ReFlx 100 PLUS COLLISION AVOIDANCE SYSTEM

Similar documents
ReFlx. ReFlx 100 Collision Avoidance System Instruction Manual Page 1 6/30/99

Universal Safety Photo Eye UL MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

8000 Series: Installation Supplement R2-1-12

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Appendix E: Edge Ti. Overview. Appendix E: Edge Ti 169

MLV41 Series Miniature Sensors

General-Purpose Photoelectric Sensor

Lighting PowerPincher Installation Instructions

Series 28 Universal Sensors

0,25 mm false pulse suppression 4 program options 4 program options on/off switchable 4 preset levels or level set by customer.

Slot Style Photoelectric Sensors

Suitable for detecting transparent films or transparent bottles

Diffuse reflection light scanner with background suppression. Dimensioned drawing

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

Energetic diffuse reflection light scanner. Dimensioned drawing

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

PRODUCT INFORMATION. G6 Global Sensor. Beyond the standard Global sensor the economic way to business class

Photoelectric Sensor

Safety Control Relay Product Catalog

optical sensors through-beam, retro-reflective, dif. reflection sensors 3000 transmitter with test input robust metal housing

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

LC8 CONTROLLER BOARD INSTALLATION AND MAINTENANCE MANUAL (IMM) p/n 52280T rev 11/08/05

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

25 m 5 m 1 m. Part Number Mounting bracket. E39-LU1 Mounting bracket for E39-R1 reflector

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Features. Sensing range 50 mm mm... Type of light. Light source 3) Wave length. Adjustment 2) PL80A.

INSTALLATION INSTRUCTIONS

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

T4HD: Installation Supplement R8.1.13

Photoelectric Sensor with Built-in Amplifier with New Connector Options E3Z

PTC-101 Quick Installation Guide

MLS7A Series. Photoelectric Sensors. Heavy-Duty Retro-Reflective Sensors. Photoelectric MLS7A Series Heavy Duty PEPPERL+FUCHS 529

SLIMBAT2 wireless photocell MANUAL

Retro-reflective photoelectric sensors. Dimensioned drawing. Receiver Transmitter Optical axis LED yellow 90 turning connector. Electrical connection

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

MODEL SIB-V245 / V453

the Interactive Catalog

3RG7 Opto-BERO Photoelectric Proximity Switches

Roof Truss Roller Press, Tables and Jigging

V8-80HS-1 SERIES OF HIGH-SPEED MOTORIZED ZOOM LENSES

Online data sheet VTE18-4P4240 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

Sensors. Compact: S60 Series. Compact: S60 Series. Multifunction Optoelectronic Sensors

ML20 Series Long-Range Miniature Sensors

ParCon and PosCon line sensors

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

C5 Series Stainless Steel Photoelectric

Device manual AS-i PowerSwitch ZB0028 ZB0040

Operating instructions. Speed monitor D / / 2014

ML17 Series Tru-Vue TM Sensors

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

V E1B Snap-in I/O Module

Compact, Low Profile High Rendering, 100% Diffusion

Photoelectric Sensors. Compact. Retro-Reflective. LED Functions

Photoelectric Sensors E3F2

ACORN User Guide For Revision (Aka Acorn_rev3) Updated 1/23/17

DUAL SWITCH CONTROLLER

Ink-Dot Series II Driver

ADVANCED MICRO SYSTEMS

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Operating instructions. Switching amplifier DN0210 DN / / 2015

onlinecomponents.com

ML17 Series Tru-Vue TM Sensors

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

Online data sheet VS/VE18-4P3140 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Flexible Rogowski Coil Integrator Kit with 4-20mA and 0-20mA. User's Manual

Rugged metal housing provides exceptional performance in demanding applications. Product description

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

MaxStepper Serial Step and Direction Pulse Generator. User Manual

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Technical Data Photoelectric Sensors

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

onlinecomponents.com

Capacitive Proximity Sensor E2K-C

Electrical Demand Specification (Reference SOP: )

The SilverNugget is a servo controller/driver for NEMA 34 frame microstep motors.

