Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Similar documents
Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data sheet. Technical data

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Power consumption In operation At rest For wire sizing

Functional data Factory settings Variable Setting Torque Inhibiting torque

s Spring return C / max C

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Technical data sheets

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Brief description. Type overview

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data

Brief description. Type overview

Technical data. PRCA-BAC-S2-T en-gb subject to changes 1

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Products no longer available

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V

Products no longer available

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

VAV system solution for non-pressure dependent applications in enclosed spaces

Brief description. Service tool ZTH, PC-Tool service socket: locally pluggable or via PP connection.

Technical data. Safety notes. Product features

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Technical data sheet

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Belimo Gateway MP to Modbus RTU - UK24MOD

A CLOSER LOOK. Electronic Fail-Safe Series Direct Coupled Actuators. The Belimo Difference. Brushless DC Motor for Added Accuracy and Controllability

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

Belimo Gateway MP to Modbus RTU - UK24MOD

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Installation VAV-Compact Retrofit Set

Air Damper Actuators Modbus RTU

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

BUS. Adaptive control system for pressure applications (STP) Table of contents

Air Damper Actuators Modbus RTU

VAV Compact Controller Modbus RTU

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

VAV compact controller KNX / PL-Link

VAV compact controller GDB181.1E/3 GLB181.1E/3

InCos-P Pressure sensor 20 Pa Pa

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

ZN230-24MP-1 MP-BUS

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

InReg Volume flow controller Pa

Power consumption motor (motion) 2,5 W Power consumption standby (end position) 1,0 W. Position feedback -

Rotary version, three-position control

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

Compact actuating room automation stations, BACnet/IP, AC24 V (Actuating DXR)

Actuators for CAV control lers

VAV compact controller

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Digital electropneumatic positioner

BUS. Adaptive VAV control system for sensitive working areas. Table of contents

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Minimum 360 in-lb torque - GK. Minimum 54 in-lb torque - NKQ. Minimum 101 lbf - AHQ. Electronic Fail-Safe Series Direct Coupled Actuators

Digital electropneumatic positioner SideControl

Super universal modules

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

I/O module, universal, digital, S0 inputs, modu533

Air damper actuators

RA Electric Rotary Actuator 20 Nm to 60 Nm for butterfly valves

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

Rotary actuators for ball valves

EC centrifugal module - RadiPac

Digital electropneumatic Positioner SideControl

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Universal Controller

Installation instructions Inclination sensor EC2019 EC / / 2013

ASI Systems ML5740A Series

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

SIMOCODE 3UF Motor Management and Control Devices

Digital input modules

RXTH DUAL ROOM SENSOR / SWITCH

EY-EM : Remote I/O module, ecolink

Rotary actuator for ball valves KNX / PL-Link

Transcription:

echnical data sheet NM24A-MOD Communicative damper actuator for adjusting dampers in technical building installations orque motor 10 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet MS/P, Modbus RU, Belimo-MP-Bus or conventional control echnical data Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency 50/60 Hz Nominal voltage range AC 19.2...28.8 V / DC 21.6...28.8 V Power consumption in operation 3.5 W Power consumption in rest position 1.4 W Power consumption for wire sizing 6 VA Connection supply / control Cable 1 m, 6 x 0.75 mm² Functional data Nominal torque Min. 10 Nm orque variable 25%, 50%, 75% reduced Communicative control BACnet MS/P Modbus RU (ex works) MP-Bus Operating range Y DC 2...10 V Operating range Y variable DC 0.5...10 V Position feedback U DC 2...10 V Position feedback U note Max. 1 ma Position feedback U variable Start point DC 0.5...8 V End point DC 2...10 V Position accuracy ±5% Direction of motion motor selectable with switch 0 / 1 Direction of motion note Y = 0%: At switch position 0 for ccw rotation or 1 for cw rotation, respectively Direction of motion variable electronically reversible Manual override with push-button, can be locked Angle of rotation Max. 95 Angle of rotation note can be limited on both sides with adjustable mechanical end stops Running time motor 150 s / 90 Running time motor variable 43...173 s Adaption setting range manual Adaption setting range variable No action Adaption when switched on Adaption after pushing the gear disengagement button Override control, controllable via bus communication MAX (maximum position) = 100% MIN (minimum position) = 0% ZS (intermediate position) = 50% Override control variable MAX = (MIN 32%)...100% MIN = 0%...(MAX 32%) ZS = MIN...MAX Sound power level Motor 35 db(a) Damper spindle Universal spindle clamp 8...26.7 mm Position indication Mechanically, pluggable Safety Protection class IEC/EN III Safety Extra-Low Voltage (SELV) Protection class UL UL Class 2 Supply Degree of protection IEC/EN IP54 Degree of protection NEMA/UL NEMA 2, UL Enclosure ype 2 EMC CE according to 2014/30/EU Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-14 www.belimo.com NM24A-MOD en-gb 2018-04-26 subject to changes 1

