 6 T 6493 EN

T 6493 EN 7

Specifications subject to change without notice T 6493 EN 2018-05-24 English