Online data sheet VL18-4P3140 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

Power Amplifiers for PVH-EDC Pumps

Convergent Reflective Micro Photoelectric Sensor

DRC & MVP Series. Power Amplifiers MVP DRC Friendship Drive, Magnolia, TX Tel.: Fax:

User s manual. Easy Scan XT3 LED

LC3 LIGHTING CONTROLLER OPERATIONS & MAINTENANCE MANUAL 2013 Dec

DC3IOB Revision User Guide Updated 3/29/10. Overview

FE Series Photoelectric Sensors

Electrical connection

APS SCALE SERIES DIMENSIONS

Regenerative Power Module And Common Bus RPM Panels Instruction Manual

igus motion Plastics dryve D3, DC-Motor Control System

Transcription:

100 PLUS COLLISION AVOIDANCE SYSTEM The 100 Plus collision avoidance system is intended for use with bridges and trolleys to prevent collisions or to limit the approach of adjacent bridges or trolleys. The system is designed to be immune to most electrical noise including that which can be created by variable frequency drives and other parasitic interference affecting the reliability of RF based systems. The 100 Plus system is a three channel system. It uses a two channel light sensor, a single channel light sensor, a diamond grade reflective target, and controller containing the power supply and relay outputs. System Includes: 1-RFX100-2 Dual Channel Sensor with 5 meter control cable 1-RFX100-1 Single Channel Sensor with 5 meter control cable 1-ST100-3 Controller 1-2ft. X2ft. (T2X2) Diamond Reflective Target ST100-3 Controller The ST100-3 controller features two 10 amp relays for inter-connection with the crane motion controls. The power supply is normally 120/1/60. The system can be specified in voltages of 220 VAC, 250 VDC, or 350 VDC. ST100-3 Controller RFX 100-2 Sensor The RFX 100-2 sensor has two channels in a single compact housing that can be individually adjusted to a scanning range of 120 feet by using a diamond grade reflective material. The first channel provides a slow-down command or warning signal (horn or light). The second channel is used to provide the primary stop command to the motion control. An infrared LED light source sends a pulsed light that is reflected back when the reflective material comes within the set range (maximum 120 feet). Sensor RFX 100-2 Diamond Grade Reflector The sensor is in the dark switching mode. Meaning, the controlling relay contacts close on power up and will open if there is a loss of power or the diamond grade material is detected. Page 1

RFX100-1 Sensor This sensor is not intended to be a primary stopping sensor but is used to provide a backup safety stop. RFX 100-1 An infrared LED light source sends a pulsed light that is reflected back when the crane or other object comes with the set range. No target is used. Instead, it uses the object to be detected regardless of color and texture surface. The sensor has an adjustable range of 18 inches to 20 feet. 100 Plus Application Guidelines Contactor Control Bridge and trolley motions using reversing contactors for control, rely on the crane s mechanical brakes for stopping. Therefore, the buffer zone (minimum distance to mating crane or obstruction) should be sized to allow for future brake wear. Adjustable Frequency Crane Control Because adjustable frequency drives (AFD) have various programmable stopping options, consideration should be given to these various means when setting up the 100 Plus system. Using the AFD Limit Switch Inputs Most modern AFDs include programmable limit switch input terminals for each direction of travel (Upper Limit 1 & Upper Limit 2), with provision for automatic slow-down. As soon as the bridge reaches the sensing distance for Channel 1, the drive will command the crane to slow down using a separately programmable speed switch frequency and deceleration time. When the bridge reaches the sensing distance for Channel 2 or 3, the drive will decelerate at stop command or provide immediate stop at stop command (see definitions below), depending on how the drive is programmed. The input to the drive from Channel 3 can be run parallel to that of Channel 2, or run to a multi-function input terminal on the AFD. Decelerate at Stop Command Upon receiving a Stop Command from the 100 Plus system, the output frequency of the AFD decreases to near zero at the programmed deceleration ramp; and the brake is commanded to set. See Table I, Bulletin A260.10 for approximate stopping distances at various deceleration times. These stopping distances will be slightly longer when the AFD is programed with an S-Curve ramp. Page 2