echnical data Safety Certification UL culus according to UL60730-1A, UL60730-2- 14 and CAN/CSA E60730-1:02 Mode of operation ype 1 Rated impulse voltage supply / control 0.8 kv Control pollution degree 3 Ambient temperature -30...50 C Non-operating temperature -40...80 C Ambient humidity Max. 95% r.h., non-condensing Maintenance Maintenance-free Weight Weight 0.92 kg Safety notes! he device must not be used outside the specified field of application, especially not in aircraft or in any other airborne means of transport. Outdoor application: only possible in case that no (sea)water, snow, ice, insolation or aggressive gases interfere directly with the actuator and that is ensured that the ambient conditions remain at any time within the thresholds according to the data sheet. Only authorised specialists may carry out installation. All applicable legal or institutional installation regulations must be complied during installation. he device may only be opened at the manufacturer s site. It does not contain any parts that can be replaced or repaired by the user. Cables must not be removed from the device. o calculate the torque required, the specifications supplied by the damper manufacturers concerning the cross-section, the design, the installation site and the ventilation conditions must be observed. he device contains electrical and electronic components and must not be disposed of as household refuse. All locally valid regulations and requirements must be observed. Product features Mode of operation Converter for sensors Parameterisable actuators Combination analogue - (hybrid mode) Simple direct mounting Manual override Adjustable angle of rotation High functional reliability he actuator is fitted with an integrated interface for BACnet MS/P, Modbus RU and MP-Bus. It receives the digital positioning signal from the control system and returns the current status. Connection option for a sensor (passive, active or with switching contact). In this way, the analogue sensor signal can be easily digitised and transferred to the bus systems BACnet, Modbus or MP-Bus. he factory settings cover the most common applications. Single parameters can be modified with the Belimo Service ools MF-P or ZH EU. he communication parameters of the bus systems (address, baud rate etc.) are set with the ZH EU. Pressing the Address button on the actuator while connecting the supply voltage, resets the communication parameters to the factory setting. Quick addressing: he BACnet and Modbus address can alternatively be set using the buttons on the actuator and selecting 1 to 16. he value selected is added to the «Basic address» parameter and results in the effective BACnet and Modbus address. With conventional control by means of an analogue positioning signal, BACnet or Modbus can be used for the position feedback Simple direct mounting on the damper spindle with an universal spindle clamp, supplied with an anti-rotation device to prevent the actuator from rotating. Manual override with push-button possible (the gear is disengaged for as long as the button is pressed or remains locked). Adjustable angle of rotation with mechanical end stops. he actuator is overload protected, requires no limit switches and automatically stops when the end stop is reached. 2 NM24A-MOD en-gb 2018-04-26 subject to changes www.belimo.com

Product features Home position he first time the supply voltage is switched on, i.e. at the time of commissioning, the actuator carries out a synchronisation. he synchronisation is in the home position (0%). he actuator then moves into the position defined by the positioning signal. 0 Y = 0% ccw 1 Y = 0% cw Adaption and synchronisation An adaption can be triggered manually by pressing the Adaption button or with the PC-ool. Both mechanical end stops are detected during the adaption (entire setting range). Automatic synchronisation after pressing the gearbox disengagement button is configured. he synchronisation is in the home position (0%). he actuator then moves into the position defined by the positioning signal. A range of settings can be adapted using the PC-ool (see MF-P documentation) Accessories Description Electrical accessories Auxiliary switch, add-on, 1 x SPD S1A Auxiliary switch, add-on, 2 x SPD S2A Feedback potentiometer 140 Ohm, add-on P140A Feedback potentiometer 140 Ohm, add-on, grey P140A GR Feedback potentiometer 200 Ohm, add-on P200A Feedback potentiometer 500 Ohm, add-on P500A Feedback potentiometer 500 Ohm, add-on, grey P500A GR Feedback potentiometer 1 kohm, add-on P1000A Feedback potentiometer 1 kohm, add-on, grey P1000A GR Feedback potentiometer 2.8 kohm, add-on P2800A Feedback potentiometer 2.8 kohm, add-on, grey P2800A GR Feedback potentiometer 5 kohm, add-on P5000A Feedback potentiometer 5 kohm, add-on, grey P5000A GR Feedback potentiometer 10 kohm, add-on P10000A Feedback potentiometer 10 kohm, add-on, grey P10000A GR Connecting cable 5 m, AB: RJ12 6/6, o ZH EU ZK1-GEN Connection cable 5 m, A: RJ11 6/4, B: Free wire end, o ZH EU ZK2-GEN Description Mechanical accessories Actuator arm, for one-sided spindle clamp K-ENSA AH-25 Shaft extension 240 mm, for damper spindles Ø 8...25 mm or Ø AV8-25 10...25 mm Angled ball joint with M8, suitable for damper crank arm KH8 KG8 Straight ball joint with M8, suitable for damper crank arm KH8 KG10A Damper crank arm, for damper spindles KH8 Spindle clamp, one side for NM..A K-ENMA Spindle clamp, one side for NM..A, SM..A K-ENSA Spindle clamp, reversible for NM..A and LMQ.. K-NA Form fit insert 8x8 mm, for NM..A ZF8-NMA Form fit insert 10x10 mm, for NM..A / SM..A ZF10-NSA Form fit insert 12x12 mm, for NM..A / SM..A ZF12-NSA Form fit insert 15x15 mm, for NM..A / SM..A ZF15-NSA Form fit insert 16x16 mm, for NM..A / SM..A ZF16-NSA Mounting kit for linkage operation, NM..A for flat installation ZG-NMA Anti-rotation mechanism 180 mm Z-ARS180 Base plate extension from NM..A to NM.. Z-NMA Position indication for LM..A, NM..A, SM..A, GM..A Z-PI ype ype www.belimo.com NM24A-MOD en-gb 2018-04-26 subject to changes 3