Immediate Stop at Stop Command Upon receiving a Stop Command from the 100 Plus system, the AFD base blocks the main output transistors, thereby electrically disconnecting the motor from the AFD, and through the brake interlock, commands the brake to set. In this mode, the crane functions similar to Contactor Control and relies on the crane s mechanical brakes for stopping. Therefore, the buffer zone (minimum distance to mating crane or obstruction) should be sized to allow for future brake wear. NOTE: It may be necessary to re-calibrate the 100 Plus system whenever the deceleration time is changed. Test all motions under worst case scenario before putting crane into operation. Contact Electromotive Systems for applications involving other types of controls or options. Crane to Wall Collision Avoidance RFX100-1 Sensor SD-3 RFX 100-2 Sensor Slow Down Zone Stop Zone T2X2 Target Buffer Zone SD-2 RD SD-1 SD-1 =Sensing Distance for Channel No. 1 SD-2 =Sensing Distance for Channel No. 2 SD-3 =Sensing Distance for Channel No. 3 RD = Distance CL of Crane to Sensor Mounting Guidelines The T2X2 reflector is used as the target for the RFX100-2 sensor. The wall or other object is used as the target for the RFX100-1 sensor. Each sensor shall be mounted horizontally and perpendicular to its respective target, in both the horizontal and vertical planes, with the optical axis parallel to the line of travel, and approximately three (3) feet away from the walls and ceilings. In addition, separate the two sensors by at least three feet on either the vertical or horizontal axis. For outdoor applications, additional protection may be needed to protect the sensors from the elements. Contact Electromotive Systems for application assistance. Page 3

Crane to Crane Collision Avoidance TDA SD-1B RDB SD-2B SL B T2X2 BZ S B RFX100-2 RFX100-1 RFX100-1 RFX100-2 T2X2 Crane A SL A S A BZ SD-2A Crane B RDA SD-1A TDB SD-1A = Sensing Distance for Channel 1 SD-1B = Sensing Distance for Channel 1 SD-2A = Sensing Distance for Channel 2 SD-2B = Sensing Distance for Channel 2 RDA = Dist. - CL of Crane A to Sensor RDB = Dist. - CL of Crane B to Sensor TDA = Dist. - CL of Crane A to Target B TDB = Dist. - CL of Crane B to Target A S A = Stopping Distance For Crane A S B = Stopping Distance For Crane B SL A = Slow-down Distance For Crane A SL B = Slow-down Distance For Crane B BZ = Buffer Zone Mounting Guidelines The T2X2 reflector is used as the target for the RFX100-2 sensor. The adjacent crane is used as the target for the RFX100-1 sensor. Each sensor shall be mounted horizontally and perpendicular to its respective target, in both the horizontal and vertical planes, with the optical axis parallel to the line of travel, and approximately three (3) feet away from the walls and ceilings. In addition, separate the two sensors by at least three feet on either the vertical or horizontal axes. To avoid cross-talk when mounting two or more sensors facing each other, separate them by at least three feet on either the vertical or horizontal axes. When the sensors are mounted on cranes that travel more than 100 feet apart, allow an additional foot of spacing between them for every fraction of 100 feet. For example, if two cranes are separated by 165 feet, allow 3 feet plus 1 foot for the additional 65 feet. Stopping distances should be determined to allow for a buffer zone with both cranes taveling toward each other at maximum velocity. For outdoor applications, additional protection may be needed to protect the sensors from the elements. Contact Electromotive Systems for application assistance. Connecting the RFX 100-2 and RFX 100-1 Sensors to the ST100-3 Controller The shielded connector cables are furnished with a 5 pin Amphenol Mil Spec plug at both ends for the RFX100-2 sensor and with a 6 pin plug at both ends for the RFX100-1 sensor. Plug the 5 pin angled connector into the socket on the RFX 100-2 two channel sensor, and the straight connector into the left hand receptacle on the ST100-3 controller. Plug the cable with straight 6 pin connectors at both ends into the socket of the RFX100-1 sensor and the right hand receptacle on ST100-3. The RFX 100-2 sensor will not operate when plugged into the receptacle for the RFX 100-1 sensor (Channel 3). Page 4

ELECTRICAL INSTALLATION Note: Installation should be performed by qualified personnel only. National Electric Code and local electrical installations requirements and codes should be followed. X1 10 A Relay X2 1 2 3 4 5 6 7 8 9 10 11 12 10 A Relay 24VDC Power Supply 5 Pin receptacle for RFX100-2 Cord Grip/Conduit opening 6 Pin receptacle for for power and control circuits RFX100-1 (used on 100 "Plus" systems only) ST100-3 Controller Terminal Description/Wiring Notes: 1. Terminals 1 & 4 are open with power Off. Upon power-up, the respective relay contacts change state, unless the reflector for that particular scanner is within the set range. The relay contacts will open upon loss of power or if the reflector is within the set range. 2. Terminals 2 & 5 are closed with power Off. Upon power-up, the respective relay contacts change state, unless the reflector for that particular scanner is within the set range. The relay contacts will close upon loss of power or if the reflector is within the set range. 3. The switching contacts for channel 3 are made within the RFX100-1 sensor and wired to terminals 7, 8 and 9. Terminal 7 functions the same as terminals 1 &4. Terminal 8 functions the same as terminals 2 & 5. 4. Terminals 10 & 12 are used for the 120/1/60 input power supply. A grounding lug is furnished on the inside of the enclosure door. Page 5

RFX 100-2 Two Channel Sensor Set-Up Guidelines: Adjustment: Tools required; regular screwdriver, adjustable wrench 1. To adjust the range of the RFX 100-2, look at the face of the sensor (side with optics window and tag). The adjustment for channel 1 is closest to the yellow indicator and the adjustment for channel 2 is closest to the red indicator. 2. Upon powering up the RFX 100-2, the green indicator light should come on and the normally open contacts on the relays in the control enclosure should close. The other indicator lights (red and yellow) should be off, unless the diamond grade reflective material is in the scanning range. If the red or yellow indicator LED is on, turn the corresponding adjustment clockwise until the indicator goes off. If either the red or yellow LED fails to turn off, return the unit. 3. Move the crane so that the diamond grade reflective material in the sensing path is at the Slow Down sensing distance (SD-1). Channel 1 is used to provide a Slow Down command or warning signal(horn or light) to the motion control. Turn the adjustment on Channel 1 counterclockwise until the yellow indicator comes on. Now move the crane so it is 3 to 4 feet further from the face of the target and turn the Channel 1 adjustment clockwise until the yellow indicator just turns off. 4. Channel 2 is used to provide a primary stop command to the motion control. Move the crane so that the diamond grade reflective material in the sensing path is at the stop sensing distance (SD-2). Turn the adjustment on Channel 2 counterclockwise until the red indicator comes on. Now move the crane so it is 3 to 4 feet further from the face of the target and turn the Channel 2 adjustment clockwise until the red indicator just turns off. 5. It may be necessary to re-calibrate the 100 system whenever the deceleration time is changed. Test all motions under worst case scenario before putting crane into operation. WARNING: Detection systems which are not operational cannot stop crane motion or warn about possible collision. Trusting an inoperative device can result in collisions causing severe injury, death or property damage. Avoid sudden stops. The RFX 100-2 two channel system requires that a diamond grade reflective grade material be present and that the reflective properties of this material not be compromised. Page 6