Accessories Description Service ools Service tool for parametrisable and Belimo actuators / VAV controller and HVAC performance devices Belimo PC-ool, software for adjustments and diagnostics Adapter to Service ool ZH ype ZH EU MF-P MF-C Electrical installation! Wiring diagrams BACnet MS/P / Modbus RU Notes Connection via safety isolating transformer. he wiring of the line for BACnet MS/P / Modbus RU is to be carried out in accordance with applicable RS485 regulations. Modbus / BACnet: Supply and communication are not galvanically isolated. Connect earth signal of the devices with one another. GND D AC/DC 24 V 3 5 6 7 D AC/DC 24 V 3 5 6 7 D Cable colours: 1= black 2 = red 3 = white 5 = orange 6 = pink 7 = grey Signal assignement Modbus: C1 = D = A C2 = = B Connection with passive sensor, e.g. Pt1000, Ni1000, NC D 3 5 6 7 Ni1000 28...98 C 850...1600 Ω 2) MF D P1000 35...155 C 850...1600 Ω 2) NC 10...160 C 1) 200 Ω...60 kω 2) 1) depending on type 2) Resolution 1 Ohm Connection with active sensor, e.g. 0...10 V @ 0...50 C 3 5 6 7 MF D - Possible voltage range: 0...32 V (resolution 30 mv) 4 NM24A-MOD en-gb 2018-04-26 subject to changes www.belimo.com

Electrical installation Connection with switching contact, e.g. Δp monitor p 3 5 6 7 MF D - Requirements for switching contact: he switching contact must be able to accurately switch a current of 16 ma @ 24 V. Modbus RU / BACnet MS/P with analog setpoint (hybrid mode) GND Y U DC (0)2 10 V DC 2 10 V 3 5 6 7 AC/DC 24 V Operation on the MP-Bus Y U Sensor MP 3 5 6 7 MF www.belimo.com NM24A-MOD en-gb 2018-04-26 subject to changes 5

Operating controls and indicators 4 0 1 1 Adaption 2 Power Address 3 Status 5 1 Direction of rotation switch Switch over: Direction of rotation changes 2 Push-button and LED display green Off: No power supply or malfuntion On: In operation Flashing: In address mode: Pulses according to set address (1...16) When starting: Reset to factory setting (Communication) Press button: In standard mode: riggers angle of rotation adaptation In address mode: Confi rmation of set address (1...16) 3 Push-button and LED display yellow Off: On: Flickering: Press button: Standard mode Adaptation or synchronising process active or actuator in address mode (LED display green fl ashing) BACnet / Modbus communication active In operation (>3 s): Switch address mode on and off In address mode: Address setting by pressing several times When starting (>5 s): Reset to factory setting (Communication) 4 Gear disengagement button Press button: Gear disengages, motor stops, manual override possible Release button: Gear engages, synchronisation starts, followed by standard mode 5 Service plug For connecting parameterisation and service tools Check power supply connection 2 Off and 3 On Possiple wiring error in power supply Service Quick adressing Service ools connection 1. Press the Address button until the green Power LED is no longer illuminated. LED flashes in accordance with the previously set address. 2. Set the address by pressing the Address button the corresponding number of times (1-16). 3. he green LED flashes in accordance with address that has been entered (1-16). If the address is not correct, then this can be reset in accordance with Step 2. 4. Confirm the address setting by pressing the green Adaption button. If no confirmation occurs for 60 seconds, then the address procedure is ended. Any address change that has already been started will be discarded. he resulting BACnet MS/P and Modbus RU address is made up of the set basic address plus the short address (e.g. 1007=107). he actuator can be parameterised by ZH EU via the service socket. For an extended parameterisation the PC tool can be connected. AC 24 V DC 24 V 3 5 6 7 MP USB ZH EU i esc OK BELIMO PC-ool MF D USB 6 NM24A-MOD en-gb 2018-04-26 subject to changes www.belimo.com

Dimensions [mm] Spindle length Dimensional drawings L Min. 40 Min. 20 52 62 124 8...26.7 8 26.7 * 8...20 8 20 *Option: Spindle clamp mounted below (accessories K-NA needed) 80 25 121 41 Further documentation ool connections Description Protocol Implementation Conformance Statement PICS Description Modbus register Overview MP Cooperation Partners MP Glossary Introduction to MP-Bus echnology www.belimo.com NM24A-MOD en-gb 2018-04-26 subject to changes 7