RFX 100-1 Single Channel Sensor Set-Up Guidelines 1 The RFX 100-1 sensor (channel 3) gives the added security of a second sensor which is used to provide a backup stop for channel 2. It does not use the diamond grade material for detection. Instead, it uses the object to be detected regardless of color and texture. It has an adjustable operating range of 18 inches to 20 feet. 2 Upon powering up the RFX 100-1 the green indicator light should come on and the normally open contacts in the sensor should close. The other indicator light should be off, unless the object to be detected is in the scanning range. If the yellow indicator LED is on, turn the corresponding adjustment clockwise until the indicator goes off. Move the crane to the stop sensing distance (same as Channel 2) and turn the adjustment until this yellow LED comes on. Now move the crane 3 to 4 feet away from the object to be detected (wall or adjacent crane) and turn the Channel 3 adjustment clockwise until the yellow indicator just turns off. 3. Channel 3 should be set at the same sensing range as channel 2. Page 7

RFX 100-2 Two Channel Sensor Technical Data: Scanning Range: To 120 feet per channel with a square diamond grade reflective material. Light Beam: Modulated infrared Transmitter: IRED Receiver: Photo-diode RFX 100-2 Sensor Minimum Input Pulse Duration: 30ms Switching Frequency: 10/s Current Consumption: 100mA max., no load Output: One 10 Amp SPDT relay per channel Switching Mode: Dark switching Output Indicators: Red indicates function of channel 2, Yellow indicates function of channel 1 Supply Voltage Indicator: Green LED, lit when supply voltage is applied Test Input: Available on request Test Input Current Consumption: 5mA max. Housing: Makrolon, black ribbed Protection Category: IP 60, DIN 400 50 Optical Surface: Glass plate Type Connection: 5 meter cable with 5 pin Amphenol Mil spec connector Operating Temperature: -20 C to 60 C Storage Temperature: -20 C to 75 C Weight: 500 g Dimensions Page 8

RFX100-1 Third Channel Sensor The RFX100-1 has standard start-up and switch off inhibits. All inputs and outputs are reverse polarity protected and are also short circuit proof. Test Input The RFX100-1 has a test input, via which the light transmitter can be switched off. This permits checking of the complete optical system including the electronics and supply. This test can only be carried out in background suppression mode if there is an object in the sensors scanning field. Programming Functions Adjustment of the 4 programming functions is by means of a DIP switch which is on the reverse side of the printed circuit board. Just the housing cap must be removed to gain access. The functions described are programmed as follows: Switch 1 - Operating Mode HAW - background evaluation HAB - background suppression OFF Switch 2 - Switching Mode H-light switching D-dark switching OFF Switch 3- Timing Function GAN - pull in time delay OFF Switch 4 - Timing Function GAB - drop out time delay OFF The potentiometer to the left of the switches adjusts times for GAN or GAB but is not normally used. The RFX100-1 is supplied in the background suppression operating mode and should not be changed. Page 9

RFX 100-1 Single Channel Sensor Technical Data: Scanning Range: 0.2-6 meter on material with a reflection value >6% Light Beam: Modulated infrared Transmitter: IRED Receiver: Photo-diode Response/drop out time: 100ms t AN with light to dark ratio of 1:1 Supply voltage: 12-24VAC/11-48VDC Power consumption: <100mA Switching output: Voltage free relay contacts Switching voltage: Maximum 240 V AC/DC Switching current: Maximum 2 A Test input: transmitter off when connecting 15-35 VDC Switching mode: light or dark Operating mode: Background suppression Timing functions: pull in or drop out time delay Type connection: 5 meter cable with 6 pin Amphenol Mil spec connector Housing material: Macrolon, fiberglass reinforced plastic Protection category: IP 65 RFX 100-1 Sensor Operating temperature: -20 C to 60 C Function indicators: green and yellow LEDs Mounting Dimensions Page 10

ST100-3 Controller The ST100-3 controller consists of a power supply for the sensors and features one 10 Amp SPDT relay each, for channels No. 1 & 2 for output to the crane motion controls, all mounted in a NEMA 12 enclosure. The switching contacts for channel 3 are made within the RFX100-1 sensor and wired to the terminal strip in the controller. The power supply is normally 120/1/60. The system can be specified in voltages of 220 VAC, 250 VDC, or 350 VDC on special order. Dimensions Page 11